iNSTALLATiON AND SERVICE MUST BE PERFORMED BY
A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-- WHAT TO DO IF YOU SMELL GAS:
° Do not try to light any appliance.
° Do not touch any electrical switch; do not use any phone in your building.
° Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
° If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
For Standard
Installation:
Gas Cooktop Dimensions
GasCooktop Cutout
Dimensions 3"(7.6cm)
2"(5.1 cm) Dia.
Opening to route
power cable
F
G
Do not slide unit into cabinet cutout.
Protruding screws on the bottom of ur it
may damage the bottom front finish.
C
4"X 4" (10.2 cmx I0.2 cm)
i to route gas supply.
**Note: D & Eare critical to the proper
installation of the cooktop. D reflects the
finished dimension. Due to the variation in
countertop materials, it isrecommended to first
undercut this dimension, and then adjust it
Figure 1
upon installation of the cooktop.
* 30" (76.2 cm) rain. for
unprotected cabinet and
24" (61 cm) rain. for cabinet
with protected bottom surface.
71/4
(18.4 cm)
30 (76.2) 297/8(75.9) 25 (63.5) 73A(19.7) 29_5/16 (76) I 293/16(74.1)
All dimensions are stated in inches and (cm).
NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
22 (55.9) 1% (2.9) Max 7V2 (19.1)
318201473 (0708) Rev. C
English - pages 1-8
Espahol - p_iginas 9-16
Wiring Diagram page - 8
For Installation with the optional Stainless Steel Backsplash.
GasCooktop Dimensions
2" (5. I cm)
9"(22.9cm)
Optional
Stainless Steel
Backsplash
* 30" (76.2 cm) min. for
unprotected cabinet and
24" (61 cm) min. for cabinet
with protected bottom surface.
C
***Note: Applies only in case
of countertop backwall.
2"(5.1 cm) Dia.--
opening to route
power cable.
GasCooktop Cutout Dimensic%
Do not slide unit into cabinet cutout.
Protruding screws on the bottom of unit
may damage the bottom front finish.
Figure 2
4"X 4" (10.2 cm x 10.2 cm)
pening to route gas supply.
H
7Y4"(18.4 cm)
29V8
cm)
**Note: D & E are critical to the proper
installation of the cooktop. D reflectsthe
finished dimension. Due to the variation in
countertop materials, it isrecommended to first
undercut this dimension, and then adjust it
upon installation of the cooktop.
30 (76.2) 297/8(75.9) 25 (63.5) 73A(19.7) 29_s/_(76) 293/_6(74.1) 22(55.9) 1Y8(2.9) Max. 7Y2(19.1) 29_s/_6(76)
All dimensions are stated in inches and (cm).
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the
electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leavethese instructions with the consumer.
5. Note: For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for
future reference.
Depth Adjustment Filler Kit #903051-9100
This cooktop isdesigned to replace existing unit. If the
depth of your countertop opening isbigger than 7Y4" (18.4
cm) and lessthan 8Y2" (21.6 cm) you can order a free filler
kit #903051-9100 by calling SearsParts & Repair Center at
1-800-4-MY-HOME®.
Optional Item Available:
• A 9" (22.9cm) Stainless Steel Backsplash
Kit #903048-9100
This kit can be ordered for purchase through SearsParts
& Repair Center at 1-800-4-MY-HOME®.
IMPORTANT SAFETY
• Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
This cooktop must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70--latest edition in the United States, or in
Canada, with the Canadian Electrical Code, CSA
C22.1 Part 1.
• The burners can be lit manually during an
electrical power outage. To light a burner, hold a
lit match to the burner head, then slowly turn the
Surface Control knob to LITE. Use caution when
lighting burners manually.
• Do not store items of interest to children in
cabinets above the cooktop. Children could be
seriously burned climbing on the cooktop to reach
items.
• To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.
• Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.
• Never use your cooktop for warming or heating
the room. Prolonged use of the cooktop without
adequate ventilation can be hazardous.
• Do not store or use gasoline or other flammable
vapors and liquids near this or any other
appliance. Explosions or fires could result.
INSTRUCTIONS
Installation of this cooktop must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1/NFPA54--1atest edition in the
United States, or in Canada, with the Canadian Fuel Gas
Code, CAN/CGA B149 and CAN/CGA B149.2.
