Kenwood KGC-9044 User Manual

KGC-9044
© B64-1423-00 (E) (MC) 00/2 1 99/12 11 10 9 8 7 6 5 4 3 2 1
11 BAND GRAPHIC EQUALIZER
INSTRUCTION MANUAL

Contents

— 2 —
Before use
Safety precautions ..................................................................3
Buttons and Display
.....................................................4
Equalizer operations
KBS (Kenwood Built-in Sound) ................................................4
Equalizer Adjustment ..............................................................5
Equalizer Curve Memory.........................................................5
Other operations
Menu System..........................................................................6
Spectrum Analyzer Display Selection .....................................7
Automatic Dimmer Function ...................................................7
Demonstration Function..........................................................7
Input Sensitivity Adjustment ...................................................7
Theft Deterrent Faceplate .......................................................8
Installation
Accessories.............................................................................9
Installation Procedure..............................................................9
Connections ..........................................................................10
Installation .......................................................................... 10
Troubleshooting guide
................................................13
Specifications
................................................................14
— 3 —

Safety precautions

To prevent injury and/or fire, take the following precautions:
• Insert the unit all the way until it is fully locked in place. Otherwise it may fly out of place during collisions and other jolts.
• When extending the battery or ground. cables, make sure to use automotive-grade cables or other cables with an area of
0.75mm
2
(AWG18) or more to prevent wire deterioration and damage to the cable coating.
• To prevent short circuits, never put or leave any metallic objects (e.g., coins or metal tools) inside the unit.
• Make sure not to get your fingers caught between the faceplate and the unit.
• If the unit starts to emit smoke or strange smells, turn off the power immediately and consult your Kenwood dealer.
• Be careful not to drop the unit or subject it to strong shock.
The unit may break or crack because it contains glass parts.
2WARNING
To prevent damage to the machine, take the following precautions:
• Make sure to ground the unit to a negative 12V DC power supply.
• Do not open the top or bottom covers of the unit.
• Do not install the unit in a spot exposed to direct sunlight or excessive heat or humidity. Also avoid places with too much dust or the possibility of water splashing.
• Do not set the removed faceplate or the faceplate case in areas exposed to direct sunlight, excessive heat or humidity. Also avoid places with too much dust or the possibility of water splashing.
• Do not subject the faceplate to excessive shock, as it is a piece of precision equipment.
• To prevent deterioration, do not touch the terminals of the unit or faceplate with your fingers.
• When replacing a fuse, only use a new one with the prescribed rating. Using a fuse with the wrong rating may cause your unit to malfunction.
• To prevent short circuits when replacing a fuse, first disconnect the wiring harness.
• Do not place any object between the faceplate and the unit.
• During installation, do not use any screws except for the ones provided. The use of improper screws might result in damage to the main unit.
2CAUTION
• If you experience problems during installation, consult your Kenwood dealer.
• If the unit does not seem to be working right, try pressing the reset button first. If that does not solve the problem, consult your Kenwood dealer.
Cleaning the Faceplate Terminals
If the terminals on the unit or faceplate get dirty, wipe them with a dry, soft cloth.
Cleaning the Unit
If the front panel gets dirty, turn off the power and wipe the panel with a dry silicon cloth or soft cloth.
Do not wipe the panel with a stiff cloth or a cloth dampened by volatile solvents such as paint thinner and alcohol. They can scratch the surface of the panel and/or cause the indicator letters to peel off.
2CAUTION
NOTE
PREOUT
4V
DISP
60 120 250 380 500 750 1k 2k 4k 8k 16k
MENU
SPEANA
KGC-9044
1
2
3
PATTERN
9
SPECTRUM ANALYZER
SUBWOOFER LEVEL
ADJUSTABLE
GRAPHIC EQUALIZER
S.A
DEMO
Reset button
Four types of loudness levels and equalizer curves for rock, pops, vocal, and flat music genre have been preset. You can call up an equalizer curve for each genre at the touch of a button.
Switching between KBS1, KBS2 and USER:
Press the EQ button. Each time you press the EQ button, the function changes from
KBS1 to KBS2 to USER.
3 KBS1 3 KBS2 3 USER
When KBS1 or KBS2 or USER is ON, the respective KBS1 or KBS2 or USER indicator lights. Initially, KBS1 is turned on.
Selecting an equalizer curve preset in KBS1 or KBS2 or USER:
Press any one of buttons 1 to 3. The selected curve is set and displayed, and the sound quality is changed accordingly.
ROCK: For rock sounds, POPS: For pops sounds, VOCAL: For vocal sounds, LOUD1-3: Loudness curves, PRESET1-3: User preset curves,
Cancelling equlizer effects:
Press the EQ button for more than one second to change the flat curves("FLAT").
NOTE
2
1
— 4 —

Equalizer operations

PREOUT
4V
EQ
60 120 250 380 500 750 1k 2k 4k 8k 16k
MENU
SPEANA
KGC-9044
1
2
3
PATTERN
9
SPECTRUM ANALYZER
SUBWOOFER LEVEL
ADJUSTABLE
GRAPHIC EQUALIZER
S.A
DEMO
2
3
u
d
#1-3
S.A
MENU
EQ
No. indicatorKBS indicator

KBS (Kenwood Built-in Sound)

"ROCK" "POPS"
"VOCAL"
"LOUD1" "LOUD2" "LOUD3"
"PRESET1" "PRESET2" "PRESET3"
Equalizer curve /Spectrum analyzer display
USER indicator

Buttons and Display

Release button
MENU indicator
DEMO indicator
Title display
KBS / USER indicator
No. indicator
Loading...
+ 9 hidden pages