KENT PRIME TC Instruction Handbook Manual

Page 1
E:\LnK_Kent_2014\Mannual_2014\KENT Prime TC manual_2014 Size: 5.5” 8.25” dt. 19-05-14 job no. 222×
May 2 014
For customer complaints, contact customer care officer at:
Call Toll-Free: 1800 100 1000 or Fixed line: +91-120-4669666 E-mail: service@kent.co.in
A-2, Sector-59, Noida, UP-201 309, India
A-2, Sector-59, Noida, U.P.-201 309, India Ph.: +91-120-3075075 E-mail: sales@kent.co.in Website: www.kent.co.in
KENT RO SYSTEMS LTD.
Manufactured by:
Khasra No. 93, Village-Bantakhedi, Tehsil-Roorkee, District-Haridwar, Uttarakhand-247 668, India
KENT RO SYSTEMS LTD.
ISO 9001:2008 C e r t i f i e d
GOLD MEMBER
Instruction Handbook for
Installation, Operation and Maintenance.
Kent Deta Hai
System Tested and Certified
by WQA to NSF/ANSI 58 for the reduction of Barium, Fluoride, Lead, Nitrate, Nitrite, Pentavalent
Arsenic (<300ppb) and TDS.
System Tested and Certified
by WQA to NSF/ANSI 58 for the reduction of Barium, Fluoride, Lead, Nitrate, Nitrite, Pentavalent
Arsenic (<300ppb) and TDS.
8 9 06 01 9 9 40 6 84 >
WA LL MO U NT ED RO P UR IF IE R
TM
Mineral RO
KENT Prime TC's design is registered vide registration no.
© 2005 - 2012 KENT RO SYSTEMS LTD, the process & purifier is patented vide patent no. 199716.
Page 2
Welcome
to KENT
Dear Customer,
At the outset, allow us to thank you for your trust in
water purifiers. We take pride in our reputation for product
quality and industry proven performance. We are certain
TM
that your decision to own a Prime TC Mineral RO
water purifier will go a long way towards keeping you and
your family in good health. We are confident that you will
be satisfied with its performance and that it will serve your
need for safer and cleaner drinking water without any
compromise.
This guide will help you in getting the best out of your water
purifier. Please go through this booklet to familiarise
yourself with its operation and maintenance.
You can look forward to years of trouble free service. To
ensure that the warranty of your water purifier is effective,
it is important that you fill up the enclosed warranty card
and mail us the installation report within 15 days of
purchase. In case you need any further information,
contact your nearest dealer / branch.
Best Wishes
KENT
KENT
KENT
KENT RO SYSTEMS LTD.
Table of Contents
1. 1
2. Salient Features 1
3. Items in the Box 1
4. Important Instructions 2
5. Reverse Osmosis Process 3
6. UV Process 3
7. Water Flow Diagram 4
8. Electrical Circuit Diagram 4
9. UV Fail Alarm 5
10. Filter Change Alarm 5
11. Computer Controlled Operation 5
12. Automatic Operation 5
13. Installation Instructions 6
14. TDS Adjustment 7
15. Starting Up the Purifier 7
16. Recommended Uses of Rejected Water 7
17. Maintenance 8
18. Technical Specifications 9
KENT TECHNOLOGY - A Breakthrough in Water Purification
Page 3
1
TM
Presenting the Prime TC Mineral RO Water Purifier; it uses futuristic and state-of-the- art technology to provide pure and healthy drinking water.
TM
The heart of Prime TC Mineral RO Water Purifier is a Reverse Osmosis membrane
having capillaries as small as .0001 microns that reduces even dissolved impurities (salts and
heavy metals) and even converts hard water to sweet and pure drinking water. Prime TC
TM
Mineral RO Water Purifier also allows the user to control the Total Dissolved Solids (TDS)
level in purified water.
KENT
KENT
KENT
KENT TECHNOLOGY - A Breakthrough in
Water Purification
n n
n
n
n n
n
n
n
n
n
n
n
n
Double treatment by RO + UV processes Filter Change Alarm to indicate filter
replacement time
Inb uilt TDS Co ntr oll er that al lows adjustment of TDS level in purified UV Fail Alarm to indicate failure in UV water system
Ideal for municipal, Corporation Water RO Membrane fused inside membrane
housing to prevent tampering
Wall mounted design; best suited for Indian homes and offices Vertically mounted SMPS for protection
from water
9 ltrs. storage tank with water level indicator Use of push-fit fittings for leakage and
maintenance free performance
Fully automatic operation with auto-on and auto-off function
New eye appealing design
Com pute r cont rol led ope rati ons fo r
ABS construction for corrosion free use
enhanced purity and long life
TM
Salient Features of KENT Prime TC Mineral RO Water Purifier
1.
