2WARNING
To prevent injury or fire, take the following precautions:
• When extending the ignition, battery, or ground wires, make sure to use automotive-grade wires or other wires with a 8 mm² (AWG 8) or more to prevent wire deterioration and damage to the wire coating.
• To prevent a short circuit, never put or leave any metallic objects (such as coins or metal tools) inside the unit.
• If the unit starts to emit smoke or strange smells, turn off the power immediately and consult your Kenwood dealer.
• Do not touch the unit during use because the surface of the unit becomes hot and may cause burns if touched.
FCC WARNING
This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.
2CAUTION
To prevent damage to the machine, take the following precautions:
• Be sure the unit is connected to a 12V DC power supply with a negative ground connection.
• Do not open the top or bottom covers of the unit.
• Do not install the unit in a spot exposed to direct sunlight or excessive heat or humidity. Also avoid places with too much dust or the possibility of water splashing.
• When replacing a fuse, only use a new one with the prescribed rating. Using a fuse with the wrong rating may cause your unit to malfunction.
• To prevent a short circuit when replacing a fuse, first disconnect the wiring harness.
Available Control Units:
A Kenwood’s LX-Bus supporting Center Unit released in 2004 or later can control this unit. The operations of the (LX) AMP Control are explained in the Operation Manual of the Center Unit.
NOTE
• The LX AMP and the sensor unit cannot be connected simultaneously. You must connect any of them at a time.
NOTE
• If you experience problems during installation, consult your Kenwood dealer.
• If the unit does not seem to be working right, consult your Kenwood dealer.
Cleaning the unit
If the front panel gets dirty, turn off the power and wipe the panel with a dry silicon cloth or soft cloth.
2CAUTION
Do not wipe the panel with a hard cloth or a cloth dampened by volatile solvents such as paint thinner and alcohol. They can scratch the surface of the panel and/or cause the indicator letters to peel off.
To prevent battery rise
When the unit is used in the ACC ON position without turning the engine ON, it depletes the battery. Use it after starting the engine.
Protection function
There is a Protection function installed in the unit to protect the unit and speakers from various problems. When Protection operates, the display informs you of the condition.
Display Informations
"E-01" When the inside of the unit is overheating. "E-02"
"E-03"
"VOLT" display is blinked.
When the unit has failed and direct current voltage is generated to the speaker’s output.
NOTE
Turn the power OFF and release the protection. If the "E-02" code does not disappear, contact your Kenwood dealer.
When the speaker cord is shorted. When the speaker output is in contact with the vehicle ground.
When voltage gets out of operation range.
Wiring
• Take the battery wire for this unit directly from the battery. If it’s connected to the vehicle’s wiring harness, it can cause blown fuses etc.
• If a buzzing noise is heard from the speakers when the engine is running, connect a line noise filter (optional) to each of the battery wire.
• Do not allow the wire to directly contact the edge of the iron plate by using Grommets.
• Connect the ground wire to a metal part of the car chassis that acts as an electrical ground passing electricity to the battery‘s negative - terminal. Do not turn the power on if the ground wire is not connected.
• Be sure to install a protective fuse in the power cord near the battery. The protective fuse should be the same capacity as the unit’s fuse capacity or somewhat larger.
• For the power cord and ground, use a vehicle type (fireproof ) power wring cord with a current capacity greater than the unit’s fuse capacity. (Use a power wiring cord with a diameter of 8 mm² (AWG 8) or greater.)
• When more than one power amplifier are going to be used, use a power supply wiring wire and protective fuse of greater current-handling capacity than the total maximum current drawn by each amplifier.
NOTE
This Class B digital apparatus complies with Canadian ICES-003.
This Product is not installed by the manufacturer of a vehicle on the production line, nor by the professional importer of a vehicle into an EU Member State.

2 English

Speaker Selection
• The rated input power of the speakers that are going to be connected should be greater than the maximum output power (in Watts) of the amplifier. Use of speakers having input power ratings that are less than the output power of the amplifier will cause smoke to be emitted as well as damage.
