READ AND SAVE THESE INSTRUCTIONS
Operator's Manual
®
WHOLE HOUSE HUMIDIFIER
12 Gallon Output with
Innovative Twin Fan Technology
Model 758.144162
CAUTION: Before using this
product, read this manual and
follow all its Safety Rules and
Operating Instructions.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com
Part No. SP6595 Printed in U.S.A.
• Safety
• Assembly
• Operation
• Maintenance
• Parts
• Espahol, p. 17
ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER
If any part of this humidifier fails due to a defect in material or workmanship
within one year from the date of purchase, or it the humidifier motor fails due
to a defect in material or workmanship during the second year from the date
of purchase, RETURN THE HUMIDIFIER TO THE NEAREST SEARS PARTS &
REPAIR CENTER, and it will be repaired free of charge. This warranty does
not include humidifier filters, which are expendable parts that can wear out
from normal use in less than one year. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
Sears Roebuck and Co. Dept. 817WA, Hoffman Estates IL 60179
GENERAL SAFETY INSTRUCTIONS
Safety Signal Words
DANGER: means if the safety
information is not followed someone will
be seriously injured or killed.
WARNING: means if the safety
information is not followed someone
could be seriously injured or killed.
CAUTION: means if the safety
information is not followed someone may
be injured.
1. To reduce the risk of fire or shock
hazard, plug humidifier directly into a
120V, A.C. electrical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic
areas. To reduce the risk of fire
hazard, never put the electric cord
under rugs, near heat registers,
radiators, stoves or heaters.
3. Always unplug the humidifier before
moving it, before cleaning, or
whenever the humidifier is not in
service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the
humidifier.
6. Do not allow to be used as a toy.
Close attention is necessary when
used by or near children.
7. Never use your humidifier while any
part is missing or damaged in any
manner.
8. To reduce the risk of electrical
hazard or damage to humidifier, do
not tilt, jolt or tip humidifier while unit
is running.
9. To reduce the risk of damage to
humidifier, unplug when not in use.
10. To reduce the risk of accidental
electrical shock, do not touch the
cord or controls with wet hands.
11. Note the warning label shown below.
WARNING: To reduce risk of fire,
electric shock, or injury always unplug
before servicing or cleaning.
Table of Contents
Warranty Information ............................... 2
General Safety Instructions .................... 2
To Save A Service Call ........................... 3
Know Your Humidifier ............................. 3
How Your Humidifier Works .................... 4
Assembly ................................................ 4
Location Instructions .............................. 5
Electrical Hook-Up .................................. 5
Water Fill ................................................. 6
Operating Humidifier Controls ............... 7
Using Your Humidifier ............................. 8
Operating Tips for Best Performance .....8
Replacement and Care of Filters ....... 9-10
Cleaning and Maintenance .............. 11-12
Troubleshooting ................................... 13
Repair Parts ..................................... 14-15
To Save A Service Call
Check the following if your humidifier is
not operating.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
Know Your Humidifier
3. Is airflow control in operating position?
4. Is humidity control set high enough?
5. Is there enough water in the humidifier
cabinet?
Filter
Housing...
Filters:
Replacement
Filter 32-14912
Controls_
Description
Gallon Output/24 hrs
Capacity of Bottles
Sq. Ft. Coverage
Fan Speeds
Filters
Water Level Indicator
Fill Indicator
Auto Shut Off
Auto Humidistat
Controls
ETL Listed
Volts
Hertz
Amps
Watts
j Fan Assembly
Splash Guard
Pivoting Lid
Pivoting Lid Removed For Clarity
758.144162
12
4.75 Gallons
2500
3
4 Pack(32-14912)
Yes
Yes
Yes
Yes
Rotary
Yes
120 A.C.
6O
2.28
130
Based on an area with average insulation and an 8 foot
ceiling height.
How Your Humidifier Works
Your new Kenmore humidifier is designed
to satisfy home humidity requirements
through the principle of evaporation of
water in the air.