2.
3.
4.
5.
6.
TM
Prime TC Mineral RO Water Purifier : 01 No.
3-Way Connector : 01 No.
S.S. Ball Valve : 01 No.
Food Grade Pipe (White & Blue) : 03 meters each
Instruction Manual : 01 No.
Screws & Plastic Inserts : 02 Nos. each
KENT
Items in the Box
Important Instructions
2
Water in
The maximum distance between the water source and the purifier should not be more than 3 meters.
Make sure that the purifier is connected to cold water supply only.
Do not try to service the purifier on your own. Instead, call service technician for help.
To keep the storage tank clean, it should be drained once in 15 days.
10 M
Water Source
“Make sure that the reject water pipe is not placed at a level higher from the purifier, otherwise reject water may flow backwards into the purifier”.
Reject Water
Drain
Avoid exposure to direct sunlight and installation in damp areas.
Do not confine the purifier in a cabinet.
Avoid sharp bends in the pipe. Do not bend or block the reject water pipe.
In case of not using the purifier for more than two days, kindly switch off the power supply and drain the storage tank.
The buzzer sound indicates a fault in the purifier. In case you hear an audible alarm, please take a corrective action or call service engineer for help.
Page 4
The Reverse Osmosis process, also known as hyper filtration, is the finest filtration process known till date. The process ensures removal of particles as small as ions from a solution. Reverse Osmosis uses a semi­permeable membrane to remove salts from potable / brackish water. In Reverse Osmosis, water pressure applied to the concentrated side forces the process of osmosis into reverse. Under enough pressure, treated water is ”squeezed” through the membrane from the concentrated side to the diluted side. Salts dissolved in water as charged ions are repelled by the RO membrane. The rejected impurities on the concentrated side of the membrane are washed away in a stream of waste water and thus do not get accumulated as in a traditional filter.
UV Process
The UV light has shorter wavelength (higher energy) than the visible light. It is called ultra­violet because it is just beyond violet light in the light spectrum. Technically, the ultra-violet light is defined to be any wavelength of light, which is shorter than 400 nanometer.
UV rays, which penetrate into the micro-organisms, are absorbed by the DNA of the pathogen in the water. The DNA is altered in such a way that the pathogen cannot reproduce itself. Thus, it is essentially killed and cannot cause infection. This process of DNA modification is called inactivation.
Reverse Osmosis Process
700400
Wavelength(nm)
UVB
280-315
UVA
315-400
UVC
200-280
X-Rays
Ultraviolet
Visible
Infrared
Microwaves Radio
3
Mar keted b y: KENT RO SYS TEMS LTD.
A-2 , Secto r-59, N oida, U.P.-2 01 309, India
Ph. : +91-1 20-307 5075
E-m ail: se rvice@ kent. co.in W ebsite : www. kent .co.in
Cus tomer c are: +9 1-120 -46696 66
KENT
TM
PRIME TC MINERAL RO WATER PURIFIER
Page 5
7
Terms & Conditions of Warranty
KENT warrants all new products manufactured by it to be free from defects in material and workmanship under normal usage and service from the date of purchase as under:
1. The Warranty period commences from the date of installation by the first end-user. During this Warranty period of one year, KENT Purifiers or its Authorised Service Provider (ASP) will replace or repair any part of KENT Purifiers, that in the opinion of KENT Purifiers or its ASP, would be defective in operation due to faulty material or workmanship (i.e. manufacturing defects) with the exception of consumables such as Sediment Filter, Carbon Filter and RO/UF Membrane. However, if the RO/UF Membrane gets clogged within first one year and/or if the filters get clogged within first six months, they shall be cleaned / repaired / replaced at no extra charge.
2. The product's plastic body is not covered under Warranty and hence, it must be handled with care to guard against breakage.
3. The original purchaser of the unit can avail services under Warranty at the point of sale, by producing the damaged part(s) along with the original invoice.
4. This Warranty is void if the unit is not operated under normal municipal water or well water conditions or is subjected to the temperature above 40°C.
5. Product returned to KENT Purifiers or its ASP for Warranty examination must be shipped freight prepaid.
6. KENT Purifiers or its ASP shall not be held liable for claims exceeding the cost of repair of the defects in workmanship.
7. Thi s Warr anty Agree ment shal l n ot b e interpreted to render KENT Purifiers or its ASP liable for injuries or damages of any kind - direct, consequential or contingent to persons or property.
8. KENT Purifiers or its ASP shall not be held responsible by representative or buyer for failure to abide by any of the obligations of this Warranty Agreement if such failures are the result of circumstances of Forces Majeures: such as, but no t li mit ed to , f lo od s, ea rt hqu ak es, transportation strikes, labour disputes with outside suppliers or any other conditions beyond the control of KENT Purifiers or its ASP.
9. KENT Purifiers or its ASP shall not be held liable for repair or alterations made without prior written approval; for products clogged by suspended matter, precipitates or biological growth; or for failures resulting from the lack of proper maintenance.
10. KENT Purifiers or its ASP cannot and shall not be held liable for any sickness or illness due to the consumption of drinking water from any water purifier supplied by KENT Purifiers, since KENT Purifiers or its ASP does not have any control over the maintenance and usage of water purifier.
11. This Wa rran ty A gree ment ex clud es a ll products/component parts or damage to any part of this water purifier which, in the opinion of KENT Purifiers or its ASP, have been subjected to misuse; misapplication; negligence; alteration; ac cid ent or ope ratio n c ontr ary to our instructions, incompatibility with accessories not installed by KENT Purifiers or its ASP, or that have been repaired with component parts other than those manufactured by or obtained from KENT Purifiers or its ASP. Damage caused by freezing, flood, fire or Act of God is not covered by this Warranty. In all such cases regular charges will apply. This limited Warranty does not inc lude serv ice t o di agnose a claim ed malfunction in this unit.
12. KENT Purifiers reserves the right to alter or improve design and specifications at any time, without any contingent obligations to prospective buyers or owners of the products previously sold.
13. Any disagreements and obligations based upon the purchase of KENT Purifiers products and thereby imposed on KENT Purifiers or its ASP shall be governed by and construed according to the laws of INDIA and subject to the jurisdiction of Delhi Courts only.
14. KENT Purifiers or its ASP assumes no Warranty liability in connection with this water purifier other than that specified herein. This Warranty is in lieu of all other warran ties, expresse d o r implied, including warranties of fitness for a particular purpose. KENT Purifiers or its ASP does not authorize any person or represent tive to assume for them any other obligations on the sale of this water purifier.
15. Under no circumstances, the liabilty of KENT Purifiers or its ASP shall exceed the value of the product.
16. Under no c ircumst ances are the terms mentioned above negotiable and no employee of KENT Purifiers or its ASP has the authority to supersede them.
Page 6
Water Flow Diagram
KENT
TM
PRIME TC MINERAL RO
WATER PURIFIER
Product :
Serial No.
Customer's Name
Customer's Address
Customer's Ph.
TDS of Purified Water
Invoice No.
Invoice Date
Installation Date
Service Provider’s Name:
Service Provider's Address
Service Provider's Ph.
TDS of Raw Water
By signing on this installation report, the customer hereby agrees to the terms & conditions of warranty mentioned on the
back side of the warranty card.
Customer's Signature
Service Provider's Stamp
Electrical Circuit Diagram
4
100-300 V~, 50-60Hz
100-300 V~, 50-60Hz
Page 7
Insta llati on Proce dure :
Screw in the two 10x 50 self tapin g screw s (supplied with the package) on a same hor izontal level at a distance of 5.4 inch es (138 mm) from each other in the wall.
Caref ully h ang the p urifie r on t he wall w ith the he lp of wal l mounting slot holes pr esent on the back s ide of the purifi er as shown i n the figur e bel ow.
Fix the SS ball valve to the ¼ inch port of the 3-way connec tor as shown in the figu re.
1.
2.
3.
4. Connec t the 3-wa y connec tor to the raw wat er supply as sho wn in the
figur e. The threaded end of the 3-way conne ctor is fit ted in line wit h the raw wa ter supply . The othe r end c an be conn ected t o a tap or can be plugg ed off if not required.
TM
The Prime TC Mineral RO Water Purifier is a product of advanced technology, which ensures safe and clean drinking water. The purifier is easy and convenient to install.
