Kentrox DataSmart DSU, DataSmart 486, DataSmart CSUs, DataSmart E1, DataSmart FE1 User Manual

...
DataSMART ® 486 and 488
E1/FE1 Frame Monitoring DSU/CSUs
DataSMART E1/FE1 Frame Monitoring DSU/CSUs provide comprehensive, easy­to-use, end-to-end circuit monitoring to improve Frame Relay network performance.
E1/FE1 Frame Monitoring
DSU/CSUs
With DataSMART Frame Monitoring DSU/CSUs, service providers and network managers have the tools to deliver reliable, high-performance Frame Relay services. Frame Monitoring DSU/CSUs help verify Service Level Agreements between the PTT and customer, match bandwidth to application needs, and isolate performance problems to the LAN, the WAN, or the local loop.
DataSMART DSU/CSUs maximize your network uptime with convenient management features, such as in-band access for simplified remote management. Each DSU/CSU includes an integrated Ethernet port and a front-panel LCD for easy local management, along with standards-based SNMP management.
DataSMART E1/FE1 Frame Monitoring DSU/CSUs, teamed with FrameVision Reporter software, deliver the tools and information necessary to ensure ongoing savings – and a quick return on investment.
Provide end-to-end circuit monitoring for Frame Relay networks
n Identify when bandwidth
adjustments are needed
n Isolate the source of slow
network performance: the LAN, local loop, or WAN
n G.704 performance monitoring
for E1 services
n X.21/V.35 data port available
for a variety of equipment
n Add/drop voice port available
for voice and data traffic integration
n Standards-based, in-band
management with SNMP
n Easy local management with
10Base-T access and front-panel LCD
n Free DataSMART
and Alarms Utility software
n 5-year manufacturer’s
warranty ensures reliability
®
Installer
DataSMART
E1/FE1 Frame Monitoring DSU/CSUs
DataSMART E1/FE1 Frame Monitoring DSU/CSU Product Portfolio:
PHYSICAL INTERFACE PROTOCOLS USER PORTS
NETWORK USER NETWORK OR VIDEO VOICE RATES
DataSMART 486 E1 X.21 Clear Channel 1 0 Nx64k, Single-Port FE1 V.35 Frame Relay 2.048 Mbps
DataSMART 488 E1 X.21 Clear Channel 1 1 Nx64k, Single-Port FE1 V.35 Frame Relay 2.048 Mbps Add/Drop EIA-530
The DataSMART 486 and 488 support FrameVision Reporter software to deliver key performance measurements on individual customer circuits.
The DataSMART 488 integrates voice and data traffic onto a single E1/FE1 line.
With in-band management and local Ethernet connectivity, the DataSMART 486 and 488 can be managed easily from a remote or local site. The management system can be located anywhere on the business network.
EIA-530 RS449
RS449 E1/FE1
DATA
Verify Frame Relay performance
DataSMART Frame Monitoring DSU/CSUs help you isolate circuit availability problems and measure round-trip delay from DSU to DSU.
You can see the exact time a service outage occurred and how long it lasted, to determine if it was an isolated incident or a chronic problem.
You can monitor bandwidth utilization at the port and virtual circuit to deter­mine the right bandwidth to meet your application requirements.
Advanced management and diagnostics
The DataSMART DSU/CSUs have advanced management features that enable you to take active control of your network, such as in-band SNMP management and an integrated Ethernet port. Comprehensive E1 diagnostic tools help you identify and resolve performance issues in the Frame Relay local loop before they affect service. With the DataSMART, you can remotely configure your units, and receive SNMP traps for important network events.
Standards-based Management
The DataSMART embedded SNMP agent supports SETs, GETs and Traps, as well as standard MIBs, such as MIB II and the E1 MIB. And for compre­hensive control, an enterprise MIB supports all available functions. These MIBs are available on the ADC Kentrox web site (www.kentrox.com).
DataSMART Installer for Windows
Free with each unit, DataSMART Installer software is an intuitive, Windows-based utility that dramatically reduces setup time.
Alarms Utility
Downloadable free from www.kentrox.com, Alarms Utility monitors the entire network for inter­face and device errors, posting them to the event log in an HP OpenView management system. Customer icons uniquely identify all ADC Kentrox devices for easy recognition by the Network Node Manager.
