Kenmore 79045499504, 79045494502, 79045494503, 79045494504, 79045499500 Installation Guide

...
iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
For existing 29" (73,7 cm) cutout wide opening, you 30" must call the Service Center for optional thinner side _ cm_ I
panels. Also you must prepare the countertop edge [------_-i----_ I I as shown on page 5.
These surfaces should be flat & (76,2 cm Min.) _
11/2'' Max. 1/2" min. 1/4' rain. (45,7 cm Min.)
(3,8 cm) Max.
Shave Raised Edge to Clear
Space for a 311/2" (81 cm) Wide Cooktop
Rim.
Locate Cabinet Doors 1 " (2,5 cm) Min. from
Cutout Opening
IMPORTANT: Cabinet and countertop
width should match the cutout width.
A: Cutout Width Bi Cutout Depth C, Height of
(countertop and (ACcording to front CuIEout
cabinet), of cabinet),
24" Min.
(61 cm Min.)
Grounded Junction Box in adjoining Cabinet
30+1/16" 21 3/4" (55,2 cm) min 29" (73,7 cm)
(76,2 + 0,15 cm) 22 1/8" (56,2 cm) max
Printed in United States P/N 318201614 (0510) Rev. C
English - pages 1-8
Espaflol - p_iginas 9-16
NOTES:
1.Do not pinch the power supply cord between the range and the wall.
2.Do not seal the range to the side cabinets.
3.24" (61 cm) minimum clearance between the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not lessthan 1/4" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance when the cabinet is unprotected.
4.Allow at least 20" (50.1 cm) clearance for door depth when it is open.
Smoothtop Models
48" (122 cm)
Armored
Cable
NOTE: Two sets of holes are provided under anti-tip bracket. Bracket is attached in
the upper hole position at the factory. Refer
also to page 6, item 9 for additional details.
Door open (see note 4)
Side Panel
/
/
/ /
CABINET
Figure 1
22 718" *
(58.1 cm) rain.
23 1/4"*
59.05 cm) max_
_/ _ 1 1/8"
/ (2.86 cm)
B Ref.
FRONT
OF
* For cutouts below 22 7/8", appliance
will slightly show out of tt_e cabinet.
261/2"
(67.3 cm)
i
A: CutoutW!dth I B, Cutout Depth' C, Heightof (Countertop and , (According to front Cutout
Cabinet), of cabinet),
30 _+1/16" 21 3/4" (55,2 cm) rain 29" (73,7 cm)
(76,2 _+0,15 cm) 22 1/8" (56,2 cm) max
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing range.
2. Remove all packing material from the oven before connecting the electrical supply to the range.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Oven door may be removed to facilitate installation.
6. Do not lift the range by the door handle.
Important Note to the Consumer Keep these instructions with your owner's guide for future
reference.
RTANT SAFETY
INSTRUCTIONS
Be sure your range is installed and grounded
properly by a qualified installer or service technician.
This range must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.
70--latest edition. The installation of appliances designed for
manufactured (mobile) home installation must conform with Manufactured Home Construction and Safety Standard, title 24CFR, part 3280 [Formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part 280)] or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups), ANSI Z225.1/NEPA 501A- latest edition, or with local codes.
Make sure the wall coverings around the range
can withstand the heat generated by the range.
All ranges can tip.
Injury to personscould result.
Install anti-tip devicepackedwith range.
To reduce the risk of
tipping of the range, the range must be secured by properly installed anti-tip screws, for models with coil elements. They are located in a plastic bag in the oven. For smoothtop models,
the anti-tip bracket located at the rear of the range fits under the countertop and prevents range from tipping. Failure to install the anti-tip screws will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injury might result from spilled hot liquids or from the range itself.
Before installing the range in an area covered with linoleum or any other synthetic floor covering, make sure the floor covering can
withstand heat at least 90°F above room temperature without shrinking, warping or
discoloring. Do not install the range over carpeting unless you place an insulating pad or sheet of 1/4" thick plywood between the range and carpeting.
Never leave children alone or unattended in the area where an appliance is in use. As children grow, teach them the proper, safe use of all
appliances. Never leave the oven door open when the range is unattended.
Stepping, leaning or sitting on the door of this range can result in serious injuries and
can also cause damage to the range.