Recom mended Site Prepar ations :
100-300 V~, 50-60Hz single phase AC connection not more than 3m away from the point of installation of purifier
Raw water supply with ½” nip ple not more than 3m awa y
Drain for rejecte d wat er not more than 3m away
Space as per dim ensions of the purif ier
Wall/ plane surfac e for mount ing two screws and holding the machine
The system and installa tion must comply with state and lo cal laws and regu latio ns
Speci fic Instruct ions :
TM
Prime T C Minera l RO Water Pur ifier is a wall mo untable puri fier. Make sur e that it is only
mount ed on a wall. Avoid installat ion on wooden and metallic stand s
For optimu m perfo rmance and minimum inlet pres sure required, ensu re that the raw water supp ly tank is at least 10 ft abo ve the level at which the puri fier is instal led
It is prefe rable t o in stall th e purifi er near a sin k so that inl et and reject water lines are ea sily avail able
KENT
KENT
n
n
n
n
n
n
n
n
n
Installation Instructions
6
Slot holes
5
UV Fail Alarm
To ensure delivery of 100% pure and healthy water, a micro-processor is installed in the purifier that performs the following functions: -
UV Stabi lizatio n Del ay: To ensure that th e UV lamp is pre- heated and is worki ng at its optimum lev el before i t starts disinf ecting wa ter, the co ntroller provi des a two seconds d elay to UV lamp when t he purifi er is switched on. During this period, only th e UV lamp i s sw itched on and other electrical device s of the puri fier are switch ed off.
Purifi cation Delay: T o ensure that the i dle water lyin g in the inte rnal pipes and in t he UV chamber is disinf ected before being pa ssed into the storage tan k, the system provide s 5 secon d del ay when the purifi er is switched on. During this time, the UV lamp kills all micro-orga nisms that may be in the water inside U V chamber. Afte r this delay, all ot her electrica l devices such as b ooster pump and so lenoid valve are switched on to star t nor mal purif ication process.
Audibl e Ala rm: The controlle r als o con trols the timing of UV Fai l Ala rm and the Filter Chan ge Alarm.
Computer Controlled Operation
n
n
n
n
The puri fier automaticall y shuts off when the
The pu rifier automatically restarts when
storage tank becomes full
water level drops below the maximum
The purifier does not star t when inle t water
The purifier does not allow any water rejection in
2
supply pressure is below 0.3 kg/cm
absence of electricity / when tank is full
Automatic Operation
KENT TMPrime TC Mineral RO Water Purifier has an in-built feature that sounds an audible alarm if the UV
lamp malfunctions. This feature is provided to ensure 100% purity. This UV Fail Alarm will sound like following:
Two short beeps after every two seconds.
In case such an alarm is audible, kindly switch off the purifier and call the service technician for help. The purifier will stop its purification process in such a circumstance.
2 Sec . 2 Sec . 2 Sec .2 Sec .
Filter Change Alarm
KENT Prime TC Mineral RO has an in-built feature that sounds an audible alarm to indicate replacement
time for filters. This alarm will be audible after 700 hrs of use since the last filter change (or since the time of installation). The Filter Change Alarm will sound like following:
4 short beeps after every two seconds; for 30 seconds. The alarm will repeat after every 2 hours of use.
In case such an alarm is audible, please call the service technician and request him to change the filters of the purifier. However, if the filters are not changed within the next 60 hours of operation, the purifier will stop functioning to ensure purity and hygiene. The following alarm will be audible after 60 Hrs. A continuous beep for an infinite time.
In case, such an alarm is audible, kindly switch off the purifier and call the service technician to replace the filters. In such a circumstance, the purifier will not function unless the filters are changed.
2 Hou rs
30 Se c. 30 Se c.
Page 8
Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw water and water consumption. They are not covered under the warranty. However, if a filter chokes within six months and a membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the filters and system inspection is available on call. The treatment capacity of RO membrane will reduce with time due to clogging of pores of membranes.
“This re verse osmosi s system conta ins a replacea ble comp onent cri tical to the eff iciency of Repla cement of the rev erse osmos is compone nt should be with on e of ident ical speci fications as defin ed by the ma nufacturer , t o e nsure the same efficienc y and contami nant redu ction perfo rmance .”
The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verify that the system is performing properly.
Repla cement of spare parts are as under: -
Maintenance
8
-20010 SP Inline Sediment Filter 8”
-20009 SP Inline Carbon Block Filter 8”
-20002 SP RO Membrane Welded 8” Housing
-20015 SP Post Carbon Filter (Blue)
-20003 SP Hollow Fibre Membrane (GPMRO)
7
n
n
n
n
n
n
Switch on the power supply so as to remove any dust particles present in
the pipes and storage tank
Wait till the storage tank fully fills up
Close the drain plug and switch on the power
Switch off the power supply
supply
Drain the storage tank by opening the drain plug present at the bottom of the storage tank
The purifie r is ready to use
Star ting Up the Purifier
5.
6.
7.
(I)
(ii)
Now connec t one end of the white pipe to the SS ball valve and other end to t he lower pushfit elbow fitting on the left han d side of the purifier label ed as WATER IN. (Note : Whi te pipe is for raw water suppl y)
Simil arly, connect o ne end of the blu e pipe to the upp er elb ow fittin g conne ctor labeled as REJECT WATER and leave the other end in the drain . (No te : Blue pipe is for reject water)
Befor e conne cting the power s upply, it is impo rtant that you perfor m the follo wing functio ns:
Open the SS ball valve (Handle parall el to the bal l val ve) t o sta rt th e flow of water into the purif ier.
Wait for 2 -3 m inutes to e nsure t hat the filt ers are soaked in wa ter.
TM
A unique feature in Prime TC Mineral RO screw of the valve anticlockwise; it will result in
Water Purifier is the TDS control valve, which is not more mineral content in treated water. To reduce
available in any other domestic water purifier till the TDS level, user can turn the screw valve
date. This feature allows the user to control the clockwise, it will result in less mineral content in
content of natural minerals (TDS) in purified treated water. We recommend the TDS of the
water . purifier to be kept at lowest but not below 50
mg/l.
To increase the TDS level the user can turn the
KENT
TDS Adjustment
Al th oug h the r eje ct ed wa ter h as hi gh of salts and minerals which accelerate plant
concentration of salts. This rejected water usually growth. Rejected water can also be used for
goes down the drain, but if required, can be used cleani ng purp oses, i .e. utensils cleaning ,
for gardening purposes. It has high concentration mopping, etc.
Recommended Uses of Rejected Water
or after every 12 month s. It is recomme nded to
To ensure that the purifier operates at its optimum level, a routine maintenance must be performed.
chang e the FRT when the fil ters are rep laced
The frequency of the maintenance will greatly
Repla ce the RO membran e on ce in 2 yea rs
dep end upon the raw wat er q uali ty a nd consumption of treated water
Repla ce the UV Lamp once in 2 Years
Stora ge tan k must be draine d once in 2 we eks.
If you ar e no t goin g to use the purif ier for a
To d o so, s witch o ff th e power supply, open
long time ( in case you are on a hol iday, tour or
the drain plug at the bottom of th e tank and
out o f home ), make su re that yo u disc onnect
allow t he water to dr ain. Then scr ew back the
the power sup ply, tu rn off the raw wate r
plug and switch on the power supply
suppl y and drain the storage tank
Repla ce sedimen t, activat ed carbon an d post carbo n when the filt er cha nge alarm is audible
n
n
n
n
n
Page 9
Technical Specifications
PRODUCT
* Treatment capacity tested for tap water having TDS level of 750 ppm at room temperature
9 10
Product Code
Applications
Purification Capacity
Body Material
Mounting
Dimensions(mm)
Inlet Water P ressure/Temp (Min)
Inlet Water P ressure/temp (Max)
Filter Cartridge
UV La mp Watta ge
Weight
Storage Capacity
Purification Production Rate
Maximum Duty Cycle
Membrane Type
Booster Pump Voltage
Power Consumption
Input Power S upply
11030
Suitable for Purification of Brackish / Tap Water
Upto 15 LPH*
ABS Food Grade Plastic
On the Wall
L 410 W 260 H 520
2
0.3Kg / cm or 4.267psi / 10°C
2
3Kg / cm or 42.67psi / 35°C
Sediment, Carbon Block Filter, UF and Post Carbon
11 W
8.340 kg.
9 L
15 L/hr.
75 L/day
Thin Film Composite RO
24 V DC
60 W
100-300 V ~, 50-60 Hz, 800 mA
TM
KENT PRIME TC Mineral RO Water Purifier