DESCRIPTION. Kepco KITs, Models DIN FAK-15S,
-25S, and -50S each contain a cover, mounting plate,
two clips, and associated hardware (see Table 1) used
to install FAK Series power supplies on a DIN rail. The 15 suffix is for the 15 Watt Series, the -25 for the 25 Watt
Series and -50 for the 50 Watt Series. The “S” suffix is
for mounting along the short dimension (length) as
shown in Figure 1. Outline dimensions are shown in Figure 5.
KIT
DIN FAK
-15S, -25S, -50S
FIGURE 1. S SUFFIX ORIENTATION
TABLE 1. COMPONENTS SUPPLIED
KIT
MODEL NO.
DIN FAK-15S CA 21 189-0705 108-0365
DIN FAK-25S CA 22 189-0693 108-0365
DIN FAK-50S CA 23 189-0706 108-0365
COVER
PAR T N O .
MOUNTING PLATE
PART NO.
CLIP (QTY 2)
PART NO.
SCREW (QTY 2)
PAR T N O .
101-0092
(4-40 X 0.312 BHPH)
101-0092
(4-40 X 0.312 BHPH)
101-0092
(4-40 X 0.312 BHPH)
WASHER (QTY 2)
PART NO.
103-0014
(NO. 4, INT. TOOTH)
103-0014
(NO. 4, INT. TOOTH)
103-0014
(NO. 4, INT. TOOTH)
INSTALLATION
1. INSTALL COVER. Attach the cover to the power supply per instruction manual supplied with the cover.
2. INSTALL MOUNTING PLATE. Attach the mounting plate to the power supply using the hardware supplied
(see Figure 2). Install plate so that hole closest to edge is closest to power supply terminals; and access holes
are not obstructed by power supply.
FIGURE 2. INSTALLING MOUNTING PLATE ON POWER SUPPLY
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
©1998, KEPCO, INC
Data subject to change without notice 228-1338
http://www.kepcopower.com " email: hq@kepcopower.com
FAX (718) 767-1102
1
![](/html/33/33b5/33b589ef09cabcb93bd96b355734fe0fdfb49aad770d260b2020349037e2ea20/bg2.png)
3. INSTALL CLIPS. Snap the two clips into the mounting plate holes (see Figure 3).
FIGURE 3. INSTALLING CLIPS ON MOUNTING PLATE
4. INSTALL POWER SUPPLY ON DIN RAIL. To mount the power supply on the rail insert one end of both
clips under one edge of the rail, then snap the other end of the two clips into place (see Figure 4A).
REMOVING POWER SUPPLY FROM DIN RAIL. While grasping the power supply with one hand, Insert a screwdriver into the access holes provided and apply leverage towards the left as shown in Figure 4B to disengage
each clip from the rail. Where mounting clips are close together, it may be necessary to apply leverage with two
screwdrivers simultaneously.
INSTALLATION
A
FIGURE 4. INSTALLATION AND REMOVAL OF POWER SUPPLY FROM DIN RAIL
B
REMOVAL
FIGURE 5. POWER SUPPLY WITH KIT INSTALLED, OUTLINE DIMENSIONS
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "