= All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
unprotected cabinet and 24" (61 cm) min. for cabinet with protected
bottom surface,
** DO NOT obstruct these
areas.
Cooktop Dimensions
Cooktop Cutout Dimensions
DO NOT apply any sealant along the perimeter. The cooktop must breath freely,
D
4" X 8" (10.2 cm x 20.3 cm)
H
J- L
. _ oo_:: :z - F \
opening to route armored cable
_::::_:.:::::::::::if a panel is present
r
Figure 1
43/8(11.1) 287/8(73.3) 20(50.8) 29#8(75.2)293A(75.6) 203/8(51.8) 20Y2(52.1) 4Y2(11.4) 4V8(11.1) 351A(89.5) 20(50.8) 357/8(91.1) 36(91.4) 203/8(51.8) 20Y2(52.1) 4Y2(11.4)
All dimensions are stated in inches and (cm). P/N 318205407 (0807) Rev. A Allow 2" (5 cm) space below the armored cable opening to clear the electric cable and English - pages 1-6 allow space for installation of the junction box on the wall at the back of the cooktop. Espafiol- pages 7-12
Printed in United States
OverheadCabinetShouldNotExceeda
MaximumDepthof13"(33cm)
g0" (76.2 cm) Min. CI Between the Top of the
Cooking Platform and the Bottom of an Unprotected
Wood or Metal Cabinet _._
1
24" (61 cm) Min. when Bottom of Wood or Metal
Cabinet is Protected by Not Less Than 1/8" (0.g cm)
Flame Retardant Millboard Covered With Not Less Than
No. 28 MGS Sheet Steel,
0.015" (0.4 ram) Stainless Steel, 0.024" (0.6 ram) Aluminum or 0.020" (0.5 ram) Copper.
18"
(45.7 cm)
AMin. ......._ I
Edge of Cutout and Nearest Combustible 10"
Surface Above 25.4 cm) Countertop
G
J Min. From Edge of
_,Cooktop to Nearest
Combustible Wall (Either Side of Unit).
21/2"(6.4 cm) Min. From Edge of Cutout to Front
* Letters on this figure refer to chart
Edge of Countertop
on front page except for J and K.
_To eliminate the risk of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet
storage is provided, risk can be reduced by
installing a range hood that projects
horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
Figure 2 - COUNTERTOP CUTOUT OPENING
Appr Location
of Junction Box
30"
36"
It is not recommended to use drawer underneath cooktop.
Empty space is needed for installation purpose.
2
important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the
electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the
consumer.
5. Only certain cooktop models may be installed over
certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number and product code.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for future reference.
_An extension cord must not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury.
3. The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible armored cable extending from this
appliance should be connected directly to the grounded junction box. The junction box should be located as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.
4. A suitable strain relief must be provided to attach the flexible armored cable to the junction box.
I
PORTANT SAFETY
I
o
Be sure your cooktop is installed and grounded
properly by a qualified installer or service technician.
This cooktop must be electrically grounded in accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No. 70--latest edition in the United States.
_The electrical power to the cooktop must be shut off while line connections are being
made. Failure to do so could result in serious injury or death.
UCTION
Provide Electrical Connection
Install the junction box under the cabinet and run 120/ 240 or 120/208 Volt, AC wire from the main circuit
panel. NOTE: DO NOT connect the wire to the circuit panel at this time.
Electrical Requirements
Observe all governing codes and local ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/ 208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (time-delay fuse or circuit breaker is recommended). DO NOT fuse neutral.
2. A circuit breaker or fuse rated at 40 Amp is recommended for the 30" model and a circuit
breaker or fuse at 50 Amp is recommended for the 36" model.
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70- latest edition and local codes and ordinances.
Unpacking Instructions
1. Unpack and visually inspect the cooktop.
2. Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily. It is important that the ceramic-glass cooktop be pretreated before use. See Cooktop Cleaning and Maintenance section in the Use
and Care Guide.
Electrical Connection
Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the junction box. Then make the electrical connection as
follows. Electrical ground is required on this appliance.
This appliance is equipped with a
copper conductor flexible cable. If connection is made to aluminum house wiring, use only special
connectors which are approved for joining copper and aluminum wires in accordance with the
National Electrical Code and local codes and ordinances. Improper connection of aluminum
house wiring to copper leads can result in a short circuit or fire. Follow the connector manufacturer
recommended procedure closely.
This appliance is manufactured with a supply wire and a frame connected green or bare copper grounding
wire.
DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.
3
Where local codes permit connecting the appliance-grounding conductor to the neutral (white) wire (see figure 3):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box, connect appliance and power supply cable wires as
shown in figure 3.
You may not ground the cooktop
through the neutral (white) wire if cooktop is used
in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local
codes do not permit grounding to the neutral
Cable from Power Supply
White Wire _---2, j_
(Neutral)_
Red
Black
if cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding to the neutral (white) wire (see figure 4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box, connect appliance and power supply cable wires as shown in figure 4.
Cable from Power Supply
Ground Wi -White Wire
re._ _)
Red ........ Black
Wires : _ _ _iWire s
L
Junction
S Box
ires
_Junction Box U.h-Listed
Green Wire (Ground)
Cable from
appliance
Figure 3 =3=WIRE GROUNDED JUNCTION BOX
(white) wire. When grounding to the neutral (white) wire is prohibited, you must use a 4-wire power supply cable. See Figure 4. Failure to heed this warning may result in electrocution or other
serious personal injury,
Conduit Connector
Green Wire (Ground) _U.h-kisted Conduit
: Connector
Cable from appliance
Figure 4 =4-WIRE GROUNDED JUNCTION BOX
If connecting to a 4-wire power supply
cable electrical system, the appliance frame connected ground wire MUST NOT be connected to the neutral wire of the 4-wire electrical system.
NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-listed for
connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor wire is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.
Model and Serial Number Location
The serial plate is located under the cooktop. When ordering parts for or making inquires about your
cooktop, always be sure to include the model and serial numbers and a lot number or letter from the
serial plate on your cooktop.
Serial plate is located under the burner box
of cooktop.
4
Loading...
+ 8 hidden pages