• The impedance of the speakers that are going to be connected should be 2Ω or greater (for stereo connections), or 4Ω or greater (for bridged connections). When more than one set of speakers are going to be used, calculate the combined impedance of the speakers and then connect suitable speakers to the amplifier.
4
4
8
4 4
2
Combined impedance
Installation
Duct
Cooling fan
Cover
Installation board, etc. (thickness : 15 mm or more)
446 mm 432 mm
4/3/2channel PowerAmplifier
HPFOPERATION LPFOPERATION
0
0
-4
-4
-8
-8
-12
-12
-16
-16
-20
-20
30
50100 200400 1K(Hz) 30
50100 200400 1K(Hz)
Hexagon socket head cap screw (M4 × 8 mm)
150
100
70
50 200
LPF
FREQUENCY(Hz)
200Hz 150Hz 100Hz 70Hz 50Hz
VOLTFAN
CURRTEMP
100
100
1
2
150
70
150
70
0.5
3
0.3
4
0.2(MAX)(MIN)5
50 200
50 200
INPUT
HPF
HPF
SENSITIVITY(V)
FREQUENCY(Hz)
FREQUENCY(Hz)
Bch Ach
AMPCONT
ISF
HPF
OPERATION
FILTER
HPF
ON
ON
ON
MONO(Lch)
OFF
LPF
OFF
OFF
OFF
STEREO
Hexagon Wrench
Self-tapping screw (ø5 × 18 mm)
1
2
0.5
3
0.3
4
0.2(MAX)(MIN)5
INPUT
SENSITIVITY(V)
OPERATION
MONO(Lch)
STEREO
Cooling fan
Accessories
Self-tapping screws (ø5 × 18 mm) Hexagon socket head cap screw (M4 × 8 mm)
Cover
157 mm
252 mm
265 mm
Terminal cover (Power terminal) 1
Hexagon Wrench
Ø6
Part name External View Number of Items
4
4
1
1
Installation procedure
Since there are large variety of settings and connections possible according to applications, read the instruction manual well to select the proper setting and connection.
1. Remove the ignition key and disconnect the negative - terminal of the battery to prevent short circuits.
2. Set the unit according to the intended usage.
3. Connect the input and output wires of the units.
4. Connect the speaker wires.
5. Connect the power wire, power control wire and grounding wire following this order.
6. Install the installation fittings in the unit.
7. Attach the unit.
8. Install the terminal cover.
9. Connect the negative - terminal of the battery.
2CAUTION
• Do not install in the below locations; (Unstable location, In a location that interferes with driving, In a location that gets wet, In a dusty location, In a place that gets hot, In a place that gets direct sunlight, In a location that gets hit by hot air)
• Do not install the unit under the carpet. Otherwise heat build-up occurs and the unit may be damaged.
• Install this unit in a location which allows heat to easily dissipate. Once installed, do not place any object on top of the unit.
• The surface temperature of the amplifier will become hot during use. Install the amplifier in a place where people, resins, and other substances that are sensitive to heat will not come into contact with it.
• This unit has cooling fans to decrease the internal temperature. Do not mount the unit in a place where the cooling fan and ducts of the unit are blocked. Blocking these openings will inhibit the cooling of the internal temperature and result in malfunction.
• When making a hole under a seat, inside the trunk, or somewhere else in the vehicle, check that there is nothing hazardous on the opposite side such as a gasoline tank, brake pipe, or wiring harness, and be careful not to cause scratches or other damage.
• Do not install near the dashboard, rear tray, or air bag safety parts.
• The installation to the vehicle should securely fasten the unit to a place in which it will not obstruct driving. If the unit comes off due to a shock and hits a person or safety part, it may cause injury or an accident.
• After installing the unit, check to make sure that electrical equipment such as the brake lamps, turn signal lamps and windshield wipers operate normally.
English 3
Connection
* Commercially available parts
2WARNING
To prevent fire caused by a short in the wiring, connect a fusible link or breaker nearby the battery’s positive terminal.
2CAUTION
• If sound is not output normally, immediately turn power off and check connections.
• Be sure to turn the power off before changing the setting of any switch.
• If the fuse blows, check wires for shorts, then replace the fuse with one of the same rating.
