READ AND SAVE THESE mNSTRUCTmONS
Operator's Manua_
WHOLE HOUSE
10 Gallon Output
Model 758.144108
CAUTION: Before using this
product, read this manua_ and
follow aH its Safety Rumes and
Operating instructions.
o Safety
o Assembmy
o Operation
o Maintenance
o Parts
o EspaSom, p. 17
Sears, Roebuck and Co., Hoffman Estates, mL60179 U.S.A.
wwwosearsocom
Part No. SP6594 Printed in Canada
_"ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER _
ff any part of this humidifier fails due to a defect in materiam or workmanship
within one year from the date of purchase, or it the humidifier motor falls due
to a defect in materiam or workmanship during the second year from the date
of purchase, RETURN THE HUMmDmFiER TO THE NEAREST SEARS PARTS &
REPAIR CENTER, and it will be repaired free of charge. This warranty does
not incmude humidifier filters, which are e×pendabme parts that can wear out
from normal use in messthan one year. This warranty gives you specific megam
rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, mL80179 ,_
GENERAL SAFETY iNSTRUCTiONS
Safety Signal Words
DANGER: means if the safety
information is not followed someone wHI
be seriously injured or killed.
WARNING: means if the safety
information is not followed someone
toured be seriously iniured or killed.
CAUTION: means if the safety
information is not followed someone may
be iniured.
1. To reduce the risk of fire or shock
hazard, plug humidifier directly into a
120V, A.C. electrical outlet. Do not use
extension cords.
2. Keep the electric cord out of traffic
areas. To reduce the risk of fire
hazard, never put the electric cord
under rugs, near heat registers,
radiators, stoves or heaters.
3. Always unplug the humidifier before
moving it, before cleaning, or
whenever the humidifier is not in
service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the
humidifier.
6. Do not allow to be used as a toy.
Close attention is necessary when
used by or near children.
7. Never use your humidifier while any
part is missing or damaged in any
manner.
8. To reduce the risk of electrical
hazard or damage to humidifier, do
not tilt, jolt or tip humidifier while unit
is running.
9. To reduce the risk of damage to
humidifier, unplug when not in use.
10. To reduce the risk of accidental
electrical shock, do not touch the
cord or controis with wet hands.
11. Note the warning label shown below.
WARNING: To reduce risk of fire,
electric shock, or iniury always unplug
before servicing or cleaning.
Table of Contents
Water Fill .............................................. 6-7
Operating Humidifier Controls ............... 7
Using Your Humidifier ............................. 8
Operating Tips for Best Performance .....8
Replacement and Care of Filters .......9-10
Cleaning and Maintenance .............. 11-12
Troubleshooting ................................... 13
Repair Parts ..................................... 14-15
To Save A Service Caff
Check the following if your humidifier is
not operating.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
Know Your Humidifier --
3. Is aidlow control in operating position?
4. Is humidity control set high enough?
5. Is the cabinet sitting on a level
surface?
Fan Assembmy ............
Housing .....
AesemMy ............
Humidit!
Controm
Description
Gallon Output/24 hrs
Capacity of Bottle
Capacity of Base
Sq. Ft. Coverage
Fan Speeds
Auto Fan Speed
Replacement Filter
Power Light
Fill Light
Auto Humidistat
Auto Shut Off
Controls
CUL Listed
Volts
Hertz
Amps (High Speed)
Watts (High Speed)
Bottme Handme
Speed
Control
.........Bottme
Base
Fi_ter:
Replacement No.
32-14908
758.144108
10
1.9 Gallons
2.0 Gallons
2100
3
Yes
32-14906
Yes
Yes
Yes
Yes
Rotary
Yes
120 A.C.
60
0.80
8O
Based on an area with average insulation and an 8 foot
ceiling height
How Your Humidifier Works
Your new Kenmore humidifier is designed
to satisfy home humidity requirements
through the principle of evaporation of
water in the air.
After water is added to the bottle, the
filters begin to soak up the water and
become totally saturated in approxi-
mately 30 minutes. Air is drawn in from
the rear of the humidifier and through the
filters by means of circulation fans. As air
passes through the filters, moisture is
absorbed into the air and then released
in the form of vapor. No water droplets
will enter the home. AII evaporation into
the air takes place in the humidifier,
which means that the residue left by
evaporating water is not passed into the
home, but remains in the filter.
This natural process of evaporation helps
eliminate the change of white dust in the
humidified output air.
CAUTION: Use only 32-14900 EPA
Registered Bacteriostat available
from Sears Retail store. Under no
circumstances should you use water
treatment products designed for
Rote belt or Ultrasonic humidifiers.
Humidified air is
then reteased
throug
Dry air
enters
through
the
Jouvers
in the
housing
CAUTION: To reduce the risk of
iniury, fire or damage to humidifier,
use only cleaners specifically
recommended for humidifiers. Never
use flammable, combustible or
poisonous materials to clean your
humidifier. To reduce the risk of
scalds and damage to humidifier,
never put hot water in humidifier.
Assembly
Carefully remove the humidifier and all
other contents from the carton.
There is a black strip that contains six
pads for the bottom of the humidifier.
Remove each pad and place one on
each of the six legs on the bottom of the
base as shown, by the solid dots.
Once installed return the humidifier to it's
originaI state and proceed to "Location
instructions".
Location Instructions
WARNING: For your own safety, do
not use humidifier if any parts are
damaged or missing.
Step 1 :
Place humidifier on a flat level surface in
an area of your house where humidity is
needed most, or in an area which would
likely result in moist air being circulated
throughout the house, such as near a
cold air return.
Placing the unit level is very important.
Special attention should be given to unit's
level if the humidifier is located on
carpeting.
Moist air (humidity) produced will
disperse into the whole house, but the
area closest to the unit wilI have the
highest humidity. If the unit is positioned
close to a window, condensation may
form on the window pane. If this is not
appropriate the unit should be
repositioned in another location.
NOTE: Due to release of cool, moist air
from humidifier, it is best to direct air
away from thermostat and hot air
registers. It is best to position humidifier
next to an inside wall. Hot air registers
and cold air from outside walls can affect
the efficiencies of the controls. Unit
should not be placed where warm air
from a hot air register blows directly on
unit.
Step 2:
The humidifier should be positioned with
the back (cord exit side) and left side, at
least 2 inches away from the wall. Air
needs to enter through alI of the louvers
in the housing assembly in order for the
humidifier to operate at peak efficiency.
At least 2 inches
from wall
Electrical Hook-Up ,
Locate nearest 120V A.C. wall socket in
the location desired, preferably on inside
wail. With the humidifier in the desired
location, route the electrical cord safely
so no one wilI trip or upset the humidifier.
Plug in the electrical cord.
WARNING: To reduce the risk of fire
or shock hazard, humidifier should
be plugged into a 120V A.C. outlet.
Do not use extension cords.
To reduce the risk of electrical shock, this
humidifier has a polarized plug (one
blade is wider than the other). This plug
will fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet,
reverse plug. If it still does not fit, contact
a qualified electrician to install the proper
outlet. Do not change the plug in any
way.