The system is initialized when the power is turned on while
pressing the POWER key.
(1) Contents of operation
• All the functions are initialized.
2-2. AMP test mode using main unit's keys
2-2-1. Entering the AMP test mode
• Turn on the power while pressing the BAND key.
2-2-2. Canceling the AMP test mode
• By turning off the power, the system is initialized and the
test mode is canceled.
2-2-3. Contents of AMP test mode
(1) Automatic POWER ON
• The POWER ON state is entered whenever the power is
turned on while pressing the BAND key. All functions are
then initialized and activated in the all-lighting mode.
• Sub-clock oscillation diagnosis function
The oscillation diagnosis (existence of oscillation and
measurement of period) of a sub-clock is performed
before the test mode is entered. If the diagnosis result is
OK, the system enters the test mode.
If the diagnosis result is NG, the oscillation of the subclock is diagnosed again. If the result is OK, the system
enters the test mode. If the diagnosis result is continuously NG five times, the system stops with ERR 1 and
ERR 2 displayed.
(2) All-lighting mode
• All the fluorescent display indicators and LED lamps light
when the power is turned on while pressing the BAND
key.
• After that, the all-lighting mode is canceled when any
main unit's key is pressed. The normal display obtained
when the selector is set to TUNER then appears.
(3) Others
• The AMP test mode is not terminated even if the selector
is set to positions other than TUNER.
• In the AMP test mode, the muting during mode selection
is not controlled. However, the operation during the
power-on sequence is the same as the normal operation.
• The SP protection operation is also the same as the normal operation.
• In the AMP test mode using main unit's keys, the keys
below provide a special operation according to the position where the selector is set. The main unit's keys
except described below and the rotary encoder provide
the normal operation.
(4) When selector is set to TUNER
KeyOperation
EX. BASS keyIncrements the P.CALL every time this
key is pressed.
N.B. key Decrement the P.CALL every time this
key is pressed.
ENTER keySelects the display cyclically in the order
below every time this key is pressed.
1 Write data in the unused area of E2PROM, then read the
written data. If the read data is the same as the written
data, "RAM OK" is displayed in the fluorescent display
indicator. If the former is different from the latter, "RAM
NG" is displayed.
2 Set the TUNER ATT to OFF and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT
OFF **" is displayed in the fluorescent display indicator.)
3 Set the TUNER ATT to ON and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT ON
**" is displayed in the fluorescent display indicator.)
* The special display using the ENTER key is continued until
the next operation is carried out. (**: S LEVEL)
When keys other than ENTER are pressed in items 1 to 3
above, the TUNER ATT is set to OFF and the normal display
appears. The operation corresponding to the key that has
been pressed is performed in this case.
(5) When selector is set to positions other than TUNER
[ENTER key] Every time this key is pressed, master VOL-
UME level is selected cyclically.
INITIALIZE level
Value of Master VOLUMEPress the ENTER key.
MAX86
MID40
MIN1
INITIALIZE7
ìî MAX î MID î MIN ì
3
R-SE9/SE9T
CIRCUIT DESCRIPTION
[ AUTO key ] Selects the MUTE operation and equalizer
cyclically in the order below for operation display every time
this key is pressed.
-- -> MUTE operation -> Minimum -> Maximum ->
✣ In the operation for except the AUTO key, become pre-
condition equlizer .
✣ Pre condition : The equlizer becomes the condition to be
pushed the AUTO key before
(include N.B. circuit).
(6) SERIAL TEST CODE LIST
Refer to Service manual (B51-5210-00) of R-SA7 on
page 7.
[ BAND key ] Every time this key is pressed, all the displays
go off and the normal display is selected cyclically.
✣ Pre-condition
--
2-3. RDS test mode using main unit's keys
2-3-1. Entering the RDS test mode
• Turn on the power while pressing the N.B. key.
2-3-2. Canceling the RDS test mode
• By turning off the power, the system is initialized and the
test mode is canceled.
2-3-3. Contents of RDS test mode
• The POWER ON state is entered whenever the power is
turned on while pressing the N.B. key. All the functions
are then initialized.
• In the RDS test mode using main unit's keys, the keys
below provides a special operation according to the position where the selector is set. The main unit's keys
except described below and the rotary encoder provide
the normal operation.