• Check that no unconnected wires or connectors are touching the car body. Do not remove caps from unconnected wires or connectors to prevent short circuits.
• Connect the speaker wires to appropriate speaker connectors separately. Sharing the negative wire of the speaker or grounding speaker wires to the metal body of the car can cause this unit to fail.
• After installation, check that the brake lamps, winkers, and wipers work properly.
Terminal cover
Battery wire*
Protective Fuse*
CENTER UNIT (CD receiver, etc.)
Power control wire
30
30
Lead terminal*
RCA cable ground terminal
GND
5
6
4
7
3
8
2
9
1
0
Bridged Connections
RCA cable*
B channel input
A channel input
A channel Right speaker
A channel Left speaker
B channel Right speaker
B channel Left speaker
A channel Speaker (Bridged)
LX-Bus connection
CENTER UNIT
Power control wire
30
30
Master amplifier
Extension wire*
30
30
Slave amplifier 1
Battery
To Kenwood disc changer/ External optional accessory
Control cable (option)
5
4
3
2
"0"
1
ID NUMBER
S-video cable*
5
4
3
2
"1" – "7"
1
ID NUMBER
5
6
4
7
3
8
2
9
1
0
6
7
8
9
0
5
6
4
7
3
8
2
9
1
0
6
7
8
9
0
Ground wire*
B channel Speaker (Bridged)
Set the ID number of the Master amplifier to "0". You can connect up to 7 Slave amplifiers. Assign them ID numbers "1"
to "7" and do not duplicate them.
2CAUTION
• Do not connect 2 Master amplifiers to the Center Unit. If done, you cannot control all amplifiers connected to the Center Unit.
• The LX AMP and the sensor unit cannot be connected simultaneously. You must connect any of them at a time.
NOTE
• The total length of S-video cables you can connect is 14 meters (46 ft) maximum. If the cable length exceeds this limit, you cannot control amps from the Center Unit.
• If you assign the same ID number to multiple amplifiers, they malfunction when you operate any of them from the Center Unit.
• If you assign ID number "8" or "9" to a Slave amplifier, it is not recognized by the Center Unit.
RCA cable*
Slave amplifier 7
4 English
Not more than 14m (46 ft)
30
30
"1" – "7"
5
4
3
2
1
0
ID NUMBER
5
6
4
7
3
8
2
9
1
0
6
7
8
9
Controls
Bch Ach
INPUT
SENSITIVITY(V)
INPUT
SENSITIVITY(V)
HPF
FREQUENCY(Hz)
HPF
FREQUENCY(Hz)
LPF
FREQUENCY(Hz)
4
0.2(MAX)(MIN)5
3
2
1
0.5
0.3
4
0.2(MAX)(MIN)5
3
2
1
0.5
0.3
50 200
50 200
150
100
70
50 200
150
100
70
150
100
70
FILTER
HPF
LPF
OFF
AMPCONT
ON
OFF
ISF
ON
OFF
HPF
ON
OFF
OPERATION
MONO(Lch)
STEREO
OPERATION
MONO(Lch)
STEREO
HPFOPERATION LPFOPERATION
50Hz
70Hz
100Hz
150Hz
200Hz
30
-20
-16
-12
-8
-4
0
50 100 200400 1K(Hz) 30
-20
-16
-12
-8
-4
0
50 100 200400 1K(Hz)
3
30
0
5
6
4
7
3
8
2
9
1
0
1
# *()
This is a 4 channel amplifier including 2 stereo amplifiers in a body. One amplifier is referred to as amplifier A and the other is amplifier B. This unit is compatible with a large variety of systems by combining the switches and functions described in the following.
1 Fuse (30 A × 2) 2 Battery terminal 3 Ground terminal 4 Power control terminal
Controls the unit ON/OFF.
NOTE
Controls the unit power. Be sure to connect it with all the systems.
5 Speaker output terminals (A.ch/B.ch)
• Stereo Connections:
When you wish to use the unit as a stereo amplifier, stereo connections are used. The speakers to be connected should have an impedance of 2Ω or greater. When multiple speakers are to be connected, ensure that the combined impedance is 2Ω or greater for each channel.
