Kenmore 758144108 Owner’s Manual

READ AND SAVE THESE mNSTRUCTmONS
Operator's Manua_
WHOLE HOUSE
10 Gallon Output Model 758.144108
CAUTION: Before using this product, read this manua_ and follow aH its Safety Rumes and Operating instructions.
o Safety o Assembmy o Operation
o Maintenance
o Parts o EspaSom, p. 17
Sears, Roebuck and Co., Hoffman Estates, mL60179 U.S.A.
wwwosearsocom
Part No. SP6594 Printed in Canada
_"ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER _
ff any part of this humidifier fails due to a defect in materiam or workmanship within one year from the date of purchase, or it the humidifier motor falls due to a defect in materiam or workmanship during the second year from the date
of purchase, RETURN THE HUMmDmFiER TO THE NEAREST SEARS PARTS & REPAIR CENTER, and it will be repaired free of charge. This warranty does
not incmude humidifier filters, which are e×pendabme parts that can wear out from normal use in messthan one year. This warranty gives you specific megam
rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, mL80179 ,_
GENERAL SAFETY iNSTRUCTiONS
Safety Signal Words
DANGER: means if the safety information is not followed someone wHI
be seriously injured or killed. WARNING: means if the safety
information is not followed someone toured be seriously iniured or killed.
CAUTION: means if the safety information is not followed someone may
be iniured.
1. To reduce the risk of fire or shock hazard, plug humidifier directly into a
120V, A.C. electrical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire
hazard, never put the electric cord under rugs, near heat registers,
radiators, stoves or heaters.
3. Always unplug the humidifier before moving it, before cleaning, or
whenever the humidifier is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the humidifier.
6. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
7. Never use your humidifier while any part is missing or damaged in any
manner.
8. To reduce the risk of electrical hazard or damage to humidifier, do
not tilt, jolt or tip humidifier while unit is running.
9. To reduce the risk of damage to humidifier, unplug when not in use.
10. To reduce the risk of accidental electrical shock, do not touch the
cord or controis with wet hands.
11. Note the warning label shown below.
WARNING: To reduce risk of fire, electric shock, or iniury always unplug before servicing or cleaning.
Table of Contents
Water Fill .............................................. 6-7
Operating Humidifier Controls ............... 7
Using Your Humidifier ............................. 8
Operating Tips for Best Performance .....8
Replacement and Care of Filters .......9-10
Cleaning and Maintenance .............. 11-12
Troubleshooting ................................... 13
Repair Parts ..................................... 14-15
To Save A Service Caff
Check the following if your humidifier is not operating.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
Know Your Humidifier --
3. Is aidlow control in operating position?
4. Is humidity control set high enough?
5. Is the cabinet sitting on a level surface?
Fan Assembmy ............
Housing .....
AesemMy ............
Humidit! Controm
Description Gallon Output/24 hrs
Capacity of Bottle Capacity of Base
Sq. Ft. Coverage Fan Speeds Auto Fan Speed Replacement Filter
Power Light Fill Light
Auto Humidistat Auto Shut Off Controls
CUL Listed Volts Hertz
Amps (High Speed) Watts (High Speed)
Bottme Handme
Speed Control
.........Bottme
Base
Fi_ter: Replacement No.
32-14908
758.144108 10
1.9 Gallons
2.0 Gallons 2100
3
Yes
32-14906
Yes Yes
Yes Yes
Rotary
Yes
120 A.C.
60
0.80 8O
Based on an area with average insulation and an 8 foot ceiling height
How Your Humidifier Works
Your new Kenmore humidifier is designed to satisfy home humidity requirements through the principle of evaporation of
water in the air. After water is added to the bottle, the
filters begin to soak up the water and become totally saturated in approxi- mately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of circulation fans. As air passes through the filters, moisture is
absorbed into the air and then released in the form of vapor. No water droplets
will enter the home. AII evaporation into the air takes place in the humidifier, which means that the residue left by evaporating water is not passed into the
home, but remains in the filter. This natural process of evaporation helps
eliminate the change of white dust in the humidified output air.
CAUTION: Use only 32-14900 EPA Registered Bacteriostat available
from Sears Retail store. Under no circumstances should you use water
treatment products designed for Rote belt or Ultrasonic humidifiers.
Humidified air is then reteased
throug
Dry air
enters through
the
Jouvers
in the
housing
CAUTION: To reduce the risk of iniury, fire or damage to humidifier,
use only cleaners specifically recommended for humidifiers. Never
use flammable, combustible or poisonous materials to clean your
humidifier. To reduce the risk of scalds and damage to humidifier,
never put hot water in humidifier.
