Kenmore 758154140 Owner’s Manual

SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 1
READ AND SAVE THESE INSTRUCTIONS
Operator's Manua_
®
WHOLE HOUSE HUMIDIFIER
14 Galton Output with innovative Twin Fan Technonogy Model 758.154140
follow aH its Safety Ru_es and Operating instructions.
o Safety ° Assembly o Operation
° Maintenance o Parts
° EspaSoL p. 17
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
wwwosearsocom
Part No=SP6593 Printed in Canada
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 2
_"ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER _
ff any part of this humidifier fails due to a defect in materiam or workmanship within one year from the date of purchase, or it the humidifier motor fans due to a defect in materiam or workmanship during the second year from the date
of purchase, RETURN THE HUMmDmFiER TO THE NEAREST SEARS PARTS & REPAIR CENTER, and it win be repaired free of charge. This warranty does
not incmude humidifier filters, which are e×pendabme parts that can wear out from normal use in messthan one year. This warranty gives you specific megam
rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, mL80179
GENERAL SAFETY iNSTRUCTiONS
Safety Signal Words
DANGER: means if the safety information is not followed someone wHI
be seriously injured or killed. WARNING: means if the safety
information is not followed someone toured be seriously iniured or killed.
CAUTION: means if the safety information is not followed someone may
be iniured.
1. To reduce the risk of fire or shock hazard, plug humidifier directly into a
120V, A.C. electrical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire
hazard, never put the electric cord under rugs, near heat registers,
radiators, stoves or heaters.
3. Always unplug the humidifier before moving it, before cleaning, or
whenever the humidifier is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the
6. Do not allow to be used as a toy.
7. Never use your humidifier while any
8. To reduce the risk of electrical
9. To reduce the risk of damage to
10. To reduce the risk of accidental
11. Note the warning label shown below.
WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.
humidifier.
Close attention is necessary when used by or near children.
part is missing or damaged in any manner.
hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
humidifier, unplug when not in use.
electrical shock, do not touch the cord or controls with wet hands.
Table of Contents
Water Fill .............................................. 6-7
Operating Humidifier Controls ............ 7-8
Using Your Humidifier .......................... 8@
Operating Tips for Best Performance .....9
Replacement and Care of Filters .......9-11
Cleaning and Maintenance .............. 11-12
Troubleshooting ................................... 13
Repair Parts ..................................... 14-15
q>
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 3
To Save A Service Carl
Check the following if your humidifier is not operating.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
3. Is aifflow control in operating position?
4. Is humidity control set high enough?
5. Is the cabinet sitting on a level
Know Your Humidifier --
Controms
Filter Housing
Fi_ters: Repmacement
FHter 32-14911
surface?
Pivoting Lid Removed For Clarity
Description Gailon Output/24 hrs
Capacity of Bottles Sq. Ft. Coverage
Fan Speeds Filters
Independent Bottle Gauges FilI Indicator
Auto Shut Off Auto Humidistat
Controls CUL Listed
Volts Hertz
Amps Watts
Based on an area with average insulation and an 8 foot ceiling height
ANSI/AHAM HU-ld997, SEC. 8.1
758.154140 14
2-3/8 Gallons Each
2900
3
Set of 4 (32-14911)
Yes
Yes (independent Bottle)
Yes Yes
Rotary
Yes
120 A.C.
6O
2.88 165
q>
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 4
How Your Humidifier Works
Your new Kenmore humidifier is designed to satisfy home humidity requirements through the principle of evaporation of
water in the air. After water is added to the bottle, the
filters begin to soak up the water and become totally saturated in approxi- mately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of circulation fans. As air passes through the filters, moisture is
absorbed into the air and then released in the form of vapor. No water droplets
will enter the home. AII evaporation into the air takes place in the humidifier, which means that the residue left by evaporating water is not passed into the
home, but remains in the filter.
CAUTION: Use only 32-14900 EPA Registered Bacteriostat available
from Sears Retail store. Under no circumstances should you use water
treatment products designed for Rots belt or Ultrasonic humidifiers.