KeyOperation
EX. BASS keyPerforms the same operation as for
remote control key "DISPLAY" every time
this key is pressed.
MODE keyPerforms the same operation as for
remote control key "PTY" every time this
key is pressed.
N.B. keyPerforms the same operation as for
remote control key "TA" every time this
key is pressed.
ENTER keySelects the display cyclically in the order
below every time this key is pressed.
2 Set the TUNER ATT to OFF and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT
OFF **" is displayed in the fluorescent display indicator.)
3 Set the TUNER ATT to ON and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT ON
**" is displayed in the fluorescent display indicator.)
* The special display using the ENTER key is continued until
the next operation is carried out. (**: S LEVEL)
When keys other than ENTER are pressed in items 1 to 3
above, the TUNER ATT is set to OFF and the normal display
appears. The operation corresponding to the key that has
been pressed is performed in this case.
2-4. SERIAL TEST MODE
(1) Setting the serial test mode
The unit is put into the serial test mode when a serial code
"TEST ON" is input during the POWER-ON sequence.
In the 16-bit serial test mode, serial code C27FH is input.
• In the serial test mode, all remote control keys and ordinary serial codes are disabled. Only the panel keys perform the same operation as usually.
(2) Canceling the serial test mode
• The serial test mode is canceled to return to the ordinary
mode by inputting a "TEST OFF" code (C27 EH). After
the ordinary mode was returned, the serial mode is
returned to the state before the test mode is entered.
The backup operation is not initialized.
• The serial test mode is also canceled when the AC power
is turned OFF.
(3) Cautions
• The serial test code is prescribed as a 16-bit code only.
• The operations below are inhibited in the serial test mode.
The operations mentioned above cannot be guaranteed
when they are performed in the serial test mode.
• An identical code is output when the serial test mode code
is input.
1 Write data in the unused area of EEPROM, then read the
written data. If the read data is the same as the written
data, "RAM OK" is displayed in the fluorescent display
indicator. If the former is different from the latter, "RAM
NG" is displayed.
4
CIRCUIT DESCRIPTION
FL DISPLAY (FIP9GM6R)
RESET
CE
REMOCON
LEVEL IN
EX. BASS LED
FAN ON
FAN HI
LOW RELAY
HI RELAY
SPEAKER RELAY
(X09) J5
(X14) IC1
(X14) S2
DATA
BUSY
ENC-C
ENC-D
(X14) ED1
(X05) IC2
(X09) IC1
(X14) IC3
u-COM
uPD78045FGF065
9
16
4
1
3
3
1
3
2
2
PLL IC
(LC72131)
KEY MATRIX
SELECTOR ANALOG
SW CONTROL IC
(NJU7313AM)
E2PROM IC
(X24C04)
MULTI CONTROL
ENCODER
(X14) S1
ENC-A
ENC-B
2
VOLUME ROTARY
ENCODER
(X14) IC4
SIGNAL LEVEL
RDS CLOCK
RDS DATA
3
RDS
(X09) IC3
2
ELECTRIC VOLUME
IC (TDA7319)
SD
STEREO
HEAD PHONES
PROTECTION
A MUTE
T MUTE
H. P. MUTE
ATT
A CLASS ON
✽
SERIAL
3. Microprocessor : uPD78045FGF065 (X14 : IC1)
3-1 Microprocessor periphery block diagram
R-SE9/SE9T
Key matrix
64
KS0DSW0 (D25)DSW1 (D26)DSW2 (D29)
63
KS1POWERAUTO / MONOBAND
62
KS2N. B.MODENo. use
61
KS3EX. BASSENTERNo use
No. of : u-COM port No.