After water is added to the bottle, the
filters begin to soak up the water and
become totally saturated in approxi-
mately 30 minutes. Air is drawn in from
the rear of the humidifier and through the
filters by means of circulation fans. As air
passes through the filters, moisture is
absorbed into the air and then released
in the form of vapor. No water droplets
wilt enter the home. All evaporation into
the air takes place in the humidifier,
which means that the residue left by
evaporating water is not passed into the
home, but remains in the filter.
CAUTION: Use only 32-14900 EPA
Registered Bacteriostat available
from Sears Retail store. Under no
circumstances should you use water
treatment products designed for
Roto belt or Ultrasonic humidifiers.
Enters
Dry Air _i!
Through
the Rear '
CAUTION: Keep your humidifier
clean. While humidifiers do not cause
colds, some studies suggest that dirty
humidifier can cause cold-like
symptoms in some people. To reduce
the risk of this, we recommend you
clean your humidifier weekly with
Humidifier Cleaner 32-14713 and use
Bacteriostat 32-14900. These are
available at your local Sears store.
Humidified Air is Then
Released Through the Top
i II
I
Assembly
Your new Sears Kenmore humidifier is
completely assembled for you to use.
Remove the packaging material from
inside your humidifier and follow the
instructions of this operatorlt manual for
proper usage. The packaging material is
located under the fan assembly. Remove
the packaging material and discard.
NOTE: The filters may have shifted
during shipping. Ensure that they are
properly seated in the bottom of the
cabinet below the top filter housings
before filling. Refer to "Replacement and
Care of Filters" section on page 9.
Location Instructions
WARNING: For your own safety, do I
not use humidifier if any parts are
damaged or missing.
Step 1:
Place humidifier on a fiat level surface in
an area of your house where humidity is
needed most, or in an area which would
likely result in moist air being circulated
throughout the house, such as near a
cold air return.
Placing the unit level is very important if
the humidifier is located on carpeting.
Moist air (humidity) produced wilt
disperse into the whole house, but area
closest to the unit wilt have the highest
humidity. If the unit is positioned close to
a window, condensation may form on the
window pane. If this is not appropriate
the unit should be repositioned in another
location.
NOTE: Due to release of cool, moist air
from humidifier, it is best to direct air
away from home thermostat and hot air
I
registers. It is best to position humidifier
next to an inside wall. Hot air registers
and cold air from outside walls can affect
the efficiencies of the controls. Unit
should not be placed where warm air
from a hot air register blows directly on
unit.
Step 2:
The humidifier should be positioned with
the back (cord exit side), at least 2
inches away from the walt. Air needs to
enter through the louvers in the rear
panel in order for the humidifier to
operate at peak efficiency.
At Least 2" From Wall
Electrical Hook-Up
Locate nearest 120V A.C. walt socket in
the location desired, preferably on inside
walt. With the humidifier in the desired
location, route the electrical cord safely
so no one will trip or upset the humidifier.
Plug in the electrical cord.
WARNING: To reduce the risk of fire
or shock hazard, humidifier should
be plugged into a 120VA.C. outlet.
Do not use extension cords.
To reduce the risk of electrical shock, this
humidifier has a polarized plug (one
blade is wider than the other). This plug
will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet,
reverse plug. If it still does not fit, contact
a qualified electrician to install the proper
outlet. Do not change the plug in any way.
Water Fill
WARNING: To reduce the risk of
shock, always unplug humidifier
before cleaning or servicing.
WARNING: To reduce the risk of fire
or shock hazard, do not pour or spill
water into control or motor area.
If controls get wet, let them dry
completely and have unit checked by
authorized service personnel before
plugging in.
This humidifier is designed to be filled
using a bucket fill method. The unit
should be positioned where it will be
operating. To fill the humidifier, close the
control cover and open the pivoting lid.
Notice the splash guard inside the
cabinet of the humidifier.
