Kenmore 40753571310 Owner’s Manual

Use & Care Guide Manual de Uso y Cuidado
English / Espafiol
Models, Modelos: 407.53571
I enmore
Dehum°di er
with externa_ pump
Deshumiditlcador
Sears Brands Management Corporation Hoffman Estates, IL 60179 U.S.A.
www.sears.com www.kmart.com www.kenmore.com
Package Contents.............................................2
Warranty ...........................................................2
Safety instructions............................................3
Electrical Requirements ..................................4
Installation ........................................................4,5
Key Features ....................................................5
Control Panel ...................................................6
Water Disposing Options ........................... 7
Installing the Gravity Drain Hose..................8,9
Installingthe External Pump................. 10,11
Using the Pump............................. ......12
Care and Maintenance ....................... 13
Troubleshooting,..... .....................................1,4,15
Error Codes........................................ 16
Product Specifications .............. .......... 16,17
Master Protection Agreements ............... 18
Spanish Section.................................... 19
Sears Service ................................Back Cover
...._: Kenmore Dehumidifier 3 ft. Dehumidifier Drain Hose ......
* External Vertical Pump
16 ft. Pump Drain Hose * Drain Joint,2 Hose Clamps, 2 Screws * Use& Care Guide
Kenmore Urn|ted Warranty
When installed, operated and maintained according to all supplied instructions, if this appliance fails due
to a defect in material and workmanship within one year from the date of purchase, call 1-800-4-MY- HOME® to arrange for free repair.
If this appliance isever used for other than private family purposes, this warranty applies for onty 90 days from the date of purchase.
This warranty covers only defects in material and workmanship. Warranty coverage does NOT include:
1. Expendable items that can wear out from normal use, including but not limited to filters, belts, light bulbs, and bags.
2. A service technician to instruct the user in correct product Tnstallation, operation or maintenance.
3. A service technician to clean or maintain this product.
4. Damage to or failure of this product if it is not installed, operated or maintained according to the all instructions supplied with the product.
5. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended purpose.
6. Damage to or failure ofthis product caused by the use of detergents, cleaners, chemicals or
utensils other than those recommended in all instructions supplied with the product.
7. : Damage to or failure of parts or systems resulting from unauthorized modifications made to this
product.
Disclaimer of implied warranties; limitation of remedies Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided
herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or conse-
quential damages, Some states and provinces do not allow the exclusion or limitation of incidental or
consequential damages, or limitation on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies onJy while this appliance is used in the United States°
Thiswarranty gives you specific legal rights, and you may also have other rights which vary fromstate to state.
Sears BrandsManagement Corporation, HafTman Estates,IL 60179
2
IMPORTANT CAUTIONSFOR USING YOUR DEHUMIDIFIER.
To reducethe riskof fire, elect_cal shock_injury_or damage to the
dehumidifiers,thesesafety precautionsmustbe followed:
Safety
Do not place the power cord near a heater.
Do not use an electrical outlet near flam-
mable or combustible materials such as gasoline, propane, paint thinners, etc.
Do not disassemble or modify dehumidifier parts or components. It may cause electric
shock and failure.
Plug in the power cord properly.
Do not turn the unit on and off by inserting or pulling out the power plug.
Do not damage the power cord or use an unspecified power cord.
Do not modify power cord length.
Do not share the outlet with another appli-
a nce.
Always plug into a grounded outlet. Not
grounding unit may cause electrical shock.
Unplug the unit if it emits strange sounds, odors, or smoke.
Do not use an electrical outlet if it is loose
or damaged.
Do not operate or plug in unit with wet
hands or in a wet environment.
' Ventilate area before operating dehumidi-
fier. Check for the presence of natural gas
or the buildup of other combustible vapors:
Do not clean the dehumidifier with water. Water may enter the unit and degrade the
insulation resulting in an electrical shock.
If water enters the product, turn off the
dehumidifier's power switch, then unplug the unit. Do not plug in unit until it has been
inspected by an authorized repair service.
Because the fan rotates at high speed dur-
ing operation, always unplug dehumidifier before attempting any recommended
maintenance or cleaning.
Do not block the inlet or outlet. It may cause unit to fall or to operate inefficiently.
Do not remove plug from outlet by pull- ing on the cord.
When not in use, turning the unit off wilt
save energy. Unplug the dehumidifier when not using for long periods of time.
'When removing the filter, be aware that some metal parts may have sharp edges
and may cause injury.
Do not use the water collected in the
bucket for drinking purposes. It is not
sanitary and could cause illness.
Do not allow children to play with this
product.
Tips
Make sure the dehumidifier is the correct size for the area you want to dehumidify.
it is not designed to dehumidify the entire house.
For proper operation, the dehumidifier should only be placed on a level floor.
Close all doors, windows and other open-
ings to the room. The dehumidifier must operate in an enclosed area to be effec-
tive.
° To clean, use a soft cloth; do not use
wax, thinners, or strong detergents as they may change the color of the unit or
cause surface damage.
Be sure to replace the bucket properly after emptying to prevent water from
collecting on the floor causing damage to some types of flooring.
Do not put a pet or house plant where it will be exposed to direct air flow. This
could injure the pet or plant.
Operation without filter will cause unit
failure. Insert the filter securely. Clean it every two weeks. (See Care and Mainte- nance section in this manual.)
OBSERVEALLLOCALCODESAND ORDI- NANCES.
DONOT,UNDERANYCIRCUMSTANCES,
REMOVE THE POWER SUPPLYCORD GROUND PRONG,
ELECTRICALGROUND IS REQUIREDON THIS APPLIANCE
A 11S-VOLT60Hz, AC ONLY, 15A FUSED AND PROPERLYGROUNDED ELECTRICAL
SUPLLYIS REQUIRED.