• Bridged Connections:
When you wish to use the unit as a high-output monaural amplifier, bridged connections are used. (Make connections to the LEFT channel 9 and the RIGHT channel · SPEAKER OUTPUT terminals.) The speakers to be connected should have an impedance of 4Ω or greater. When multiple speakers are to be connected, ensure that the combined impedance is 4Ω or greater.
2CAUTION
The rated input of the speakers should be no less than the maximum output of the amplifier. Otherwise malfunction may result.
6 RCA cable ground lead terminal
When using an RCA cable with a ground lead attached, connect the ground lead to this terminal.
7 ID NUMBER switch
Sets an amp identification number (ID) to be used for amplifier control from the Center Unit. Assign ID Number "0" to an amplifier when you use it as the Master amplifier. Assign ID Numbers "1" to "7" to amplifiers when you use them as Slave amplifiers. Do not duplicate these numbers.
NOTE
After you have changed ID numbers of amplifiers, turn Off the POWER switch of the Center Unit and turn it On again.
8 TO H/U terminal
After you have set the Master amplifier, connect it to the Center Unit.
9 REMOTE terminals
Used to connect to Slave amplifiers.
0 RESET button
Resets the microprocessor of the unit.
NOTE
The values you have set with the Amplifier Control are NOT reset.
! LINE IN terminal (A.ch/B.ch) @ LINE OUT terminal
These jacks output respectively the signals input to amplifiers A and B. They always output the stereo signals regardless of the position of the OPERATION switch.
6
$
89
7
%&
^
04532 @!
@1
# Power indicator
Lights when the POWER switch is turned On. The indicator flashes several seconds when the POWER switch is turned On or when the Protection function is activated.
$ HPF FREQUENCY control (A.ch/B.ch)
A: Sets the cutoff frequency when the "HPF" switch is set to "ON". B: Sets the cutoff frequency when the "FILTER" switch is set to "HPF".
% LPF FREQUENCY control (B.ch)
Sets the cutoff frequency when the "FILTER" switch is set to "LPF".
^ FILTER switch (B.ch)
This switch allows to apply high-pass or low-pass filtering to the speaker outputs.
• HPF (High-Pass Filter) position:
The filter outputs the band of higher frequencies than the frequency set with the "HPF FREQUENCY" control.
• OFF position:
The entire bandwidth is output without filtering.
• LPF (Low-Pass Filter) position:
The filter outputs the band of lower frequencies than the frequency set with the "LPF FREQUENCY" control. The speaker output is automatically switched to monaural (L+R).
& AMP CONT (amplifier control) switch (B.ch)
Used to bypass the circuit when you do not control the sound with the Amplifier Control.
• ON position:
You can control the sound of amplifier B using the Amplifier Control.
• OFF position:
Bypasses the Amplifier Control circuit.
NOTE
Amplifier control is possible even while OFF.
* ISF (infrasonic filter) switch (B.ch)
When this switch is "ON", the frequencies which are below the audible range and therefore inaudible are cut off so that the quality of the audible frequencies can be improved.
( OPERATION switch (A.ch/B.ch)
The amplification methods of the signals input to amplifiers A and B can be selected independently according to the setting of this switch.
• STEREO position:
The amplifier can be used as a stereo amplifier.
• MONO (Lch) position:
Amplifies the signal input from the left side only. Set to this position and make bridged connections to use as a high-power monaural amplifier. (The input right signal is not output.)
) HPF (High-Pass Filter) switch (A.ch)
This switch allows to apply high-pass filtering to the speaker outputs.
• ON position:
The filter outputs the band of higher frequencies than the frequency set with the "HPF FREQUENCY" control.
• OFF position:
The entire bandwidth is output without filtering.
@1
INPUT SENSITIVITY control (A.ch/B.ch)
Set this control according to the pre-output level of the center unit connected with this unit.
NOTE
For the pre-output level, refer to the <Specifications> in the instruction manual of the center unit.
English 5
Amplifier Control System
Indicator
Display mode
You can set up the display items as follows:
1 Enter Menu mode
Press the [MENU] button.
