Kenmore Elite 8.0 cu. ft. Steam Electric Dryer, Elite 8.0 cu. ft. Steam Gas Dryer Measurement Cheat Sheet

Shown with washer 26-41102 and optional drawer pedestals 26-58892
Kenmore Elite Front-Loading Steam Dryer
Electric Dryer Gas Dryer
White 26-81102 White 26-91102 Lemongrass 26-81101 Lemongrass 26-91101 Blackberry 26-81100 Blackberry 26-91100
• 8.0 cu. ft. capacity
• Steam Care with direct water hook up
• Electronic LED SmoothTouch controls
• 15 drying cycles and 12 drying options
• Sensor drying with 4 moisture sensor bars in the drum
• Steam Refresh cycle
• NSF® Certified sanitize cycle
• Drying rack
• Stainless steel drum
• LED drum light
• Reversible side-swing door with see-through window
• 4-way electrical / gas kitless rear venting
Gas Dryer Connector – Stainless Steel
26-49590
26-49585*
*Los Angeles only
1
/2" - 3/8" Flex, 5 ft.
3
/8" - 3/8" Flex, 5 ft.
POWER CORDS FOR ELECTRIC DRYERS ONLY
26-49387, 26-49787
*Complies with 1/1/96 NEC code revision for new construction and remodeling
All Electric Dryers Require Cord
Order Wire Length
26-49387 3 4 ft.
26-49787 3 6 ft.
26-49388* 4 4 ft.
26-49788* 4 6 ft.
26-49388, 26-49788
26-81102/1/0, 26-91102/1/0
Page 1 of 2
SELECTION ELITE
Electric Dryers:
White 26-81102
Lemongrass 26-81101
Blackberry 26-81100
Gas Dryers:
White 26-91102
Lemongrass 26-91101
Blackberry 26-91100
DRYER FEATURES STEAM
Capacity (cu. ft.)
Steam Care
Soft Heat Technology
Temperature Selections
Sensor Drying System
CYCLES AND OPTIONS 15 / 12
Heavy Duty, Allergen, Sanitize
(NSF® Certified), Khaki / Jeans,
Towels, Bulky Bedding, Delicates,
Specialty Cycles and Options
Steam Cycles and Options Steam Refresh
Timed Drying
Express Dry
Extra Dry
Air Dry
Wrinkle Guard®
More Time / Less Time
Add Steam
CONVENIENCE FEATURES
Drying Rack
Check Vent
Time Remaining Display
Status Indicator(s)
Damp Dry Signal
Drum Light
Control Lock
Venting Electric / Gas
Rear Venting Duct Elbow #49609
GENERAL FEATURES
Controls Electric LED SmoothTouch
Stainless Steel Drum
Door Configuration
See-Through Window
Optional Pedestals
Stackable Installation Kit
Electric Volts / Hz / Amps
Electric Dryer Circuit Requirements (60Hz)
Gas Dryer Rating: Volts / Hz / Amps
Gas Burner BTU / Hour
LP Gas Conversion Kit
Gas Pipe Size (O.D. Inches)
DIMENSIONS / WEIGHT
Product Dimensions (Inches) (H x W x D x D with Door Open) 38 x 27 x 31
Item Weight (Approx. Lbs.)
Shipping Weight (Approx. Lbs.) 130
WARRANTY
1-Year Limited Warranty – Mechanical and Electrical Parts Parts & Labor
If used for other than private family purposes, warranty applies for only 90 days.
Mixed Load, Normal / Casual,
Touch Up, Install, Automatic Dry
4-Way Kitless Rear Venting /
8.0
8 Cycles
5
4 Moisture Sensor Bars
Up to 60 Minutes
Up to 60 Minutes
Included
LED
4-Way Kitless Rear Venting
Reversible
26-58890 / 1 / 2
Included
240 / 60 / 30
30 Amp Circuit Breaker
Time Delay Fuse
120 / 60 / 15
20,000
26-38239
3
/8
1
/2 x 53 1/2
130
03311
Due to Sears policy of continuous improve ment on its products, Sears reserves the right to change materials and specifications without notice. Before installing, consult installation instructions packed with product for current dimensional and installation data.
26-8110X.PDF
Effective 04/25/11
26-81102/1/0, 26-91102/1/0
4"
1
4"
2
/
"
53 1/2"*
to clear
open door
27"
electrical supply on
rear of unit
4
centerline height for rear vent
19"
3
7
/10"
1
1
/2"
3
3
/4"
38"
17"
gas
supply
pipe on
rear of
gas unit
13 1/2"
to center of rear vent
freestand
dryer on floor
floor line
floor line
dryer mounted on
optional pedestal
53 1/4"
31 1/2"*
to front of closed door
53 1/2"*
to clear
open door
27"
electrical supply on
rear of unit
4
centerline height for rear vent
19"
3
7
/10"
1
1
/2"
3
3
/4"
38"
17"
gas
supply
pipe on
rear of
gas unit
13 1/2"
to center of rear vent
freestand
dryer on floor
floor line
floor line
dryer mounted on
optional pedestal
53 1/2"*
to clear
open door
75 3/4"
27"
centerline height for rear vent
41"
39"
water
supply
connection
on rear
of unit
1
drain hose
on rear of unit
3
electrical supply on rear of unit
4
power cord on rear of unit
2
gas supply
pipe on rear
of gas unit
floor line
53 1/4"
31 1/2"*
to front of closed door
31 1/2"*
to front of closed door
1"
0"
0"
0"
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.
