Kenmore 75130, 580.75144500, 580.75130500, 580.75098500 Owner's Manual

Owner's Manual Manual del Propietario
®
THROUGH-THE-WALLAIRCONDITIONER ACONDICIONADODEAIREATRAVESDEPARED
Model, Modelo 580.75098 580.75130 580.75144
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
Features ................................................. 13
Important Safety Instructions ...................... 3
Installation Requirements ......................... 5
Installation ................................................ 6
Procedure A ............................................. 7
Procedure B ............................................. 8
Procedure C ........................................... 10
OPERATION ........................................... 12
How and Why ......................................... 12
Normal Sounds ...................................... 12
Capacity and Running Time ................... 12
Using the Air Conditioner ....................... 13
Control Panel ......................................... 14
Remote Control ...................................... 15
MAINTENANCE ..................................... 17
Air Filter Cleaning ................................... 17
Air Conditioner Cleaning ........................ 17
How to Remove the Front Grille ............. 17
How to Replace the Front Grille ............. 17
TROUBLESHOOTING ......................... 18
Before Calling for Service ...................... 18
ESPAI_IOL ................................................ 20
MASTER PROTECTION
AGREEMENTS ......................................39
SERVICE NUMBERS ............Back Cover
FULL ONE YEAR WARRANTY ON THROUGH-THE-WALL AIR CONDITIONER
For one year from the date of purchase, when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner's manual, Sears will repair this air conditioner, free of charge, if defective in material or
workmanship.
WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT 1-800-4-MY-HOME ®.
This warranty applies only while this product is in use in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
Sears, Roebuck and Co., D/817WA, Hoffman Estates, IL 60179 U.S.A.
-2-
IMPORTANT SAFETY INSTRUCTIONS
The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or
damage to your ROOM AIR CONDITIONER.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
PREVENT ACCIDENTS
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow
basic precautions, including the following:
Be sure the electrical service is adequate for the
model you have chosen.
If the air conditioner is to be installed in a window,
you will probably want to clean both sides of the glass first. If the window is a triple4rack type with a screen panel included, you may want to remove
the screen completely before installation.
Be sure the air conditioner has been securely and
correctly installed according to the instructions in this manual.
Save this manual and installation instructions for possible future use in removing or reinstalling this
unit.
Use gloves when handling the air conditioner.
Be careful to avoid cuts from sharp metal fins on front and rear coils.
ELECTRICAL INFORMATION
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the
rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded.
To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
Your air conditioner must be plugged into a
properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install
the proper receptacle.
Do not run air conditioner with packing sheet of
the back of the sleeve, and packing corner and blue tape of the air conditioner. This could result in
mechanical damage within the air conditioner.
Do not use an extension cord or an adapter
plug.
_ Avoid fire hazard or electric shock.
Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Power supply cord with 3-prong
grounding plug
ENERGY SAVING IDEAS
The capacity of the room air conditioner must fit the room size for efficient and satisfactory
operation.
Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day.
Do not block air flow inside with blinds, curtains, or furniture; or outside with shrubs, enclosures, or
other buildings.
Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney and into the duct work.
Keep blinds and drapes in other windows closed during the sunniest part of the day.
Glean the air filter as recommended in the
MAINTENANCE section of this manual.
Proper insulation and weather stripping in your home will help keep warm air out and cool air in.
External house shading with trees, plants or awnings will help reduce the air conditioner's work
load.
Operate heat producing appliances such as
ranges, washers, dryers, and dishwashers during
the coolest part of the day.
Do not under any circumstances cut,
remove, or bypass the grounding prong from this plug.
/
-3-
OBSERVE ALL LOCAL CODES AND ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
208!230-volt 60 Hz and 115-volt 60 Hz, AC only, 15A fused and properly grounded
electrical supply is required. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, serving only this appliance. DO NOT USE AN EXTENSION CORD.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance has a power supply cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged intoe mating grounding type wall receptacle and grounded in accordance with the National Electrical Code (ANSI/NFPA 70)
latest edition and all local codes and ordinances. If a mating wall receptacle is not
available, it is the personal responsibility and obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.
115V- 230V-
NOTE; The shape may be different according to its model
Use Wail Receptacle Power Supply
Standard125V,
3-wiregrounding
receptacle rated
15A, 125VAC
Standard 250V, 3-wi_ g_unding
receptacle rated
15A, 25aVAC
Standard 250V, 3_wire grounding Use 20 AMP. time receptacle rated delay fuse or 20 AMP.
20A, 25av AC circuit breaker,
Use 15 AMP, time
delay fuse or 15 AMP. circuit breaker.
Power cord may include a current interrupter device. A test and reset button is provided on the
plug case. The device should be tested on a periodic basis by first pressing the TEST button
and then the RESET button. If the TEST button does not trip or ifthe RESET button will not stay
engaged, discontinue use of the air conditioner and contact a qualified service technician.