Assembly
Carefully remove the humidifier and all other contents from the carton.
There is a black strip that contains six pads for the bottom of the humidifier.
Remove each pad and place one on each of the six legs on the bottom of the base as shown, by the solid dots.
Once installed return the humidifier to it's originaI state and proceed to "Location
instructions".
Location Instructions
WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
Step 1 : Place humidifier on a flat level surface in
an area of your house where humidity is needed most, or in an area which would
likely result in moist air being circulated throughout the house, such as near a
cold air return. Placing the unit level is very important.
Special attention should be given to unit's level if the humidifier is located on
carpeting. Moist air (humidity) produced will
disperse into the whole house, but the area closest to the unit wilI have the
highest humidity. If the unit is positioned close to a window, condensation may
form on the window pane. If this is not appropriate the unit should be
repositioned in another location. NOTE: Due to release of cool, moist air
from humidifier, it is best to direct air away from thermostat and hot air
registers. It is best to position humidifier next to an inside wall. Hot air registers
and cold air from outside walls can affect the efficiencies of the controls. Unit
should not be placed where warm air from a hot air register blows directly on
unit. Step 2:
The humidifier should be positioned with the back (cord exit side) and left side, at least 2 inches away from the wall. Air needs to enter through alI of the louvers in the housing assembly in order for the humidifier to operate at peak efficiency.
At least 2 inches from wall
Electrical Hook-Up ,
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside
wail. With the humidifier in the desired location, route the electrical cord safely
so no one wilI trip or upset the humidifier. Plug in the electrical cord.
WARNING: To reduce the risk of fire
or shock hazard, humidifier should be plugged into a 120V A.C. outlet.
Do not use extension cords.
To reduce the risk of electrical shock, this humidifier has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
Water Fill
WARNING: TTo reduce the risk of shock, always unplug humidifier
before cteaning or servicing.
WARNING: To reduce the risk of fire or shock hazard, do not pour or spill
water into control or motor area. If controls get wet, let them dry
completely and have unit checked by authorized service personnel before pluggingin.
This humidifier is designed for use with the water bottle located to the ring of the upper grill. The water bottle holds 1.9 gallons of water. The humidifier should be positioned where it will be operating.
To filI the whole house humidifier, grasp the bottle handle at the top of the bottle
and lift it straight up and away from the humidifier base. Take care not to bump or
damage filI valve assembly on the bottom of the bottle.
NOTE; If it is desired to use approved bacteriostat, follow directions correctly.
The bottle of the whole house humidifier will hold 1.9 gallons of water.
The water bottle is designed with an "E-Z FilI Side Cap". Remove the "E-Z-Fill Side- Cap" on the side of the water bottle by twisting counterclockwise.
Place the opening of the water bottle under a water faucet and fill. If desired, add Sears liquid bacteriostat (Stock Number 32-14900) to help control the build up of bacteria and algae. Do not
use solid water treatments. Solid debris could make the lower valve leak.
Install the "E-Z-Fill Side-Cap" by twisting clockwise. Hand tighten only.
Turn Counterclockwise to Remove "E-Z Fill Side Cap"
z/
Spring Valve Aesembmy
Bottte ,,
/
\
-Base
f
//
CAUTION: Use only 32-14900 EPA Registered Bacteriostat available
from Sears Retail store. Under no circumstances should you use water
treatment products designed for Roto belt or Ultrasonic humidifiers.
Water Fill (continued)
Check for possible leaks by performing the following:
1, Grasp bottle handle and hold the bottle
upright over a sink.
2. Press up on the valve cap plunger for about one second to let out a little water.
3. Release the plunger.
4. Listen for air bubbles. Look for leaks around the "E-Z-Fill Side-Cap" and
valve plunger.
5. If you hear air bubbles or see leaks, retighten the "E-Z-FilI Side-Cap" and repeat Steps 1-4.
Wipe off excess water from the bottle.
Position the water bottle back into the the humidifier base to the ring of the grille.
The "E-Z-Fill Side-Cap" must be facing outward. When positioned properly, the
plunger wiII open and water wilI ftow into the base. The base will hold the entire
contents of the water bottle. Allow up to one minute for the water to flow into the
base. Once the bottle is empty, remove it and refill it as mentioned earlier. Return it
to the right side of the grille. The humidifier is now filled to capacity.
The water bottle may be filled at anytime as necessary during operation. To benefit from Iess frequent filling, let the humidifier
exhaust both the water from the bottle and base before filling.
The unit is now ready for operation.
Operating Humidifier Controls
The operating controls of your Kenmore Quiet Comfort whole house humidifier are
located towards the front of the humidifier.
