iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
if the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, persona[ iniury or death.
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
-- WHAT TO DO mFYOU SMELL GAS:
® Do not try to light any appliance.
* Do not touch any electrical switch; do not use any phone in your building.
* mmmediateIy caI[ your gas supplier from a neighbor's phone.
Follow the gas suppIier's instructions.
* mfyou cannot reach your gas supplier, caI[ the fire department.
-- mnstaiiation and service must be performed by a qualified installer, service agency or
the gas supplier,
Gas Cooktop
Dimensions
21/2"
Gas Cooktop (6,4 cm) Q
Cutout Dimensions , u
Figure 1
30"GasCooktop 30 (76.2) 21sA552) 4_/4(10.8) 27(68.6) I9 (48.3)
36"GasCooktop 36 (91.4) 2134(55.2) 4_/4(10.8) 33_/4(84,5) 19(48.3)
30" GasCooktop 27_/4(69.2) 28_/2(72.4) 19Vs(48,6)
36" GasCooktop 34_A(87) 19Vs(48.6)
A[[ dimensions are stated in inches and (cm).
Dimension F includes a 5" (12,7 cm) space underneath the cooktop for connection to gas supply line.
NOTE: Wiring diagrams for this cooktop are enclosed in this booklet
Printed in United States
318201465 (0510) Rew A
Espafiol - pa'ginas 10=18
Wiring Diagram 19=20
English - pages 1@
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the cooktop.
2. Remove all packing material before connecting the
electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leavethese instructions with tile consumer.
5. Note; For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer
Keep these instructions with your Useand Care Guide for
future reference.
IMPORTANT SAFETY
NS
Installation of this cooktop must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1/NFPA 54 in the United States, or
in Canada, with the Canadian Fuel Gas Code, CAN/CGA
B149 and CAN/CGA B149.2.
• When installed in a manufactured (mobile) home
installation must conform with the Manufactured Home
Construction and Safety Standard, title 24 CFR,part
3280 [Formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD (part 280)] or,
when such standard is not applicable, the Standard for
Manufactured Home Installation, ANSI/NCSBCS A225.1
or with local codes where applicable.
This cooktop has been design certified by CSA
International. As with any appliance using gas and
generating heat, there are certain safety precautions you
should follow. You will find them in the Useand Care
Guide, read it carefully.
• Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
• This cooktop must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70--latest edition in the United States, or in
Canada, with the Canadian EJectricat Code, CSA
C22.1 Part 1.
• The burners can be tit manually during an
electrical power outage. To light a burner, hold a
tit match to the burner head, then slowly turn the
Surface Control knob to UTE. Use caution when
lighting burners manually.
• Do not store items of interest to children in
cabinets above the cooktop° Children could be
seriously burned climbing on the cooktop to reach
items.
• To eliminate the need to reach over the surface
burners, cabinet storage space above the burners
should be avoided.
• Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.
• Never use your cooktop for warming or heating
the room. Prolonged use of the cooktop without
adequate ventilation (.an be hazardous.
• Do not store or use gasoline or other flammable
vapors and liquids near this or any other
appliance. Explosions or fires could result.
The electrical power to the cooktop
must be shut off whiJe gas Jine connections are
being made. Faiture to do so couJd resutt in serious
injury or death.
13" (33 cm)
Max, Depth
For Cabinet
Installed Above
Cooktop.
B
18" Min.
(45.7 cm)
A
lY2" (3.8 cm)Minimum Distance
Between RearEdge of Cutout
and Nearest Combustible Surface
Above Countertop.
Clearance
30" (76.2 cm)
Min. Clearance
Between the
Top of the
Cooking
Platform and
Unprotected
Wood or Metal
Cabinet
_To eliminate the risk of
burns or fire from reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. If
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5"
(I 2.7 cm) beyond the bottom of the
cabinets.
Drawers Cannot BeUsed with This
Cooktop Since Burner Box Extends
3Vs2" (8.02 cm) Below Surface of
Countertop.
