Kenmore Elite 25376062312, 25376062410, 25376062411 Installation Guide

READ BEFORE INSTALLING UNIT
For Low Profile Window Air Conditioner
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time. Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp
metal fins of front and rear coils. Make sure air conditioner does not fall during installation.
SAVE CARTON and these INSTALLATION INSTRUCTIONS for future reference. The carton is the best way to store unit during winter, or when not in use.
o DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED IN THESE INSTRUCTIONS.
Tools Required
® SCREWDRIVER (Standard and Phillips and Flathead) o RULER
KNIFE HAMMER
o PENCIL LEVEL
Hardware ( in plastic bag)
SUPPORT BRACKET
LONG LEVELING BOLT 1
SHORT LEVELING BOLT 1
1/2" SCREW
Qty.
Hardware ( in plastic bag)
SASH LOCK
WEATHER SEALS
(6"X3/4"X 1/12")
WINDOW SASH SEAL
FOAM STRIP
Qty.
5
2020211A2592
How to install the unit
1. To prevent vibration and noise, make sure the unit is installed
securely and firmly.
2. Install the unit a little slanted so the back is slightly lower than the
front (about 1/4"). This will force condensed water to flow to the
outside. CAUTION: All side louvers of the cabinet must remain exposed to
the outside of the structure.
7
[
Install
ut 1/4"
Left + Right Filler Panel Assembly Place unit on floor, a bench or a table. There is a Left and Right side Filler Panels - be sure to use the proper
panel for each side. When installed, the flange for securing the panel in place to the window sill will be facing
into the room. A. Hold the side panel in one hand and gently pull back the center to free the open end. See FIG. 1.
B. Slide the free end "1" section of the panel into the cabinet as shown in FIG. 2. Slide the panel down. Be sure to
leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet, see FIG.3.
D. Slide the panel all the way in and repeat on the other side.
FIG.1 __--_'1"section FIG.2
Your air conditioner is designed to install in standard double hung windows with opening widths of 26.5 to 41.5 inches (673 mm to 1054 mm) (FIG. 4).
Lower sash must open sufficiently to allow a clear vertical opening of 12.4 inches (315 mm ). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building
or garage.
OFf ;ET
vZt.,°
Wooden Windows
CuttheFOAMSTRIPtofittheundersideofthewindowsash.Openthewindow,peeloffthebackandattach
theFOAMSTRIPasshowninFIG.5
Markcenterlinewithpencilonthecenteroftheinnersill,asshowninFIG.6
screw
inner
winnow.
sill
FiG. 5
FOAM STRIP
CENTER LINE INNER SILL
Install support bracket on window sill. See FIG.7. Install leveling bolt up through bottom side of support bracket.
You can choose a short bolt or a long one according to window type. Also, you should select the position of
hole on bracket. Position bracket on sill of center line of window (See FIG.7). Fasten bracket loosely to sill
with screws provided. Adjust leveling bolt so that the air conditioner will be installed with a very slight tilt
(about 1/4") downward toward the outside for proper drainage. (See FIG.8). Tighten bracket screws.
FIG. 6
'nne ,s'"si[ew a"uil'"
close-up view
adjustmentslot
bracket
INDO0 OR '
Fail to securely install support bracket may result in unit falling from window if window sash is raised after unit is installed. This could result in personal injury.
Install the air conditioner in the window
. With the aid of an assistant, carefully lift the air
conditioner and slide it into the open window. Make sure that support bracket is inserted in the pocket
under base fan, and that filler panels guide is stopped by stopper on the support bracket as shown in FIG.9.
NOTE: When unit is properly centered and pushed outward to correct bracket location, you will feel unit sit securely in place on the support bracket. Hold unit firmly during this procedure. After proper installation, make
sure the air conditioner is tilted 2-4 ° downward to the outside, condensate should not drain from the overflow drain hole
during normal use,correct the slope otherwise.
Lower top window sash all the way down so that sash sits firmly in top channel of unit and expandable
curtain frames. CAUTION: While performing the steps above, hold unit firmly until window sash is lowered to top channel behind filler panels. Personal injury or property damage may result
if unit falls from window.
window sash ---__
top channel_ J
section _
,ndoor
' Fstopper support
innersill---4 ___-- DracKe_
"---_ _---_k - leveling bolt
L_] _-.--outer sill
INDOOR I I_l OUTDOOR
FIG. 9
outdoor section
support
bracket pocket
SECURE THE CURTAIN FRAMES: Expand the filler panels and secure them using 4 screws
as shown in FIG.10. When filler panels opens or closes,
you may feel a slight resistance. This is normal. WINDOW SASH SEALAND WINDOW LOCK:
Cut the window sash seal to the window width. Stuff the window sash seal between the glass and the
window to prevent air and insect from getting into the room, as shown in FIG.10.
Trim the weather seal (6"X3/4"X1/12") to a proper length, peel off the protective backing and plug any gaps if needed as shown FIG.10.
Install the sash lock bracket to prevent window from
being raised which may result in unit falling.as shown °... in FIG.10. .."
NOT151 : It is difficult to lock the windows with the sash lock for some windows, so you can use lock by window itself.
NOTE#-: If window sash has a metal surface. Use sheet metal screws instead of the provided wood screws. Obtain sheet metal screws at local hardware store.
Sash lock and filler panels screws must be installed as instructed to avoid the possibility of unit falling from window and causing personal injury or property damage.
IF AIR CONDITIONER IS BLOCKED BY STORM WINDOW FRAME:
If storm window presents interference, fasten a 2" (51 mm) wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that unit can be installed
without interference from the storm window frame, See
FIG.11. Top of wood strip should be approximately 7/8°' (22mm) higher than the storm window frame to help condensation to drain properly to the outside.
Install a second wood strip (approximately 6" (152mm)long by 1-1/2" (38mm) wide and same thickness as the first strip) in the center of the outer sill flush against the back of the
inner sill. See FIG.11.
INSTALLATION FOR OTHER TYPE WINDOWS:
Dimensions and geometry of windows are different according to manufacturer's. Check your window and refer to FIG. 12 to install the support bracket firmly.
(a) When window frame is located on inner sill.
Installa wood strip (window width longand window frame heighthigh) on the inner sill.
SASH WINDOW ..............................
wood strip mounted on
1-1/2" min. 7/8"(22mm)
(38mm) clearance
top of inner sill
i
frame _' window
storm
iNDOOR OUTDOOR
When storm window
frame is located onouter silt
FIG. 11
(b) When the window frame is higher than 23/32"(18mm).
Install a wood strip (about 4"(102mm)long) on the outer sill to raise support bracket.
WINDOW FRAME.....................
FIG. 12
Loading...