For Models with 4 Standard Sealed Top Burners
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
THIS CONVERSION KIT MUST BE INSTALLED BY A QUALIFIED SERVICE TECHNICIAN
IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND ALLAPPLICABLE CODES AND
REQUIREMENTS OFTHE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW INSTRUCTIONS
MAY RESULT IN FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE QUALIFIED SERVICE AGENCY IS RESPONSIBLE
FOR TH E PROPER INSTALLATION OF THIS KIT. THE INSTALLATION IS NOT PROPER AND COMPLETE
UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE
MANUFACTURER'S INSTRUCTIONS SUPPLIED WITH THE KIT.
BEFORE PROCEEDING WITH THE CONVERSION, SHUT OFF THE GAS SUPPLY BEFORE
DISCONNECTING ELECTRICAL POWER TO THE RANGE. BE SURE BOTH POWER SUPPLIES ARE OFF
BEFORE INSTALLING THE CONVERSION KIT. FAILURE TO DO SO COULD CAUSE SERIOUS BODILY
INJURY.
This kit contains the following:
Quantity Description Part Number
Top Burner Orifice Marked 0.89 mm (7,500 BTU*)
*For operation at elevations above 2000 ft., appliancerating shall be
reducedat the rate of 4 percent for each 1000 ft. above sea level.
1
4
4
4
Tools Required:
#1 Phillips Head Screwdriver (small) _--:=_
5/8" Open End Wrench
1/8" Wide Flat Blade Screwdriver
7mm Nutdriver _ _]
Installation Instructions
Restrictor-Burner
Screw-Restrictor
Choke-Burner: Small (7,500 BTU) Top Burners
7qo.-r.qTizTq l/,; 'Flo.?'...<'7,z,/qq/;
7clo.7572- _ lj "7_o.T57Z_-_q /
790.7,._77-.1qq)_; 79o. 7573-3.9q2-.,"
9o. 7xTz,Tq 2-;
7go. 75"72_'_'q2.
316010802
316105828
316011600
316064200
316056700
Espahol- P_ginas 7-12
PIN 316105828 (0001)
How to Convert the Range for use
with LP/Propane Gas
1. Convert the Pressure Regulator
To access the regulator,remove the kick panel, storage
drawer or warmer drawer. If equipped with a broiler
drawer, open drawer completely. For models equipped
with warmer drawer, follow the instructions below to
remove warmer drawer,
a. _|Nkvivl_.l_t_ll_[C'tlElectrical Shock Hazard can occur and
result in serious injury or death. Disconnect electrical
power to the range before removing the warmer
drawer for servicing.
b. Open the drawer to the fully opened position.
c. Locate glide lever on each side of drawer, pull up on the
left glide lever and push down on the right glide lever
(see figure 1).
d. Pull the drawer away from the range.
Pullup with finger
[]
Left Glide
@@ @ @@
II II
Front Access
to Regulator:
Remove Kick Panel,
StorageDrawer, or
Warmer Drawer,
(See Owner's Guide
for Instructions).
If Equipped with
Broiler Drawer.
Open Broiler Drawer.
FIGURE 2
Pressure
Regulator
location at
rear of
range
...._er
p__ L[]
FIGURE 1
e. Do not remove the Pressure Regulator or allow it to
rotate or turn. Remove the dust protector from the
cap, Using a 5/8" wrench, unscrew the cap from the
pressure regulator. Do not remove the spring from
the regulator. Do not pull on spring.
f. Turn the cap over so the hollow end faces outward.
Place the solid end of the cap into the loop end of the
dust protector as shown in illustration below.
g. Replace the cap on the regulator. The letters LP should
be visible on the exposed end of the cap. Snap the dust
protector over the regulator cap.
RightGlide
Dust
Protector
Spring i_
Hollow End Solid End
Towards Towards
Regulator Regulator
for Natural Gas for LP/Propane Gas
FIGURE 3