INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUAUFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasotine or other flammable vapors and Jiquids in
the vicinity of this or any other appliance.
Cooktop Dimensions
........... (76.2 cm)
b
Cooktop Cutout Dimensions
* 30" (76.2 cm) rain. for unprotected cabinet
24" (61 cm) rain. for protected surface
30" Min. *
Figure 1
IMPORTANT INSTALLATION INFORMATION
All electric cooktops run off a single phase, three-wire
or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
Minimum distance between cooktop and overhead
cabinetry is30" (76.2 cm).
IMPORTANT INFORMATION FORPROPER
INFRAREDTOUCH CONTROLFUNCTION
Inorder to prevent faulty adjustment of the
controller sensors due to foreign light, the
intensity of illumination at the first power on
should not exceed 1000 Jux.Direct irradiation
of tile touch panel with light from a spotlight
should beavoided during the power process.
If the illumination exceeds 1000 lux, the
control doesn't display the version and stop
the automatic adjustment. Inthis caseturn
down the controls switch of the light till the
illumination is lower than 1000 lux.
30" Ceramk-Glass 21% (543)
All dimensions are in inches (cm).
* Allow 2" (5 cm) space below cooktop to clear tile electric cable and allow for installation of tile junction box on the
wall at tile back of tile cooktop.
Printed in the United States P/N 318201412 (041 1) Rev C
31/4 (83) 293/4(756) 1297Is (759) 201/4 (514) 1201/2 (521) 5(127)
English - pages 1-6
Espat_ol- pages 7-12
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
Bottom of an
Unprotected Wood
or Metal Cabinet
24" (61 cm) Min when
Bottom of Wood or
Metal Cabinet is
Protected by Not Less
Than 1/8" Flame
Retardant Millboard
Covered VVith Not Less
Than No_ 28 MGS Sheet
Steel, 0015" (0_4 ram)
Stainless Steel, 0024"
(0.6 ram) Aluminum or
0_020" (0,5 ram)
Copper
2 I/2" (6.4 cm)
Mira From Edge
Cutout to Front
Edge of
Countertop
(457 cm)
18"
\
Cutout and Nearest I0"
CornbustibleSurface 254cm)
Above Countertop
Approximate Location
of Junction Box
25" Min
63_5 cm Min_)
H Min_ From Edge of
Cooktop to Nearest
Combustible Wall
(Either Side of Unit),
Drawers cannot be used with
this cooktop since burner
box extends G below
surface of countertop,
Fordimensions A, D, E& F, seeTable on page 1,
_To eliminate the risk of burns or fire by
reaching over heated surfaces,cabinet storage space located
abovethe cooktop should be avoided, If cabinet storage is
provided, risk can be reduced by installing a range hood that
projects horizontally a minimum of 5" (12_7cm) beyond the
bottom of the cabinets,
Figure 2 - COUNTERTOP CUTOUT OPENING
Important Notes to the Installer
1. Readallinstructionscontainedintheseinstallation
instructionsbeforeinstallingthecooktop.
2. Removeallpackingmaterialbeforeconnectingthe
electricalsupplytothecooktop.
3. Observeallgoverningcodesandordinances,
4. Besuretoleavetheseinstructionswiththeconsumer.
Important Note to the Consumer
KeeptheseinstructionswithyourUseandCareGuidefor
futurereference.
Electrical Requirements
Observe all governing codes and tocal ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of the appliance specified on the
nameplate.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of tile appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-
latest edition, and local codes and ordinances.
IMPORTANT SAFETY
INSTRU S
Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.
• These cooktops must be electrically grounded in
accordance with tota! codes or, in their absence,
with the National Electrical Code ANSJ/NFPA No.
70--latest edition in the United States, or with
CSA Standard C22.1, Canadian Electrical Code, Part
1, in Canada.
_The electrical power to the cooktop
must be shut off while line connections are being
made. Failure to do so could result in serious injury
or death.
Provide Electrical Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. NOTE: DO NOT connect the wire to the circuit
panel at this time. Wait until all wires have been
connected in the junction box.
An extension cord must not be used
with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.
2. The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
Tile junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
the cable between the box and the appliance, so it
can be moved if servicing is ever necessary.
3. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking Instructions
Model and SeriaBPBate
Figure 3 (Under Cooktop)
1, tf connecting to a 3-wire supply cable:
Connect the green (or bare copper) wire from the
appliance (:able and tile supply cable (green or bare)
wire to the ground screw inside the junction box (see
Figure 4). Connect the remaining wires inside the
junction box from tile power supply cable to the
matching colors of tile appliance cable wires.
Cable from Power Supply
Ground Wire
.
Leave corner supports on cooktop until completion
of Electrical Connection.
2.
Be sure the bottle of (:leaner conditioner packed in
the literature bag is left where the user can find it
easily. It is important that the ceramic-glass
smoothtop be pretreated before use see Cooktop
Cleaning and Maintenance section in the Use and
Care Guide.
Electrical Connection
Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
follows.
Electrical ground is required on this appliance,
This appliance is equipped with a copper conductor
flexible cable. If connection is made to aluminum house
wiring, use only special connectors which are approved
for joining copper and aluminum wires in accordance
with the National Electrical Code and local codes and
ordinances.
Red
Wires
Wires
Box
Ground Wire
(Bareor
Green Wire)
U.L.-Listed
Conduit
Connector
Cable from appliance
Figure 4
3-WIRE GROUNDED JUNCTION BOX
Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire, Use onty connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
This appliance is manufactured with a frame connected
green (or bare copper) ground wire.