KEPCO BOP 1KW-MG Quick Reference Guide

Page 1
KEPCO®
THE POWER SUPPLIER™

BOP 1000W QUICK REFERENCE GUIDE

UTILITY

How do I access a password-protected menu? Enter first character of password using ADJUST control or keypad (use multiple
presses of the keys for letters or symbols: 0 (space), 1 (+, –, /), 2 (ABC), 3 (DEF), 4 (GHI), 5 (JKL), 6 (MNO). 7 (PQRS), 8 (TUV), 9 (WXYZ). T to enter next character, ! to verify. If incorrect, press CLEAR and repeat (see PAR. 3.2.4.4).
How do I use the keypad? STANDBY sets output on/off (STANDBY indicator lit when output off), MODE selects voltage mode or cur-
rent mode, arrow keys highlight selections, numbers enter values and multiple presses can enter alphanumeric characters, +/– sets sign, CLEAR sets numeric values to zero, clears alphanumerics, RESET is equivalent to power-up cycle, ENTER applies settings to output and
saves changes, HELP is context sensitive, keep pressing for more, PAR. 3.2.1).
How do I use the ADJUST control? Adjusts value of highlighted digit, fine adjustment (least significant digit) if held in while adjusting.
If output is on, directly controls output (pressing ENTER not required). Scrolls through all alphanumeric characters for password.
How do I turn the beep on or off? # , highlight Key Press Beep, !, highlight On, Error only or Off, then $. % to exit or $ to
save for power-up (see PAR. 3.2.5.2).
How do I set the display background to black or white? #, higlight Background, !, highlight Black or White, then $. % to
exit or $ to save for power-up (see PAR. 3.2.5.1). If $ not available, see NOTE to PAR. 3.2.5).
How do I adjust the Display contrast? #, #, then # when contrast is OK. R or T for fine adjustment. % to exit or $ to
save for power-up (see PAR. 3.2.5.1). If $ not available, see NOTE to PAR. 3.2.5).
How do I choose between graphical meters or time line graphs?: #, Higlight Graphic Display, !, highlight Meters or the
appropriate Graph time, then $. % to exit or $ to save for power-up (see PAR. 3.2.5.3).
! through % functions are defined by graphic box to the left (see

CONTROLLING THE OUTPUT USING THE FRONT PANEL (LOCAL)

How do I apply a voltage or current to the load? If output is on (STANDBY indicator not lit) press STANDBY to turn output off
(STANDBY indicator lit). Use MODE to select Voltage or Current mode, use Y or U to highlight main channel, use keypad to set value, then press ENTER. Highlight protect channel(s) and use keypad to set value. then press ENTER. Press STANDBY to turn output on and apply programmed settings to load (see PAR. 3.3.3).
How do I change between a single value or two different values for positive and negative protection limit? %, high-
light Max/Min Settings, !, Higlight Protect Entry, !, highlight Bipolar or Independent, then $. % to exit or $ to save for power-up (see PAR. 3.3.3.1).
How can I prevent voltage (in voltage mode) or current (in current mode) from being set beyond a predetermined level?
%, highlight Max/Min Settings, !. Higlight +Voltage Max, -Voltage Min, +Current Max or -Current Min as desired, !, use key-
pad to change value, then
$. % to exit or $ to save for power-up (see PAR. 3.3.4).
How do I prevent protection limit from being set beyond a predetermined level? %, highlight Max/Min Settings, !,
Higlight +C Protect Max, -C Protect Min, +V Protect Max or -V Protect Min as desired, exit or $ to save for power-up (see PAR. 3.3.4.2).
!, use keypad to change value, then $. % to
What happens when the protect setting is reached? Limit channel controls power supply, display shows the message CPRO-
TECT (current protection in voltage mode) VPROTECT (voltage protection in current mode) or PROTECT (external analog protection).

POWER SUPPLY SETUP

How do I configure for resistive, active or battery type load? %, highlight Load Type, !, highlight Active, Resistive, or Bat-
tery then
$. Press % to exit or $ to save for power-up (see PAR. 3.3.6).
How do I control whether the output is on or off upon *RST? %, !, highlight *RST sets Output, !, highlight On or Off, then
$. Press % to exit or $ to save for power-up (see PAR. 3.5.3.1.3).
How do I control what condition the unit is in upon power up. %, highlight Power Up Settings, !, highlight parameter, !,
highlight desired power-up state, then
$. Repeat for all parameters, then % to exit or $ to save for power-up (see PAR. 3.3.7).
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
http://www.kepcopower.com " email: hq@kepcopower.com
©2005, KEPCO, INC 228-1530-R8A 6/6/05 Data subject to change without notice
Page 2

CONTROLLING THE OUTPUT USING EXTERNAL (ANALOG) SIGNALS (REMOTE)