Figure 2 - CABINET DESIGN
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
14_---- 18" (45.7 cm) Max.-----_
4" (10.2 cm)
Manifold Pi
61/2 ''
5" ,(16.5 cm)
Flare (12.7 cm) Min.
Union
÷
€
Wall Oven
Flexible Connector
Cabinet sides or
filler panel
Cabinet
120V/60Hz
Grounded
FlareUnion
/A
/A
Outlet
Pressure
Regulator
Manual Shutoff Valve
(To be accessible for
shut-off valve opera-
tion)
Right Side of
Cabinet
Typical Under Counter Installation of an Electric Built-in
Oven with a Cooktop Mounted Above
Side filler panels are necessary to
isolate the unit from adjoining
cabinets. Panel height should allow
for installation of approved cooktop
models. See "Typical Gas Cooktop
Installation Over an ElectricBuiltqn
Oven Installed Under the Counter"
on previous page.
32" Min.**
(81.3 cm)
36"
(91.4 cm)
All mounting hardware
must be used to secure
the builtqn oven to tile
cabinets. Refer to the
builtqn oven installa-
tion instructions.
208/240 Volt grounded junction
box for built-in
Junction box must
be located approx.
3" to the left of
the builtqn oven
cutout,
This cooktop may
be installed over
certain builtqn elee
tric oven models.
* If no cooktop is installed directly
over the oven unit, S" (12.7 cm)
maximum is allowed.
** 32" (81.3 cm) min. from top of
cabinet to top of runners must be
maintained.
Use 3/4" (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Must be capable of supporting 150 Ibs.
Cut an opening in wood base minimum 9"
(22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from
left side filler panel, to route armoured
(.ableto junction box.
4 1/2" (11.4 cm)
Max.*
CUTOUT DIMENSIONS (inches)
OVEN SIZE E F G
Min Max, Min Max,
30" 27¼" 28s/_" 281/2" 29" 23Y2"
(76,2cm) (69,2cm) - (727cm) (72,4cm) - (737cm) (59,7cm)
27" 27¼" 28s/_" 24V8" 25¼" 23Y2"
(68,6crn) (69,2crn) - (727cm) (63,1cm) (641cm) (59,7cm)
Wail Outlet Location
_12" 4
To clamp down, insert an angle bracket into the slot on
each side of the unit as shown.Run thumb screw up
through tile bracket, up against the bottom of the
counter. Tighten until the unit draws down and issecure.
Provide an Adequate Gas Supply
This (ooktop isdesigned to operate on natural gas at 4"
of manifold pressure only.
10"
A pressure regulator is connected in series with the
manifold on the cooktop and must remain in series with
tile supply line.
Recommended area for
12OV grounded outlet
on rear wall.
22"
: NOTE: If an outlet
is not available, [
have one installed by
_ a qualified technician.
½
OF UNIT
Figure 3
Cooktop Installation
1. Visually inspect the cooktop for damage.
2. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should
be removable for service when needed.
Clamp Down Information
Once the cooktop is installed in the counter opening, you
must (.lamp the unit down as shown.
Counte_op
For proper operation, the maximum inlet pressure to
the regulator must be no more than 14" of water column
(W.C.) pressure.
For checking the regulator, the inlet pressure must be at
least I" (or 2.5 kPa) greater than the regulator manifold
pressure setting. The regulator is set for 4" of manifold
pressure, the inlet pressure must be at least 5".
Tile gas supply line to tile range should be 1/2" or 3/4"
pipe.
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LPgas is supplied with your
cooktop. The kit is marked "FOR LP/PROPANEGAS
CONVERSION".
The conversion must be performed by a qualified service
technician in accordance with the kit instructions and all
local codes and requirements. Failure to follow
instructions could result in serious injury or property
damage. The qualified agency performing this work
assumes responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Figure 4
Thumb
Screw