FULL ONE YEAR WARRANTY ON HUMIDIFIER
if within one (1) year from the date of purchase, this humidifier fails due to
a defect in material or workmanship, Sears will repair it, free of charge. If
within two (2) years from the date of purchase, the motor fails due to
defect in material or workmanship, Sears will repair it free of charge.
This warranty service is available by simply returning the humidifier to the
nearest Sears Service Center/Department throughout the United States.
This warranty applies only while this product is used in the United States.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
Sears, Roebuck and Co., D/817 WA, Hoffman Estates, IL 60179
GEN RAL SAFETY INSTRUCTIONS
Safety Signal Words 4. Keep the humidifier clean.
DANGER: means if the safety information
is not followed someone will be seriously
injured or killed.
WARNING: means if the safety informa-
tion is not followed someone could be
seriously injured or killed.
CAUTION: means if the safety informa-
tion is not followed someone might be
seriously injured.
1. To avoid fire or shock hazard, plug
humidifier directly into a 120V, A.C. elec-
trical outlet. Do not use extension cords.
2. Keep the electric cord outof traffic
areas. To avoid fire hazard, never put
the electric cord under rugs, near heat
registers, radiators, stoves or heaters.
3. Always unplug the humidifier before
moving it, removing the housing sec-
tion, before cleaning, or whenever the
humidifier is not in service.
5. Do not put foreign objects inside the
humidifier.
6. Never use your humidifier while any part
is missing or damaged in any manner.
7. To avoid electrical hazard or damage
to humidifier, do not tilt, jolt or tip
humidifier while unit is running.
8. To avoid damage to humidifier, unplug
humidifier, when water reservoirs are
empty or when the humidifier is not in
use.
9. To avoid accidental electrical shock,
do not touch the cord or controls with
wet hands.
10.
Note the warning label shown below
and on the humidifier.
WARNING: Toreduce the risk of fire,
electric shock, or injury always unplug
before filling, servicing or cleaning.
J
Table of Contents
Warranty Information ............................. 2
General Safety Instructions ................... 2
To Save a Service Call .......................... 2
Know Your Humidifier ............................. 3
Humidifier Operations ............................ 4
Location Instructions .......................... 4-5
Electrical Hook-Up ................................. 5
i
Water Fill. ........................................... 5-6
Operating Humidifier Controls ............... 7
Using Your Humidifier ........................... 8
Care of Filter ............ "..... i.................. 9-10
Cleaning Your Humidifier .............. 11-12
Trouble Shooting ................................. 13
Repair Parts ................................... 14-15
To Save a Service Carl ........
Check following if your humidifier will not
operate.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
3. Is airflow control in operating position?
4. Is humidity control set high enough?
5. Is the cabinet setting on a level surface?
III_ i i f II

Know Your Humidifier
I ii ii I I ii
Filter
Support
Assembly
Filters
Controls
Fill Light
Operating Light
Bottles
Description 758.144530
Gallon Output/24 Hrs.
Capacity Tanks or Bottles
Sq. Ft. Coverage
Run Time
Fan Speeds
Filters
Fill Light
Water Level Indicator
Auto Humidistat
Auto Shut Off
Controls
Operating Light
U.L. Listed
AHAM Certified
Volts
Hertz
Amps
Watts
Control Panel Cover & Pivoting Lid
Removed for Clarity
13
2 Bottles
3000
48 Hours
Variable
4
Yes
Yes
Yes
Yes
Slide Adj.
Yes
Yes
Yes
120 A.C.
60
2.88
165

