Kenmore 91195982990, 91195987990, 91195989990, 91195409000, 91195402000 Installation Guide

...
INSTALLATION iNSTRUCTIONS FOR YOUR NEW
FREEoSTANDINGELECTRIC NGE
Before you begin. Read these instructions completely end carefully.
nMPORTANT. Save these instructions for local inspector's use. IMPORTANT - OBSERVE ALL GOVERNB_G CODES AND ORDINANCES.
Note to HnstaHer . Be sure to leave these instructions with the Consumer.
Note =o Consumer. Keep t_ese instructions with your Use and Care Book for future
reference.
house fuse or open circuit breaker | CAUTION: For personal safety remove
before beginning instaMation. Failure | to do so could result in serious injury |
°re'e, de h.................. J
All rough-in and spacing dimensions must be met for safe use ofyour range Electricity to the range can be
disconnected at the outlet without moving the range if the outlet is in the preferred location (remove lower drawer)
Toreduce the risk of bums or fire when reaching over hot
surface elements, cabinet storage space above the cooktop should be avoided If cabinet storage space is to
be provided above the cooktop, the risk can be reduced by installing a range hood that sticks out at least 5" beyond
the front of the cabinets Cabinets installed above a
cooktop may"be no deeper than 73" Be sure your appliance is properly installed and grounded
by a qualified technician
tipping the appliance, the appliance WARNING: To reduce the ri_k of
must be secured byproperly iestafied
anti.tip device packed _Jith the appliance,
Fig. 1
ADJACENTCABINETORFINAL LOCATIONOF_NGE
WAll
REAR
LEVELINGLEG
Installationinstructionsareprovided for woodand concrete in eitherfloor or wall Any othertype of constructionmay
requirespecialinstallationtechniquesas deemedneces- sary toprovide adequatefasteningof theANTI.TIP
brackettothe floorand wall
Theuse ofthis bracketdoes notpreclude tipping of the
range whennot properlyinstalled NOTE: TheinstallationoftheANTI.TIP bracket must
meetalllocal codesfor securing appliance
Flat blade screwdriver I 7/15"open end OF
5/t6" hex head screwdriver adjustable wrench
Drill with 7/8" bit !/4" Hex Head
Phillips head screwdriver screwdriver
Unlessproperlyinstalled,therange ':
could be tipped by steppingor sittingon ::
hot liquidsor fromtherangeitself
Thisrangehasbeendesigned tomeet
all normalconditions
, fnstatfAnti-tip Devicepacked withrange .. [
.SeeInstallationInstructions
31-10301-1 229C4o53P'! 04,,2 I
Step 1 - Locating #_e bracket
1. Locate the bracket against the rear wall and either the
right or left cabinet. If the countertop overhangs the cabinet, offset the bracket from the cabinet by the
amount of overhang, tf there is no adjacent cabinet. position the edge of the bracket at the desired location
of the range side panel
continued...
N D 348_02
2, Usethe bracketas atemplateand markthe4 required
holesasshownin Fig, I for thetype ofconstructionas indicated in Step 2
Step 2. Anti.Tip bracket installation
Wood Construction
1, Floor: Locatethe centerof thetwoholesidentified in
Fig. 1asFLOOR-WOOD,Drilla 7/8"pifotholein the centerof eachhole (a nailor awl maybe usedif a drill isnotavailable),AND
2, Wall: Locatethetwo holesidentified in Fig, 1 as WALL°
Drillan angled t/8" pilot hole (asshowninFig. 2) in the centerof eachhole (anail or awlmaybeused ifa drill isnotavailable)
MounttheANTI-TIPbracket withthe4 screwsprovided as illustratedinFig, 2
Concrete Construction
I. HardwareRequired: 4 each 1/4°x 7-7/2_Iag bolt
(notprovided) 4 each 1/2"0 D sleeveanchor
2. Drilltherecommendedsizehole forthe anchorsintothe concreteat thecenterof the holesidentified asFLOOR-
CONCRETEand WALL. tnstaflthesleeveanchorinto thedrilled holesand then installthe lag bolts through
thebracket Thebolts mustbeproperly tightenedas recommendedforthe hardware
Step 3 - Checking the Installation
Io Completethe installationof therangeper theinstallation
instructionsprovided withtheproduct
2. Checkifthe ANTI-TIPbracketis instafledand engaged
properly Removethekick panel or storage drawerand
inspecttheREAR LEVELINGLEG.Makesure itfits
securelyintothe slot
SeeFigures 3 and4 for allrough-inandspacing dimensions
Therangemaybe placed withO"clearance(flush)atthe
back wallandside wallsoftherange
Fig. 3
I[
i
T
18 = MIN
0 w .._
i
WtlNIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS, AND ABOVE COOKTOP
" RECOMMENDED SPACING TO HEAT SENSITIVE
SURFACES.
Makesurethewall coverings, countertopand cabinets aroundtherange can withstandtheheat (up to200_F)
generatedby therange
Fig. 4
ACCEPTABLEELECTRICAL OUTLETAREA
Orienttheelectrical receptaclesothe
isparalleltothefloor.
21f2"
NOTE:Usea 4foot powercordtoprevent interferencewith the storagedrawer.
Longerpowercords mayhaveto be
dressedtoallow for properdrawerclosure,