Use recommended mixture of cold water
and if necessary Sears Bacteriostat #32-
14900 only. Pour the water slowly from a
bucket into the cabinet onto the center of
splash guard.
NOTE: Deflect water off center of splash
guard when filling. The water deflects off
the splash guard and drops into the
bottom of the cabinet. Do not pour water
onto top of unit or control area.
Standing in front of the humidifier, notice
the "FULL" labels positioned to the left
and right at the bottom inside of the
cabinet. These labels indicate the
maximum amount of water that can be
poured into the humidifier.
Do not fill water in the cabinet above
this line. If you do, water will leak out
of the cabinet and onto the floor.
Pivoting Lid
Cabinet_
Front of Humidifier
Operating Humidifier Controls
The operating controls of your Kenmore
Quiet Comfort whole house humidifier are
located on the top center of the
humidifier. The controls are found under
the smoked control cover, located
between the air circulating fans.
Lift the control cover by placing your
finger in the round cutout and lifting. The
cover will stay open. Now you can clearly
see the controls area. Familiarize yourself
with the controls and reference the
diagram of the control area for the correct
naming used in this manual.
To Operate the Controls
Humidity Control: O
Adjust the amount of humidity depending
on your needs. The humidifier wilt turn on
the off as required to maintain level of
humidity selected. A medium setting is
recommended, but there are times when
low or high amount of humidity may be
preferred. For constant operation of
humidifier, rotate humidity knob all the
way clockwise. This allows for the
maximum amount of humidity to be
evaporated into the air continuously.
IMPORTANT: Water damage may result
if condensation starts to form on windows
or walls. Humidity Control setting should
be lowered until condensation no longer
forms.
Speed Control: O
Your Kenmore humidifier has a three
speed rotary fan control. The higher the
air flow speed, the more water is
evaporated and released into the air.
Low speed "." is the quietest and is
provided for conditions that may not
require as high an evaporation rate.
Water Level Indicator:
This humidifier is equipped with a water
level gauge located in the center of the
control panel. When the cabinet is full of
water the large window opposite the
scale wilt show green. As water is
depleted the amount of green will
decrease to correspond with the scale.
Fill Indicator:
When the unit has a small amount of
water left in it, the small window next to
Fill on the control panel wilt appear
orange and the unit will automatically
shut off.
NOTE: The cabinet may have a small
amount of water in it once unit shuts off.
Manual Dryout:
At the end of the humidification season or
if you do not plan to run the humidifier for
one week or more, you can override the
automatic shutoff function to completely
dry the humidifier cabinet out.
To do this, simply slide the float retainer
located at the back of the humidifier
cabinet to the top position of the slot it is
located in. This wilt hold the float in an
upward position and the fans will run until
you turn the power off.
NOTE: Be sure to position float retainer
to the normal operating mode (lowest
position in slot) for humidifier operation.
The following diagram is of the slot the
float retainer is located in at the back of
the cabinet.
Back of Cabinet is for Manual
_ Dryout
Indicator
Top Position
Bottom Position
is for Normal
Operation Mode
Link Arm
Assembly
Retainer Slot
Using Your Humidifier
Step 1:
Be sure humidifier is full of water and
plugged in.
Step 2:
Set Speed Control " I_ " to lowest
speed ".".
Step 3:
Set Humidity Control " _ " to medium
position.
NOTE: Humidifier should operate with
humidity control on the recommended
medium setting. If it does not, the
humidity is at a relatively high level.
To test the unit under this condition, turn
Humidity Control all the way to clockwise
and unit should begin to operate. After
the unit has been tested, set Humidity
Control to medium or desired level.
Allow 24 hours for humidifier to adjust.
If humidity level in home is sufficient, the
humidifier will only operate with Humidity
Control turned all the way clockwise.
IMPORTANT: Water damage may result
if condensation starts to form on windows
or walls. Humidity Control setting should
be lowered until condensation no longer
forms.