CAUTION: To reduce the risk of injury, fire or damage to humidifier,
use only cleaners specifically recommended for humidifiers. Never
use flammabie, combustible or poisonous materials to clean your
humidifier. To reduce the risk of scalds and
damage to humidifier, never put hot water in humidifier.
Humidified Air is Then
Remeased Through the Top
Dry Air Enters
Through the Rear
Assembly
Your new Sears Kenmore humidifier is completely assembled for you to use.
Remove the bag pack containing two plastic caster pads from top of humidifier and retain for future use if required. See the following Step 1 for instructions.
Remove the packaging material from inside your humidifier and follow the instructions of this operator's manual for proper usage. The packaging material is located under the fan assembly. Remove the packaging material and discard.
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 5
Location Instructions
WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
Step 1: Place humidifier on a flat level surface in an area of your house where humidity is
needed most, or in an area which would likely result in moist air being circuiated
throughout the house, such as near a cold air return.
Placing the unit level is very important if the humidifier is located on carpeting. NOTE: The 14 gailon humidifier contains
water bottles. The weight of the bottles in the front of the cabinet may cause the
front casters to sink deeper into the carpet. If this happens, the water level
will be higher towards the front of the humidifier, and !ower towards the back. The water level float (located at the rear of the cabinet) may not sense the water so the filI light wilI be on and the unit wilI
not energize. If this happens, the unit will need to be Ieveied in order for the
humidifier to be energized. To level the humidifier when located on carpet, place
the included caster pads under the front two casters of the humidifier only.
NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from home thermostat and hot air registers. It is best to position humidifier
next to an inside wall. Hot air registers
and cold air from outside wails can affect the efficiencies of the controls. Unit
should not be placed where warm air from a hot air register blows directly on
unit. Moist air (humidity) produced will
disperse into the whole house, but area closest to the unit wilI have the highest humidity. If the unit is positioned close to a window, condensation may form on the window pane. If this is not appropriate the unit should be repositioned in another
location. Step 2:
The humidifier should be positioned with the back (cord exit side), at least 2 inches away from the wall. Air needs to enter through the louvers in the rear panel in order for the humidifier to operate at peak efficiency.
At Leaet 2+' Frorn WaN
Front of
,__ ..... Cabinet
t7777T/Tn_ Carpet
NOTE: If positioning on
carpet, place caster pads
// under front casters only
to level (if necessary),
Front
.... Caster
Caster Pad
Surface
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside
wail. With the humidifier in the desired location, route the electrical cord safely
so no one wilI trip or upset the humidifier. Plug in the electrical cord.
WARNING: To reduce the risk of fire
or shock hazard, humidifier should be plugged into a 120V A.C. outlet.
Do not use extension cords.
To reduce the risk of electrical shock, this humidifier has a polarized plug (one
blade is wider than the other). This plug will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 6
Water Fifl
WARNING: To reduce the risk of shock, always unplug humidifier
before cleaning or servicing. WARNING: To reduce the risk of fire
or shock hazard, do not pour or spill water into control or motor area.
If controls get wet, Iet them dry completely and have unit checked by
authorized service personnel before plugging in.
This humidifier is designed for use with the two water bottles that are located
under the pivoting lid. Open the pivoting Iid of the humidifier.
Remove the water bottles by lifting them straight up and out of the cabinet.
Notice the water bottles are designed as right and Ieft hand units. Position them in
the correct location so the humidifier can function properly. The water bottles
should rest in the front of the cabinet. Each "E-Z-FilI Side-Cap" must be facing
the rear of the unit. Each water bottle is designed with an
"E-Z-FilI Side-Cap" that is easily removable. Remove the "E-Z-FilI Side-
Cap" on the side of the water bottle by twisting counterclockwise.
Place the opening of the water bottle under a water faucet (the bottle should fit
under a four-inch clearance faucet). FilI with recommended mixture of cotd water
and Sears Bacteriostat #32-14900 (if necessary) only. Solid debris could make
the valve leak. Install the "E-Z-Fill Side-Cap" by twisting
clockwise. Hand tighten only. Check for possible leaks by
performing the following:
1. Grasp bottle handle and hold the bottle upright over a sink.
2. Press up on the valve cap plunger for about one second to let out a little
water.
