continuedfrompage7
Forwall or roofventingmethods:
Choose betweenroof venting or wall venting.
If the wall exhaust method is chosen, besure that there is
proper clearancewithin the wall for the exhaustvent.
Vent materialsneededfor installationare notincluded.
Wall and roofcaps musthave back-draftdamper.
We recommend:
v' using rigid metal vent.
v' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
v' that size of vent should be uniform.
v' using duct tape to seal all joints in the vent system.
v' using caulking compound to seal exterior wall or roof
opening around cap.
v' two elbows should not be installed together.
We do NOTrecommend:
v' flexible metal vent.
NOTE:If flexible metal vent must be used, calculateeach
foot of flexible metal ventas two feet of rigid metalvent.
Flexiblemetal elbows count twice as much as standard
elbows.
Roofventing
Salida dealre per el cieloraso
roof cap
¢aperuzade cielo raso
3-1/4"x10" through*the-roof
atrav_sdelcielorasoperunorificio
de3-1/4"x 10
Wall venting
Salida dealre per la pared
wallcap
caperuz_depared
3-1/4" x 10" through-the*wall
a trav6sde la pared par un
orificio de 3-1/4" x 10
Roundventtransition
Transici6ndeconductodesalidade aire redondo
roof cap _ _,.,-,.._
caperuzade _ / k
cielo raso
6" min. diameter roundvent _ [ [ wall sap
conductode salida de aire ] ."-_t_. ...... ._,._,..M_-,_
redondode6"dedi_metro I" I _ _---, ,_ ._-_-'.=_._
coda
3-1/4" x10" to 6" round vent
transition
transicibndeconductodesalida
3" minimum height (required
for damper tofully open)
Altura minima de 3"
(necesaria para qua la
compaerta se abra
nompletamente)
deaireredondode3-1/4"x16"
a6"
vienedela p_,gina7
Para m_todos de salida de aire a trav6s de la pared oel
cielo raso:
Decidaentre instalar la salida de aire atravds del cielo raso o
de una pared.
Si sedecide par el mdtodo de salida deaire a travds de la
pared,aseg_resede que hayael espacioadecuadodentro de
la pared parael conducto de salida deaire.
No se incluyenlos materiales del conductode salida deaire
que se necesitanpara la instaiaci6n.
Las caperuzaspara cielo rasoy pared debentener
compuertade contratiro.
Recomendamos:
v' usar un conducto de salidade aire met_lico y rigido.
v' que la Iongitud del conducto desalida de airey el n_mero
de codas se mantengana un minima pare Iograr un
rendimiento eficiente.
v' que las dimensiones delconducto sean uniformes.
v' usar cinta pareconducto pare sellartodas las uniones en el
sistema de salidade aire.
v' usar masilla parecalafatear paresellar la paredexterior ola
abertura enel cielo raso alrededorde la caperuza.
v' no se debeninstalar dos codas juntos.
No recomendamos:
v' conducto de salida deaire met_lico flexible
NOTA:si debeusarse un conducto metdlico flexible, calcule
cada piede conducto metdlico flexible coma si fueran dos pies
de conducto metdlico rigido. Los codas de metalflexible hacen
par dos codas estdndar.
8
Recommendedventlength:
Use3-1/4°X 10"rectangular or 6" round vent.
Thetotal length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceedthe
equivalent of 140 feet of 3-1/4" X 10"rectangular or 6"
diameter round vent.
Forbest performance, use nomore than three 90 degree
elbows.
Tocalculate the length of system you need,add the
equivalent feet for eachvent piece used in the system. See
the following examples:
3-1/4"x 10" ventsystem:
1 - 3-1/4" x 10"
90° elbow = 25 ft.
1 - wall cap = 40 ft.
8 feet straight 8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6"vent system:
1 - transition = 5 ft.
2 - 90° elbows 20ft.
1 - wall cap = 40 ft.
8 feet straight 8 ft.
Lengthof 6" system = 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be usedand arectangular 3" extensionvent between
the damper assemblyand adapter must be installedto
preventdamper from sticking.
Recommendedstandardfittings
Accesoriosest_ndarrecomendados
3-1/4"x lO"to 6" =5ft.
De3-1/4"x1_'a6"=
5pies
3-1/4'x 10"roofcap=24 ft.
Capemzadecielorasode
3-1/4"x10'= 24 pies
3-1/4"x10"
90_dbow=25 ft.
Codede90°y 3-1/4"x
1_'= 25 pies
90°elbow=lOft.
CododegO_=
10pies
3-1/4"x10"wallca
=40ft.
Coperuzadepared
de3-1/4"x10"=
40pies
45°elbow=5 ft.
Codade45°=
5 pies
3-1/4"x10'flat
eibow= 10ft.
Codapianode3-1/4"
x 10"= 10 pies
3-1/4"x 10" ventsystem
Sistemade salidadeaire de 3-1/4" x 10"
3-1/4" x 16"
90° elbow
Codade90° y 6 It.
3-1/4"x1_ _6pies_ n wallsap
T" ] I H_caperuzade
' I}> parud
U 2_t. (2 pies)
6"vent system
Sistemade salidadeaire de 6"
90°elbows
codode 90°
2
transition
transici6n
2 ft. (2 pies)
Longitudrecomendadadel conductode salidade aire:
Useun conducto de salidade aire rectangularde 3-1/4_x 10"
o redondo de 6".
La Iongitud total del sistema de salida de aire, incluyendo el
conducto de salidade aire recto, el coda, lastransiciones, las
caperuzasde paredo cielo raso no deben excederel
equivalentea 140 pies de conducto rectangular de salida de
aire de 3-1/4" x 10" oconducto redondo de6" de didmetro.
Paramejores resultados, no usem_s detres codas de 90°.
Paracalcular la Iongitud del sistema que necesita,agregue la
equivalenciaen pie paracada pedazode conducto usado en el
sistema. Vealos siguientes ejemplos:
Sistemade salidade aire de 3-1/4" x 10":
1 - Coda de 90°
y 3-1/4" x 10" = 25 pies
1 - Caperuzade pared = 40 pies
8 pies recto = 8 pies
Longitud de un
sistema de 3-1/4"x 10" = 73 pies
Sistemade salidade aire de 6"
1 -transici6n = 5 pies
2 - codas de 90° 20 pies
1 - caperuzade pared = 40 pies
8 pies recto 8 pies
Longitud de un
sistema de 6" = 73 pies
Si el actualconducto de salidade aire es redondo,debe usarse
un adaptador de rectangulara redondo y un conducto de
extension rectangularde 3"entre el conjunto de lacompuerta
y se debeinstalar eladaptador pare evitar que lacompuerta se
atasque.
9