Kenwood r-se7 Service Manual

STEREO INTEGRATED AMPLIFIER/TUNER
stereo integrated amplifier/tuner
on/standby
phones
volume control
pure
input selector
N.B.
pure
enter
band
auto/mono
turning
SPEAKER (6 – 16 )
R
L
SUB WOOFER PRE OUT
FM75
FM300 GND
AM
ANTENA
SYSTEM
CONTROL
R
L
IN IN
CD AUX
REC OUT
PLAY OUT
REC OUT
PLAY OUT
TAPE
MD
R-SE7/SE-7(G)
SERVICE MANUAL
(HM-701)
©1997-10/B51-5373-00 (K/K) 3191
Knob (K29-6744-04)
AC power cord * (E30-)
Panel * (A60-)
Front glass (B10-2373-03)
Power cord bushing (J42-0083-05)
Indicator (B12-0322-04)
Knob (K29-6358-04)
Metallic cabinet * (A01-)
Escutcheon (B07-2367-03)
Escutcheon (B07-2363-04)
Lock terminal board (E20-0476-05)
Panel * (A60-)
Indicator (B12-0320-04)
Knob (K29-6750-03)
Lock terminal board * (E70-)
PRECAUTIONS FOR REPAIR
• For the SERIAL TEST CODE LIST of the circuit description, see Service manual (B51-5210-00) of R-SA7.
Phono jack (E63-1014-05)
• No connection of ground line if disassemble the unit.
• Please connection the ground line on rear panel, PCBs, Chassis and some others.
Phono jack (E63-0046-15)
Phono jack (E63-0047-15)
Rectangular receptacle (E08-0312-05)
* Refer to parts list on page 25.
DISPLAY
SLEEPTAPE
REMOTE CONTROL UNIT
RC-SE9
1 2 3 RANDOM
4 5 6 CLEAR
7 8 9 P.MODE
O.T.E. 0 +10 EDIT
TUNER
BAND
INPUT N.B. MUTE
VOLUME
CONTROL
MD
CDP.CALL
R-SE7/SE-7(G)

CONTENTS / ACCESSORIES

Contents

CONTENTS / ACCESSORIES .................................. 2
CIRCUIT DESCRIPTION............................................3
ADJUSTMENT............................................................8
PC BOARD .............................................................. 10

Accessories

SCHEMATIC DIAGRAM.......................................... 13
EXPLODED VIEW ....................................................24
PARTS LIST..............................................................25
SPECIFICATIONS ......................................Back cover
AM loop antenna (1) (T90-0820-05)
Audio cords (2) (E30-0615-05)
Remote control unit (1) (A70-1154-05) : KM (A70-1155-05) : TE
AM loop antenna stand (1) (J19-3645-05)
System control cord (1) (E30-2628-05)
FM indoor antenna (1) (T90-0182-15) : KM (T90-0806-05) : ET
Batteries (R6/AA) (2)
Battery cover (A09-0374-08)

System configuration

SYSTEM NAME AMP/TUNER CD PLAYER SPEAKER
HM-701 R-SE7 DP-SE7 LS-SE7
2
R-SE7/SE-7(G)
Channel
BAND
E TYPE
Channel
BAND
E TYPE
01chFM87.50MHz
11chFM90.00MHz
02chFM97.50MHz
12chFM98.00MHz
03ch
FM
108.00MHZ
13chFM98.50MHz
04chAM630kHz
14ch
FM
106.00MHz
05chAM990kHz
15chAM531kHz
06chAM1440kHz
16chAM990kHz
07chFM87.50MHz
17chAM1602kHz
08chFM87.50MHz
18chFM87.50MHz
09chFM87.50MHz
19chFM87.50MHz
10chFM89.10MHz
20chFM87.50MHz