"VOLT"/"CURR"/"TEMP"/"FAN" is displayed.
2 Select a display item
Press the [2] or [3] button.
The display items are switched in the following sequence.
Display Information
"VOLT" Indicates the source voltage (V). "CURR" Indicates the current consumption (A). "TEMP" Indicates the internal temperature (°F/°C). "FAN" Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF".
3 Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is displayed.
Separate Amp Control
The following explains how to control the sound of amplifier B using the Amplifier Control of the unit.
VOLTFAN
CURRTEMP
2
3 4
INPUT
SENSITIVITY(V)
ISF
ON
OFF
1
0.2(MAX)(MIN)5
0.5
0.3
OPERATION
100
70
50 200
HPF
FREQUENCY(Hz)
MONO(Lch)
STEREO
1
2
150
3 4
0.2(MAX)(MIN)5
INPUT
SENSITIVITY(V)
HPF
OPERATION
ON
MONO(Lch)
OFF
STEREO
HPFOPERATION LPFOPERATION
0
-4
-8
-12
-16
-20 30
50 100 200400 1K(Hz) 30
-4
-8
-12
-16
-20
0
50 100 200400 1K(Hz)
100
70
50 200
LPF
FREQUENCY(Hz)
200Hz 150Hz 100Hz
70Hz 50Hz
150
70
FREQUENCY(Hz)
FILTER
HPF
LPF
100
150
50 200
HPF
Bch Ach
AMPCONT
ON
OFF
OFF
4 Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
When you hold down the [3] button 3 or more seconds during ID number display ("AMP"), message "MEMO" is displayed and you can register the values you have set with the Amplifier Control. To call the Amplifier Control’s values, hold down the [2] button 3 or more seconds during ID number display ("AMP"). Then, you can recall the value when message "LOAD" is displayed.
Default
Resets all values you have set to the initial (default) values.
1 Enter Menu mode
Press the [MENU] button.
2 Select Default mode
Press the [MENU] button.
Select the "DEFA" display.
3 Resets the value to its default
Press the [3] button for at least 2 seconds.
Message "----" is displayed, and the value is initialized.
4 Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
Volume offset value can not be initialized.
MENU
2 / 3
0.5
0.3
1 Enter Menu mode
Press the [MENU] button.
2 Select the Menu item
Press the [MENU] button.
The setup items are displayed approximately 1 second first, then the set values are displayed.
3 Adjust the Menu item
Press the [2] or [3] button.
The setup items and set values are switched as follows.
Display
Range Adjustment Item
"VOLT"/"CURR"/"TEMP"/"FAN" "BASS"
60/80/100/200 (Hz) Bass Center Frequency
"BA G"
B–15 — B+15 (dB) Bass level Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor
"BA Q" "EXT"
ON/OFF When the bass extend is set to ON, low frequency response is
"TREB"
10/12/15/17 (kHz) Treble Center Frequency
"TR G"
T–15 — T+15 (dB) Treble level
"VOL"
–20 — 0 (dB) Volume offset
"TEMP"
FAHR (Fahrenheit) or
CELS (Centigrade) "DEFA" "AMP"
0 — 7 The ID Number you have assigned is displayed.
For the operation method refer to <Display mode>
extended by 20%.
The Fahrenheit or Centigrade temperature unit can be selected for the Display mode.
For the operation method refer to <Default>
Display Demonstration
The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly.
Press the [MENU] button for at least 2 seconds.
The indicator flashes in the Demonstration mode.
Canceling the Demonstration mode
Press any button to cancel the Demonstration mode.
6 English
Control an Amp from Center Unit
The following explains how to control the sound of Amplifier B by operating the Amplifier Control of the unit from the Center Unit.
Messages that may be displayed on the Center Unit
When you are selecting an item with the Amp Control, an error status of the amplifier is displayed on the Center Unit.
1 Enter AMP Control mode
Select the AMP Control mode by following the <AMP Control> procedure given on the Operation Manual of the Center Unit.
NOTE
Use the set item and value operation buttons by following the instructions given on the Operation Manual of the Center Unit.
2 Select an amp number to operate
Operate the desired set item with the Center Unit.
