Kenmore Elite 79046822100, 79046823100, 79046824100, 79046829100, 79046999100 Installation Guide

...
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Do not pinch the power supply
cord between the range and the wall.
Do not seal the range to the
NOTE: 24" (61 cm) minimum clearance
between the cooktop and
the bottom of the cabinet when the bottom of wood
or metal cabinet is protected by not less than
1/4" (0.64 cm) flame retardant millboard covered
with not lessthan No. 28
MSG sheet metal, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance when the cabinet
is unprotected.
NOTE: Allow at least 19 ¼" (48.9 cm) clearance
for door depth when it is open.
Shave Raised Edge
To Clear 30" (76.2 cm) Wide Cooktop
Rim.
1 1/2"Max.
(3.8 cm Max.)
Locate Cabinet Doors 1 (2.5 cm) Min. From Cutout
Opening
* Note: 29" (73.7 cm)
Wide Opening For
Overlapping Cooktop and Built-In Look.
If Installing Models With Optional Side Panels, Cutout Area Including Countertop Must Be At
Least 30" (76.2 cm) Wide.
1 1/2"
30" Min.
(76.2 cm) Min.
(76.2 cm) Min.**
18" Min.
(45.7 cm) Min.
Min.
(61 cm) Min.
Grounded Junction Box or Wall Outlet Should Be Located 8" to
17" (20.3 - 43.2 cm) From Right Cabinet and 2" to 4" (5.1-10.2
cm) From Floor
r_ 22 718"_1
A
(58.1 cm)
ili! !i
(45.7 cm
Ol 1/8"
FRONT _ GRef'_
OF
CABINET
Door Open,..
(see note) .......... /
35 3/8"- 36 3/8"(90-92 cm) 30" (76.2 cm) 26 1/4"(66.7 cm) 29" (73.7 cm) 21 3/4" (55.2 cm) 36" (91.4 cm) standard
35%" (90cm)min.
G. Minimum cutout depth is increased to 24" (61 cm) with backguard. P/N318201603 (0201) Rev. B
English- pages 1-10
Espahol- p_tginas11-20
Important Notes to the Installer
1. Readall instructions contained in these installation instructions before installing range.
2. Remove all packing material from the oven and the drawer compartments before connecting the electrical supply to the range.
3. Observe all governing codes and ordinances.
4. Besure to leave these instructions with the consumer.
Before installing the range in an area covered with linoleum or any other synthetic floor covering, make sure the floor covering can
withstand heat at least 90°F above room temperature without shrinking, warping or
discoloring. Do not install the range over carpeting
unless you place an insulating pad or sheet of 1/4" thick plywood between the range and carpeting.
Important Note to the Consumer
Keep these instructions with your owner's guide for future reference.
IMPORTANT SAFETY INSTRUCTIONS
Be sure your range is installed and grounded
properly by a qualified installer or service
technician.
This range must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No. 70--latest edition.
The installation of appliances designed for
manufactured (mobile) home installation must conform with Manufactured Home Construction and Safety Standard, title 24CFR, part 3280 [Formerly the Federal Standard for Mobile Home Construction and Safety, title 24, Hun (part 280)] or when such standard is not applicable, the Standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and Setups), ANSI Z225.1/NFPA 501A-
latest edition, or with local codes.
Make sure the wall coverings around the range
can withstand the heat generated by the range.
IV!'W'-_It_II_[cl To reduce
All ranges can tip.
Injury to
personscould result.
Install anti-tip
device packed with
range.
the risk of tipping of the
range, the range must be
secured by properly
installed anti-tip bracket
(s)provided with the
range. To check if the bracket (s)is installed properly, grasp the top rear edge of the range
and carefully tilt it forward to make sure the
range isanchored.
Never leave children alone or
unattended in the area where an appliance is in use.
As children grow, teach them the proper, safe use of all appliances. Never leave the oven door open when the
range is unattended.
Stepping, leaning or sitting on the
door or drawer of this range can result in serious
injuries and can also cause damage to the range.
Do not store items of interest to children in the
cabinets above the range. Children could be seriously
burned climbing on the range to reach items.
To eliminate the need to reach over the surface
units, cabinet storage space above the units
should be avoided.
Do not use the oven as a storage space. This creates a potentially hazardous situation.
Never use your range for warming or heating the
room. Prolonged use of the range without adequate
ventilation can be dangerous.
Do not store or use gasoline or other flammable
vapors and liquids near this or any other appliance. Explosions or fires could result.
Reset all controls to the "off" position after using a programmable timing operation.
FOR MODELS WITH SELF-CLEANFEATURE:
Remove broiler pan, food and other utensils
before self-cleaning the oven. Wipe up excess
spillage. Follow the precleaning instructions in the Use and Care Guide.
