Kenmore FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS Installation Instructions Manual

Page 1
INSTALLATIONINSTRUCTIONS
FREESTANDINGELECTRICRANGE WITH DOUBLEOVENS
TableofContents
RANGE SAFETY ............................................................................. 1
INSTALLATION REQUIREMENTS ................................................ 2
Tools and Parts ............................................................................ 2
Location Requirements ............................................................... 2
Electrical Requirements ............................................................... 4
INSTALLATION INSTRUCTIONS .................................................. 5
Unpack Range ............................................................................. 5
Adjust Leveling Legs .................................................................... 5
Install Anti-Tip Bracket ................................................................ 5
Electrical Connection ................................................................... 6
Verify Anti-Tip Bracket Location ................................................ 11
Level Range ............................................................................... 11
Complete Installation ................................................................. 11
Moving the Range ..................................................................... 12
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
iMPORTANT:
Save for local electrical inspector's use.
W10160642A
Page 2
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
1.__ l Tip Over Hazard
Reconnect the anti=tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults.
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Tape measure
Level
Phillips screwdriver
Flat-blade screwdriver
Parts supplied
Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block) 3 - Terminal lugs
Oven racks 2 - #12 x 1%" screws (for mounting anti-tip bracket)
Anti-tip bracket (taped inside upper oven with literature package)
Anti-tip bracket must be securely mounted to back wall or floor. Thickness of floor may require longer screws to anchor
bracket to sub-floor. Longer screws are available from your local hardware store.
Parts needed If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1%" (3.5 cm)
diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See "Electrical Requirements" section.
It is recommended that all electrical connections should be made by a licensed, qualified electrical installer.
Wrench or pliers %" nut driver
Hand or electric drill 1/8"(3.2 mm) drill bit
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the control panel.
The range should be located for convenient use in the kitchen.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti- tip bracket shipped with the range, see "Install Anti-Tip Bracket" section.
Grounded electrical supply is required. See "Electrical Requirements" section.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This range has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, the Standard for Manufactured Home Installations,
ANSI A225.1/NFPA 501A or with local codes. Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be
revised. See "Electrical Connection" section.
Page 3
Product Dimensions
A
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height.
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls with zero clearance.
b
A. 467/8'' (119.9 cm) B. Model/serial number plate
(located behind the control
panel) *
C. 357/8'' (91.4 cm) D. 297/8'' (75.9 cm) E. 26%6"-27¼" (66.8- 69.2 cm)**
*Serial number plate may be rotated up from behind the control
panel for viewing from the front of the range.
**Excludes handle. Dimension given is from wall to front of oven
door and will vary based on electric outlet receptacle installation.
H
A. 13" (33 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop, see NOTE.
D. 30" (76.2 cm) min. opening
width
E. Cabinet door or hinge should
not extend into cutouL
F. 3-wire shaded area* -
7" (17.8 cm) min. from left side cabinet, 53/4" (14.6 cm) max. from floor, 6" (15.2 cm)
max. width
G. 4-wire shaded area* -
10" (25.4 cm) min. from right side cabinet, 53_ '' (14.6 cm) max. from floor, 6" (15.2 cm)
max. width *Nothing located in shaded
areas can extend more than
!_±" (3.8 cm) from waft or
range will not slide all the way back.
H. 17/2'' (3.8 cm) min. from floor if
using a flush mount outlet.
NOTE: 24" (61 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4"(0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
Page 4
Ifcodespermitandaseparategroundwireisused,itis recommendedthataqualifiedelectricalinstallerdeterminethat thegroundpathandwiregaugeareinaccordancewithlocal
codes. Donotuseanextensioncord.
Besurethattheelectricalconnectionandwiresizeareadequate andinconformancewiththeNationalElectricalCode,ANSI/
NFPA70-latesteditionandalllocalcodesandordinances.
Acopyoftheabovecodestandardscanbeobtainedfrom:
NationalFireProtectionAssociation
OneBatterymarchPark
Quincy,MA02269.