CIRCUIT DESCRIPTION

1. INITIAL STATE

(1) AMP-related block
EPOWER OFF ESELECTOR SOURCE TUNER EDISPLAY SELECTOR EN.B. CIRCUIT OFF EA CLASS VOLUME VALUE 1.40 STEP EAB CLASS VOLUME VALUE 7 STEP EPURE MODE NORMAL (AB CLASS) EAUTO POWER SAVE OFF EMULTI CONTROL MODE INPUT SEL.(R-SE9 only)
(2) TUNER-related block
EBAND FM EFREQUENCY Lower-limit value of
FM 87.5 MHz AM 531 kHz
EAUTO/MANUAL AUTO EP.CH MEMORY Last frequency ELast P.CH 01ch E
RDS DATA TABLE MEMORY
(3) TIMER-rated block
ECLOCK STOP (AM12:00) EPROGRAM WORKING MODE OFF
CONTENTS OF PROGR
EO.T.T WORKING MODE OFF
OTT ON TIME AM 7:00
(4) TEST PRESET FREQUENCY
ƒThe initial setting is performed in a following event :
1. When backup memory data is destroyed when reset is applied to the microprocessor.
2. When the power cord is plugged in to the AC wall outlet while pressing the on/standby key.
receiving frequency.
NO DATA
. ON=AM 12:00
OFF=AM 12:00 PLAY MODE=PLAY SELECTOR=TUNER(1ch) REC MODE OFF

2. BACKUP

This function holds the current state of the unit even if the AC power of the receiver is turned OFF.
(1) Operation outline The backup state set command signal (CE) of a microcom-
puter is set low when the AC power is turned OFF. The microcomputer detects the signal and enters the stop state. The microcomputer is reset when the AC power is turned ON. The data for backup state confirmation is checked by reset processing. The microcomputer is initialized when the data was destroyed. If it is not destroyed, the microcomputer is started in the backup state.
EThe data for backup state confirmation is written in a RAM
area.
E The microcomputer is set to the STOP mode so as to
save the power consumption.
EA backup state set command signal is detected by a timer
interrupt of 1 msec.
EThe backup guarantee period is set in a circuit.
(2) Backup state setting
EThe data (A596, 5A69H) for backup state confirmation is
written in a RAM area.
(3) Contents of backup data to be held
[[[ AMP [[[
EPOWER ON/OFF EDISPLAY MODE ESELECTOR SOURCE EN.B. CIRCUIT MODE EA CLASS VOLUME VALUE EAB CLASS VOLUME VALUE EPURE A MODE
[[[ TUNER [[[
ELAST BAND EPRESET CHANNEL/RECEIVING STATION FRE-
QUENCY/PI/TA/PTY/PS
E LAST RECEIVING STATION FREQUENCY AND PRE-
SET CHANNEL (AM/FM)
EPRESET MEMORY data (1ch~40ch) EAUTO/MANUAL
[[[ CLOCK/TIMER [[[
ELAST CLOCK DATA E PROGRAMMED CONTENTS/PROGRAM TIMER WOR-
KING MODE ON/OFF
EO.T.T. SETTING TIME/O.T.T. WORKING MODE
ON/OFF
3
R-SE7/SE-7(G)
CIRCUIT DESCRIPTION

3. DESTINATION LIST OF TUNER

3-1 Destination List of Tuner

Desti-
nation
K1
E1
E3
(RDS)
M
Receive
BAND frequency
range frequency
87.5MHz~
FM
108.0MHz 530kHz~
AM
1700kHz
87.5MHz~
FM
108.0MHz 531kHz~
AM
1602kHz
87.5MHz~
FM
108.0MHz 531kHz~
AM
1602kHz
K2 or E1 is changed the setting "DSW1".
(DSW1=1 : K2, 0 = E1)
0 : NO DIODE 1 : DIODE X : SWITCHING TRANSISTOR
Channel
space
100kHz +10.7MHz 25kHz
10kHz +450kHz 10kHz
50kHz +10.7MHz 25kHz
9kHz +450kHz 9kHz
50kHz +10.7MHz 25kHz
9kHz +450kHz 9kHz
1F reference DSW1 DSW2
PLL
DIODE SW
D518 D519
1 1
0 1
1 0
X 1

4. TEST MODE

4-1. Initializing

The system is initialized when the power is turned on while pressing the on/standby key.
(1) Contents of operation
EAll the functions are initialized.