Familiarize yourself with the controls. Reference the diagram of the control
area for the correct nomenclature used in this manual.
To Operate the Controls
Power Light: When the unit is plugged in and turned
on, the red power light will come on. It will stay on until the unit is turned off ( | )
or unplugged. Humidity ControB: @
Adjust the amount of humidity depending on your needs. The humidifier will turn on the off as required to maintain leve! of humidity selected. A medium setting (half way between the controls rotation) is recommended, but there are times when
low or high amount of humidity may be preferred. For constant operation of
humidifier, rotate the control alI the way clockwise allows for the maximum
amount of humidity to be evaporated into the air continuously.
tMPOF{TANT: Water damage may result if condensation starts to form on windows or
wells. Humidity Control setting should be lowered until condensation no longer forms. 7
Speed Control: @ This humidifier has a three speed fan
control switch. ( ,, ) - Low, ( : ) - Medium and ( } ) - High. The maximum humidity
output is obtained with the fan control on High ( _ ).
The higher the air flow speed, the more water is evaporated and released into the air. Low speed (.) is the quietest and is provided for conditions that may not require as high an evaporation rate.
Refill Light: When the unit has a smaII amount of
water Ieft in it, the amber refil! Iight wiII come on and the unit will automatically
shut off.
Power Position
Humidity Speed ControJ Control
Off
RefHmLight
Using Your Humidifier
Step 1 : Be sure humidifier is fuil of water and
plugged in. Stop 2:
Set Speed Control to LOW ( ,, ). Stop 3:
Set Humidity Control to a medium position (see the following diagram).
NOTE: Humidifier should operate with humidity control on the recommended medium setting, if it does not, the humidity is at a relatively high level.
To test the unit under this condition, turn Humidity Control all the way to clockwise and unit should begin to operate. After the unit has been tested, set Humidity
Control to medium or desired level. Allow 24 hours for humidifier to adjust.
if humidity level in home is sufficient, the humidifier will only operate with Humidity
Control set on maximum. IMPORTANT: Water damage my result if
condensation starts to form on windows or wails. Humidity Control setting should
be lowered until condensation no longer forms.
Step 4: if humidifier stops running and amber Refill Light is not illuminated, the humidity leve! is at the normal requirements for that setting or it is adiusting to the home
conditions. The table below shows recommended indoor humidity levels.
The following figure shows approximate relative humidity percentages which correspond to the various settings of the Humidity Control.
When Outdoor Recommended Indoor
Temperature is: Relative Humidity is:
-I 0°F 20% 0°F 25%
10°F 30%
20°F & above 35%
M_N
Operating Tips for Best Performance
1. Position the humidifier at least 2 inches from any wall and away from any heat
registers.
2. Do not restrict airflow from entering or exiting the humidifier.
3. Use Sears recommended bacteriostat 32-14900 to retard bacteria growth
that may cause odors and may be harmful to your health.
4. Perform regular cteaning as instructed in "Cleaning and Maintenance" section
of this manuaI.
5. Replace the evaporative wicking fiIters at least once per humidification season or more depending on water conditions in your area.
Relative Humidity
Replacement and Care of Filter
WARNING: To reduce the risk of shock or injury from moving parts,
always unplug humidifier before removing or replacing any parts.
CAUTION: To help retard bacteria growth and keep maximum efficiency, the filter should be replaced at least once per season, or more often
under hard water conditions+ Use Kenmore 32-14906 recommended
replacement filter+
To replace the filter in your humidifier, follow the instructions below+
1+ Unplug humidifier+ Before removing
the filter, we recommend moving the humidifier to an area where floor
coverings are not susceptible to water damage+ (i+e+kitchen or bath areas+)
2. Remove the water bottle and set aside. Be sure not to bump or damage the
lower spring valve.
3. Grasp the housing assembly and lift straight up and away from the base
and set aside+ The filter is now accessible+
4+ Take note of the filter position+
Remove the filter. You may want to clean the base at this time. See the
"Cleaning Your Humidifier" section of this manual+
5+ Install a new filter (32-14906) into the
base. Coil the filter and position it between the uprights in the bottom of
the base. The start and finish of the coil should be captured at the center
of the base (see diagram) and the filter should be resting on the floor of
the base+
Grasp housing assembly securemy and
lift off
Base Uprights
f Fimter
Base
Replacement and Care of Filter (continued)m
6, Return the housing assembly to the
top of the base, Return the water bottte to the right of the housing assembIy and reposition the humidifier to its operating position,
7, The humidifier is now ready to be filled
for operation,
ABign housing assembly
bottom with
, top of base
/ and reposition
securemy
10
'\,\
Return bottle to right side of
humidifier
Loading...