Power Supply Cord Kit
The user is responsible for connecting the power supply cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or nonmetallic shielded copper cable), or by means of a power supply cord kit. Only a power supply cord kit rated
at 125/250 volts minimum, 40 amperes minimum and
marked for use with ranges shall be used. See chart
(next page) for cord kit connection opening size
information. Cord must have either 3 or 4 conductors.
Formobilehomes,newinstallations,recreational
vehicles,orareaswherelocalcodesdonotpermit groundingthroughneutral,a4conductorpowersupply cordkitratedat125/250voltsminimum,40amperes andmarkedfor usewithrangesshouldbeused(see
Figure4).
Terminalsonendofwiresmustbeeitherclosedloopor open-endspadelugswithupturnedends.Cordmust
havestrain-reliefclamp.
Seebelowfor3or4conductorwireconnection.
Range Connection Opening Size Chart
Refer to chart below for proper range connection opening size and power supply cord kit ampere rating information. See serial plate on range for kilowatt rating data.
See Serial Plate on Range for KW Rating
120/240 Volts 120/208 Volts
8.8-16.5 Kw 7.9-12.5 Kw
16.6-22.5 Kw 12.6-18.5 Kw
Minimum
Cord kit
Ampere
Rating
40 Amp
50 Amp
NOTE: Electric Slide-in Range isshipped from factory with 1-1/8" dia. hole asshown on figure 3. If a larger hole is required, punch out the knockout.
Diameter (inches) of Range
Connection Opening
Direct
Cord Kit Connection 1-3/8 in. 1-1/8 in.
1-3/8 in. 1-3/8 in.
Electrical Shock Hazard
Electrical ground is required on this appliance. Do not connect to the electrical supply until appliance is permanently grounded. Disconnect power to the circuit breaker or fuse box before making the electrical connection. This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
Three Conductor Wire Connection to Range
(The 3-conductor cord or cable must be replaced with a 4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations, mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 3).
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, the
Installation Instructions are not followed, or the
strain relief bracket is discarded.
Figure 1
Do not loosen the nuts which secure
the factory-installed range wiring to terminal block while connecting range. Electrical failure or loss of electrical connection may occur.
Electrical Connection to the Range
This appliance is manufactured with the neutral terminal connected to the frame.
, Remove the 3 screws at the lower end of the rear
wire cover, then bend the lower end of the rear wire cover (access cover) upward to expose range
terminal connection block (see Figure 2).
BEND REAR WIRE COVER HERE
FORACCESSTOTERMINALBLOCK
Figure 2
2. Remove the 3 loose nuts (after you remove the rubber band) on the terminal block using 3/8" nut
driver or socket.
3. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red wires connected to the right terminal, black wires
connected to the left terminal).
4. Replace the 3 nuts on the terminal block (see figure
3).
5. Lower the terminal cover and replace the 3 screws.
Silver colored Terminal
Block
Terminal
Wire
Terminal
Block
Black
wire
1-1/8" Dia.
supplied by the user must be installed at
this location
To 240 V
receptacle
Direct
Connection Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
Figure 3
Four Conductor Wire Connection to Range
(mobile homes)
1. Remove the 3 screws at the lower end of the rear wire cover, then raise the lower end of the rear wire
cover (access cover) upward to expose range terminal connection block (see figure 2).
2. Remove the 3 loose nuts (after you remove the rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the ground strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame where the ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red wires connected to the right terminal, black wires connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see figure
4).
7. Lower the terminal cover and replace the 3 screws.
Bla_
1-1/8" Dia. Direct
Connection Hole. Punch out knockout
for 1-3/8" Dia.
Cord Kit Hole
A strainrelief supplied by the user
must be installed at 240 V receptacle this location
NOTE: Be sure to remove the supplied /<l
grounding strap
Figure 4
Direct Electrical Connection to the Circuit Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored or nonmetallic sheathed copper cable (with grounding wire). Supply a U.L. listed strain-relief at each end of the cable. At the appliance end, the cable goes through the
Direct Connection Hole (see Figure 4) on the Cord
Mounting Plate. Wire sizes (copper wire only) and connections must conform to the rating of the appliance.
Where local codes permit connecting the appliance- grounding conductor to the neutral (white) wire (see Figure 5):
(The 3-conductor cord or cable must be replaced with a 4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas where local codes do not permit neutral grounding)
.
Disconnect the power supply.
2.
In the circuit breaker, fuse box or junction box: connect appliance and residence cable wires as shown in figure 5.
4
White Wire
(Neutral)
Red
Cable from
Residence
Wires-
Cabinet Construction
To eliminate the risk of burns or fire by
reaching over heated surface units, do not have cabinet storage space above the range. If there is cabinet storage space above range, reduce risk by installing a
range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinet.
