Kenmore 79070300706, 79070302703, 79073039310, 79073032310, 79073033310 Installation Guide

...
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
This conversion kit must be installed by a qualified service technician in accordance
with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. Failure to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions
supplied with this kit.
[F_ Before proceeding with the conversion, shut off the gas supply before disconnecting
electrical power to the range. Be sure both power supplies are off before installing the conversion kit. Failure to do so could cause serious bodily injury.
When burners are converted from Natural to LP the BTU rating is as follows: 9,000 BTU* Natural Gas to 8,000 BTU* LP Gas. The LP converstion kit contains:
P/N Part Description Notes
4 316470401
1 316417511
*NOTE; For operation at elevations above 2000 ft.; appliance rating shall be reduced at the rate of 4 peicent for each 1000 if, above sea level. After replacing the natural gas to LP orifices, be sure to keep the original factory installed natural gas orifices for future range conversion back to natural gas:
Converting the appliance for use with LP/ Propane Gas
8,000* BTU LP Burner Orifices LP Conversion Installation Instructions
marked 68L (.79mm orifice size)
c. Turn the pressure regulator cap over so the hollow end
faces toward the regulator as illustrated (See Fig. 1).
Before installing the brass pressure regulator cap, be sure
Tools Required"
to remove the dust protector and reinstall the ring portion of the dust protector. The ring portion of the protector
1/2" Open End Wrench
MUST be installed. The ring portion of the dust protector
acts as a spacer between the regulator and brass
5/8" Open End Wrench
regulator cap when converted to LP.
d: Using a 5/8" open-end wrench tighten the pressure
1/4" Nutdriver 10mm Nutdriver
or
regulator cap until snug.
e: Snap the dust protector back over the pressure regulator
cap.
10mm Open End Wrench
1. Convert Pressure Regulator
Before proceeding with the conversion,
shut off the gas supply before disconnecting electrical power to the range. Be sure both power supplies are
HOLLOW END
REGULATOR _
FOR NATURAL GAS _"
TOWARDS _ _
PRESSURE
REGULATOR
CAP
SPRING
SOLID END TOWARDS
REGULATOR
FORLP. GAS
off before installing the conversion kit. Failure to do so could cause serious bodily injury.
a. Lift and lock cooktop into raised position. Locate the gas
pressure regulator, The regulator is located atthe right rear of the burner box and is attached to the manifold pipe.
b. Unsnap the plastic dust cap protector from the brass
pressure regulator cap. Use a 5/8" open-end wrench to loosen and then remove the brass pressure regulator cap (See Fig. 1). DO NOT remove the spring from the pressure regulator.
Fig. 1
pin 316417511 (En/Fr) 0609
2. Convert Surface Burners for use with LP/
Propane Gas
a. With the cooktop still in the raised position, remove the
4 Venturi surface burners using a 1/4" nutdriver as illustrated (See Fig. 2).
b. Using a 10mm nutdriver (or 10mm open-end wrench)
remove the 4 brass Natural Gas orifices from the ends of the surface burner valves (See Fig. 3).
c. Replace the 4 brass Natural Gas orifices with the 4
brass LP Gas orfices supplied with this kit (the 4 LP surface burner orfices are marked 68L).
d. Use a 10mm nutdriver (or 10mm open-end wrench) to
tighten the LP orifices until snug. DO NOT OVERTIGHTEN.
e. Replace the 4 Venturi surface burners and secure in
place using a 1/4" nutdriver (See Fig. 2).
@@ @ @@
uY
Increase gas volume _,_
Increase flame size \
%J_L/_ Decrease gas volume
E__,_rJeCrease flame size
4_
Fig. 4
4. Reconnect Gas & Electrical Supply to Appliance
Leak testing of the appliance shall be conducted according to the Installation Instructions provided with the appliance.
Fig. 2
Fig. 3
3. Convert Oven Burner Orifice for LP/Propane
Gas (16,000 BTU*)
a. Removeoven broilerdrawerorlowerovenfrontpanel. b. Locate the oven burner spud (See Fig. 4). c. Using a 1/2" open=end wrench, turn down the adjustable
spud, which injects gas into the oven burner, until snug against the LP metering pin (approximately 2-1/2 turns).
DO NOT OVERTIGHTEN.
Checking Manifold Gas Pressure
If it should be necessary to check the manifold gas pressure, remove the burner and connect a manometer (water gauge) or other pressure device to the top right front burner orifice. Using a rubber hose with inside diameter of approximately 1/4," hold tubing down tight over orifice. Turn burner valve on. For an accurate pressure check, have at least two (2) other surface burners burning. Be sure the gas supply (inlet) pressure is at least one inch above specified range manifold pressure. The gas supply pressure should never be over 14"water column. When properly adjusted the manifold water column pressure is 10" for LP/Propane gas or 4" for Natural gas.
Do not use a flame to check for gas leaks.
a. Disconnectthe range and its individual shut-offvalve from
the gas supply piping system during any pressure testing of that system at test pressures greater than 14" of water column pressure (approximately 1/2" psig).
b. The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to orless than 14" of water column pressure (approximately 1/2" psig).