Do not store items of interest to children in the
cabinets above the range. Children could be seriously burned climbing on the range to reach items.
To eliminate the risk of burns or fire by reaching
over heated surface units, cabinet storage space above the surface unit should be avoided. If
cabinet storage is to be provided the risk can be reduce by installing a range hood that project horizontally a minimum of 5 inches beyond the bottom of the
cabinet.
Do not use the oven as a storage space. This
creates a potentially hazardous situation.
Never use your range for warming or heating the
room. Prolonged use of the range without adequate ventilation can be dangerous.
Do not store or use gasoline or other flammable
vapors and liquids near this or any other appliance. Explosions or fires could result.
Reset all controls to the "off" position after using
a programmable timing operation.
FOR MODELS WITH SELF-CLEAN FEATURE:
Remove broiler pan, food and other utensils
before self-cleaning the oven. Wipe up excess spillage. Follow the precleaning instructions in the Use
and Care Guide.
ElectricaJ Requirements
This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker or fuse, having amperage as noted on the rating plate (the
rating plate is located on the oven frame).
If local codes permit, you can use a 3-wire single phase
120/208 or 120/240 Volt, 60Hz AC only electrical
system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum
wiring must be use.
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70- latest edition, and local codes and ordinances.
EJectrical Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until appliance is permanently grounded.
Disconnect power to the junction box before making the electrical connection.
This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.
Do not use a gas supply line for grounding the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
This appliance is manufactured with a neutral (white) power supply wire and a cabinet-connected green (or bare copper) grounding wire.
Connect the appliance cable to the junction box through the U.L-listed conduit connector. Complete electrical connection according to local codes and ordinances. (For preferred junction box location, see Figure 1.)
Where local codes permit connecting the cabinet- grounding conductor to the neutral (white) junction box wire (see Figure 2)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box: connect the appliance and the residence cable wires
as shown in figure 2.
Cable from
White Wire
(Neutral)
Residence
Black
WiresI
Box
Wire
(Neutral)
Green U.L.-listed (or Bare Copper) Conduit
Wire Cable from Connector
Range (or CSA listed)
Figure 2
3-Wire (Grounded Neutral) Electrical System
(Example: Junction Box)
When connecting to a 4-wire eJectricaJ system, when instaJJing in a mobiJe home, or when JocaJ codes DO NOT permit connecting the cabinet- grounding conductor to the neutraJ (white) junction box wire (see Figure 3)
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white appliance cable wires.
3. In the circuit breaker, fuse box or junction box: connect appliance and residence cable wires as shown
in figure 3.
Cable from
Green Residence (or Bare Copper)
Red_
Wires
Junction
Box
White Wire
eutral)
Range Installation
The electrical power to the range
must be shut off while line connections are being made. Failure to do so could result in serious injury
or death.
Countertop Preparation
* The cooktop sides of the range fit over the cutout edge
of your countertop.
* If you have a square finish (flat) countertop, no
countertop preparation is required. Cooktop sides lay directly on edge of countertop.
, Formed front-edged countertops must have molded
edge shaved flat 3/4" (1.9 cm) from each front corner of opening (Figure 4).
, Tile countertops may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge flattened (Fiqure 4).
Green (or Bare Copper)
Wire
Cable from Conduit
Appliance Connector
Figure 3 - 4-Wire Electrical System
(Example: Junction Box)
Improper connection of aluminum
house wiring to copper leads can result in a short circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
I"S whitewire
(or CSA listed)
NOTE TO ELECTRICIAN: The armored cable leads supplied with this appliance are UL-recognized for
connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.
31,/2,__
(81 cm)
Formed or tile countertop
trimmed %" (1.9 cm) back at
(1.9 cm) opening.
I Figure 4
If the existing cutout width is greater than 30 1116" (76,4 cm), reduce the 3A" (1.9 cm)
dimension.
For existing cutout width of 29" (73.7 cm) (Figure 5):
2 3/16" (5.56 cm) YOU must also clear
_l (s's6 crn) 2 3/16" (5.56 cm) of
11/4"
(3.2cm) _ trimmed 11A'' (3.2 cm) back at
_ ._ Formed or tile countertop
I opening.
front corners of countertop
2 3/16"
material from front
1v4"
(3.2 cm)
311/z"
(80 cm)
front corners of countertop
Figure 5
of countertop.
Loading...