4-2. AMP test mode using main unit's keys

4-2-1. Entering the AMP test mode
ETurn on the power while pressing the BAND key.
4-2-2. Canceling the AMP test mode
EBy turning off the power, the system is initialized and the
test mode is canceled. 4-2-3. Contents of AMP test mode (1) Automatic on/standby ON
EThe POWER ON state is entered whenever the power is
turned on while pressing the BAND key. All functions are
then initialized and activated in the all-lighting mode.
ESub-clock oscillation diagnosis function
The oscillation diagnosis (existence of oscillation and
measurement of period) of a sub-clock is performed
before the test mode is entered. If the diagnosis result is
OK, the system enters the test mode.
If the diagnosis result is NG, the oscillation of the sub-
clock is diagnosed again. If the result is OK, the system
enters the test mode. If the diagnosis result is continu-
ously NG five times, the system stops with ERR 1 and
ERR 2 displayed. (2) All-lighting mode
EAll the fluorescent display indicators and LED lamps light
when the power is turned on while pressing the BAND
key.
E After that, the all-lighting mode is canceled when any
main unit's key is pressed. The normal display obtained when the selector is set to TUNER then appears.
(3) Others
EThe AMP test mode is not terminated even if the selector
is set to positions other than TUNER.
EIn the AMP test mode, the muting during mode selection
is not controlled. However, the operation during the power-on sequence is the same as the normal operation.
EThe SP protection operation is also the same as the nor-
mal operation.
E In the AMP test mode using main unit's keys, the keys
below provide a special operation according to the posi­tion where the selector is set. The main unit's keys except described below and the rotary encoder provide the normal operation.
(4) When selector is set to TUNER
Key Operation
PURE A key Increments the P.CALL every time this
key is pressed.
N.B. key Decrement the P.CALL every time this
key is pressed.
ENTER key Selects the display cyclically in the order
below every time this key is pressed.
@ Write data in the unused area of E2PROM, then read the
written data. If the read data is the same as the written data, "RAM OK" is displayed in the fluorescent display indicator. If the former is different from the latter, "RAM NG" is displayed.
A Set the TUNER ATT to OFF and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT OFF **" is displayed in the fluorescent display indicator.)
B Set the TUNER ATT to ON and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT ON
**" is displayed in the fluorescent display indicator.) * The special display using the ENTER key is continued until the next operation is carried out. (**: S LEVEL) When keys other than ENTER are pressed in items @to B above, the TUNER ATT is set to OFF and the normal display appears. The operation corresponding to the key that has been pressed is performed in this case.
(5) When selector is set to positions other than TUNER [ENTER key] Every time this key is pressed, master VOL-
UME level is selected cyclically.
INITIALIZE level
Value of Master
VOLUME
MAX 86 16.00
MID 40 8.00 MIN 1 0.20
INITIALIZE 7 1.40
Press the ENTER key.
ìî MAX î MID î MIN ì
Press the PURE A key,
then press the ENTER key.
4
R-SE7/SE-7(G)
CIRCUIT DESCRIPTION
[ AUTO key ] Selects the MUTE operation and equalizer cyclically in the order below for operation display every time this key is pressed.
-- -> MUTE operation -> Minimum -> Maximum ->
ƒ In the operation for except the AUTO key, become pre-
condition equlizer .
ƒPre condition : The equlizer becomes the condition to be
pushed the AUTO key before (include N.B. circuit).
(6) SERIAL TEST CODE LIST
Refer to Service manual (B51-5210-00) of R-SA7 on
page 7. [ BAND key ] Every time this key is pressed, all the displays go off and the normal display is selected cyclically.
ƒPre-condition
--

4-3. RDS test mode using main unit's keys

4-3-1. Entering the RDS test mode
ETurn on the power while pressing the TUNING UP key.
4-3-2. Canceling the RDS test mode
EBy turning off the power, the system is initialized and the
test mode is canceled. 4-3-3. Contents of RDS test mode
EThe POWER ON state is entered whenever the power is
turned on while pressing the TUNING UP key. All the
functions are then initialized.
E In the RDS test mode using main unit's keys, the keys
below provides a special operation according to the posi-
tion where the selector is set. The main unit's keys
except described below and the rotary encoder provide
the normal operation.
Key Operation
CLASS A key Performs the same operation as for
remote control key "DISPLAY" every time this key is pressed.
INPUT SEL. key Performs the same operation as for
remote control key "PTY" every time this key is pressed.
N.B. key Performs the same operation as for
remote control key "TA" every time this key is pressed.
ENTER key Selects the display cyclically in the order
below every time this key is pressed.
B Set the TUNER ATT to ON and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT ON
**" is displayed in the fluorescent display indicator.) * The special display using the ENTER key is continued until the next operation is carried out. (**: S LEVEL) When keys other than ENTER are pressed in items @to B above, the TUNER ATT is set to OFF and the normal display appears. The operation corresponding to the key that has been pressed is performed in this case.