Box
White Wire
(Neutral)
Green U.L.-listed (or Bare Copper) Conduit
Wire Cable from Connector
Range (or CSA listed)
Figure 5
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
Where local codes DO NOT permit connecting the
appliance-grounding conductor to the neutral (white) wire, or if connecting to 4-wire electrical system (see Figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white appliance cable wires.
3. In the circuit breaker, fuse box or junction box: connect appliance and residence cable wires as shown in figure 6.
Cable from Green Residence (or Bare Copper) Box
Junction
Cou ntertop Prepa ration
The cooktop sides of the range fit over the cutout edge of your countertop.
If you have a square finish (flat) countertop, no countertop preparation is required.
Formed front-edged countertops must have molded edge shaved flat 1/4" (0.64 cm) from each front corner
of opening.
Tile countertops may need trim cut back 1/4" (0.64 cm) from each front corner and/or rounded edge
flattened.
width ,,f
(.64 cm) back at front corners of
I countertop opening.
30.00
_(76.2 cm)
Formed or tiled countertop
trimmed 1/4 (.064cm)
If the countertop opening width is greater than
the minimum cutout width, adjust the 1/4" (0.64
cm) dimension.
Green (or Bare Copper)
Wire
Cable from Conduit
Appliance Connector
Figure 6 - 4-Wire Electrical System
(Example: Junction Box)
Countertop must be level. Place a level on the countertop, first side to side, then front to back. If the countertop is not level, the range will not be level. The oven must be level for satisfactory baking results. Cooktop sides of range fit over edges of countertop opening.
(or CSA listed)
Range Installation
When unpacking the range, do not
discard the 2 front shipping bolts, but screw them into the holes at the front corners of the range; they will function asthe front leveling legs. Discard the 2 other
bolts; they are not needed, and are installed on the
range for shipping purposes only. This appliance is equipped with a new rear leveling system that allows you to level the range after installation in cutout opening.
Installation Without Side Panel(s)
1. The range cooktop overlaps the countertop at the sides and the range rests on the floor. The cooktop is
30" (76.2 cm) wide.
2. Install base cabinets 29" (73.7 cm) apart. Make sure they are plumb and level before attaching cooktop. Shave raised countertop edge to clear 30" wide
range top rim.
3. Install cabinet doors 31 " (78.7 cm) min. apart so it will not interfere with range door opening.
4. Cutout countertop exactly as shown on page 1.
5. A backguard kit can be ordered through Sears Service Center.
For models equipped with Leveling Device:
6. When you unpack the range, the leveling devices
at rear are at the highest position they can be. Make sure the front leveling legs are also at their highest position.
7. _ Install the anti-tip bracket at this
point before placing the range at its final position. Follow the installation instructions on
page 8 or on the anti-tip bracket template supplied with the range.
8. Slide the range into the cutout opening.
9. Level the range (figure 7). The floor where the
range is to be installed must be level. Follow the instructions under "Leveling the Range-
Models Equipped with Leveling Device"
For models equipped with Leveling Legs:
6. Adjust leveling legs so that the underside of the
cooktop is sitting on the countertop.
7. Level the range. The floor where the range is
to be installed must be level. Follow the instructions under "Leveling the Range-Models
Equipped with Leveling Legs"
5. Follow steps 6 to 9 "Installation Without Side Panels" above.
Installation With Backguard
The cutout depth of 21 5/8" (55 cm) needs to be
increased to 24" (61 cm) when installing a backguard.
Leveling the Range - Models Equipped with Leveling Device
Level the range after installation in the cutout
opening.
1. Open the range drawer and remove the two metallic caps covering the 2 leveling screws. These leveling screws control the height of the rear leg.
2. Adjust the appliance legs as follows until the underside of the cooktop surface is sitting level on
the countertop (Figure 7).
a.To adjust the front legs, use a wrench on the leg
base and turn clockwise to lower or counterclockwise to raise.
b.To adjust the rear legs, use a ratchet or a
nutdriver and turn the leveling screws counterclockwise to lower or clockwise to raise.
Font
Leveling
Leg
LOWER
RAISE
Installation With Side Panel(s)
1. Install base cabinets 30 V8" (76.5 cm) mm. apart. Make sure they are plumb and level.
2. Install cabinet doors 31 " (78.7 cm) min. apart so as not to interfere with range door opening.
3. A backguard kit can be ordered through a Sears
Service Center.
4. An end panel kit can be ordered through a Sears
Service Center.
Figure 7
3. Check if the range is level by installing an oven rack in the center of the oven and placing a level on the rack (Figure 8).
4. Take 2 readings with the level placed diagonally in
one direction and then the other. Level the range, if
necessary, by adjusting the leveling legs.