Humidifier Operations
Your new Sears humidifier is designed to
satisfy home humidity requirements
through the principle of evaporation of
water into the air.
After water is added to the tank or bottles,
the filters begin to soak up the water and
become totally saturated in approximately
30 minutes. Air is drawn in from the rear
of the humidifier, then passes through the
filters by means of two circulation fans. As
air passes through the filters, moisture is
absorbed into the air and then released
through the top of the humidifier. This
moist air is released in the form of vapor.
No water droplets wilt enter the home. All
evaporation into the air takes place in the
humidifier, which means that the residue
left by evaporating water is not passed
into the home, but remains in the filter.
CAUTION: Use only 32-14900 EPA
Registered Bacteriostat available
from SEARS Retail store. Under no
circumstances should you use water
treatment products designed for
Roto belt or Ultrasonic humidifiers.
illllllllllllll ii i iiiiiiiiiiiiiiiiiiiii i
Humidified Air is
Then Released
Through the Top
Dry Air Enters :.V-.kk'--kVV
Through the i
Rear !
!i
CAUTION: Keep your humidifier
clean. While humidifiers do not
cause colds, some studies suggest
that dirty humidifiers can cause cold-
like symptoms in some people. To
avoid this, we recommend you clean
your humidifier weekly with Humidi-
fier Cleaner 32-14713 and use Bacte-
riostat 32-14900. These are available
at your local Sears store.
/
Your new Sears Kenmore humidifier is
completely assembled for you to use.
Remove the packaging material from
inside your humidifier and follow the
,,,,,,,,..........,, ,, ,
Location Instructions
WARNING: For your own safety, do
not use humidifier if any parts are
damaged or missing.
Step 1
Place humidifier on a flat level surface in
area of house where most humidity is
needed, or one which would likely result
in moist air being circulated throughout
the house such as near a cold air return.
Placing the unit level is very important if
the humidifier is located on carpeting.
NOTE: The 13 gallon humidifier contains
water bottles, the weight of the bottles in
the front of the cabinet may sink the cast-
ers deeper in the carpet. This will keep
the water level forward in the cabinet. The
water level float (located at the rear of the
I lille III I IIII I I II IIIIIIIIIIIII
instructions of this owner's manual for
proper usage. The packaging material is
located under the fan assembly. Remove
the packaging material and discard.
cabinet) may not sense the water and the
fill light will be on and the unit will not
energize, if this happens, the unit will
need to be leveled in order for the humidi-
fier to be energized.
NOTE: It may be necessary to purchase
leveling coasters from your local hard-
ware store. The coasters should be posi-
tioned under the front two casters of the
humidifier.
Moist air (humidity) produced will disperse
into the whole house, but area closest to
unit will have the highest humidity. If the
unit is positioned close to a window, con-
densation may form on the window pane.
If this is not appropriate the unit should be
repositioned in another location.

Location Instructions (continued) ,,,,
NOTE: Due to release of cool, moist air
from humidifier, it is best to direct air away
from home thermostat and hot air regis-
ters. It is best to position humidifier next to
an inside wall. Hot air registers and cold
air from outside walls can affect the effi-
ciencies of the controls. Unit should not
be placed where warm air from a hot air
register blows directly on unit.
Step 2
The humidifier should be positioned with
the back (cord exit side), at least 2 inches
away from the wall. Air needs to enter
through louvers in the rear panel in order
for the humidifier to operate at peak effi-
ciency.
At Least
2" From Wall
i , ,,,t
°' t
I i i iiIIiii i
Electrical Hook-Up ....
Locate nearest 120V A.C. wall socket in
the location desired, preferably on inside
wail. Plug in the electrical cord.
WARNING: To avoid fire or shock
hazard, humidifier should be
plugged into a 120V A.C. outlet. Do
not use extension cords.
Water Fill ....
WARNING: To avoid shock, always
unplug humidifier before filling,
cleaning, or servicing.
WARNING: To avoid fire or shock
hazard, do not pour or spill water
into control or motor area. Close the
control cover. If controls get wet, let
them dry completely and have unit
checked by authorized service per-
sonnel before plugging in.
j iiiiiiiiiiiiiiiiiiiiiiiiiiii i iiiil!llllllllllllllll ii
Pivoting Lid Removed for Clarity
This humidifier is designed to be used
with the two water bottles that are located
under the pivoting lid.
Open the pivoting lid of the humidifier.
Remove the water bottles, lift them
straight up and out of the cabinet.
5