Kenmore 79032399400, 79032399401, 79032392401, 79032394401, 79032393700 Installation Guide

iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
if the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, persona[ iniury or death. FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
® Do not try to light any appliance. * Do not touch any electrical switch; do not use any phone in your building. * mmmediateIy caI[ your gas supplier from a neighbor's phone.
Follow the gas suppIier's instructions.
* mfyou cannot reach your gas supplier, caI[ the fire department.
-- mnstaiiation and service must be performed by a qualified installer, service agency or the gas supplier.
* 30" (76.2 cm) rain. for unprotected cabinet
24" (61 cra) rain. for protected surface
Gas Cooktop Dimensions
Gas Cooktop (6.4 cm) <D Cutout Dimensions , u
Figure 1
30"GasCooktop 30 (76.2) 2IY2 (54.6) 2Y2(6.4) 26Vs(67.6) I9 (48.3) 36"GasCooktop 36 (91.4) 21Y2(54.6) 2h (6.4) 323/s(82.9) 19(48.3)
30" GasCooktop 263A(67.9) 28Y2(72.4) 19% (48.4) 20 (50.8) 36" GasCooktop 3234(83.2) 337/s(86) 19% (48.4) 19Y4(48.9)
All dimensions are in inches (cm) Dimension F includes a 5" (1Z7 cm) space underneath the cooktop for connection to gas supply line
NOTE: WMng diagrams for this cooktop are enclosed in this booklet
318201458 (0410) Rev B
English - pages I=9
Espar_o[- pa'ginas 10=18
Wiring Diagram 19=20
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leavethese instructions with tile consumer.
5. Note; For operation at 2000 ft. elevations above see level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.
Important Note to the Consumer Keep these instructions with your Useand Care Guide for
future reference.
Never use your cooktop for warming or heating the room. Prolonged use of the cooktop without adequate ventilation can be hazardous.
Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance, Explosions or fires could result.
The electrical power to the cooktop
must be shut off while gas line connections are being made. Failure to do so could resutt in serious injury or death.
Before Installing the Cooktop
IMPORTANT SAFETY
NS
Installation of this cooktop must conform with local codes or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1--1atest edition in the United States, or in Canada, with the Canadian Fuel Gas Code,
CAN/CGA B14g and CAN/CGA B149.2.
This cooktop has been design certified by CSA international. As with any appliance using gas and generating heat, there are certain safety precautions you
should follow. You will find them in tile Use and Care Guide, read it carefully.
Be sure your cooktop is installed and grounded properly by a qualified installer or service
technician.
This cooktop must be electrically grounded in
accordance with local codes or, in their absence, with the Nationat Electrical Code ANSUNFPA No.
70--Jatest edition in the United States, or in Canada, with the Canadian Electrical Code, CSA
C22.1 Part 1.
The burners can be lit manually during an electrical power outage. To Hght a burner, hold a lit match to the burner head, then slowly turn the
Surface Control knob to LITE. Use caution when lighting burners manually.
Do not store items of interest to children in
cabinets above the cooktop. Children could be seriously burned climbing on the cooktop to reach
items. To eliminate the need to reach over the surface
burners, cabinet storage space above the burners shoutd be avoided,
Adjust surface burner flame size so it does not extend beyond the edge of the cooking utensil,
Excessive flame is hazardous.
8_U_D
Foam
P
Glass
Film
Figure 2
A roll of foam tape is supplied and packed in the literature package. Install the tape around tile perimeter
of the metal flange of the burner box, at a distance of
1/4" from the outer edge. Apply tile exposed adhesive
side of tile tape against the metal flange (see figure above). Remove the protective film from the
underside of the tape before inserting the cooktop into the countertop opening.
NOTE: This tape seals the underside of the cooktop to the counter. Do not remove this foam tape. This tape
prevents entry of air that may interfere with proper gas combustion, and prevents liquids from leaking under tile
cooktop.
Insert cooktop into countertop cutout so that full width of tape seals to cutout edge. NOTE; To avoid injury and
product damage, only suspend cooktop from cutout by means of cooktop metal flange. Never suspend cooktop
from cutout by means of cooktop glass edges.
13"(33cm)
Max,Depth ForCabinet
InstalledAbove Cooktop.
B
18"Min.
(45.7cm)
J
lY2" (3.8 cm)Minimum Distance Between RearEdge of Cutout
and Nearest Combustible Surface
Above Countertop.