Select the "AMP NO"/"AMP CONTROL NO" display.
NOTE
When the Center Unit is in the STANDBY mode, message "AMP OFF" is displayed and you cannot operate the set items.
3 Set an ID number of Amp to operate
Set an amp’s ID number on the Center Unit.
You can select an ID number of "0" to "7" of connected amps.
4 Select the AMP Control item for adjustment
Select the desired set item on the Center Unit.
5 Adjust the AMP Control item
You can set a value of each item on the Center Unit.
The set items and their values are switched and displayed as follows.
Display Range Adjustment Item
"VOLT"/"CURR"/"TEMP"/"FAN" The amp state is displayed.
"BAS F"/"BASS FREQ" 60/80/100/200 (Hz) Bass Center Frequency "BAS G"/"BASS GAIN" –15 — +15 (dB) Bass level "Q FA"/"Q FACTOR" Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor "EXT"/"BASS EXT" ON/OFF When the bass extend is set to ON, low
"TRE F"/"TREB FREQ" 10/12/15/17 (kHz) Treble Center Frequency "TRE G"/"TREB GAIN" –15 — +15 (dB) Treble level "VOL"/"VOL OFFSET" –20 — 0 (dB) Volume offset "AMP NO"/
"AMP CONTROL NO"
"VOLT" "CURR" "TEMP" "FAN"
0 — 7 Select an ID number of the amp you use.
Indicates the source voltage (V). Indicates the current consumption (A). Indicates the internal temperature (°F/°C). Indicates the rotation speed of the cooling fan
in 3 steps: "FAST", "SLOW" or "OFF".
frequency response is extended by 20%.
Display Informations
"AMP × E-01"/"AMP × COND E-01" When the inside of the unit is overheating.
"AMP × E-02"/"AMP × COND E-02"
"AMP × E-03"/"AMP × COND E-03"
"AMP OFF" When you use the Amp Control in the Standby mode.
NOTE
Number "×" on the display indicates the amp’s ID number.
When the unit has failed and direct current voltage is generated to the speaker’s output.
NOTE
Turn the POWER switch Off and release the protection. If the error message continues, consult to the Kenwood’s dealership.
When the speaker cord is shorted. When the speaker output is in contact with the vehicle ground.
6 Exit AMP Control mode
Releases the Amp Control mode by the Center Unit.
NOTE
When you have controlled the bass or treble of the sound using the Equalizer or DSP function of the Center Unit, and when you amplify the same frequency as that controlled by the Amplifier Control, the sound may be distorted due to an input overflow.
English 7
System examples
4-channel system ■ High-power 2-channel system
L
L
2
3
4
INPUT
SENSITIVITY(V)
ISF
ON
OFF
1
0.2(MAX)(MIN)5
R
L
R
0.5
0.3
OPERATION
A
R
L
B
R
100
70
50 200
HPF
FREQUENCY(Hz)
MONO(Lch)
STEREO
150
HPF
ON
OFF
CENTER UNIT
150
100
70
70
FREQUENCY(Hz)
50 200
LPF
50 200
FREQUENCY(Hz)
FILTER
HPF
LPF
100
150
HPF
Bch Ach
AMP CONT
ON
OFF
OFF
2-channel + Subwoofer system
L
L
CENTER UNIT
150
100
70
70
FREQUENCY(Hz)
50 200
LPF
50 200
FREQUENCY(Hz)
FILTER
HPF
LPF
100
150
3
HPF
SENSITIVITY(V)
Bch Ach
AMP CONT
ON
OFF
OFF
A
R
R
L
L
B
R
R
100
1
2
4
0.2(MAX)(MIN)5
INPUT
ISF
ON
OFF
0.5
0.3
OPERATION
70
50 200
HPF
FREQUENCY(Hz)
MONO(Lch)
STEREO
150
HPF
ON
OFF
2
3
4
INPUT
SENSITIVITY(V)
OPERATION
MONO(Lch)
STEREO
2
3
4
INPUT
SENSITIVITY(V)
OPERATION
MONO(Lch)
STEREO
Front Left speaker Front Right speaker
Rear Left speaker Rear Right speaker
1
0.5
0.3
0.2(MAX)(MIN)5
Left speaker (High pass) Right speaker (High pass)