How do I control the mode using an external signal? $, highlight External Mode, !, highlight Enable, $, then % to apply
changes and exit. This setting is not saved for power-up (PAR. 3.4.2). Select mode by applying either logic 1 or open circuit for voltage, or logic 0 or short circuit for current, to pin 2 referenced to pin 9 of the Analog I/O port (PAR. 3.4.2).
How do I use an analog voltage to control the output (main channel)? $, highlight Reference input, !, highlight External
$, then % to apply changes and exit . This setting is not saved for power-up. Apply ±10V signal to pin 11 referenced to pin 4 of the
then Analog I/O port to control active channel (voltage or current) (PAR. 3.4.3).
How do I use an analog voltage to control the protection channel? $, highlight Protection Limit, !, highlight External then
$, then % to apply changes and exit (not saved for power-up). Apply +1V to +10V signal to the following pins referenced to pin 12 of the
Analog I/O port to control limit channel from 10% to full scale: –Current Protect: pin 5, +Current Protect: pin 13, –Voltage Protect: pin 6, +Voltage Protect: pin 14 (PAR. 3.4.4).
How do I choose between local, digital and analog control of the output? The unit normally powers up in Local mode. Sending
a command via RS 232 or GPIB interfaces automatically puts the unit into Remote mode. Press voltage is controlling the output (see above), local control of the main channel is disabled and digital commands are not accepted.
How do I use the BOP as an amplifier? See above to control the main channel and/or protection channel using analog signals. The
nominal (inherent) voltage gain of each model is calculated by (G I
/ E
Onom
How do I control the gain of the BOP when used as an amplifier? $, highlight Reference input, !, highlight ExtlRefLevl then
REF
where E
= 10V (see PAR. 3.4.3.1).
REF
NOM-V
) = E
Onom
/ E
. and nominal (inherent) current gain is (G
REF
! to restore Local mode. If an analog
NOM-I
) =
$, then % to apply changes and exit (not saved for power-up). Apply ±10V signal to pin 11 referenced to pin 4 of the Analog I/O port.
Main channel setting (SET) determines gain (G) by G = SET/10 (PAR. 3.4.3.2).

CONTROLLING THE OUTPUT USING DIGITAL INTERFACE (REMOTE)

How do I use the GPIB interface to control the power supply? %, ! to view current GPBI address. To change GPIB address,
highlight GPIB address,
How do I use the RS 232 interface to control the power supply? %, ! to view. To change Baud Rate, XON/XOFF or Prompt
if needed: highlight Baud Rate, XON/XOFF or Prompt setting, to save for power-up (see PAR. 3.5.3.2).
How do I change between SCPI and CIIL Data Format? %, !, to view. To change, highlight Data Format setting, !, highlight
SCPI or CIIL then $. % to exit or $ to save for power-up. (PAR. 3.5.3.1.2)
How do I change the Device Clear from SCPI to MATE compliant? %, !, to view. To change, highlight Device Clear setting,
!, use keypad to enter new address then $. Press % to exit or $ to save for power-up (see PAR. 3.5.3.1).
!, highlight desired selection, then $. When complete, % to exit or $
!, highlight SCPI or MATE then $. % to exit or $ to save for power-up. (PAR. 3.5.3.1.2)

FEATURES

How do I save the power supply settings for future use? !, highlight Empty location, !. The power supply settings (Mode,
type and values for Main Channel Reference and Protection, and output on/off) are displayed. To save a different setting than that dis­played, highlight the parameter, (PAR. 3.3.8)
How do I modify saved power supply settings for future use? !, highlight desired location, !. The power supply settings
(Mode, Main Channel Reference and value, Protection type and values and output on/off) are displayed. To change a setting, highlight the parameter, ! highlight the selection or enter value using keypad, then $. % to exit or $ to save for power-up. (PAR. 3.3.8)
How do I recall previously saved power supply settings? !, highlight desired location. @.to execute stored settings or ! to
see details, then
How do I view or execute a waveform? @ highlight Waveform name, ! to view, press STANDBY to turn output on, $ to exe-
cute.
% to stop waveform execution. (PAR. 3.3.9)
How do I create a waveform? Use arrow keys to highlight Empty, @, !. Enter name using ADJUST or keypad (multiple presses for
letters) and tion, highlight setting, !, enter new setting using keypad, $. To change count, highlight setting, !, enter new setting using keypad,
@ to program settings. (PAR. 3.3.8)
T, then $. To change Mode highlight selection, !.highlight Voltage or Current, $ to save for power-up. To change protec-
! highlight the selection or enter value using keypad, then $. % to exit or $ to save for power-up.
$. Define first segment (Type, Frequency, Amplitude (p-p) and Offset) by highlighting parameter, !, highlight desired setting or use key-
pad to enter value, then Define new segment or re-edit existing segment in the same way (including start/stop angle for sine or triangle), then See above to execute waveform.
How do I calibrate the unit? %, highlight Calibration, !, then proceed per screen prompts. How do I configure unipolar operation? Set either + or – Maximum to zero as follows: %, highlight Max/Min Settings, !. Higlight
+Voltage Max, -Voltage Min, +Current Max or -Current Min as desired, for power-up (see PAR. 3.3.4).
Can I further customize the configuration? Yes, contact Kepco for further information.
$. Highlight segment or End of Segments, @ to insert next segment prior to highlight or # to erase segment.
$. (PAR. 3.3.9.8)
!, press CLEAR to set to zero, then $. % to exit or $ to save