Clearance
30" (76.2 cm) Min. Clearance
Between the
Top of the
Cooking Platform and
Unprotected
Wood or Metal
Cabinet
_To eliminate the risk of burns or fire by reaching over heated
surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (I 2.7 cm) beyond the bottom of the
cabinets.
Drawers Cannot BeUsed with This Cooktop Since Burner Box Extends
3Vs2" (8.02 cm) Below Surface of Countertop.
Figure 3 - CABINET DESIGN
Typical Gas Cooktop Installation Over
an Electric Built-in Oven Installed Under the Counter
18" (45.7 cm) Max.-----_ I
Wail
Manifold Pi
Flexible Connector
Oven Cabinet
Cabinet sides or
filler panel
-_"l m
(12,7 cm) (16,5 cm)
Flare Max Union
//I
/A
6½"
Min,
FlareUnion
120V/6OHz
Grounded
Outlet
Pressure Regulator
Manual
Shutoff
Valve
4" (10.2 cm)
Right Side of
Cabinet
(To be
accessible for shut-off valve
operation)
Typical Under Counter Installation of an Electric Built-in
Oven with a Cooktop Mounted Above
Side filler panels are necessary to isolate the unit from adjoining
cabinets. Panel height should allow
for installation of approved cooktop
models. See "Typical Gas Cooktop Installation Over an ElectricBuiltqn
Oven Installed Under the Counter" on previous page.
32" Min.** (81.3 cm)
36"
(91.4 cm)
All mounting hardware must be used to secure
the builtqn oven to tile cabinets. Refer to the builtqn oven installa- tion instructions.
208/240 Volt grounded junction
box for built-in
Junction box must
be located approx. 3" to the left of
the builtqn oven
cutout,
This cooktop may be installed over
certain builtqn elee tric oven models.
* If no cooktop is installed directly
over the oven unit, S" (12.7 cm)
maximum is allowed.
** 32" (81.3 cm) min. from top of
cabinet to top of runners must be
maintained.
Use 3/4" (1.9 cm) plywood, installed on two runners, flush with toe plate. Must be capable of supporting 150 Ibs.
Cut an opening in wood base minimum 9" (22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from left side filler panel, to route armoured (.ableto junction box.
4 I/2" (11.4 cm)
Max.*
CUTOUT DIMENSIONS (inches)
OVEN SIZE E F G
Min Max, Min Max,
30" 27¼" 28s/_" 281/2" 29" 23Y2"
(76,2cm) (69,2cm) - (727cm) (72,4cm) - (737cm) (59,7cm)
27" 27¼" 28s/_" 24V8" 25¼" 23Y2"
(68,6crn) (69,2crn) - (727cm) (63,1cm) (641cm) (59,7cm)
Wail Outlet Location
12"4
i
m 10"
Provide an Adequate Gas Supply
This cooktop isdesigned to operate on natural gas at 4" of manifold pressure only.
A pressure regulator is connected in series with the manifold on the cooktop and must remain in series with the supply line.
For proper operation, the maximum inlet pressure to the regulator must be no more than 14" of water column (W.C.) pressure.
m
m
, Recommended area for ' 120V grounded outlet
I on rear wall.
22"
NOTE: if an outlet is not available, [
have one installed by I
½
OF UNIT
Figure 4
Clamp Down Information
Once the cooktop is installed in the counter opening, you must clamp tile unit down as shown.
Foam Countertop
For checking the regulator, the inlet pressure must be at least I" (or 2.5 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" of manifold pressure, the inlet pressure must be at least 5".
Tile gas supply line to the range should be 1/2" or 3/4" pipe.
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with
natural gas.
A kit for converting to LPgas is supplied with your cooktop. The kit is marked "FOR LP/PROPANEGAS
CONVERSION".
The conversion must be performed by a qualified service technician in accordance with the kit instructions and all
local (:odes and requirements. Failure to follow instructions could result in serious injury or property
damage. The qualified agency performing this work assumes responsibility for the conversion.
Thumb
Screw
Figure 5
To (:lamp down, insert the bracket with tile offset side of the angle into the slots on each side of the unit. The thumb screw should then be run through the bracket, up against the bottom of the counter. Tighten until the unit
draws down.
Failure to make the appropriate
conversion can result in serious personal injury and property damage.