60
KR0
59
KR1
58
KR2
5
R-SE9/SE9T
CIRCUIT DESCRIPTION
3-2 Pin description
Pin No.NameI/ODescriptionActive
1~77G~1GOFL grid 7~1—
8VDD—Micro processor power supply (+5V)—
9E2PROM SCLOE2PROM control clock—
10E2PROM SDAI/OE2PROM control data—
11ENC C—Multi control encoder input A—
12ENC D—Multi control encoder input B—
13A CLASS ONOPower ON/OFF control signalH : OFFL : ON
14SEL STBOSelector IC strobe—
15SEL/PLL CLKOSEL/PLL IC control clock—
16SEL/PLL DATAOSEL/PLL IC control data—
17RESETIMicroprocessor resetL : RESET ON
18CEIAC OFF(MAIN POWER) detection SignalL : AC OFF
19PLL DOOIF count data —
20AVSS—A/D power SUPPLY (GND)—
21PLL CEOPLL chip enable control L : CE
22T MUTEOTuner mute signalL : MUTE ON
23STEREOIStereo signal detectionL : STEREO ON
24SDISynchronized signal detection—
25VOL SCLOElectric volume IC control clock—
26VOL SDAOElectric volume IC control data—
27LEVEL INIVolume level input—
✣ 28S.LEVEL(RDS)ISignal level—
29A VDD—A/D power supply (+5V)—
30A VREF—A/D reference voltage(+5V)—
31, 32OSC—32kHz oscillator—
33Vss—Microprocessor power supply (GND)—
34, 35OSC—4.19MHz oscillator—
36S.DATAI/O16bit system data—
37S.BUSYI/O16 bit system busyH : BUSYL : READY
38H.P. MUTEOHead phones mute signalL : ON
39ATTO-6dB attenuatorH : OFF L : ON
40A MUTEOAudio mute signalL : ON
41HIGH RELAYOAMP high relay controlH : ONL : OFF
42LOW RELAYOAMP low relay controlH : ONL : OFF
43SP RELAYOSpeaker relay controlH : ONL : OFF
✣ 44CLK(RDS)IRDS clock—
✣ 45DATA(RDS)IRDS data—
46PROTECTIONIProtection detectionH : ONL : OFF
47REMOCONIRemote control input—
48IC———
49EX. BASS LEDOEX. BASS LEDH : OFFL : ON
50FAN HIOFan speed control signalH : LOWL : HIGH
51FAN ONOFan power supply control signalH : OFFL : ON
52VDD—Microprocessor power supply (+5V)—
53ENCAIVolume encoder in put A—
54ENC BIVolume encoder input B—
55HEAD PHONEIHead phones signal detectionH : ONL : OFF
56, 57NCO——
58~60KR2~KR0IKEY return 2~0H : KEY ON
61~64SEG16~13/KS3~0OFL Segment 6~13 /key scan 3~0H : ON
65~70SEG12~SEG7OFL Segment 12~7H : ON
71V load—FL drive power supply (-30V)—
72~77P6 SEG6~SEG1OFL Segment 6~1H : ON
78NCO——
79, 809G, 8GOFL grid 9, 8—
✣ E/T type only, other types unused.
The RDS PTY AF search always corresponds to a span search of 100kHz. Therefore, a span search of 50 KHz
cannot be performed.
6
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
TUNER
SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
FIG.
1
DISCRIMINATOR
(A)
98.0kHz
1kHz, ±75kHz dev.
60dBµ(ANT input)
Connect a DC
voltmeter
between
Pin 1 and Pin 2
of CN 2.
MONO
98.0MHz
L 31
0V
(a)
L 32
Minimum distortion.
2
DISTORTION
(STEREO)
(C)
98.0MHZ
1kHz, ±68.25kHz dev.
Pilot: ±6.75kHz dev.
60dBµ(ANT input)
(B)
AUTO
98.0MHz
IFT (A1)
Minimum distortion.
(a)
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
AMP
SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
FIG.
POWER: ON
1
IDLE CURRENT
—
Connect a DC
voltmeter across
CN9(L)
CN10(R)
(X09, A/4)
Volume : 0
VR1(L)
VR2(R)
(X09, A/4)
18mV
(b)
SYSTEM
CONTROL
ANTENNA
AM
GND
CD
IN
REC
PLAY
SUPER
WOOFER
PRE OUT
SPEAKERS
( 6 - 16 )
R
TAPE
TAPE
REC
PLAY
MD
MD
AUX
FM75
+
-
IN
L
R
R
L
L
Oscilloscope
Distortion meter
AC voltmeter
Dummy antenna
(A)
(B)
(C)
(D)
AG
AG
FM SG
MPX
AG
FM SG
AM SG
(a)(b)
CN9(L)
CN10(R)
DC voltmeter
18mV
FM SECTION
X05-4622-71 (T TYPE)
AUDIO SECTION (X09-4952-70)
R-SE9/SE9T
ADJUSTMENT
SYSTEM CONNECTIONS
7
Loading...
+ 15 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.