WARNING:Improperconnectionoftheequipment-grounding conductorcanresultinariskofelectricshock.Checkwitha
qualifiedelectricianorservicetechnicianifyouareindoubtasto whethertheapplianceisproperlygrounded.Donotmodifythe powersupplycordplug.Ifitwillnotfittheoutlet,haveaproper outletinstalledbyaqualifiedelectrician.
Electrical Connection
To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located behind the control panel or on the oven frame behind the storage drawer panel. Refer to the figures in the "Product Dimensions" section of the "Location Requirements" section.
This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see Range Rating chart below). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
If connecting to a 4-wire system: This range is manufactured with the ground connected to the
cabinet. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the cabinet. See
"Electrical Connection." Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50R plug on the supply end.
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
@
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord are:
40-amp circuit 2 No.-8 conductors
1 No.-10 white neutral 1 No.-8 green grounding
If connecting to a 3-wire system: Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord contains 3 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 10-50P plug on the supply end. Connectors on the appliance end must be provided at the point the power supply cord enters the appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1%" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended. The range can be connected directly to the fused disconnect
(or circuit breaker box) through flexible or nonmetallic sheathed, copper or aluminum cable. See "Electrical
Connection."
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of the range.
The wiring diagram is located on the back of the range or inside the storage drawer in a clear plastic bag.
3-wire receptacle (10-50R)
Page 5
INSTALLATIONINSTRUCTIONS
U " pcsck
Excessive Weight Hazard
Use two or more people to move and install range. Failure to do so can result in back or other injury.
1. Remove shipping materials, tape and protective film from the range. Keep cardboard bottom under range.
2. Remove oven racks and parts package from inside oven.
3. To place range on its back, take 4 cardboard corners from the carton. Stack one cardboard corner on top of another. Repeat with the other 2 corners. Place them lengthwise on the floor behind the range to support the range when it is laid
on its back.
4. Using 2 or more people, firmly grasp the range and gently lay it on its back on the cardboard corners.
5. Pull cardboard bottom firmly to remove.
6. Use an adjustable wrench to loosen the leveling legs.
7. Place cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto cardboard or
hardboard.
NOTE: If height adjustment is made when range is standing, tilt the range back to adjust the front legs, then tilt forward to adjust the rear legs.
3,
When the range is at the correct height, check that there is adequate clearance under the range for the anti-tip bracket. Before sliding range into its final position, check that the anti- tip bracket will slide under the range and onto the rear leveling leg prior to anti-tip bracket installation.
f,
Remove the anti-tip bracket that is taped inside the upper oven with the literature package.
2.
Determine which mounting method to use: floor or wall. If you have a stone or masonry floor you can use the wall
mounting method.
3,
Determine and mark edge of range in the cutout space. The mounting bracket can be installed on either the left side or right side of the cutout. Position mounting bracket in cutout so that right (or left) edge of the bracket is _sAd'(2.4 cm) from the marked edge of the range, as shown.
A
...........I
f. If range height adjustment is necessary, use a wrench or
pliers to loosen the 4 leveling legs. This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to a standing position.
NOTE: To place range back up into a standing position, put a sheet of cardboard or hardboard in front of range. Using 2 or more people, stand range back up onto the cardboard or
hardboard,
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death
or serious burns to children and adults.
A. Anti-tip bracket B. Mark edge of range C. ls/_6"(2.4 cm)
2,
Adjust the leveling legs to the correct height. Leveling legs can be loosened to add up to a maximum of 1" (2.5 cm). A minimum of SAd'(5 mm) is needed to engage the anti-tip
bracket.
Page 6
4. Drilltwo1/8"(3mm)holesthatcorrespondtothebracket holesofthedeterminedmountingmethod.Seebelow.
Floor Mounting
A B
A. #12 x 1%" screws
B.Anti-tip bracket
Wall Mounting
A B
A. #12x 1%" screws B.Anti-tip bracket
5=
Using the Phillips screwdriver, mount anti-tip bracket to the wall or floor with the two #12 x 1%" screws provided.