Subwoofer (Bridged)
1
0.5
0.3
0.2(MAX)(MIN)5
CENTER UNIT
150
100
70
70
50 200
LPF
FREQUENCY(Hz)
FREQUENCY(Hz)
FILTER
HPF
LPF
L
R
100
2
150
3
4
50 200
INPUT
HPF
SENSITIVITY(V)
Bch Ach
AMP CONT
ISF
ON
ON
OFF
OFF
OFF
1
L
R
L
R
0.5
0.3
0.2(MAX)(MIN)5
A
B
70
FREQUENCY(Hz)
OPERATION
MONO(Lch)
STEREO
L
R
L
R
100
50 200
HPF
150
HPF
ON
OFF
2
3
4
INPUT
SENSITIVITY(V)
OPERATION
MONO(Lch)
STEREO
Left speaker (Bridged)
Right speaker (Bridged)
1
0.5
0.3
0.2(MAX)(MIN)5
Tri-mode
CENTER UNIT
100
70
50 200
LPF
FREQUENCY(Hz)
100
150
70
FREQUENCY(Hz)
FILTER
HPF
LPF
2
150
3
4
50 200
INPUT
HPF
SENSITIVITY(V)
Bch Ach
AMP CONT
ON
OFF
OFF
(High pass)
LRL
A
LRL
B
1
70
0.5
0.3
0.2(MAX)(MIN)5
FREQUENCY(Hz)
ISF
OPERATION
ON
MONO(Lch)
OFF
STEREO
R
R
100
50 200
HPF
HPF
ON
OFF
150
C
C
C
C
2
3
4
INPUT
SENSITIVITY(V)
OPERATION
MONO(Lch)
STEREO
Subwoofer (L + R) (Bridged)
L
L
1
0.5
0.3
0.2(MAX)(MIN)5
Principle of Tri-mode
Method of frequency band division using a coil and capacitor…in case of 6dB/oct. slope.
Coil (L):
Passes low frequencies and blocks high frequencies. (Low pass)
Capacitor (C):
Passes high frequencies and blocks low
0 dB
-3 dB
Crossover Frequency
L
C
frequencies. (High pass)
Frequency
159 x R L= (mH) fc
159000 C= (µF) fc × R
fc=Cut of Frequency (Hz) R=Speaker Impedance (Ω)
Example:
When it is required to set a crossover frequency of 120 Hz using speakers with an impedance of 4 ohms.
Prepare commercially-available coil and capacitor with the closest ratings to the results calculated from the formula above. The capacitor rating should be as close as possible to 331.25 (µF) and the coil rating should be as close as possible to 5.3 (mH).
2CAUTION
• If you wish to bridge-connect a speaker, the speaker impedance must be no less than 4 ohms. Connecting a speaker with an impedance lower than 4 ohms may damage the unit.
• Be sure to connect capacitors to speakers to which high frequencies will be passed. Failure to do so will result in a drop of the combined impedance with the subwoofer.
• Ensure that the withstand voltage and current ratings of the capacitors (C) and coils (L) are sufficient.
8 English
Troubleshooting Guide
What might appear to be a malfunction in your unit may just be the result of slight misoperation or miswiring. Before calling service, first check the following table for possible problems.
PROBLEM POSSIBLE CAUSE SOLUTION
No sound. (No sound from one side.) (Blown fuse.)
The output level is too small (or too large). The sound quality is bad. (The sound is distorted.)
The sound does not change even when you have changed it with the Amplifier Control. The set value cannot be changed by the Amplifier Control of the unit. The Amplifier Control cannot be operated from the Center Unit.
• Input (or output) cables are disconnected.
• Protection circuit may be activated.
• Volume is too high.
• The speaker cord is shorted.
• The input sensitivity adjusting control is not set to the correct position.
• The speakers wire are connected with wrong + /-polarity.
• A speaker wire is pinched by a screw in the car body.
• The switches may be set improperly.
• The AMP CONT has been turned "OFF".
• The filtered band has been controlled by the Amplifier Control.
