KEPCO 3.3-70K, 5-60K, 12-27K, 15-22K, 28-12K Quick Start Manual

...
Page 1
QUICK START GUIDE
An ISO 9001 Company.
SINGLE OUTPUT
PROGAMMABLE POWER SUPPLIES
I — INTRODUCTION
SCOPE OF MANUAL. This Quick Start Guide covers
the installation and operation of the Kepco RKW Series of PFC (Power Factor Corrected), RoHS (Reduction of Haz­ardous Substances) compliant, programmable switching power supplies. Full specifications are listed in the applica­ble Operator’s Manual that can be downloaded from the Kepco web site:
• 300W: www.kepcopower.com/support/ opmanls.htm#rkw300
• 600W: www.kepcopower.com/support/ opmanls.htm#rkw600
• 1500W: www.kepcopower.com/support/ opmanls.htm#rkw1500
DESCRIPTION. The Kepco RKW Programmable Series switching power supplies come in 300W, 600W and 1500W sizes (see Table 1). Each size has 3.3V, 5V, 12V, 15V, 24V, 28V and 48V models.
Units may be operated with a nominal 100V a-c to 240V a­c (input voltage range 85 to 265 Va-c), 50-60 Hz (input fre­quency range 47-66Hz). They will also operate on 110V to 370V d-c input. Overvoltage, overcurrent, overtemperature, fan failure and power failure protections and an isolated remote TTL ON-OFF control are provided for all models.
RKW
Programmable
An LED “output voltage ON” light and an output voltage adjust trimmer are provided.
II — INSTALLATION
MOUNTING THE POWER SUPPLY: Refer to Figure
1. The unit may be mounted on one mounting surface. Note the restrictions for maximum penetration of mounting screws (M4): 0.24 in (6 mm) from case. The air surrounding the power supply must not exceed the ambient values given in the graph in Figure 4.
CONNECTIONS: Figure 2 shows proper connection of one or more loads using either remote or local sensing. If
local or remote sensing is not configured, the unit will not work properly. The unit is shipped with local sense
cables in place for Local sensing. For remote sensing, remove the local sense cables and connect the +S and –S terminals to the load. Remote sensing compensation is up to 0.4V per load wire (0.15V for 3.3V models, 0.25V for 5V models). Transient recovery specs may not be met when remote sensing is used. If oscillations set off overvoltage protection, install one electrolytic capacitor (470µF min) between +S and + and one between – and –S terminals. The AC input power is applied via the terminal block. Make sure to connect the AC input Neutral, Line and Ground wires to the respective terminals of the terminal block (see Figure 3). Sensing (either Local or Remote) MUST be
used.
TABLE 1. RKW OUTPUT RATINGS
Series Rating 3.3V 5V 12V 15V 24V 28V 48V
RKW
300W
RKW
600W
RKW
1500W
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
©2010, KEPCO, INC 1 Data subject to change without notice 228-1672 REV 2
Model 3.3-70K 5-60K 12-27K 15-22K 24-14K 28-12K 48-7K
Output Current (Amperes d-c) 70A 60A 27A 22A 14A 12A 7A
Adjustment Range (Volts d-c)
Model 3.3-150K 5-120K 12-53K 15-43K 24-27K 28-23K 48-13K
Output Current (Amperes d-c) 150A 120A 53A 43A 27A 23A 13A
Adjustment Range (Volts d-c)
Model 3.3-375K 5-300K 12-125K 15-100K 24-65K 28-55K 48-32K
Output Current (Amperes d-c) 375A 300A 125A 100A 65A 55A 32A
Adjustment Range (Volts d-c)
http://www.kepcopower.com email: hq@kepcopower.com
1.8-3.6 3.5-6.0 7.2-14.4 10.5-18.0 16.8-28.8 19.6-33.6 33.6-52.8
1.8-3.6 3.5-6.0 7.2-14.4 10.5-18.0 16.8-28.8 19.6-33.6 33.6-52.8
1.8-3.6 3.5-6.0 7.2-14.4 10.5-18.0 16.8-28.8 19.6-33.6 33.6-52.8
Page 2
KEY:
AC INPUT TERMINALS:
SIGNAL TERMINALS:
DC OUTPUT TERMINALS/BUS:
NOTE: MAINTAIN A 1.25 IN. [30 MM] DISTANCE (2.0 IN. [50MM] FOR 600W) BETWEEN VENTILATION HOLES, FAN SURFACE AND SURROUNDING EQUIPMENT AND INSTALL SO AS TO PROVIDE ADEQUATE HEAT EXCHANGE TO OUTSIDE AIR.
3043386
STANDARD MOUNTING
300W
OR
600W
1500W
FIGURE 1. POWER SUPPLY MOUNTING
FIGURE 2. LOAD CONNECTIONS
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: hq@kepcopower.com
2 228-1672 REV 2 072210
Page 3
III — OPERATION
When output voltage is available, the green LED is on. The Output Voltage Adjust trimmer (see Figure 3) allows adjust­ment of the output voltage.
REMOTE ON-OFF CONTROL: When remote ON/OFF is not in use, ±RC terminals must be shorted (use shorting link supplied) for unit to operate. Remove short across ±RC and apply "high," 2.4V to 24V (or open), across ±RC to turn unit OFF (Fan Off). Apply "low," 0.0V to 0.4V (or closed) across ±RC to turn unit ON. Source current is 1.6mA maxi­mum at low level, and sink current is 1.0 mA maximum at high level. The ±RC terminals are isolated from the a-c input terminal and the DC output terminals.
REMOTE VOLTAGE PROGRAMMING: In addition to the integral trimmer, output voltage can be also be adjusted via an external variable resistance or external variable d-c voltage. Refer to the Operator’s Manuals listed on page 1 for details.
PARALLEL OR SERIES OPERATION: Power Sup­plies can be connected in parallel (with or without N+1 redundancy) for increased current or in series for increased voltage. Refer to Operator’s Manual listed on page 1 for details.
PRELIMINARY ELECTRICAL CHECK To v er if y power supply functionality, refer to Operator’s Manual listed on page 1.
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A.  TEL (718) 461-7000  FAX (718) 767-1102
http://www.kepcopower.com email: hq@kepcopower.com
072210 228-1672 REV 2 3
Units are shipped with links between ±RC, REF to RV and local sensing enabled: cables (300W and 600W) and links
KEY:
1. Frame Ground (earth)
2. AC Input: L (Line), N (Neutral)
3. DC Output (+, –)
4. ± Sense
5. REF (Output Voltage Reference)
6. RV (Remote Voltage)
7. CB (Current Balance)
8. ±PF (Power Fail)
9. ±RC (Remote ON-OFF Control)
10. Vadj (Output Voltage Trim Adjustment
11. ON (Output Voltage ON LED)
12. Local Sense Cable (connects + to +S and - to -S)
13. ±M [1500W only] Output voltage monitor terminals
FIGURE 3. COMPONENT LOCATIONS
Page 4
FIGURE 4. OUTPUT POWER VS. TEMPERATURE
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: hq@kepcopower.com
4 228-1672 REV 2 072210