KEPCO FAW-RTW 150V User Manual

INSTRUCTION SHEET
KEPCO
An ISO 9001 Company.
MA
FAW/RTW
150V
MOUNTING ADAPTER FAW/RTW 150V
DESCRIPTION. The RoHS-compliant Model MA FAW/RTW 150V Mounting Adapter includes an adapter plate and
mounting screws that allow a 150W RTW power supply to be easily substituted for a vertically-mounted 150W FAW power supply. Mount the adapter plate to the RTW power supply using the screws provided (see Figure 1), then install the adapter plate in place of the FAW power supply using the screws that previously secured the FAW power supply.
RTW 150W
A
SEE NOTE 3.
SPACER (3)
P/N 104-0312
(FOR M4 SCREW)
SCREW (3)
P/N 101-0487
(M4 X 10MM ST. FLPO)
3043306
ADAPTER PLATE
P/N 128-2323
3.883
[97.36]
7.677 [195.0]
A
SEE NOTE 3.
NOTES:
1. MOUNT ADAPTER PLATE TO RTW USING THREE SCREWS AND THREE SPACERS AS SHOWN.
2. INSTALL ADAPTER PLATE WITH RTW ATTACHED USING "A" HOLES AND FOUR SCREWS PREVIOUSLY USED TO MOUNT FAW POWER SUPPLY (NOT SUPPLIED).
3. MAX. PENETRATION AT "A" (SCREW 4-40) MUST NOT EXCEED 5MM.
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
©2008, KEPCO, INC Data subject to change without notice
FIGURE 1. ADAPTER PLATE INSTALLATION
http://www.kepcopower.com " email: hq@kepcopower.com
228-1651 REV 1 060508
Loading...