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result in death, f{re, or electrical shock.
grounding
plug
Test
3-pron_ _G!
Reset_
Power prong
supply cord
(208/230-volt 60 Hz)
3-prong
receptacle
(115-volt 60 Hz)
-4-
Remove packing materials from the wall sleeve and tape
from the air conditioner.
INSTALLATION REQUIREMENTS
If you use an existing well sleeve, you should measure its dimensions.
Install the new air conditioner according to these installation instructions to achieve the best
performance. All wall sleeves used to mount the new air conditioner must be in good structural
condition and have a rear grille to securely attach the new air conditioner. (FIG. 1) With the Kenmore sleeve, you can maintain the best performance of the new air conditioner.
(511 ram)
18+W_(468 mm)
Air Conditioner FIG. 1
INSTALLATION HARDWARE
ITEM NAME OF PARTS Q'TY
PLASTIC GRILLE 1
VERTICAL INSULATION STRIP 1 (_7 AROUND INSULATION STRIPS 2 (_ HORIZONTAL INSULATION STRIP 1
(_) SUPPORT BLOCK 2 @ BAFFLE 1
TRIM FRAME 2
@ SHIM 2 (_ PLASTIC NUTS AND WASHER SCREWS 4
_0 GRILLE REAR 1
/
ELECTRICAL SERVICE
Check your available electrical service. The power supply available must be the same as that shown
on the unit nameplate (found on left side of cabinet).
All models are equipped with a 3-prong service plug to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to make the necessary corrections. SAVE CARTON for storage and this OWNER'S MANUAL for future
reference. The carton is the best way to store unit during winter or when not in use.
To avoid risk of personal injury, property damage, or product damage due to the weight of this
device and sharp edges that may be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people
are needed to move and install the unit. To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight
of the unit over an extended period of time.
Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and rear coils.
Make sure air conditioner does not fall during installation.
REQUIRED TOOLS:
Tight Fitting gloves
Standard screwdriver
Phillips screwdriver
Pliers
Sharp knife
3/8-inch open end wrench or adjustable
wrench
1/4-inch hex socket and ratchet
Tape measure
Electric drill
1/4-inch drill bit
-5-
INSTALLATION
We strongly recommend the removal of the old wall sleeve and the installation of a new
Kenmore Wall Sleeve, If youdecideto keeptheexistingwallsleeve,
youhaveto redirectthe louvers at theback ofthe
wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect,you run
the risk of poor performance or product failure. This is not covered under the terms ofthe
Kenmorewarranty.
Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the
unit will lessen the chance that service will be
needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts inthe kit. Discard unused parts
ITEM (inches)
Plastic grille
Vertical insulation strip Around Insulation Strips
Horizontal Insulation Strip Support Block
Baffle Shim
Trim Frame Washer Screw
Nuts(Plastic) Grille Rear
263/4 x 161/2 159/16 x 13/8x 13/8
674/8 x 13/8 x 25/32 5927/32 x 1% x 1% 237/32 X 13/8 X 13/16
13/4X 13/8 X 45/16 14 X 4_/2 X _/6
t 1_3/_6X 1 XS/4
Qty.
1 1
1 1
1
2
1
2 2
4 4
1
HOW TO INSTALL
_1 Identify the existing wall sleeve before installing
the unit from the listed below.
Brand
White-Westinghouse Frigidaire Carrier (52F series)
General Electric
/Hotpoint
Whirlpool 25-7/8 16-1/2
Fedders/Emerson 27 16-3/4 16-3/4
Sears/Kenmore 25-7/8 15-17/32 16-23/32 Emerson/Fedders 26-3/4 15-3/4 15
Carrier (51S Series) 25-3/4 16-7/8 18-5/8 Friedrich 27 16-3/4 16-3/4
Wail Sleeve Dimensions (inches)
Width Height Depth
25-1/2 15-1/4 16, 17-1/2
26 15-5/8 16-7/8
or 22
17-1/8
or 23
or 19-3/4
NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition
and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the
Air Conditioner.
I_ Remove old air conditioner from existing wall
sleeve.
i[_l Clean the interior of an existing sleeve.
(Do not disturb seals.)
I_ll Wall sleeve must be securely fastened in wall
before installing the air conditioner. Use the nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.
II_ Prepare the wall sleeve for installation of the
unit. If you plan to use your existing wall sleeve,
and it is not Kenmore, use procedure B or C
below.
