iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.._
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE. C US
FOR YOUR SAFETY: Do nat stare or use gasallne or other flammable vapars
and liquids in the vicinity of this or any other appliance. LISTED
iMPORTANT iNSTALLATiON iNFORMATiON
* All electric cooktops run off a
only electrical supply with ground.
* Please note minimum distance
between cooktop and adjacent and overhead unprotected cabinetry is
30" (76.2 cm).
The corners
of this unit are fragile. Carefully install the cooktop by its sides. When installing, never let the weight of the unit rest on any one corner.
30" (76.2 cm) min. for unprotected cabinet.
24" (6t cm) min. for protected surface.
_....... .,.4
Cooktop Dimensions
30" Min. _
(76.2 cm)
4" X 8" (10.2 cmx 20.3
cm) opening at the right rear to route
Cooktop Cutout Dimensions
Figure |
30" Ceramic Model 293¼(75.6) 30 1/8 (76.5) 20 3/8 (51.8) 2034 (52.7) 6 (15.2)
All dimensions ore in inches (cm).
Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for installation of the junction box on the wall at the back of the cooktop.
Printed in China
P/N 318205431 (1311) Rev. A
English - pages 1-8
EspaSol - pages 9-16
Fran_:ais - pages 17-24
Overhead Cabinet Should Not Exceed a Maximl,m Depth of 13" (33 cm)
30" (76.2 cm) Min. Clearance Between
the Top of the Cooking
Platform and the Bottom
of an Unprotected Wood or Metal Cabinet.
24" (61 cm) Min. when
Bottom of Wood
or Metal Cabinet is
Protected by Not Less Than 1/8" Flame
Retardant Millboard Covered With Not Less Than No. 28 MGS Sheet
Steel, 0.015" (0.4 ram) Stainless Steel, 0.024';
(0.6 ram) Aluminum or
0.020'; (0.5 ram) Copper
21/2'' (6.4 cm) Min. From Edge of Cutout to Front Edge of Countertop
18"
(45.7 cm)
G
Min.
Res_ nmcmeBedtewdeen Rear Edge of
Cutout and Nearest Combustible Surface 25.4 cm)
Above Countertop
10"'
F
Approximate Location
of Junction Box
I
12 ml
(30.5 cm)
71/2'' (19.1 cm) Min. From Edge of Cooktop
to Nearest Combustible
Wall (Either Side of Unit).
It is not recommended to use drawer underneath cooktop.
Empty space is needed for installation purpose.
Letters on this figure refer to chart on front page except for I.
To eliminate the risk of burns or fire by
reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
Figure 2 - COUNTERTOP CUTOUT OPENING
2
30"' Model _ 30"' (76.2 cm) 36" Model 36" (91.4 cm)
important Notes to the installer
1. Read all instructions contained in these installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
Importanf Note to fhe Consumer
Keep these instructions with your Use and Care Guide for
future reference.
iMPORTANT SAFETY
INSTRUCTIONS
° Be sure your cooktop is installed and grounded
properly by a qualified installer or service technician.
° These cooktops must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.
70mlatest edition in the United States, or with CSA
Standard C22.1, Canadian Electrlcal Code, Part 1, in Canada.
The electrlcal power to the cooktop must
be shut off while llne connections are being made. Failure to do so could result in serious injury or death.
An extension cord must not be used with
this appliance. Such use may result in a fire, electrlcal shock, or other personal injury.
2. The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible armored cable extending from this appliance should
be connected directly to the grounded junction box. The junction box should be located as shown in
Figure 2 with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.
3. A suitable strain relief must be provided to attach the flexible armored cable to the junction box.
Observe all governing codes and local ordinances.
Unpacking Instructions
1. Leave corner supports on cooktop until completion of Electrical Connection.
2. Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily. It is important that the ceramic-glass
smoothtop be pretreated before use. See Ceramic
Glass Cooktop Cleaning and Maintenance section in the Use and Care Guide.
Provide Electrlcal Connection
Install the junction box under the cabinet and run 120/240 or 120/208 Volt, AC wire from the main
circuit panel. NOTE: DO NOT connect the wire to the circuit panel at this time. Wait until all wires have been connected in the junction box.
Electrlcal Requirements Observe all governing codes and local ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required
on a separate circuit fused on both sides of the line (a 40A time-delay fuse or circuit breaker is recommended). DO NOT fuse neutral.
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSIiNFPA No. 70- latest edition, or with CSA standard C22.1, Canadian Electrical Code, Part 1, and local local codes and