3. Release the plunger.
4. Listen for air bubbles Look for leaks around the "E-Z-Fill Side-Cap".
5. If you hear air bubbles or see leaks, retighten the "E-Z-Fill Side-Cap" and
repeat Steps 1-4.
/ Fan Aesembmy
Pivoting
Lid
Bottles
"E-Z-Fill Side-Cap" Shoumd Amways Face Rear
Turn Countercmockwise
lo Remove Cap
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 7
Water Fill (continued)
Wipe off excess water from the bottle. Position the water bottle back into the
unit by grasping the water bottle handIe and lower it into the cabinet until the
bottle sits on pads at bottom of cabinet. The "E-Z-Fill Side-Cap" must be facing
the rear of the cabinet. When positioned properly, the plunger wiII open and water
will flow into the cabinet. The water leveI will automatically rema+n at approximately
1/2" until the bottles are empty.
AIIow the fiIter to saturate for 30 minutes before operation.
NOTE: Ensure that the raised section of the water bottle falIs into the hole in
stationary Iid in order for the bottle gauges to function properly.
Pivoting Lid Removed for Cmarity
Operating Humidifier Controls
The operating controIs of your Kenmore Quiet Comfort whole house humidifier are
located on the top center of the humidifier. The controls are found under
the smoked control cover, located between the air circuIating fans.
Lift the centre+ cover by @acing your finger in the round cutout and I+fting+The cover will stay open. Now you can cIearIy see the controls area. FamiIiarize yourself
with the controts and reference the diagram of the controt area for the correct
naming used in this manual
IMPORTANT: Water damage may result if condensation starts to form on windows
or walls. Humidity Control setting should be lowered until condensation no longer
forms. Speed Control: @
The unit ie adjusted from off" I " to high ",, ,,,+"with a rotary speed control. The
higher the air flow speed, the more water is evaporated and released into the air. Low speed ",," is the quietest and is provided for conditions that may not
require as high an evaporation rate.
Stationary Raised Lid Home Section
/
To Operate the Controls
Humidity Control." @ Adjust the amount of humidity depending
on your needs. The humidifier will turn on the off as required to maintain leveI of humidity seIected+ A medium setting is
recommended, but there are times when low or high amount of humidity may be
preferred. For constant operation of humidifier, rotate humidity knob aiI the way clockwise. This allows for the maximum amount of hum+dity to be evaporated into the air continuously.
VJSI+FILL Water Bottle Gauges and FiN Lights:
This humidifier is equipped with independent (left and right) water level bottle gauges. When the unit is energized
the center area of the controi panel containing the gauges and fill indicators
will illuminate red to depict the operation mode. The right bottle as viewed from the front of the humidifier wilI always empty
first. As it empties the number of red bars will decrease. When it is totally empty, the fill indicator, beside the bars, will
illuminate immediately. NOTE: The humidifier will not shut off at
this stage.
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 8
Operating Humidifier Controls (cont'd.)
Once the right bottle empties, the humidifier will begin to use the water from
the Ieft bottle until it is depleted. At this time the filI indicator beside it will
illuminate. There will still be a slight delay in the unit shutting off while it depletes
the water in the bottom of the cabinet. At this time or anytime during normal operation you may filI the water bottles to
continue operation. NOTE: A small amount of water remains in the cabinet after both filI indicators turn on and the unit shuts off.
Left Bottle Gauc
Bottle Bottle Fill Indicator Fill Indicator
Bottle
ght Gauge Back of Cabinet
Manuat Oryout: At the end of the humidification season or
if you do not plan to run the humidifier for one week or more, you can override the
automatic shutoff function to completely dry the hum[differ cabinet out.
To do this, simply slide the float retainer located at the back of the humidifier
cabinet to the top position of the slot it is located in. This will hold the float in an
upward position and the fans wilI run until you turn the power off.
