Operating Instructions
Parts List
CAUTION:
Read and follow all Safety Rules and Operating
Instructions before first use of this Product.
INFO-LINE
After having read this manual, if you have any questions or
comments on your Kenmore
Humidifier call:
1-800-332-1110
Sears, Roebuck and Co., Hoffman Estates, IL 601 79 U.S.A.
iNTRODUCTiON
Congratulations on your choice of the Kenmore Model
42.14121 Evaporative Humidifier. This humidifier produces COOL, moist air. Before using your humidifier, take a few moments to understand and appreciate the benefits of maintaining your home at a proper humidity level.
Air that is too dry is not only uncomfortable, but it can also deprive your skin, house plants and furnishings of valuable moisture. Dry air in your home can cause the build-up of static electric charges.
This humidifier is designed to pull dry air through the Evaporative Filter Pad system, a quiet fan then disperses INVISIBLE MOISTURE-BALANCED AIR into your house. Minerals and bacteria from the water are trapped inside the FILTER Pad so that they do not
"mist" into the room and create white dust accumulation on room surfaces.
Your Kenmore Humidifier comes fully assembled and ready for immediate use.
GENERAL SAFETY INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire,
electrical shock and injury to persons, including the following:
1. Read all instructions before using this humidifier.
.
This product isequipped with a polarized alternating current line plug (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. This is a SAFETY FEATURE. If you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact an electrician to replace the obsolete outlet. DO NOT do anything that will defeat the safety purpose of the
polarized plug.
=
This humidifier may not work properly on an uneven surface. Always place this humidifier on a firm, flat surface. SEARS cannot accept responsibility for
damage to property caused by water spillage.
.
Do not operate the humidifier with a damaged cord or plug or after the humidifier malfunctions, has been dropped or damaged in any manner. Return the unit to SEARS for examination, electrical or mechanical adjustment or repair.
.
Do not run the power cord under carpeting. Do not cover cord with throw rugs, runners or the like.
Arrange the power cord away from traffic areas and where it will not be tripped over.
.
Always unplug the humidifier when it is not operating, when moving or cleaning it, or when changing its replacement filter or otherwise servicing it.
.
Do not place the humidifier near heat sources such as stoves, radiators and heaters.
.
This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as
instructed in this manual.
9. Turn the humidifier OFF if the relative humidity exceeds 60%. For proper humidity readings, use a hygrometer (available at Sears).
10. SAVE THESE IMPORTANT INSTRUCTIONS.
HOW YOUR KENMORE EVAPORATIVE TABLE TOP HUMIDIFIER WORKS
Lack of humidity in the air usually caused by winter heating and summer air conditioning can dry out your
nose, throat and skin. KENMORE humidifiers put moisture back into the air
you breathe and may help to relieve symptoms of sinus and respiratory problems, reduce annoying static electricity discharges and provide a healthy growing environment for your indoor plants.
Water is constantly being drawn up from the Base Reservoir into the Filter Pad. The fan draws dry room air through the filter's intricate pattern where it becomes moisture-saturated; this invisible air is then blown through the Exhaust Grill and into the room. SEARS built-in moisture balance system naturally increases moisture output when the air is dry and
lowersthemoistureoutputwhenthehumiditylevelis high.Thismoisturebalancesystemhelpsreduceany watercondensationthatmightoccuronwalls,
windowsandfurniture.
DRY ROOM
AIR IN
UPPER MOTOR HOUSING
HEALTHY, MOISTURE-LADEN AIR OUT
WATER TANK
\
BASE RESERVOIR
FILLING
CAUTION: It is recommended that ALL HUMIDIFIERS BE DISINFECTED prior to use. Please see the
CLEANING section and follow instructions for RESERVOIR DISINFECTING.
Step #1 Unplug the humidifier. Remove the Upper Motor
Housing Assembly and the Water Tanks from the Base Reservoir. Remove the Water Tanks by grasping the handle and pulling straight up. Make sure that the Evaporative Filter Pad is properly positioned.
Step #2 Prior to filling be sure to remove the Filter Pad and
wipe out any residual water with a clean cloth or paper towel. Replace the Filter Pads and Upper Motor Housing Assembly on the Base Reservoir.
Step#3 TurntheWaterTanksupside-downandunscrewthe
capbyturningcounter-clockwise.FilltheWaterTank withCOOLtapwater.NEVERUSEHOTWATER. HotwatermaycausedamagetotheFilterPadorto
theHumidifier. Step#4
ReplacethecapsontheWaterTanksandplacethe filledWaterTanksontheBaseReservoirandallowit
toempty.
CAUTION: NEVER POUR WATER THROUGH THE EXHAUST GRILL ON THE UPPER
MOTOR HOUSING, DOING SO MAY CAUSE DAMAGE AND PERSONAL INJURY.
OPERATION
Step #1 Be sure that the humidifier has been placed on a firm,
flat and level surface. Remember that this product uses water and always carry the Water Tank carefully. As with any water-filled appliance, there is always the possibility of some spillage. Water can damage furniture and some flooring, so we recommend that the humidifier be placed on a water resistant surface for protection from water spillage.