Power Supply Cord
Electrical Shock Hazard
Disconnect power before servicing. Use a new 40 amp power supply cord. Plug into a grounded outlet.
Failure to follow these instructions can result in death, fire, or electrical shock.
1. Disconnect power. 3.
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range, Pull cover down and toward you to remove cover.
Direct Wire
Electrical Shock Hazard
Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range. Failure to follow these instructions can result in death,
fire, or electrical shock.
Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.
Page 7
Addstrainrelief.
4. Replacecord/conduitplateandinsertscrews.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
A
Assemble a UL listed conduit connector in the opening.
A. UL listed strain relief
Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
J
t
B
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and slide
cord/conduit plate down and out.
Position cord/conduit plate as shown in the following
illustration.
A. Removableretaining nut
B.Strain relief
Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
5,
Replace back panel and screws on rear of range.
6.
Complete installation following instructions for your type of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
Page 8
Electrical Connection Options
If your home has: And you will be Go to Section:
connecting to:
4-wire receptacle A UL listed, 4-wire connection: (NEMA type 14-50R) 250-volt Power supply cord
40-amp, range minimum,
power supply cord
4-wire direct A fused 4-wire connection:
disconnect or Direct wire circuit breaker
(12.7 crn) box
3-wire receptacle A UL listed, (NEMA type 10-50R) 250-volt
3-wire connection: Power supply cord
minimum,
power supply
40-amp, range cord
3=
Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
3-wire direct A fused
1" disconnect or
(2.5 crn) _ circuit breaker
3-wire connection: Direct wire
box
4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC) Mobile homes
Recreational vehicles In an area where local codes prohibit grounding through the
neutral Part of metal ground strap must be cut out and removed•
'B
A. Metal ground strap B. Ground-link screw
2=
Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground-link screw.
A. Terminalblock
B.Ground-link screw
C. Cord/conduit plate D.Power supply cord wires
4=
Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw. The ground wire must be attached first.
5=
Use %" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10-32 hex nuts•
F
D
A. 10-32 hex nut B. Ground-link screw
C• Line ! (black)
6=
Connect line 1 (black) and line 2 (red) wires to the outer
D. Green ground wire
E. Neutral (center) wire E Line 2 (red)
terminal block posts with 10-32 hex nuts.
7.
Securely tighten hex nuts. NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1%" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.
8. Replace terminal block access cover•
Page 9
3-wire connection: Power Supply Cord
Direct Wire Installation: Copper or Aluminum Wire
Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A. Terminal block B. Ground-link screw
C. Cord/conduit plate D. Power supply cord wires
2=
Use %" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10-32 hex nuts.
This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back 1" (2.5 cm) from the end of each wire.
(7.6 cm)
2. Allow enough slack in the wire to easily attach the wiring terminal block.
3. Complete electrical connection according to your type of electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the neutral
1. Part of metal ground strap must be cut out and removed.
E
A ..........
C
A. 10-32 hex nut B.Line ! (black)
D. Neutral (white) wire
E. Line 2 (red)
C.Ground-link screw
3=
Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.
4.
Securely tighten hex nuts. NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1%" (3.5 cm) diameter
connection opening, with ring terminals and marked for use with ranges.
5. Replace terminal block access cover.
A. Metal ground strap B. Ground-link screw
2=
Use Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground link screw and discard the remaining end of the ground link.
Page 10
3. Pulltheconduitthroughthestrainreliefoncord/conduitplate onbottomofrange.Allowenoughslacktoeasilyattach wiringtotheterminalblock.
6. Use%"nutdrivertoconnecttheneutral(white)wiretothe centerterminalblockpostwithoneofthe10-32hexnuts.
D
F
E
A. Terminal block B. Ground-link screw
C. Cord/conduit plate D. Line 2 (red) wire
4.
Attach terminal lugs to line I (black), neutral (white), and line 2
E. Neutral (white) wire
F. Line ! (black) wire
G. Bare (green) ground wire
(red) wires. Loosen (do not remove) the set screw on the front of the terminal lug and insert exposed wire end through
bottom of terminal lugs, Securely tighten set screw to XX Ibs- in. torque. See Bare Wire Torque Specifications chart.