When installed in a manufactured (mobile) home
installation must conform with the Manufactured Home
Construction and Safety Standard, title 24 CFR,part
3280 [Formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD (part 280)] or,
when such standard is not applicable, the Standard for
Manufactured Home Installation, ANSI/NCSBCS A225. I
or with local codes where applicable.
This cooktop has been design certified by CSA
International. As with any appliance using gas and
generating heat, there are certain safety precautions you
should follow. You will find them in the Use and Care
Guide, read it carefully.
The electrical power to the cooktop
must be shut off while gas line connections are
being made. Failure to do so could result in serious
injury or death.
13"(33cm)max.depth ,
forcabinetinstalledabove
cooktop
30"(76.2cm)Min.
ClearanceBetweenthe
TopoftheCooking
PlatformandtheBottom
ofanUnprotectedWood
orMetalCabinet
24"(61cm)Min.
whenBottomofWoodjlf
orMetalCabinetis
ProtectedbyNotLess
ThanI/8" Flame
RetardantMillboard
Covered With Not Less
Than No. 28 MGS
Sheet Steel, 0.015"
(0.4 mm) Stainless
Steel, 0.024" (0.6 mm)
Aluminum or 0.020"
(0.5 mm) Copper
"_-. _min
"l_ between rear edge of
18" (45.7 cm) P
Min.
cutout and nearest
combustible surface
30" (76.2 cm) min.
clearance between
the top of the
cooking platform and
the bottom of an
unprotected wood or
metal cabinet.
_To eliminate the risk of
burns or fire from reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 7"
(17.8 cm) beyond the bottom of the
cabinets.
It isnot recommended to use
drawer underneath cooktop.
30" (76.2cm) 30" (76.2cm) 5" (12.7 cm) 5" (12.7 cm)
Figure 3 - CABINET DESIGN
Wall Outlet Location
(10_'cm)/-_
:
I 5"
, (12.7 cm)
Recommended , |
area for 120V I |
grounded outlet _, / ,,
on rear wall. _ (40.6 cm)
CENTRE
NOTE: If an LINE
outlet is not OFUNIT
available, have I
one installed by a ,
qualified I
technic_
Figure 4'- OFUNIT
Provide an Adequate Gas Supply
This cooktop is designed to operate on natural gas at 4"
(10.2 cm) of manifold pressure only.
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
the supply line.
For proper operation, the maximum inlet pressure to
the regulator must be no more than 14" (35.6 cm) of
water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least 1"(2.5 cm) (or 2.5 kPa) greater than the regulator
manifold pressure setting. The regulator isset for 4"
(10.2 cm) of manifold pressure, the inlet pressure must
be at least 5" (12.7 cm).
The gas supply line to the appliance should be 1/2" (1.3
cm) or 3/4" (1.9 cm) pipe.
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LPgas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANEGAS
CONVERSION".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and all
local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
16
.. _, CENTRE
LINE
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Important: Remove all packing material and
literature from cooktop before connecting gas and
electrical supply to cooktop.
Install Pressure Regulator
Install the pressure regulator with the arrow on the
regulator pointing up toward the unit in a position where
you can reach the access cap.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.
Manual GAS FLOW Pressure
Shutoff Flare _'_ Flare Regulator
Valve Union Union _,
Nipple Flexible Nippl
Off Connector
All connections must be wrench-tightened
Figure 5
Assemble the flexible connector from the gas supply pipe
to the pressure regulator in the following order:
I. manual shutoff valve
2. I/2" (1.3 cm) nipple
3. 1/2" (1.3 cm) flare union adapter
4. flexible connector
5. I/2" (1.3 cm) flare union adapter
6. 1/2" (1.3 cm) nipple
7. pressure regulator
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
connectors are used, be certain connectors are not
kinked.
The supply line should be equipped with an approved
shutoff valve. This valve should be located in the same
room as the cooktop and should be in a location that
allows ease of t_
opening and
closing. Do not %%
block access to
the shutoff valve.
The valve is for
turning on or
shutting off gas
to the appliance.
Shutoff Valve
Open position
Access
Cap