Kenmore Elite 79045219410, 79045219411, 79045212410, 79045213410, 79045119410 Installation Guide

...
iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A
QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
c .s
LISTED
30" Min. *
(76.2 cm)
Cooktop Cutout Dimensions
IMPORTANT INSTALLATION-IN FORMATION
o All electric cooktops run off a single phase, three-wire
or four-wire cable, 240/208 volt, 60 hertz, AC only electrical supply with ground.
Pleasenote minimum distances between cooktop and adjacent and overhead cabinetry is30" (76.2 cm).
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
C
N .....
Figure I - 30" Model shown only
PRODUCTD,IMENSIONS
MODEL A:WIDTH BIDEPTH C: HEIGHT D BOXWiDTH EBOX DEPTH
30" CeramicModel 30% (77.8) 21Vs(54.4) 43/4(12.1) 281/s(71.4) 19 (48.3) 36" CeramicModel 36% (93) 211/2(54.6) 4% (12.1) 331/2(85.1) 18% (47.6)
CUT0UTDIMENSIONS
EWlDTH G: HIHEIGHTBEI.OW
30" CeramicModel 281/2(72.4) 30 (76.2) 19% (49.8) 20I/2(52.1) 61/2(16.5) 36" CeramicModel 337/8(86.1) 36 (91.4) 191/8(48.6) 201/2(52.1) 61/2(16.5)
All dimensions are in inches (cm). **Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for
installation of the junction box on the wall at the back of the cooktop.
Printedin China
P/N 318205428 (1311) Rev. B
English - pages 1-6
Espahol- pages 7-12
Fran_ais - pages 13-18
Overhead Cabinet Should Not Exceeda
Maximum Depth of 13" (33cm)
L
30" (76.2cm) Min. Clearance Between
the Top of the Cooking Platform
and the Bottom of an Unprotected Wood
or Metal Cabinet
24" (61cm) Min. when Bottom of Wood
or Metal Cabinet is Protected by Not
LessThan 1/8" Flame
Retardant Millboard Covered With Not Less Than No. 28 MGS Sheet
Steel, 0.015" (0.4mm) Stainless Steel, 0.024"
(0.6mm) Aluminum or
0.020" (0.5mm) Copper
18"
(45.7cm)
G
K Min. Recommended
Distance Between _
RearEdge of
Cutout and Nearest Combustible 10"
Surface Above (25.4cm) Countertop
F
12"
(30.5cm)
J Min. From
Edge of
Cooktop to Nearest
Combustible Wall (Either
Side of Unit).
Approximate Location
2 1/2" (6.4cm) Min. om
Edge of Cutout to Front Edge
of Countertop
Letterson this figure refer to chart on front page except for J, K & L.
Toeliminate the risk of burns or fire resulting from reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
Figure 2 - COUNTERTOP CUTOUT OPENING
of Junction Box
30"CeramicGlass 36"CeramicGlass
2
7 ½"(19.1cm) 7 ½"(19.1cm)
For a drawer installation below the cooktop, allow
8" (20.4cm) of clearance underneath the countertop.
The drawer must not interfere with the electrical installation
of the cooktop or contain flammable materials.
l i i! ! ! ! ii iiii ii ii ii ii iiiiiiii ii iiiiiiiiiii ii ii ii ii iiii ii ii ii ii iiii ii i iiiiii!i ! i ii!i!! ! ! !!! !i i!i!!! !i !!!!i!!ili!i!ii!!i!!i ii !iiii i!il