ProcedureABrand
Sears/Kenmore White-Westinghouse
Frigidaire Carrier
(52F series) General Electric
/Hotpoint
Whirlpool Carrier (51S series)
Fedders/Emerson
C
Emerson/Fedders Friedrich
Depth(inches)
16-23/32
16, 17-1/2
or 22
16-7/8
17-1/8 or 23
18-5/8 16-3/4
or 19-3/4
15
16-3/4
rlt install new unit into wall sleeve. CAUTION: When installation is completed,
replacement unit MUST have a rearward slope as shown. To achieve 1/4" slope, remove the backing from the 11-13/16" shim strips and attach them as shown below in Fig. 2. Place the higher portion of
shim to the front of the rib on base of wall sleeve.
I3/4.i0.
UNIT Wall sleeve
SHIM PLACEMENT
UNIT INSTALLATION
FIG. 2
-6-
PROCEDURE A
_1 If you are using the new sleeve (optionally
supplied with your unit),skip to step 3. Otherwise, install the plastic grille from the kit.
Cat the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
FIG. 3
_'_ Fasten the 4 washer screws to secure the grille
to the wall sleeve. If you need plastic nuts to
mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the
sleeve and are pressing into the square holes of the rear flanges.
Plastic rear grille
Steelrear
FIG. 6
I_1_ Install the new unit into the wall sleeve.
r_To assemble trim, snap the tab of each piece
into the slot of the other piece as shown below. Slide trim over the front of the air conditioner
until trim is flush with sleeve as shown below.
/
or
_1 Remove the backing from the Vertical
Insulation strip 159/16 X 13/8x 13/8and attach that
to the inside right of the sleeve as shown
below. Remove the backing from the Around Insulation strip 67% x 13/8x 25/32and attach that
to the inside front of the sleeve as shown
below.
Indoor Outdoor
: 9V2" =i_ 6" J
_1 Remove the metal rear grille and replace it with
the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount of hot air discharge that recirculates through the unit.
FIG. 4
FIG. 5
/
Trim (2 ea)
Wall
FIG. 7
Airconditionerscoveredinthismanualposean excessiveweighthazard.Twoormorepeopleare neededtomoveandinstalltheunit.
Topreventinjuryor strain,useproperliftingand carryingtechniqueswhenmovingunit.
Whenhandlingtheair conditioner,becarefulto avoid cutsfromsharpmetalfins onfrontandrearcoils.
Makesureairconditionerdoesnotfallduring removal.
If unitdoesnotoperateafterinstallationcheck,tobe surethecircuitinterrupterhasnotbeentripped.Refer tothe Troubleshootingguidefor resetprocedure.
-7
PROCEDURE B
_1 Redirect the louvers at the back of the wall
sleeve to 60 ° angle as shown in the FIG 8. The
use of pliers is recommended.
7 3/32 '=
Rear Lo uvel'$
(Top View)
_J Remove the backing from the Vertical Insulation
strip 15%6 x 13/8x 13/8 and attach that to the
inside right of the sleeve as shown below. Remove the backing from the Around Insulation
strip 671/8x lS/8x 25/32and attach that to the
inside front of the sleeve as shown below.
Indoor Outdoor
_roundlnsu_alion:
Verticallnsulation
FIG. 8
_lf the wall sleeve already has a rear grille, skip
to step 4. If the wall sleeve does not have a rear grille or Iouvered panel, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the
inside of the wall sleeve at the rear flange
Place the plastic grille
FIG. 9
_1 Fasten the 4 washer screws to secure the grille
to the wall sleeve. If you need plastic nuts to
mount plastic grille to the inside of the wall
sleeve, there are plastic nuts in the installation
kit. The nuts are installed from the inside of the
sleeve and are pressed into the square holes of the rear flanges.
9 V2" i 6" I
FIG. 1 1
_ Remove the metal rear grille and replace it with
the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount
of hot air discharge that recirculates through the unit.
PIsstic rear gritle
Steel resr
FIG. 12
r_lf the depth of your existing wail sleeve is less
than or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks according
to length "A" in the table below.
Depth"D"of the existing Length"A" wallsleeve (inches) (inches)
18 <D _18-5/8 3/4
18-%<D_<19-a/4 1-3/4
19-3/4<D_<22 4
Baffle
IG. 13
Fasten the screws
FIG. 1(]
-8-
PROCEDURE B
_lRemove the backing from the support blocks
and attach them to the inside of the wail sleeve as shown FIG 14. Slide the baffle into slots of the support blocks.
Wall
Wall
Sleeve
FIG. 14
[]install the new unit into the wall sleeve.
[]Assemble trim as described in Step 6,
Procedure A.
/
Airconditionerscoveredinthismanualposean excessiveweighthazard.Twoor morepeopleare
neededtomoveandinstalltheunit. Topreventinjuryorstrain,useproperliftingand
carryingtechniqueswhenmovingunit.
Whenhandlingtheairconditioner,becarefulto avoid cutsfromsharpmetalfinsonfrontandrearcoils.
Makesureairconditionerdoesnotfallduring removal.