NOTE: Be sure to position float retainer to the normal operating mode (lowest
position in slot) for hum[differ operation. The following diagram is of the slot the
float retainer is located in at the back of the cabinet.
Top Position ie for Manua_
Dryout Bottom Position
is for Normam
Operation Mode
\
Hoat Retainer S_ot
Using Your Humidifier
Step 1: Be sure humidifier is futl of water and
plugged in. Step 2:
Set Speed Control " _ " to lowest speed ",,".
Step 3: Set Humidity Control " _ " to medium
position. NOTE: Hum[differ should operate with
humidity control on the recommended medium setting. If it does not, the humidity is at a relatively high level
To test the unit under this condition, turn Humidity Control all the way to clockwise and unit should begin to operate. After the unit has been tested, set Humidity
Control to medium or desired level. Step 4:
if humidifier stops running and BOTH Fill indicators are not on, the humidity level is at the normal requirements for that setting or it is adjusting to the home conditions. The chart on page 9 shows recommended indoor humidity levels. The following figure shows approximate relative humidity percentages which correspond to the various settings of the Humidity Control.
q>
SP6593 Sears Kenmore 7/21/@5 2:17 PH _ge 9
Using Your Humidifier (cont'd.)
When Outdoor
Temperature is:
-IO°F O°F
10°F 20°F
Recommended Indoor
Relative Humidity is:
2O% 25% 3O%
35%
Operating Tips for Best Performance
1. Position the humidifier at least 2 inches from any wall and away from any heat
registers=
2. Do not restrict airflow from entering or exiting the humidifier=
3. Use Sears recommended bacteriostat 32-14900 to retard bacteria growth
that may cause odors and may be harmful to your health=
4= Perform regular cleaning as instructed
in "Cleaning and Maintenance" section of this manual
5= Re@ace the evaporative wicking filters
at least once per humidification season or more depending on water conditions in your area=
Replacement and Care of Filters
WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before
removing or replacing any parts.
CAUTION: To help retard bacteria growth and keep maximum efficiency,
the filter should be replaced at least once per season, or more often under hard water conditions. Use
Kenmore 32-14911 recommended replacement filter=
The filters may be rinsed periodicaily in clear water only. Take care not to damage paper. To replace evaporative wicking filters in your Kenmore Quiet Comfort Whole House humidifier, follow these
instructions=
9
SP6593 Sears Kenmore 7/21/@5 2:17 PH _ge 1@
Replacement and Care of Filters (conrd.)
1. Unplug humidifier and proceed to clean. Before removing the fiIters, we Lid
recommend moving the humidifier to Fan Assembmy an area where floor coverings are not //
susceptible to water damage, Le. kitchen or bath areas.
2. Open the pivoting lid and remove water bottles and set aside. Grasp the /
fan assembly front center and rear center. Lift off and set aside on a clean
flat surface. The filter housings are now accessible.
3.
Lift filter housing out of cabinet and
place where you may work on them comfortably. With a soft, absorbent cloth remove any remaining water or loose mineral deposits not trapped in
the filter from the humidifier cabinet.
4. To open filter housing for easy access to filters:
tTabs
/I
Spring
/\
Humidifier
/"
Filter Housing
a. Deflect the two spring tabs on top of
filter housing. Lift top cover off of the filter housing and set aside.
b. Remove the two filters and dispose
of properly. Clean internal parts of humidifier per the "Cleaning and Maintenance" section of your operator's manual.
c. Install new filters in the filter housing
track with the glue beads of the wicking pad to the inside of the filter housing.
d. Return the top cover of the filter
housing by installing cover over the fixed tabs on the rear of the lower
filter housing and pivoting the cover down over the top of the filters. Snap the cover over the two spring
tabs.
e. Replace the filter housing in the
cabinet.
Spring Tabs
Front of
Humidifier
!
Fixed Tabs
Filter
zHousing
/
Rear of
Humidifier
Top
/ Cover
Spring
10 Tabs
Loading...
+ 22 hidden pages