0"
0"
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.
DRYER VENTING RECOMMENDATIONS 4" CLEARANCE BEHIND DRYER
4-WAY VENTING KIT
Call Sears Parts 1–800-225-2864
38020
26-38239
LP Kit Dryers
26-98379 — Vent Hood Aluminum body and plastic molded hood with a 4" opening.
Clamps are recommended for wall and dryer connections. Steel clamps designed to resist stretching, with phillips/hex head screw are included one each on elbows and periscopes.
Number
of 90° Turns
0 125 ft 125 ft 110 ft
1 115 ft 115 ft 100 ft
2 105 ft 105 ft 90 ft
3 95 ft 95 ft 80 ft
4 85 ft 85 ft 70 ft
4" Clearance Behind the Dryer is Preferred for Best Airflow. 2" Clearance is Achieved With Periscopes.
VENT HOOD TYPE
4"
IMPORTANT NOTE:
Do not use non-metal flexible duct. Also, when installing the venting system, do not exceed the specified length for the vent duct. Venting systems which are longer than specified will accumulate lint, increase drying time and energy use and shorten the life of the dryer.
WASHER AND DRYER DIMENSIONS / OPTIONAL PEDESTALS / STACKING KITS
Washer
Washer Dimensions W x H x D (Depth with Door Open) Dryer
26-41102 27" x 38"
26-41101 27" x 38"
26-41100 27" x 38"
1
x 31
2" (53 1⁄2") 26-8/91102 27" x 38" x 31 1⁄2" (53 1⁄2") White Included 26-58892 27" x 15" x 27"
1
x 31
2" (53 1⁄2") 26-8/91101 27" x 38" x 31 1⁄2" (53 1⁄2") Lemongrass Included 26-58891 27" x 15" x 27"
1
x 31
2" (53 1⁄2") 26-8/91100 27" x 38" x 31 1⁄2" (53 1⁄2") Blackberry Included 26-58890 27" x 15" x 27"
Dryer Dimensions W x H x D (Depth with Door Open) Color Stacking Kit Pedestal Pedestal Dimensions W x H x D
1
2
Max. Length
of 4" Dia.
Rigid Heavy
Metal Vent
26-49900 — Over-The-Top™ Kit Universal solution, 8 foot length. Kit includes two 4 ft. pipe sections with attached elbows, two close elbows, clamps and wall plate.
26-49608 — Flexible Pipe 4" x 6' with snap-lock fittings, 90˚ turn takes 1 foot length and 6 inch clearance.
26-49609 — Close Elbow Turns 90˚ within 4", rotating collars and snap-lock fittings.
2" CLEARANCE BEHIND DRYER
26-49908 — Periscope 0-18"
For outlets that overlap or are very close
26-49904 — Periscope 18-29" Reaches side of most dryers
26-49905 — Periscope 29-50" Reaches top of most dryers
Page 2 of 2
INSTALLATION OPTIONS
03311
dryer mounted on
optional pedestal
53 1/2"*
to clear
open door
freestand
dryer on floor
floor line
floor line
31 1/2"*
to front of closed door
38"
53 1/4"
Closet Door
3"
3"
60 sq. in.
60 sq. in.
Due to Sears policy of continuous improve ment on its products, Sears reserves the right to change materials and specifications without notice. Before installing, consult installation instructions packed with product for current dimensional and installation data.
supply
pipe on
rear of
gas unit
1"
gas
17"
1
1
/2"
3
/4"
3
13 1/2"
to center of rear vent
*Connection of water inlet hose on steam dryer adds
1
Power supply cord length on gas dryer approximately 60 inches.
2
Hot and cold inlet hose length on washer approximately 48.5 inches.
27"
electrical supply on
4
rear of unit
3
centerline height for rear vent
7
/10"
19"
53 1/2"*
to clear
open door
3
/4 in. to installation depth.
31 1/2"*
to front of closed door
0"
0"
floor line
0"
Installation in a recess or closet
1. A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: a minimum of 120 square inches of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.
3
Drain hose length on washer approximately 59 inches.
4
Power supply cord length on washer approximately 60 inches.
27"
75 3/4"
water
supply
connection
on rear
1
of unit
gas supply
pipe on rear
of gas unit
39"
drain hose
on rear of unit
3
26-8110X.PDF
electrical supply on rear of unit
centerline height for rear vent
power cord on rear of
2
unit
4
41"
Effective 04/25/11