Congratulations on your selection of a new Kenmore dehumidifier. Your Kenmore dehumidifier has been designed and manufactured to a high standard of quality, tested and inspected by competent personnel. To help you obtain the full benefits of your dehumidifier, we recommend that you read all of the enclosed instructions.
CONTENTS
PAGE
WARRANTY INFORMATION 1
HOW YOUR KENMORE DEHUMIDIFIER OPERATES 2
BEFORE USING YOUR KENMORE DEHUMIDIFIER 2
OPERATION OF YOUR KENMORE DEHUMIDIFIER 2
KNOW YOUR KENMORE DEHUMIDIFIER 3
DONT’S TO REMEMBER 3
FEATURES AND THEIR FUNCTION 4
TROUBLESHOOTING 4
CARE AND UPKEEP 5,8
LIMITED WARRANTY
(From date of purchase)
COMPRESSOR AND SEALED SYSTEM
PARTS AND LABOUR (5) FIVE YEARS
ALL OTHER PARTS AND LABOUR (1) ONE YEAR
THIS WARRANTY IS IN ADDITION TO ANY STATUTORY WARRANTY
IF ANY SERVICE IS REQUIRED, CONTACT YOUR NEAREST SEARS OUTLET
SEARS CANADA INC., TORONTO M5B2B8
1
HOW YOUR KENMORE DEHUMIDIFIER OPERATES
The fan which has a permanently lubricated motor, draws moisture-laden air over a refrigerat­ed evaporator coil which condenses the moisture and returns the treated, dry air to the room.
The automatic water overflow control stops the unit when the moisture collecting pan is full and (on some models) a signal light reminds you to empty the pan. The unit starts again automatical­ly when the pan is removed for emptying so be sure to replace the pan immediately.
A hose can be attached to the dehumidifier for continuous drainage of collected water. The automatic humidistat (on models so equipped) maintains your room at the desired degree of dryness.
to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.
OPERATION OF YOUR KENMORE DEHUMIDIFIER
WARNING: Do not use dehumidifier near
highly volatile substances, such as gasoline.
(a) Allow the unit to warm to room temperature
before operating.
BEFORE USING YOUR KENMORE DEHUMIDIFIER
Electrical Requirements
It is best to use a separate 115-volts, 60 cycle, AC grounded, 15-ampere breaker or time delay fuse protected electrical supply. This will help to eliminate current fluctuation, which might cause compressor trouble.
Grounding Instructions
OBSERVE ALL LOCAL GOVERNING CODES AND REGULATIONS.
Do not, under any circumstances, remove the power supply cord ground prong.
For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a 3-prong grounding plug. To avoid possible shock hazard, the cord must be plugged into a mating 3-prong grounding-type wall recep­tacle, grounded in accordance with the Canadian or Provincial Electrical Code and local regula­tions. If a mating wall outlet is not available, it is your responsibility and obligation
(b) Your Kenmore Dehumidifier can be placed
almost anywhere but don't block either end of the unit. The dehumidifier takes air from the back and blows it out from the front. So wherever you place it, be sure there's enough room for good air movement and moisture pan removal. Minimum recommended distance 4".
(c) Your dehumidifier can be operated in an
out-of-the-way area and still effectively dry out adjoining areas. However, it is helpful to leave doors open between these areas so the moisture in the air can move from room to room.
(d) To dehumidify a specific area, close all
doors and windows leading to that area.
ROOM TEMPERATURE
A Kenmore Dehumidifier will work most effec­tively at temperatures above 18°C (65°F). Refer to the performance chart on Page 6.
The coil of any dehumidifier can become blocked with ice at room temperatures below 18°C (65°F). Ice build up on the coil stops the air flow through the dehumidifier and it stops dehumidifying even though it keeps running.
2
Models with Frostguard™ De-icer Control
The Frostguard™ de-icer senses ice build up on the evaporator coil and automatically shuts off the compressor. The fan continues to run, drawing air across the coil and melting the ice. When the coil is defrosted, the Frostguard™ de-icer sensor restarts the compressor auto­matically. Refer to the performance chart, on the water pan operating temperatures at various relative humidity levels.
Models without Frostguard™ De-icer Control
If icing should occur, unplug unit until ice melts and room temperature is above 18°C (65°F).
"
DONT’S" TO REMEMBER
1. Don't alter or change the plug on the power
supply cord of your dehumidifier. Changes would make it unsafe, could cause serious damage to the dehumidifier, and might void this warranty.
2. Don't plug in the dehumidifier if you are in
doubt about the grounding of your electrical system. Consult a qualified electrician first.
3. Don't use a lamp cord. If necessary use an
approved grounded appliance extension cord with a maximum length of 6 ft. and minimum wire thickness of 14 guage.
4. Don't use a circuit that will become
overloaded when the dehumidifier is added.
5. Do not sit or stand on the dehumidifier.
KNOW YOUR KENMORE DEHUMIDIFIER
FILTER - BACK GRILLE
EVAPORATOR COIL (LOCATED BEHIND GRILLE)
HUMIDISTAT
DIRECT TO DRAIN FITTING
FAN SPEED CONTROL
FLOAT MOISTURE PAN
MODEL/SERIAL NO. PLATE BEHIND PAN
THIS OWNER'S MANUAL COVERS ALL KENMORE DEHUMIDIFIER MODELS.
Your model number can be found on a decal located in the rear of the unit behind the moisture pan.