• The AMP Control of the Center Unit is being used. • Release the AMP Control mode of the Center Unit.
• An incorrect ID number is used for the Master amplifier.
• The ID number of the amplifier has been changed.
• Connect the input (or output) cables.
• Check connections by referring to <Protection function>.
• Replace the fuse and use lower volume.
• After check the speaker cord and fixing the cause of the short, replace the fuse.
• Adjust the control correctly referring to <Controls>.
• Connect them properly checking the + / - of the terminals and wires well.
• Connect the speaker wire again so that it is not pinched by anything.
• Set switches properly by referring to <System examples>.
• Turn the AMP CONT "ON".
• Turn the filter Off.
• Always set the ID number of the Master amplifier to "0".
• After you have changed the ID number of an amplifier, turn Off the POWER switch of the Center Unit first, then turn it On again.
Specifications
Specifications subject to change without notice.
Audio Section
Max Power Output .......................................................................................................................................................................................................................960 W
Rated Power Output (+B = 12.0 V)
Normal (4 Ω) (20 Hz – 20 kHz, 0.05 % THD) ................................................................................................................................................45 W × 4
Normal (2 Ω) (1 kHz, 0.5 % THD) ....................................................................................................................................................................... 90 W × 4
Bridged (4 Ω) (1 kHz, 0.5 % THD) ....................................................................................................................................................................180 W × 2
Rated Power Output (+B = 14.4 V)
Normal (4 Ω) (20 Hz – 20 kHz, 0.05 % THD) ................................................................................................................................................60 W × 4
Normal (4 Ω) (DIN : 45324 , +B = 14.4V) .......................................................................................................................................................60 W × 4
Normal (2 Ω) (1 kHz, 0.5 % THD) .....................................................................................................................................................................120 W × 4
Bridged (4 Ω) (1 kHz, 0.5 % THD) ....................................................................................................................................................................240 W × 2
Low Pass Filter Frequency (24 dB/oct.) (B channel) ...................................................................................................................50 – 200 Hz (variable)
High Pass Filter Frequency (12 dB/oct.) ............................................................................................................................................50 – 200 Hz (variable)
Infrasonic Filter Frequency (24 dB/oct.) (B channel) .................................................................................................................................................... 15 Hz
Frequency Response (+0, –3 dB) ...........................................................................................................................................................................5 Hz – 50 kHz
Signal to Noise Ratio ...................................................................................................................................................................................................................105 dB
Sensitivity (rated output) (MAX.) ..............................................................................................................................................................................................0.2 V
Sensitivity (rated output) (MIN.) ...............................................................................................................................................................................................5.0 V
Input Impedance ............................................................................................................................................................................................................................ 10 kΩ
Amplifier Control Section (EQ) (B channel)
Bass frequency ..............................................................................................................................................................................................60 / 80 / 100 / 200 Hz
Bass level ........................................................................................................................................................................................................................... -15 — +15 dB
Bass Q factor .................................................................................................................................................................................................1.00 / 1.25 / 1.50 / 2.00
Treble frequency .............................................................................................................................................................................................10 / 12 / 15 / 17 kHz
Treble level ....................................................................................................................................................................................................................... -15 — +15 dB
General
Operating Voltage ........................................................................................................................................................................... 14.4 V (11 – 16 V allowable)
Current Consumption ....................................................................................................................................................................................................................42 A
Dimensions (W × H × D) ..........................................................................................................................................................................446 × 61 × 259.5 mm
..............................................................................................................................................................................................17-5/8 × 2-3/8 × 10-3/16 inch
Installation Size (W × H × D) ..................................................................................................................................................................... 446 × 61 × 265 mm
.................................................................................................................................................................................................17-5/8 × 2-3/8 × 10-3/8 inch
Weight ..........................................................................................................................................................................................................................4.47 kg (9.85 lbs)
CEA-2006
RMS Watts per channel @ 4 ohms < 1 % THD+N ................................................................................................................................................... 88 W × 4
RMS Watts per channel @ 2 ohms < 1 % THD+N .................................................................................................................................................124 W × 4
English 9
Loading...
+ 19 hidden pages