INSTRUCTION MANUAL
KEPCO
An ISO 9001 Company.
KIT
DIN FAW
-15L, -15S, -25L,
-25S, -50L
DIN-RAIL MOUNTING KIT
FOR SERIES FAW 15W, 25W, 50W
DESCRIPTION. Kepco KITs, Models DIN FAW-15L, -15S, 25L, -25S, -25L, and -50L each contain a cover, a mounting
plate with two clips and associated hardware used to install FAW Series power supplies on a DIN rail. The -15 suffix is
for the 15 Watt Series, -25 for the 25 Watt Series and -50 for the 50 Watt Series. The “S” suffix is for mounting the
power supply along the short dimension (width) as shown in Figure 1, the “L” suffix is for mounting along the long
dimension (length) as shown in Figure 2.
FIGURE 1. S SUFFIX ORIENTATION FIGURE 2. L SUFFIX ORIENTATION
TABLE 1. COMPONENTS SUPPLIED
KIT
MODEL NO.
DIN FAW-15L CA 24 189-0700 108-0365
DIN FAW-25L CA 25 189-0690 108-0365
DIN FAW-50L CA 26 189-0695 108-0365
DIN FAW-15S CA 24 189-0701 108-0365
DIN FAW-25S CA 25 189-0702 108-0365
COVER
PAR T N O .
MOUNTING PLATE
PART NO.
CLIP (QTY 2)
PART NO.
SCREW (QTY 2)
PAR T N O .
101-0092
(4-40 X 0.312 BHPH)
101-0092
(4-40 X 0.312 BHPH)
101-0092
(4-40 X 0.312 BHPH)
101-0092
(4-40 X 0.312 BHPH)
101-0092
(4-40 X 0.312 BHPH)
WASHER (QTY 2)
PART NO.
103-0014
(NO. 4, INT. TOOTH)
103-0014
(NO. 4, INT. TOOTH)
103-0014
(NO. 4, INT. TOOTH)
103-0014
(NO. 4, INT. TOOTH)
103-0014
(NO. 4, INT. TOOTH)
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
©1998, KEPCO, INC
Data subject to change without notice 228-1297
http://www.kepcopower.com " email: hq@kepcopower.com
FAX (718) 767-1102
1

INSTALLATION
1. INSTALL COVER. Attach the cover to the power supply per instruction manual supplied with the cover.
2. INSTALL MOUNTING PLATE. Attach the mounting plate to the power supply using the hardware sup-
plied (see Figure 3).
L SUFFIX S SUFFIX
FIGURE 3. INSTALLING MOUNTING PLATE ON POWER SUPPLY
3. INSTALL CLIPS. Snap the two clips into the mounting plate holes (see Figure 4).
S SUFFIX L SUFFIX
FIGURE 4. INSTALLING CLIPS ON MOUNTING PLATE
4. INSTALL POWER SUPPLY ON DIN RAIL. To mount the power supply on the rail insert one end of both
clips under one edge of the rail, then snap the other end of the two clips into place (see Figure 5A).
REMOVING POWER SUPPLY FROM DIN RAIL. While grasping the power supply with one hand, Insert a screwdriver into the access holes provided and apply leverage towards the left as shown in Figure 5B to disengage
each clip from the rail. Where mounting clips are close together, it may be necessary to apply leverage with two
screwdrivers simultaneously.
INSTALLATION
A
B
REMOVAL
FIGURE 5. INSTALLATION AND REMOVAL OF POWER SUPPLY FROM DIN RAIL
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
2
http://www.kepcopower.com " email: hq@kepcopower.com
228-1297 061901
FAX (718) 767-1102