SEARS CANNOT ACCEPT RESPONSIBILITY
FOR DAMAGE TO PROPERTY CAUSED BY
WATER SPILLAGE.
Step #2 With the Moisture Output Control Knob in the OFF
position, plug the humidifier into a polarized 120 volt AC wall outlet. Do not use an extension cord. DO NOT
FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way. DO NOT PLUG IN THE
HUMIDIFIER WITH WET HANDS AS AN ELECTRIC SHOCK COULD OCCUR.
Step#3 TurntheHumidityLevel(Humidistat)Knobto HIGH(+).
Step#4 SettheMoistureOutputControlKnobtothedesired
position.
-HIGH for fast humidifying. High speed operation will
provide approximately 3 gallons of moisture per day.
-MED for normal operation.
-LOW for quiet nighttime operation. Low speed will
provide up to 20 hours of continuous operation on each filling.
NOTE: IF THE HUMIDIFIER FAN WILL NOT START
OR RESTART WHEN YOU SELECT A FAN SPEED, THE HUMIDISTAT MAY BE SET TOO LOW. MOVING
THE HUMIDITY LEVEL KNOB TO A HIGHER SETTING SHOULD START THE FAN.
The length of time your humidifier runs will vary depending on the quality of construction and insulation of your room or house, as well as the fan speed.
Step #5 Adjust the round Air Outlet Grill on the top of the Upper
Motor Housing (above the fan) to direct moisture in the desired direction. DO NOT aim the moisture flow
toward furniture or walls that could be damaged by excessive moisture.
When a comfortable humidity level is reached, lower the Humidity Level (Humidistat) setting slowly until the fan stops. The DESIRED HUMIDITY light will then illuminate, indicating that the desired humidity setting has been reached. The Humidistat will automatically restart the fan each time the humidity level falls below this setting. This "ON/OFF" cycle will continue periodically while the humidifier is in use.
Lower the Humidity level setting if condensation forms on walls or windows.
Step#6 ResidueontheFilterPadcanreduceitsusablelife.To
preventthebuildupofresidueinandontheFilterPad, turnthepadover,topto bottom,ateveryfilling.Also, anywaterleftinthebottomoftheBaseReservoir shouldbeemptiedateveryfilling.Witheachemptying, useaspongeorpapertowelto wipetheBase Reservoirdry.
CLEANING
Weekly cleaning is required for proper operation of this humidifier. Tap water may contain impurities or dissolved solids which could leave a residue upon the
inner surfaces of the humidifier and on the Filter Pad. Water residue can inhibit the wicking ability of the
Evaporative Pad and shorten its usable life. It is recommended that you clean this humidifier every
week or more often where water quality is poor. More frequent cleaning may be necessary if you see a heavy build-up of impurities.
TO CLEAN THE HUMIDIFIER Step #1
Turn the humidifier OFF and UNPLUG the unit. Step #2
Remove the Upper Motor Housing, Water Tank and the Filter Pad from the Base Reservoir.
Step #3 Empty the Base Reservoir and Water Tank and rinse
with clean tap water. NOTE: FAILURE TO REMOVE THE FILTER PAD
BEFORE CLEANING WiLL DESTROY THE PAD. Step #4
Scale Removal (Perform this operation weekly)
A. With the Filter Pad removed, fill the Base Reservoir
with water and add 8 oz. of undiluted white vinegar.
B. Fill the Water Tank 3/4 full with a mixture of water
and 6 oz. of undiluted white vinegar. Seal and shake vigorously.
WARNING
DO NOT USE GASOLINE, PAINT
THINNER OR OTHER FLAMMABLE
SOLVENTS TO CLEAN THIS HUMIDIFIER.
O. Clean all interior surfaces of the Base Reservoir
with a soft brush or cloth to remove any scale. DO NOT USE SOAP OR DETERGENTS AND
NEVER USE AN ABRASIVE CLEANER.
D. Carefully clean the Upper Motor Assembly with a
dry cloth.
E. Empty and rinse the Base Reservoir and Water
Tank with clean water to remove scale and
remaining cleaning solution before disinfecting
the reservoir.
Step #5
Reservoir Disinfecting (Perform this operation weekly.)
A. With the Filter Pad removed, fill the Base Reservoir
with one gallon of water and add 1 teaspoon of household bleach. Fill the Water Tank with water
and add 1 teaspoon of household bleach. Let the solutions stand for 20 minutes, swishing every few
minutes. Wet all inner surfaces.
B. Empty the Base Reservoir and Water Tank and rinse
with water until the bleach odor is gone. Dry the Base Reservoir with a clean cloth or paper towel.
Step #6 Remember, AgION T"prevents the Evaporative Pad from
growing fungus, mold and bacteria. It is normal for the filter to discolor from mineral build-up. This will vary depending on your water quality. However, if the pad has a noticeable build-up of impurities, rinse it gently in clean tap water or change it. Do not squeeze