I
' 11-:/e"
0
'3
m
ml
thicknessareontemplate.
.
Alignupper-cabinettemplatecenterlinewithcentarlineofmountingplate.
Securelytapeortackupper-cabinettemplateinplace.
3.
Drilla 3/8 diameter hole intouppercabinetat points J and "K".
I1 If II
I
m
mml
Q
i
- If bottom of upper cabinet is recessed, make 2 fillerblocksas the size of
the shaded areas "G" and "H".
I
r
You mayneed to cutthe fillerblockto fit insideuppercabinetframe.
Markthe cutoutpositiononthe filler blocksthroughthe holesonthe cabinet
bottoma 3Is"die. hole at work in eachblock.
Placethe filler blockssothatthe hole ineach blocklines upwiththe 8/8"
cutoutin the bottomof thecabinet.
Tape fillerblocksto cabinetbottomafter template isremoved.
.
Cut ordrill2"dia, power supply cord hole "M". Installbushingifcabinetismetal
5.
Determinewhicheverventingmethodyouneed.Productis assembledfor
Roomvented(recirculation)installation.Adjustmentsmustbemadeforwallvented
androofventedinstallations.See InstallationInstructions.
- Toventthroughroof,cutoutarea"L" onuppercabinettemplate.
Roofventedlocationcanbeadjustedfora non-recessedcabinet.
GotoSTEP3,ininstallationInstructions.
- Toventthroughthewall,gotoSTEP3, inInstallationInstructions.
- Forroomventedinstallation,gotoSTEP4, inInstallationInstructions.
.
Removetemplate.Completeinstallationaccordingtomicrowaveoven
InstallationInstructions
The "Rearwall" arrows must
be against the rear wall so that
the holes cut in the cabinetbottom
and the holes in the top of the
microwavecabinet will align.
Rear
wall
i
i
8" 5/16"
The "Rearwall" arrows must
beagainst the rear wall so that
the holes cut in the cabinetbottom
and the holes inthe top of the
microwavecabinet will align.
Rear
wall
mlb
.4=,
mlb
I%:)
|
r
1/2" 3h" 1" 1-1/4"
I
' ,11-:/e"
met_lico.
5.Establezcaelm6tododeventilaci6nquenecesita.Elproductose
hamontadoparaunainstalacibn(recirculacibn)delaventilacibnde
lahabitacibn.Sedebenrealizarlosajustesnecesariosparalas
instalacionesdeventilacibndelahaSitacibnodepared.Consultelas
Instruccionesdeinstalacibn.
- Paraventilaratrav6sdeltecho,corteel_rea"L" delaplantilladel
compartimentosuperior.Laubicacibndelaventilacibndeltechose
debeajustarparauncompartimentoquenoretroceda.Consulteel
PASO3delasInstruccionesdeinstalacibn.
- Paraventilaratrav_ dela pared,consulteelPASO3 delas
Instruccionesdeinstalaci6n.
- Paralainstala¢iOndelaventila¢iOndelahabitaci6n,consulteel
PASO4delasInstruccionesdeinstalaci6n.
6.Retirelaplantilla.Completelainstalacibnseg_nlasInstrucciones
deinstalaci6ndelhornomicroondas.
Lasflechasdela "Paredtrasera"
debencolocarsecontralapared
traseradeformaquesealineen
elcortedelosagujerosdela
parteinferiordelcompartimento
ylosdelapartesuperiordel
compartimentodelmicroondas.
Pared
trasera
8" 5/16q
Lasflechasdela"Paredtrasera"
debencolocarsecontralapared
traseradeformaquesealineen
elcortedelosagujerosdela
parteinferiordelcompartimento
ylosdelapartesuperiordel
compartimentodelmicroondas.
Pared
trasera
m
m_
,mlb
II
mlb
1/2" 3/4" 1" 1-1/4" I