Specifications
E1/FE1 Frame Monitoring DSU/CSUs
NETWORK INTERFACE
Line Rate E1 (2048 Kbps) + 50 ppm Framing G.704 Line Code HDB3 Protocol Clear Channel
Line Impedance
Mechanical
Lightning Protection
TERMINAL INTERFACE (DataSMART 488)
Line Rate E1 (2048 Kbps) + 50 ppm Framing G.704 Line Code HDB3 Protocol Clear Channel (DS0) Line Impedance
Mechanical
DATA PORT INTERFACE
Bit Rate Nx64 kbps (N=1...31) Electrical V.35 compatible
Mechanical
MANAGEMENT
Control Ports
Ethernet Port
SNMP Agent
In-band From network or router
LCD Front panel display of unit status
Frame Relay
10 at 1024 KHz
120 +
10 at 1024 KHz
75 + DA15 socket for 120
Adapter for 75 BNC
120interface withstands lightning surges defined per FCC Part 68, and unit recovers
10 at 1024 KHz
120 +
10 at 1024 KHz
75 + DA15 socket for 120
Adapter for 75 BNC
X.21 via adapter V.11/X.27/EIA-530
DB25 socket
DCE and DTE EIA-574 DE9 socket Daisy chain
38.4 kbps maximum English menus Async ASCII or SLIP/PPP
10Base-T RJ45 socket Transmit and receive LEDs
MIB II (RFC 1213) DS1/E1 MIB (RFC 1406) Frame Relay MIB (RFC 1315) Enterprise MIB* TELNET server Responds to Ping Security filters (for IP source addresses) Up to 10 SNMP Trap hosts
Shared or dedicated VC Frame Relay or ATM DXI
Front panel configuration of unit
ALARMS
Traps SNMP Traps via SLIP/PPP, Ethernet or ASCII Transmitted out async control port
in-band
FRAME RELAY CIRCUIT MANAGEMENT
Methodology
Virtual Circuit (VC) Traffic
VC Status
VC Traffic Detail Measurement Intervals
VC Delay Measurements
VC Delay Diagnostics
Frame Relay Performance Thresholds
Frame Relay Statistics
Reports Frame statistical
Non-intrusive, in-band
Group Measurements: % bandwidth utilization, kbps, delays, VC status (24 hour)
Detail: Frames, octets, kbps, delay measurements, VC status
Up, down, BECN set, FECN set, DE set, bandwidth utilization threshold exceeded, delay threshold exceeded
Current/previous second; cur/prev 15 min; cur/prev 2 hour; cur 24 hour; previous 7 complete days, 12 2-hour intervals for current day
Maximum observed delay, average delay, attempts made, measurement packets lost Automatic delay measurements for up to 64 active VCs
Round-trip VC delay via in-band
User configurable Access bandwidth utilization Round-trip delay
Non-integral number of octets Invalid header address Invalid HDLC FCS Aborted frames FPING responses lost (system total)
Frame group (VC summary) Frame individual (VC detail) Frame VC utilization Burst: data sent above CIR and above
excess burst rates
LOCAL LOOP DIAGNOSTICS
Loop Tests
Line Test Codes
Data Test Codes
BERT Tester
Line loopback Payload loopback Data port loopback
23
-1, 215-1, QRS, 3-in-24, 1-in-8, All 1s,
2 All 0s
511, 2047
Independent BERT on all test codes
LOCAL LOOP PERFORMANCE MONITORING
Data Storage
Monitors Network and terminal interface Reports Based on G.821 for performance
Last 24 hours of data in 15 minute increments; last 7 days of data in 24-hour increments
Far end Alarm history Network interface statistical Terminal interface statistical
(add/drop only)
DIAGNOSTICS
LEDs Power/fail
Loop Tests
E1 Data port transmit Data port receive Data port CTS Data port RTS
Local loopback Data terminal loopback Terminal interface loopback
(add/drop only)
STANDARDS
EN60590 EN55022 Class B EN50081-2 ITU G.703, G.704, G.821 BABT NTR4, CTR 12, CTR 13
REGULATORY (Call for current status)
ACN Australian Communications Authority and BABT NTR 4
CE 0682 TUV GS
Spectrum Management
_X_
ENVIRONMENT
Operating 0° to 50° C
Storage -20° to 66° C
5% to 90% RH, non-condensing
5% to 65% RH
POWER
AC 85-265 VAC, 47-63 Hz, 8W
PHYSICAL
Usage Desktop or tray mount Dimensions
Weight 1.14 kg (approx.)
