YOUR SAFETY FIRST
BEFORE YOU START
* Proper installation is the installer's responsibility!
- Read the entire manual before you begin.
- The model number label is located on the oven front. See Figure 1.
- Mounting plate is located on back side of microwave oven, See Figure 2.
BE SURE TO READ THE FOLLOWING SAFETY iNSTRUCTiONS:
Model Number Label Mountinc Plate
m
Z
t"
m
Z
Back of oven
Figure I Figure 2
Ak WARNING Ak
FOR YOUR SAFETY:
o You will need TWO people to install this oven. It is heavy and could cause personal injury if not handled
properly. The dimensions of the oven are as follows:
Height : 16-7/16 inches
Width :29-15/16 inches
Depth : 15-3/8 inches
Weight : 54 pounds
o AVOID ELECTRICAL SHOCK!
- Before you drill into the wall, note where electrical outlets are and where electrical wires might be
concealed behind the wall.
YOU COULD GET AN ELECTRIC SHOCK it you contact electrical wires with your drill bit.
- Locate and disconnect the power of any electrical circuits that could be affected by installing this oven.
IF YOU DO NOT DISCONNECT THE POWER, YOU COULD GET AN ELECTRIC SHOCK.
,, ELECTRICAL RATING OF THIS OVEN : 120V, 60Hz.
- You need a 120V, 60Hz, AC only, 20A, fused electrical supply (located in the cabinet above the
microwave as close as possible to the microwave circuit) serving only the microwave.

YOUR SAFETY FIRST
• THIS APPLIANCE MUST BE GROUNDED!
- If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape
wire for the electric current. This appliance is equipped with a cord having a grounding wire with a
grounding plug.
PROPERLY POLARIZED AND
• Place the plug into a properly installed and grounded GROUNDEDOUTLET
outlet. See Figure 3.
• Do not use an extension cord.
• Keep the power cord dry and do not pinch or crush it.
• DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE
THE POWER SUPPLY CORD GROUNDING PRONG!
This appliance MUST be grounded!
Three-Pronged (Grounding) plug
Figure 3
¢}
Ak WARNING
If you use the grounding plug improperly, you risk electric shock!
- Check with a qualified electrician if you are not sure whether the oven is properly grounded or if you do
not completely understand the grounding instructions.
DO NOT USE A FUSE IN THE NEUTRAL OR GROUNDING CIRCUIT.
Zk WARNING
Improper grounding could result in electric shock or other personal injury.
SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR'S USE.
• DO NOT EXPOSE YOURSELF TO EXCESSIVE MICROWAVE ENERGY!
- DO NOT try to operate the microwave oven with the door open.
- DO NOT tamper with or defeat the safety interlocks.
- DO NOT place objects between the microwave oven front face and the door.
- DO NOT allow soil or cleaner residue to build up on the flat surfaces around the microwave oven door.
- DO NOT operate the microwave oven if it is damaged.
- The microwave oven door must close properly to operate safely.
- DO NOT use the microwave oven:
• If the door is bent.
• If the hinges or latches are broken or loose.
• If the door seals, sealing surfaces or glass is broken.
- DO NOT attempt to adjust or repair the oven yourself!
It should be adjusted and repaired by a qualified technician who can check for microwave leakage after
repairing the oven.
Ul
3:
WARNING A
If you do not use the microwave oven as instructed, you could be exposed
to excessive microwave energy.

YOUR SAFETY FIRST
• MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT.
- Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be
constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath.
- ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2" x 4" wall stud.
- DO NOT mount the microwave oven to an island or peninsula cabinet.
- BE SURE the upper cabinet and rear wall structures are able to support 150 Ibs., plus the weight of any
items you place inside the oven or upper cabinet.
- Locate the oven away from strong draft areas, such as windows, doors, and strong heating vents.
- BE SURE you have enough space. See Figure 4 below for minimum vertical and horizontal clearance.
WARNING
If you do not mount the oven as instructed, you risk personal injury and/or
property damage.
30"rain, cabinet openingwidth'
30" rain, clearancefrom bottom
of cabinetto cooking surface
or countertop
(Use templates included
with installation instructions)
Figure 4
CAUTION
/Grounded Plug
(inside upper cabinet)
Power Supply
Cord Hole
• Before you begin installing the oven, PLACE A PIECE OF THE CARTON OR OTHER HEAVY MATERIAL
(a blanket) over the countertop or cooktop to protect it. Do not use a plastic cover.
Failure to protect these surfaces could result inproperty damage.

PARTS, TOOLS, MATERIALS
THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN:
NOTE: Depending on your ventilation requirements, you may not use all of these parts.
Damper/duct connector
(for roof vented or wall vented installation)
Not Actual Size
One power cord clamp bushing - Actual Size (for the cord hole in a metal upper cabinet)
Four 1/4" x 2" lag screws - Actual Size
(for wall stud holes)
Two 1/4" x 3" bolts - Actual Size
(for securing to the upper cabinet)
One power cord clamp and
One dark-colored mounting screw
(to hold the power cord)
Actual Size
61
01
Four 1/4" x 3" toggle bolts - Actual Size
(for drywall holes)
Two tapping screws - Actual Size
(for attaching the damper duct connector)
OR
One upper cabinet template - Not Actual
Size
Four spring toggle heads - Actual Size
(for the toggle bolts)
D
One rear wall template- Not Actual Size
REAR WALI_ TEMPLATE :
NOTE: You need to install at least one lag screw into a 2" x 4" stud and four anchor bolts into the wall,
and the mounting area must meet the 150 Ibs. weight requirement.
I

PARTS, TOOLS, MATERIALS
YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THE
INSTALLATION:
Carton or other heavy material for covering the counter top.
Clear Tape
(for taping the templates to the wall)
Saber Saw (for cutting vent holes for roof
or wall vending)
Phillips Screwdriver (for the screws)
Pencil
Flat Blade Screwdriver (for the toggle bolts)
Stud Finder or Thin Nail
Keyhole Saw (for the power cord hole)
1/2" and 3/16"
drill bits ,,.,,=,=====
Plumb Line
Measuring Tape (metal preferred)
Small Side Cutters or Tin Snips
* If you have brick or masonry walls, you need special hardware and tools.
* The ductwork you need for the installation is not included. All wall and roof caps must have a back-draft
damper.
Duct Tape
Caulking gun