Kenmore 758.154140 Owner's Manual

SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 1
READ AND SAVE THESE INSTRUCTIONS
Operator's Manua_
®
WHOLE HOUSE HUMIDIFIER
14 Galton Output with innovative Twin Fan Technonogy Model 758.154140
follow aH its Safety Ru_es and Operating instructions.
o Safety ° Assembly o Operation
° Maintenance o Parts
° EspaSoL p. 17
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
wwwosearsocom
Part No=SP6593 Printed in Canada
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 2
_"ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER _
ff any part of this humidifier fails due to a defect in materiam or workmanship within one year from the date of purchase, or it the humidifier motor fans due to a defect in materiam or workmanship during the second year from the date
of purchase, RETURN THE HUMmDmFiER TO THE NEAREST SEARS PARTS & REPAIR CENTER, and it win be repaired free of charge. This warranty does
not incmude humidifier filters, which are e×pendabme parts that can wear out from normal use in messthan one year. This warranty gives you specific megam
rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, mL80179
GENERAL SAFETY iNSTRUCTiONS
Safety Signal Words
DANGER: means if the safety information is not followed someone wHI
be seriously injured or killed. WARNING: means if the safety
information is not followed someone toured be seriously iniured or killed.
CAUTION: means if the safety information is not followed someone may
be iniured.
1. To reduce the risk of fire or shock hazard, plug humidifier directly into a
120V, A.C. electrical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire
hazard, never put the electric cord under rugs, near heat registers,
radiators, stoves or heaters.
3. Always unplug the humidifier before moving it, before cleaning, or
whenever the humidifier is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the
6. Do not allow to be used as a toy.
7. Never use your humidifier while any
8. To reduce the risk of electrical
9. To reduce the risk of damage to
10. To reduce the risk of accidental
11. Note the warning label shown below.
WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.
humidifier.
Close attention is necessary when used by or near children.
part is missing or damaged in any manner.
hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
humidifier, unplug when not in use.
electrical shock, do not touch the cord or controls with wet hands.
Table of Contents
Water Fill .............................................. 6-7
Operating Humidifier Controls ............ 7-8
Using Your Humidifier .......................... 8@
Operating Tips for Best Performance .....9
Replacement and Care of Filters .......9-11
Cleaning and Maintenance .............. 11-12
Troubleshooting ................................... 13
Repair Parts ..................................... 14-15
q>
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 3
To Save A Service Carl
Check the following if your humidifier is not operating.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
3. Is aifflow control in operating position?
4. Is humidity control set high enough?
5. Is the cabinet sitting on a level
Know Your Humidifier --
Controms
Filter Housing
Fi_ters: Repmacement
FHter 32-14911
surface?
Pivoting Lid Removed For Clarity
Description Gailon Output/24 hrs
Capacity of Bottles Sq. Ft. Coverage
Fan Speeds Filters
Independent Bottle Gauges FilI Indicator
Auto Shut Off Auto Humidistat
Controls CUL Listed
Volts Hertz
Amps Watts
Based on an area with average insulation and an 8 foot ceiling height
ANSI/AHAM HU-ld997, SEC. 8.1
758.154140 14
2-3/8 Gallons Each
2900
3
Set of 4 (32-14911)
Yes
Yes (independent Bottle)
Yes Yes
Rotary
Yes
120 A.C.
6O
2.88 165
q>
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 4
How Your Humidifier Works
Your new Kenmore humidifier is designed to satisfy home humidity requirements through the principle of evaporation of
water in the air. After water is added to the bottle, the
filters begin to soak up the water and become totally saturated in approxi- mately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of circulation fans. As air passes through the filters, moisture is
absorbed into the air and then released in the form of vapor. No water droplets
will enter the home. AII evaporation into the air takes place in the humidifier, which means that the residue left by evaporating water is not passed into the
home, but remains in the filter.
CAUTION: Use only 32-14900 EPA Registered Bacteriostat available
from Sears Retail store. Under no circumstances should you use water
treatment products designed for Rots belt or Ultrasonic humidifiers.
CAUTION: To reduce the risk of injury, fire or damage to humidifier,
use only cleaners specifically recommended for humidifiers. Never
use flammabie, combustible or poisonous materials to clean your
humidifier. To reduce the risk of scalds and
damage to humidifier, never put hot water in humidifier.
Humidified Air is Then
Remeased Through the Top
Dry Air Enters
Through the Rear
Assembly
Your new Sears Kenmore humidifier is completely assembled for you to use.
Remove the bag pack containing two plastic caster pads from top of humidifier and retain for future use if required. See the following Step 1 for instructions.
Remove the packaging material from inside your humidifier and follow the instructions of this operator's manual for proper usage. The packaging material is located under the fan assembly. Remove the packaging material and discard.
SP6593 Sears Kenmore 7/21/@5 2:16 PH _ge 5
Location Instructions
WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
Step 1: Place humidifier on a flat level surface in an area of your house where humidity is
needed most, or in an area which would likely result in moist air being circuiated
throughout the house, such as near a cold air return.
Placing the unit level is very important if the humidifier is located on carpeting. NOTE: The 14 gailon humidifier contains
water bottles. The weight of the bottles in the front of the cabinet may cause the
front casters to sink deeper into the carpet. If this happens, the water level
will be higher towards the front of the humidifier, and !ower towards the back. The water level float (located at the rear of the cabinet) may not sense the water so the filI light wilI be on and the unit wilI
not energize. If this happens, the unit will need to be Ieveied in order for the
humidifier to be energized. To level the humidifier when located on carpet, place
the included caster pads under the front two casters of the humidifier only.
NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from home thermostat and hot air registers. It is best to position humidifier
next to an inside wall. Hot air registers
and cold air from outside wails can affect the efficiencies of the controls. Unit
should not be placed where warm air from a hot air register blows directly on
unit. Moist air (humidity) produced will
disperse into the whole house, but area closest to the unit wilI have the highest humidity. If the unit is positioned close to a window, condensation may form on the window pane. If this is not appropriate the unit should be repositioned in another
location. Step 2:
The humidifier should be positioned with the back (cord exit side), at least 2 inches away from the wall. Air needs to enter through the louvers in the rear panel in order for the humidifier to operate at peak efficiency.
At Leaet 2+' Frorn WaN
Front of
,__ ..... Cabinet
t7777T/Tn_ Carpet
NOTE: If positioning on
carpet, place caster pads
// under front casters only
to level (if necessary),
Front
.... Caster
Caster Pad
Surface
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside
wail. With the humidifier in the desired location, route the electrical cord safely
so no one wilI trip or upset the humidifier. Plug in the electrical cord.
WARNING: To reduce the risk of fire
or shock hazard, humidifier should be plugged into a 120V A.C. outlet.
Do not use extension cords.
To reduce the risk of electrical shock, this humidifier has a polarized plug (one
blade is wider than the other). This plug will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
Loading...