Kenton LD2Pro User Manual

Page 1
LD
LD----2
LDLD
2
22
Level display unit
Operating manual
Page 2
CONNECTIONS
MIDI In
Plug your MIDI pedal, controller or sequencer`s MIDI Out into here. The LD-2 has no MIDI thru, so it will need to be at the end of your MIDI chain, or fed from a thru box. Note that if you are using several MIDI devices “daisy chained” together, data may get corrupted to the devices at the end of the line. Best practise is to use a “Thru Box” if you are using more than 3 devices chained together.
DC IN 9-12V
Plug the power adapter into here. The unit will take an adapter with an output in the range of 9-12V either regulated or unregulated. The socket is a 2.1mm type with centre positive. Do not use an adaptor with an output voltage higher than 12V, and the LD-2 must not share an adaptor with any other device. Failure to observe this will invalidate your warranty, and will probably damage the other device, the LD-2 and/or the power supp
ly.
DISPLAY
The display has two types of readout. Firstly numbers are displayed in numeric format. This can be either 0-127 as used by MIDI or alternatively 0-20. Secondly, there is a 20 segment bar reaout where a value of zero will show no bars, and a value of 127 will show all bars, with intermediate values showing a proportionate number of bars.
USING THE LD-2
First connect the supplied power supply to the DC input socket on the left side of the unit, then connect your MIDI signal cable to the MIDI In socket.
When power is applied to the LD-2, the words KENTON LD-2 will scroll across the display, then three horizontal bars will show, indicating that no valid message has been received yet.
The factory default is to display the value of any message sent by controller #7 on MIDI channel #1.
CHANGING THE CONTROLLER & MIDI CHANNEL
To change the MIDI message being displayed, use a small screwdriver or matchstick (or similar) to press (then release) the learn button. The display will then show the letters “L r n” for learn. The learn button is deliberately recessed to prevent accidental re-assignment.
The next controller (or program change) message received on any MIDI channel will be stored, so that any subsequent message received from that controller on that MIDI channel will be displayed both on the 7 segment display, and on the bargraph.
The controller (or program change) and channel information is saved in non-volatile memory, so the unit will “remember” its assignments for the next time it is used.
Because MIDI program changes are either displayed 0 to 127 or 1 to 128, it is possible to select either mode.
1) press the recessed button to put the unit into learn mode
2) press the program change button on your synth with the number "2" on it. This will either be the 2nd or 3rd button depending which scheme your keyboard uses.
- if your synth goes 0-127 then the display will show 0 (zero) when you do this to indicate 0-127 mode
- if your synth goes 1-128 then the display will show 1 (one) when you do this to indicate 1-128 mode
- if the display is not the mode you want, just use the next button up to program
The unit will then be ready to display program numbers on the MIDI channel you used to program it with. LD-2s with firmware earlier than #1126 cannot display program changes.
2
Page 3
CHANGING THE NUMERIC DISPLAY MODE
To change the display mode to 0-20 or back to 0-127, hold the learn button in for a few seconds. At first it will display L r n (learn), but after several seconds it will show 20 for 0-20 mode or 127 for 0-127 mode. If you continue to hold the button in, it will continue to toggle between the two modes. When the mode you want to use is displayed, release the button and the unit will be ready to use again. This setting is also stored in the non-volatile memory. If you learn program change, then display mode will be reset to 0-127.
LIST OF CONTROLLER NUMBERS
Controller Number Control Function
0 Bank select MSB 1 Modulation wheel or lever 2 Breath controller 3 Undefined 4 Foot controller 5 Portamento time 6 Data entry MSB 7 Main volume 8 Balance 9 Undefined 10 Pan 11 Expression controller 12 Effect control 1 13 Effect control 2 14-15 Undefined 16-19 General purpose controllers (1-4) 20-31 Undefined 32-63 LSB for controllers 0-31 64 Damper pedal (sustain) (Hold 1) 65 Portamento on/off 66 Sostenuto 67 Soft pedal 68 Legato footswitch (val 0-63=normal 64-127=legato) 69 Hold 2 70 Sound controller 1 (default=sound variation) 71 Sound controller 2 (default=timbre/harmonic content) 72 Sound controller 3 (default=release time) 73 Sound controller 4 (default=attack time) 74 Sound controller 5 (default=brightness) 75-79 Sound controllers 6-10 (no defaults) 80-83 General purpose controllers (5-8) 84 Portamento control 85-90 Undefined 91 Effects 1 depth (formerly external effects depth) 92 Effects 2 depth (formerly tremolo depth) 93 Effects 3 depth (formerly chorus depth) 94 Effects 4 depth (formerly celeste (detune) depth) 95 Effects 5 depth (formerly phaser depth) 96 Data increment 97 Data decrement 98 Non-registered parameter number LSB 99 Non-registered parameter number MSB 100 Registered parameter number LSB 101 Registered parameter number MSB 102-119 Undefined 121-127 Reserved for channel mode messages
3
Page 4
FACTORY DEFAULTS
If you want to reset your LD-2 to its factory default settings, you can do so by applying power to the unit whilst holding the learn button pressed.
`Fd` (factory defaults) will momentarily be displayed when this has been done.
The factory default settings are: MIDI channel #1 Controller #7 (MIDI volume) Numeric display in 0-127 mode
SPECIFICATIONS
Power Input 9-12V DC – mains adaptor supplied (or phantom power from LD-3 or 4
Power 300mA, 2.1mm plug (centre positive)
MIDI In only
Display 3 x 7 segment display and 2 x 10 segment bargraph
Weight 285 gms
Dimensions 119 x 54 x 40 mm
Non-volatile memory EEPROM (no back-up battery required)
WARRANTY
The LD-2 comes with a 12 month (from purchase date) back to base warranty, (i.e. customer must arrange and pay for carriage to and from Kenton Electronics).
Kentron Electronics Limited
Brookfarm House, Station Road, South Wimbledon, London, SW19 2LP, UK
Tel: +44 (0)20 8544 9200 Fax: +44 (0)20 8544 9300
sales@kenton.co.uk www.kenton.co.uk
TH
rev# 1127 e. & o. e. 29
July 2008
4
Loading...