/ E
C
A. 10-32 hex nut B. Line 1 (black)
C. Bare (green) ground wire D. Ground-link screw
b
E. Neutral (white) wire F Line 2 (red)
G. Terminal lug
7. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground conductor to neutral supply wire.
1. Pull the conduit through the hole and conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the
terminal block.
A. Terminal lug B. Set screw
C. Line 1 (black) wire D. Neutral (white) wire
E.Line 2 (red) wire
Bare Wire Torque Specifications Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg Torque 8 gauge copper 25 Ibs-in. (2.8 N-m)
6 gauge aluminum 35 Ibs-in. (4.0 N-m)
5. Use Phillips screwdriver to connect the bare (green) ground wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other terminal.
10
A. Terminal block B. Ground-link screw
C. Cord/conduit plate
F
D. Line 2 (red) wire E. Bare (green) ground wire F. Line ! (black) wire
Page 11
2,
Attach terminal lugs to line I (black), bare (green) ground, and line 2 (red) wires. Loosen (do not remove) the set screw on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten set screw to XX Ibs- in. torque. See Bare Wire Torque Specifications chart.
g B
B
Slide range back so rear range foot is engaged with anti-tip bracket.
C D
A. Terminal lug B. Set screw
C. Line 1 (black) wire D. Bare (green) ground wire
E.Line 2 (red) wire
Bare Wire Torque Specifications Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg Torque
8 gauge copper 25 Ibs-in. (2.8 N-m) 6 gauge aluminum 35 Ibs-in. (4.0 N-m)
3. Use %" nut driver to connect the bare (green) ground wire to the center terminal block post with one of the 10-32 hex nuts.
F
E
D
C
A. 10-32 hex nut
B. Line 1 (black) C. Ground-link screw
D. Bare (green) ground wire
& Line 2 (red) F. Terminal lug
4. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Making sure the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to floor or
wall.
Place rack in oven. Place level on rack and check levelness of range, first side to side; then front to back.
2. If range is not level, pull range forward until rear leveling leg is removed from the anti-tip bracket.
3. Use wrench to adjust leveling legs up or down until range is level. Push range back into position.
4. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking conditions.
1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check that the range is level. See "Level Range."
5. Use a mild solution of liquid household cleaner and warm water to remove waxy residue caused by protective shipping material. Dry thoroughly with a soft cloth. For more information, read the "Range Care" section of the Use and
Care Guide.
6. Read the range Use and Care Guide.
7. Plug power cord into appropriate outlet. Slide range into its final location. Check that the flexible conduit or power supply
cord are not bent.
8. Turn power on. Turn on surface burners and oven. See the Use and Care Guide for specific instruction on range operation.
If range does not operate, check the following:
Household fuse is intact and tight; or circuit breaker has not tripped.
Range is plugged into an outlet.
Electrical supply is connected.
See "Troubleshooting" inthe Use and Care Guide. When the range has been on for 5 minutes, check for heat. If
range is cold, turn off the range and contact a qualified technician.
11
Page 12
For direct-wired ranges:
Tip Over Hazard
A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved. Failure to fellow these instructions can result in death
or serious burns to children and adults.
When moving range, slide range onto cardboard or hardboard to avoid damaging the floor covering.
If removing the range is necessary for cleaning or maintenance:
For power supply cord-connected ranges:
1. Slide range forward.
2. Unplug the power supply cord.
3. Complete cleaning or maintenance.
4. Plug in power supply cord.
5. Check that anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to floor or wall.
Slide range back so rear range foot is under anti-tip bracket.
Electrical Shock Hazard
Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Slide range forward.
3. Complete cleaning or maintenance.
4. Check that anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to floor or wall.
Slide range back so rear range foot is under anti-tip bracket.
5.
Reconnect power.
6.
Check that range is level.
6.
Check that range is level.
W10160642A
© 2007. Whirlpool Corporation, All rights reserved.
Printed in U.S.A.
10/07
Loading...