*MIB files available at www.kentrox.com.
19.68 cm W x 4.32 cm H x 29.21 cm D
DataSMART
E1/FE1 Frame Monitoring DSU/CSUs
DataSMART 486 E1/FE1
Frame Monitoring DSU/CSU
1
3 42
DataSMART 488 E1/FE1 Add/Drop
Frame Monitoring DSU/CSU
Ordering Guide
Description Model No.
Frame Monitoring DSU/CSUs
DataSMART 486 E1/FE1 72486 Frame Monitoring DSU/CSU DataSMART 488 E1/FE1 Add/Drop 72488 Frame Monitoring DSU/CSU
Mounting Accessories
Mounting Tray, 1 Stand-alone unit 78031
Management and Reporting Software
FrameVision Reporter 70304 DataSMART Installer 70305 Alarms Utility 70451
*Call for availability.
*
1 1
3 42
Back Panel & Cable Guide To Network and Terminal Equipment
1
930xx091 DA15P to DA15S 930xx101 DA15P to Stub 930xx121 DA15P to RJ48C Modular Plug 930xx131 DA15P to DA15P 77892 DA15P to RJ48C Socket Adapter 77895 DA15P to 2 x 75 ohm Socket Coaxial
960xx009 BNC Plug to BNC Socket 960xx010 BNC Plug to BNC Plug 93005132 DA15P to DA15P, Crossover 77993003 DA15P to Barrier Strip Adapter
2
To Control Terminal
95006022 DE9S to DE9P, 6 ft. (2.4 m) 95005023 DE9S to DB25P, 5 ft. (2 m) 93001211 DE9P to RJ48, Cisco 2500 SLIP
Adapter
To Control Port
78899 DE9S to RJ45 Adapter 78891 DataSMART Installation Kit
Copyright 1998, ADC Kentrox. An Equal Opportunity Employer. DataSMART is a registered trademark and FrameVision is a trademark of Kentrox Industries, Inc., dba ADC Kentrox. ADC Kentrox is a registered trademark of ADC Telecommunications, Inc. These trademarks are registered in the U.S. Patent and Trademark Office and may be registered in other countries. All other trademarks mentioned are the property of their respective companies. Specifications published here are current or planned as of the date of publication. ADC Kentrox reserves the right to change specifications without prior notice. You may verify product specifications by contacting any of our offices.
To Data Equipment
3
V.35
95010054 DB25P to MRAC34P, 10 ft. (4 m) 95010073 DB25P to MRAC34P, tail circuit timing
95001074 DB25P to MRAC34S, 1 ft. (0.4 m) 78904 DB25P to MRAC34S Adapter
X.21
78902 DB25P to DA15S, X.21 Adapter 95010061 DB25P to DB25P, 10 ft. (4 m) 95010058 DB25P to DB25P, tail circuit timing (DCE
95010066 DB25P to DC37P (EIA-530 to RS449)
To 10Base-T LAN
4
95007077 RJ45 Plug to RJ45 Plug,
95007078 RJ45 Plug to RJ45 Plug, Crossover,
NOTE: xx denotes length of cable, contact factory for available lengths. DA, DB, DC, DE designate the size of the shell which encapsulates the cable connector.
P = Plug (male); S = Socket (female).
(DCE to DCE)
to DCE)
Cat. 3 UTP, 7 ft. (2.8 m)
Cat. 3 UTP, 7 ft. (2.8 m)
Worldwide Sales Offices
Corporate
Headquarters +1-503-643-1681
Australia +61-2-9975-1499
Belgium +32-2-712-6555
Canada +1-905-629-3104
China +86-10-65007001
Germany +49-211-53065530
Korea +82-2-333-8989
Latin America +1-310-640-2922
Singapore +65-227-5621
United Kingdom +44-1705-481691
ADC Kentrox 14375 NW Science Park Drive Portland, Oregon 97229 (800) 733-5511 (503) 643-1681
FAX (503) 641-3341
Web Site www.kentrox.com
E-mail info@kentrox.com
Pre-sales Support (800) 733-5511
Literature Hotline (800) 232-5879
8/98 05-04-007
Loading...