4-4. SERIAL TEST MODE

(1) Setting the serial test mode The unit is put into the serial test mode when a serial code
"TEST ON" is input during the POWER-ON sequence. In the 16-bit serial test mode, serial code C27FH is input.
E In the serial test mode, all remote control keys and ordi-
nary serial codes are disabled. Only the panel keys per-
form the same operation as usually. (2) Canceling the serial test mode
EThe serial test mode is canceled to return to the ordinary
mode by inputting a "TEST OFF" code (C27 EH). After
the ordinary mode was returned, the serial mode is
returned to the state before the test mode is entered.
The backup operation is not initialized.
EThe serial test mode is also canceled when the AC power
is turned OFF. (3) Cautions
EThe serial test code is prescribed as a 16-bit code only. EThe operations below are inhibited in the serial test mode.
The operations mentioned above cannot be guaranteed when they are performed in the serial test mode.
E An identical code is output when the serial test mode
code is input.
@Write data in the unused area of EEPROM, then read the
written data. If the read data is the same as the written data, "RAM OK" is displayed in the fluorescent display indicator. If the former is different from the latter, "RAM NG" is displayed.
A Set the TUNER ATT to OFF and display the S level in
hexadecimal when the ENTER key is pressed. ("ATT OFF **" is displayed in the fluorescent display indicator.)
5
FL DISPLAY (FIP9GM6R)
RESET
CE
REMOCON
LEVEL IN
CLASS A LED
BIAS MID
BIAS HI
LOW RELAY
HI RELAY
SPEAKER RELAY
(X09) J5
(X14) IC2
(X14) S2
DATA BUSY
ENC-C ENC-D
(X14) ED1
(X05) IC2
(X09) IC1
(X14) IC3
u-COM
uPD78045FGF057
9
16
4
1
3
3
1
3
2
2
PLL IC (LC72131)
KEY MATRIX
SELECTOR ANALOG SW CONTROL IC (NJU7313AM)
E2PROM IC (X24C04)
MULTI CONTROL ENCODER
(R-SE9 only)
(X14) S1
ENC-A ENC-B
2
VOLUME ROTARY ENCODER
(X14) IC4
SIGNAL LEVEL RDS CLOCK RDS DATA
3
RDS
(X09) IC3
2
ELECTRIC VOLUME IC (M62420)
SD STEREO HEAD PHONES PROTECTION
A MUTE T MUTE H. P. MUTE ATT A CLASS ON
SERIAL
R-SE7/SE-7(G)
CIRCUIT DESCRIPTION
5. Microprocessor : uPD78045FGF057 (X14 : IC1)

5-1 Microprocessor periphery block diagram

Key matrix
64
KS0 DSW0 DSW1 (D158) DSW2 (D159)
63
KS1 POWER AUTO / MONO BAND
62
KS2 N. B. CIRCUIT
61
KS3 pure A ENTER
6
60
KR0
No. of : u-COM port No.
59
KR1
(R-SE7) INPUT SEL.
(R-SE9) MODE
(R-SE7) TUNING UP
(R-SE9) No. use
(R-SE7) TUNING DOWN
(R-SE9) No use
58
KR2
R-SE7/SE-7(G)
CIRCUIT DESCRIPTION