If unitdoesnotoperateafterinstallationcheck,to be surethecircuitinterrupterhasnotbeentripped.Refer totheTroubleshootingguidefor resetprocedure.
-9-
PROCEDURE C
_1 Redirect the louvers at the back of the wall
sleeve to 60 ° angle as shown in the FIG 15. The use of pliers is recommended.
7 3132"
_J Remove the backing from the Horizontal
Insulation strip 237/32x 13/8x 13n6and attach
that to the inside right of the sleeve as shown
below. Remove the backing from the Around Insulation strip 5927/32 X 13/8X 13/8and attach
that to the inside front of the sleeve as shown
below<
Rear Louvers
(Top View)
FIG. 15
_lf the wall sleeve already has a rear grille, skip
to step 4. If the wall sleeve does not have a rear grille or Iouvered panel, install the plastic grille from the kit. Cut the plastic grille to 26-1/2" wide and 15-1/2" high. Place the plastic grille to the
inside of the wall sleeve at the rear flange.
Place the plastic grille
FIG. 16
Indoor Outdoor
_lf the depth of your existing sleeve is less than
or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks according to
Length "A" in the table below.
Depth"D" ofthe existing Length"A"
wailsleeve(inches) (inches)
t8 <D_<t8-% 3/4
18-%<Dgt9-3/_ 1-3/4
t9-3/_ <D_<22 4
_F Baffle
IG. 19
_1 Fasten the 4 washer screws to secure the grille
to the wall sleeve. If you need plastic nuts to
mount plastic grille to the inside of the wall
sleeve, there are plastic nuts in the installation
kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
Fasten the screws FIG 17
r_ Remove the backing from the support blocks
and attach them to the inside of the wall sleeve as shown FIG 20. Slide the baffle into slots of the support blocks
Wall
Wall
Sleeve
J
-10-
Support Block
FIG. 20
PROCEDURE C
H To achieve rearward slope for unit draining,
remove the backing from the 11t3/16" shim strips and attach them as shown below in Fig.
21. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve.
"h'0hl[ lI3,<.,g.
FIG< 21
FIG. 22
_J Remove the metal rear grille and replace it with
the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount of hot air discharge that recirculates
through the unit,
Airconditionerscoveredin thismanualposean excessiveweighthazard.Twoormorepeopleare
neededto moveandinstalltheunit. Topreventinjuryorstrain,useproperliftingand carryingtechniqueswhenmovingunit.
Whenhandlingtheairconditioner,becarefulto avoid cutsfromsharpmetalfinsonfrontandrearcoils.
Makesureairconditionerdoesnotfallduring removal.
Ifunitdoesnotoperateafterinstallationcheck,tobe surethecircuitinterrupterhasnotbeentripped.Refer totheTroubleshootingguidefor resetprocedure.
/
Plastic remr grille
Steel rear
I_ Install the new unit into the wall sleeve
_1 Assemble trim as described in Step 6,
Procedure A.
FIG. 23
-11 -
HOW AND WHY
Your room air conditioner provides the following
functions to make hot weather living more
comfortable:
Cools and circulates room air.
Lowers humidity by removing excess moisture.
Filters out summertime dust, dirt, and some airborne impurities.
The air conditioner performs these functions by
drawing room air through a filter which traps dust and dirt particles. The air then passes over a cooling coil which refrigerates the air and removes
excess moisture. The same air is then returned to
the room- cooler, drier, and cleaner. Moisture
removed from the room air is carried to the outside and evaporated.
Your air conditioner is designed to be easy to operate and to provide plenty of cooling power.
NORMAL SOUNDS FIG,24
Aside from the regular fan motor and compressor sounds coming from your air conditioner, you will
once in a while hear a pinging sound. This is the result of moisture being picked up from the air in the
room and thrown against the air conditioner's fan.
This is normal and should not be cause for concern.
Also, do not be alarmed if you hear a slight hissing or gurgling sound coming from your air conditioner after
it is off. These are normal coolant noises.
Fan
You may hear air movement from the fan.
Unit Vibration
The unit may vibrate and make noise
because of poor wail or window construction.
Compressor
The modern high
efficiency compressor may have a high pitched
hum or pulsating noise that cycles on and off.
Condenser
You may hear droplets of water
hitting the condenser,
causing a pinging or clicking sound.
CAPACITY AND RUNNING TIME
Proper unit size is important in deciding the desired comfort for the area you want to cool. The proper
size is determined by the number of square feet in
the area to be cooled.
Whenever the heat or humidity load is above normal the air conditioner must run longer and more often to keep the desired temperature you have selected.
Under heavy heat load conditions the air conditioner
may need to run constantly to keep the temperature
you want.
At times using the MED FAN setting to circulate the
room air may make it comfortable even though you
do not have the air conditioner set to cool the air This will decrease your cost of use.
FIG. 24
-12-