Step 4:
If humidifier stops running and the unit is
not empty, the humidity level is at the
normal requirements for that setting or it
is adjusting to the home conditions. The
table below shows recommended indoor
humidity levels. The figure shows
approximate relative humidity
percentages which correspond to the
various settings of the Humidity Control.
When Outdoor
Temperature is:
-10°F
0°F
10°F
20°F
Recommended Indoor
Relative Humidity is:
20%
25%
30%
35%
ReZ,!,
'-)
_a
Operating Tips for Best Performance
1. Position the humidifier at least 2 inches
from any wall and away from any heat
registers.
2. Do not restrict airflow from entering or
exiting the humidifier.
3. Use Sears recommended bacteriostat
32-14900 to retard bacteria growth
that may cause odors and may be
harmful to your health.
4. Perform regular cleaning as instructed
in "Cleaning and Maintenance" section
of this manual.
5. Replace the evaporative wicking filters
at least once per humidification
season or more depending on water
conditions in your area.
Replacement and Care of Filters
WARNING: To reduce the risk of
shock or injury from moving parts,
always unplug humidifier before
removing or replacing any parts.
CAUTION: To help retard bacteria
growth and keep maximum efficiency,
the filter should be replaced at least
once per season, or more often
under hard water conditions. Use
Kenmore 32-14912 recommended
replacement filter.
All filters may be rinsed periodically in
clear water only. Take care not to damage
paper. To replace evaporative wicking
filters in your Kenmore Quiet Comfort
Whole House humidifier, follow these
instructions.
1. Unplug humidifier and proceed to
clean. Before removing the filters, we
recommend moving the humidifier to
an area where floor coverings are not
susceptible to water damage, i.e.
kitchen or bath areas.
2. To remove parts: Remove the fan
assembly by opening the pivoting lid.
Grasp the fan assembly front center
and rear center. Lift off and set aside
on a clean flat surface. The filter
housings are now accessible.
NOTE: There are two filter housing
assemblies. Each assembly consists of
a top filter housing and a front filter
housing. The front filter housing contains
tabs that secure the top filter housing.
Do not remove the front filter housings.
3. To remove top filter housing, deflect
the two vertical tabs on top of front
filter housing and lift up and out of
cabinet. With a soft, absorbent cloth
remove any remaining water or loose
mineral deposits not trapped in the
filter from the filter housing
assemblies.
4. Remove the two filters and dispose of
properly. Repeat for other top filter
housing. Clean internal parts of
humidifier per the'Cleaning and
Maintenance" section of this operatorl_
manual.
\
Tab on Front
Filter Housing
LinkArm
Assembh
Retainer
Exploded View of Float Assembly
Lid
Fan Assembly
/
/
Humidifier
/
Top Filter Link Arm
Housings Assembly
Front of Humidifier
(Top View)
,......................Retainer
/
Float
Assembly
Float Pivot
/ Arm
/
Float
/
Replacement and Care of Filters (cont'd.)
5. a. Install new filter (32-14912)in the
bottom of the cabinet.
NOTE: The new filters wilt only fit into the
cabinet one way. Take note of the inner
cabinet detail where the filters sit. Each
pair of filters must be positioned so the
glue beads face out from each other.
Refer to Figure 5a.
b. Place the filters into the bottom of
the cabinet so the open pleats slip
over the tabs in the bottom of the
cabinet. Repeat for other side.
c. Reposition top filter housings on top
of filters and snap into front filter
housings.
d. Position fan assembly onto the
cabinet. Make sure the fan venturi
(lowest cylinder section below the
fan) is placed inside the top filter
housings.
e. Close the pivoting lid on the fan
assembly.
f. The unit is ready for use or to be
stored away for next season.
Front Filter Housing
Front of Humidifier
Figure 5a - Filter Locations Marked X
Top Filter Link Arm
Housings Assembly
Tab on Front
Filter Housing
Front of Humidifier
(Top View)
......................Retainer
/
Float
Assembly
10