5-2 Pin description

Pin No. Name I/O Description Active
1~7 7G~1G O FL grid 7~1 —
8 VDD — Micro processor power supply (+5V) —
9 E2PROM SCL O E2PROM control clock — 10 E2PROM SDA I/O E2PROM control data — 11 ENC C — Multi control encoder input A — 12 ENC D — Multi control encoder input B — 13 A CLASS ON O Power ON/OFF control signal H : OFF L : ON 14 SEL STB O Selector IC strobe — 15 SEL/PLL CLK O SEL/PLL IC control clock — 16 SEL/PLL DATA O SEL/PLL IC control data — 17 RESET I Microprocessor reset L : RESET ON 18 CE I AC OFF(MAIN POWER) detection Signal L : AC OFF 19 PLL DO O IF count data — 20 AVSS — A/D power SUPPLY (GND) — 21 PLL CE O PLL chip enable control L : CE 22 T MUTE O Tuner mute signal L : MUTE ON 23 STEREO I Stereo signal detection L : STEREO ON 24 SD I Synchronized signal detection — 25 VOL SCL O Electric volume IC control clock — 26 VOL SDA O Electric volume IC control data — 27 LEVEL IN I Volume level input —
28 S.LEVEL(RDS) I Signal level —
29 A VDD — A/D power supply (+5V) — 30 A VREF — A/D reference voltage(+5V) —
31, 32 OSC — 32kHz oscillator —
33 Vss — Microprocessor power supply (GND) —
34, 35 OSC — 4.19MHz oscillator —
36 S.DATA I/O 16bit system data — 37 S.BUSY I/O 16 bit system busy H : BUSY L : READY 38 H.P. MUTE O Head phones mute signal L : ON 39 ATT O CLASS A control signal H : A CLASS L : AB CLASS 40 A MUTE O Audio mute signal L : ON 41 HIGH RELAY O AMP high relay control H : ON L : OFF 42 LOW RELAY O AMP low relay control H : ON L : OFF 43 SP RELAY O Speaker relay control H : ON L : OFF
44 CLK(RDS) I RDS clock —45 DATA(RDS) I RDS data —
46 PROTECTION I Protection detection H : ON L : OFF 47 REMOCON I Remote control input — 48 IC — — — 49 CLASS A LED O CLASS A LED H : OFF L : ON 50 BIAS MID O Bias control signal MID — 51 BIAS HI O Bias control signal HI — 52 VDD — Microprocessor power supply (+5V) — 53 ENCA I Volume encoder in put A — 54 ENC B I Volume encoder input B — 55 HEAD PHONE I Head phones signal detection H : ON L : OFF
56, 57 NC O — — 58~60 KR2~KR0 I KEY return 2~0 H : KEY ON 61~64 SEG16~13/KS3~0 O FL Segment 6~13 /key scan 3~0 H : ON 65~70 P12 SEG12~SEG7 O FL Segment 12~7 H : ON
71 V load — FL drive power supply (-30V) —
72~77 P6 SEG6~SEG1 O FL Segment 6~1 H : ON
78 NC O — —
79, 80 9G, 8G O FL grid 9, 8 —
E/T type only, other types unused.
The RDS PTY AF search always corresponds to a span search of 100kHz. Therefore, a span search of 50 KHz cannot be performed.
7
R-SE7/SE-7(G)
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
TUNER
SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
FIG.
1
DISCRIMINATOR
(A)
98.0kHz
1kHz, ±75kHz dev.
60dBµ(ANT input)
Connect a DC
voltmeter
between
Pin 1 and Pin 2
of CN 2.
MONO
98.0MHz L 31
0V
(a)
L 32
Minimum distortion.
2
DISTORTION
(STEREO)
(C)
98.0MHZ
1kHz, ±68.25kHz dev.
Pilot: ±6.75kHz dev.
60dBµ(ANT input)
(B)
AUTO
98.0MHz
IFT (A1)
Minimum distortion.
(a)
NO.
ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
AMP
SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
FIG.
POWER: ON SELECTOR : AUX
1
B CLASS
IDLE CURRENT
Connect a DC
voltmeter across
CN1(L) CN2(R)
(X09, A/7)
PURE A : OFF
Volume : 0
VR1(L)
VR2(R)
(X09, A/7)
20mV
(b)
SPEAKER (6 – 16 )
R
L
SUB WOOFER PRE OUT
FM75
FM300 GND
AM
ANTENA
SYSTEM CONTROL
R
L
IN IN
CD AUX
REC OUT
PLAY OUT
REC OUT
PLAY OUT
TAPE
MD
Oscilloscope
Distortion meter
AC voltmeter
Dummy antenna
(A)
(B)
(C)
(D)
AG
AG
FM SG
MPX
AG
FM SG
AM SG
(a) (b)
CN1(L) CN2(R)
Dc voltmeter
20mV
FM SECTION SELECTION :FM
X05-4622-71 (E/T TYPE)
AUDIO SECTION (X09-469x-xx)

ADJUSTMENT

SYSTEM CONNECTIONS
8
R-SE7/SE-7(G)

PARTS DESCRIPTIONS

9
Loading...
+ 18 hidden pages