Kenmore M32701 User Manual

OWNER’S MANUAL
MODEL D42 M32701
ELECTRONIC AIR CLEANER, IONIZER & VOC FILTER
IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT
Lifetime Electronic Filter never needs replacing—simply washes clean
Electronically removes dust, mites, pollen, pet dander, mold, bacteria, viruses,
tobacco smoke, cooking smoke and grease, and more down to 0.01 micron
Activated Carbon Odour & Gas (VOC) Removal Filter removes Volatile Organic Compounds emitted from common sources within the home and office
Dual Negative Ionizer restores the air’s natural ion balance
Quiet 3-Speed Fan is comfortable for room occupants
Performance Indicator Light shows Air Cleaner is operating properly at a glance
Ideal for rooms up to 320 ft² (29.5 m²) for one room air change every 20 minutes
SEARS CANADA INC., TORONTO, ONTARIO, M5B 2B8
BENEFITS
Helps provide relief from allergy, asthma and respiratory
illness.
Helps clear a smokey environment quickly, so everyone
can work and relax together.
Helps reduce the time and money spent cleaning and
redecorating. Prevents damaging black dust from staining walls, upholstery and window coverings.
Helps reduce tobacco, cooking and pet odours.
Revitalizes the air with healthy negative ions.
Improves indoor air quality for a fresher, more
comfortable environment, year-round.
1 Dirty Air
2 Prefilter
3 Ionizing Section
4 Collecting Cell Plates
5 Odour & Gas Removal Filter
7 Negative Ions and Clean Air
6 Ionizing Needle
HOW IT WORKS
Dirty air is drawn in through the front grill and passes through a 4-stage filtering system.
The Prefilter consists of aluminum mesh and a close knit polymesh. It prevents larger particles, lint and hair from entering the collecting cell.
The next step is a 2-Stage Electrostatic Collecting Cell. Dirt particles are charged with a high positive voltage by a series of fine ionizing wires. The charged particles are drawn through to the collecting plates where the dirt adher es to the grounded plates, and remains until the cell is taken out and washed. Removes particles down to 0.01 micron (1/2,540,000 of an inch).
The air is then drawn through an Activated Carbon Odour & Gas VOC (Volatile Organic Compound) Removal Filter to help remove offensive odours and gases. Clean air is then discharged out the top of the Air Cleaner.
Dual Negative Ionizer needles are located in the clean air stream. Adding healthy negative ions to the air revitalizes the air similar to that near a waterfall, spring, the ocean, or after a rainfall. Studies have shown that negative ions have a beneficial effect on human biochemistry, both physically and mentally.
OPERATING INSTRUCTIONS
1. Remove the Air Cleaner from the box and check for apparent damage. If your unit has any signs of damage, immediately contact the store where the Air Cleaner was purchased.
2. Keep the shipping carton in case the need arises to store or transport the unit.
3. Remove all packaging from the unit. Choose a suitable table or stand to allow unobstructed circulation from front and top of unit. The unit performs best when the back is against a wall. This enhances air circulation. To mount unit on wall, refer to the Wall Mount Instructions.
4. Operate Air Cleaner at voltage shown on back of unit.
5. The System Switch controls the power to the Fan Control Switch and the power board. When the System Switch is ON, the green light behind the front grill will be illuminated.
1
2 3 4 5 6
1 - Lid which activates Safety Interlock 2 - Negative Ion Emitter 3 - Negative Ion Control Switch 4 - 3-Speed Fan Control Switch 5 - System Switch 6 - Operation Lights
6. The Fan Control Switch in the front position is low speed, the center position is medium, and the rear position is high speed.
Use the low or medium speed for quiet, continuous or nighttime use. Use the high speed for initial cleaning of heavy concentrations of dirty air (i.e. smoke) or after leaving the room.
7. The negative ions are controlled by a separate switch located behind the fan control switch. When the switch is ON, the red light will be illuminated. Note: The
Negative Ion Emitter will not work without the System Switch being ON.
8. T o access the prefilter, co llect ing c ell or activ ated car bo n filter, press firmly on the right front dimple on the lid and release. Lift the lid releasing it from the magnet.
You may notice arcing or snapping from the cell. It is normal to hear some arcing when the unit is new or first turned on. Arcing in the cell may also be caused by high humidit y (over 80%), after washing, or when a large particle of dirt or hair is caught in the cell. If the arcing is continuous and constant, then refer to the Troubleshooting Chart.
WALL MOUNT INSTRUCTIONS
1. To mount Air Cleaner on wall, remove the rear feet (2) from the bottom of the Air Cleaner, to expose the keyhole slots.
2. To remove the feet from the Air Cleaner, you will need a small, flat screwdriver. Pry up the center pin of the rear foot until the head protrudes above the foot. Place the flat portion of the screwdriver under the foot and pry u p. This will release the foot from the cabinet. Keep the feet in case you wish to table mount the unit in future.
3. Find the location on the wall where you wish to place the Air Cleaner. The unit should be placed 3 feet (1 m) below the ceiling. Use appropriate fasteners for the type of wall the unit will be mounted and insure the head of the screw will fit into the larger opening of the keyhole slot. The screw head should be larger than the smaller opening of the keyhole. The Air Cleaner weighs approximately 20 lbs (9 kg). The distance bet ween the holes in the cabinet bottom is 16 3/4 in (42.5 cm).
4. After placing the screws in the wall, adjust the amount of the screw sticking out to approximately 1/8 in (.32 cm). Place the Air Cleaner over the screw head and allow the head to slip into the keyhole slot. Pull the unit down slightly to allow the screw head to slide into the smaller portion of the slot.