Kenmore Elite 79043993700 Installation Guide

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Cooktop Dimensions
All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only electrical supply with ground.
30" Min. *
(76.2 cm)
C
Minimum distance between cooktop and overhead cabinetry is30" (76.2 cm).
Cooktop Cutout Dimensions
4" X 8" (10.2 cm x 20.3 cm)
! to route armored
cable if a panel is present
IMPORTANT INFORMATION FORPROPER
INFRAREDTOUCH CONTROL FUNCTION
Inorder to prevent faulty adjustment of the
controller sensorsdue to foreign light, the
intensity of illumination at the first power on
should not exceed 1000 lux. Direct irradiation of the touch panel with light from aspotlight
should be avoided during the power process.
If the illumination exceeds 1000 lux, the
control doesn't display the version and stop the automatic adjustment. In this caseturn
* 30" (76.2 cm) min. for unprotected cabinet
Figure 1
down the controls switch of the light till the
illumination is lower than 1000 lux.
24" (61 cm) min. for protected surface
E DEPTHBELOW
C00KTOP*
s(12.7)
All dimensions are in inches (cm). * Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for installation of the junction box on the
wall at the back of the cooktop.
Printed in the United States P/N 318201446 (0706) Rev. A
English - pages 1-6
Espaf_ol- pages 7-12
OverheadCabinetShouldNotExceeda MaximumDepthof13"(33cm)
30"(76.2cm)Min.._111__
ClearanceBetweenthe-- i&,, I I I
Top of the Cooking I [ _,_ .......... _,,,_ k I
Platform and the _ D_t_B_ween _1 S
Bottom of an \ .... --
Unprotected Wood _ Kear _age OT or Metal Cabinet
24" (61 cm) Min. when Bottom of Wood or
Metal Cabinet is Protected by Not Less
Than 1/8" Flame
Retardant Millboard Covered With Not Less
Than No. 28 MGS Sheet
Steel, 0.015" (0.4 ram) Stainless Steel, 0.024"
(0.6 ram) Aluminum or
0.020" (0.5 ram) Copper
2 1/2" (6.4 cm) Min. From Edge
Cutout to Front Edge of
Countertop
18" D
(45.7 cm)
Combustible Surfac_
"_ Cutout and Nearest
Above Countertop
Approximate Location
of Junction Box
10"
25.4 cm)
25" Min.
63.5 cm Min.)
H Min. From Edge of Cooktop to Nearest
Combustible Wall
(Either Side of Unit).
Drawers cannot be used with this cooktop since burner
box extends G below surface of countertop.
FordimensionsA, D, E& F, seeTable on page 1.
_To eliminate the risk of burns or fire by reaching over heated surfaces,cabinet storage space located abovethe cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the
bottom of the cabinets.
Figure 2 - COUNTERTOP CUTOUT OPENING
¸MODEL 6
30" Ceramic-Gass 4" (10.2 cm)
J
Important Notes to the Installer
1. Readall instructions contained inthese installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codesand ordinances.
4. Be sure to leave these instructions with the consumer.
Important Note to the Consumer Keep these instructions with your Useand Care Guide for
future reference.
Electrical Requirements
Observe all governing codes and local ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (time- delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of the appliance specified on the
nameplate.
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70- latest edition, and local codes and ordinances.
IMPORTANT SAFETY INSTRUCTIONS
Be sure your cooktop is installed and grounded properly by a qualified installer or service
technician.
These cooktops must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.
70--latest edition in the United States, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, in Canada.
_The electrical power to the cooktop must be shut off while line connections are being made. Failure to do so could result in serious injury
or death.
Provide Electrical Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. NOTE: DO NOT connect the wire to the circuit panel at this time. Wait until all wires have been
connected in the junction box.
An extension cord must not be used
with this appliance. Such use may result in a fire, electrical shock, or other personal injury.
2. The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible armored cable extending from this appliance should
be connected directly to the grounded junction box.
The junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
the cable between the box and the appliance, so it can be moved if servicing is ever necessary.
3. A suitable strain relief must be provided to attach the flexible armored cable to the junction box.
Unpacking Instructions
Figure 3 (Under Cooktop)
1. If connecting to a 3-wire supply cable:
Connect the green (or bare copper) wire from the appliance cable and the supply cable (green or bare)
wire to the ground screw inside the junction box (see
Figure 4). Connect the remaining wires inside the
junction box from the power supply cable to the
matching colors of the appliance cable wires.
Cable from Power Supply
Model and Serial Plate
Ground Wire
.
Leave corner supports on cooktop until completion
of Electrical Connection.
2.
Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily. It is important that the ceramic-glass smoothtop be pretreated before use see Cooktop Cleaning and Maintenance section in the Use and
Care Guide.
Electrical Connection
Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
follows. Electrical ground is required on this appliance.
This appliance is equipped with a copper conductor flexible cable. If connection is made to aluminum house
wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and
ordinances.
Red
Wires
Black
Wires
Box
Ground Wire (Bareor
Green Wire)
U.L-Listed Conduit Connector
Cable from appliance
Figure 4
3-WIRE GROUNDED JUNCTION BOX
Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
This appliance is manufactured with a frame connected green (or bare copper) ground wire.