A time delay fuse or time delay circuit breaker is recommended. Use a dedicated
circuit serving only this appliance.
RECOMMENDED GROUNDING METH- OD
For your personal safety, this appliance must be grounded. Thisappliance has a
power supply cord with a 3-prong ground- ed plug. To minimize possible shock haz- ard the cord must be plugged into a
matching grounded electrical outlet that complies with the latest edition of the
National Electrical Codes and all local codes and ordinances.
If a grounded 3-prong electrical outlet is
not available, it isthe personal responsibil-
ity and obligation of the customer to have one installed by a qualified electrician.
ELECTRICALSHOCK HAZARD
3-prong grounded plug
Power supply cord
DO NOT USEAN EXTENSION CORD.
Install the dehumidifier on a level floor
strong enough to supportthe unitwith a full bucket of water.
For best performance, allow at least 12-18 inches of air space on all sidesof the unit
for good air circulation.
Keep all outside doors,windows and other openingsclosed when operating the dehu-
midifier. Humid outdoor air will add to the unit'sworkload.
Leave the dehumidifier in an upright posi- tion for 30 minutesbefore turning on.
Grounded 3-prong electrical outlet
.................... wAR.I.G
i/ii
Plug into a grounded 3-prong outlet.
Do not remove the ground pin from the plug.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire or electrical shock.
DEFROSTOPERATION
The dehumidifier has a built-in defrost controlthat sensesfrost buildup on the
evaporator coils.
During defrosting, the compressor will automatically turn off; the fan will continue
running to defrost the coils.
4
CHOOSING THE PROPERLOCATION
Use the dehumidifier:
in the basement to help prevent moisture
damage.
tn the kitchen,laundry room, bathroom, and spa/exercise areas that have exces-
sivemoisture.
to prevent moisture damage anywhere books or valuables are stored.
during constructionor remodeling to reduce drying time for drywall and paint.
However, checkand clean filter often.
- ii I "1 IIIIIIIIIIIIIIIIIIIIII1_ g II I I IIIIIIIIIIIIIIIIIII I ' _1- [ I 111111111111 I II II IIIIIIIIII1[ i i iuiiiiiiiiiiiiiiiiii J
To reduce the risk of fire, electric shock or injury to persons, read the important SAFETY IN-
J , - , ,, ......_ W ARNING ,..............
I I IIIIIIIIII II/I * i i i i iiii iiiiiiiiI II I I _ II
STRUCTIONS found on page 3 before operating this appliance.
AUTOMATIC SHUT OFF
When the bucket is full, or when the bucket has been removed, the compres-
sor will automatically stop. The fan will continue to run to dehumidify for 3
minutes. Then the Bucket Full indicator
will flash and you wil! hear a ten second audible alarm.
The bucket must be placed in the proper position for the dehumidifier to work.
The Bucket Full light will flash and the dehumidifier will not run if the bucket is
not in the proper position. Dehumidifier settings can not be changed when the bucket is not in its proper position.
The dehumidifier fan will shut off in 3 minutes, once the desired Relative Hu-
midity (RH) setting is reached, plus or
minus 5% RH.
Washable Filter
Enclosure
\
Power Cord
Continuous Drain
Connector Door
Dehumidifier
Power Cord
16 ft. Pump Drain Hose
3ft.
Dehumidifier
Hose
Bucket
Vertical
Pump
Caster
(8) (g) (lp) (12)(13)
(s) (2)
POWERON/OFF(1)
Once the unit is plugged in, the POWER INDICA- TOR (10) will light. Pressing the POWER button
once will turn the unit ON and illuminate the digi-
tal display (9). The fan will operate for 3 minutes to draw air through the dehumidifier to properly
sense relative humidity. The display will show the
humidity level of the room in 5% increments,
down to a minimum of 25%. Pressing the Power
button again will turn the display OFF and the unit will cease operating.
HUMIDITY LEVEL(2/3) The humidity level can be set in 5% incrementsin
a range from 35% to 80%. The humidity setting
isshownin the digital display. When the humidi-
ty level of the room reaches the set level, the compressor will stop, but the fan will continue
operating for 3 minutes.To set the unit to continu- ousoperation, pressthe clownarrow button until the display shows35%. Pressagain and the dis-
play will showCO. The Continuousindicator (13)
will light up on the control panel. To leave contin-
uousoperation, pressthe UParrow. To check the current humiditysetting, pressthe up
or down arrow. The display will showand set 5%
above or below the currentsettings.
FAN SPEED(5) PressFan Speed to toggle between Low,Med,
and Highfan speeds. Speed will be shownin FAN
SPEEDINDICATOR (8)
BUCKETFULLINDICATOR (11) When the collection bucket isfull, the BUCKET
FULLIndicator (11)will light up and you will hear an audible alarm. The audible alarm will last up
to ten secondsThe dehumidifier will not rununtil the bucket is removed, emptied and replaced.
(3) (1) (6)
DELAY START (4) Unit can be programmed to turn on at a desired
delay time by pressing the Timer (4) key. When the unit is powered OFF, press the timer key once for 2-hour delay start. The 2 Hrs (7) timer indica- tor will light up when the timer key is pressed.
Pressthe timer key once more for a 4-hour delay start. The 4 Hrs (7) timer indicator will now light up. Pressthe timer key a third time to clear the timer setting. No timer indicators will light up
when the timer setting is cleared.
AUTO SHUT-OFF (4)
Unit can be programmed to turn off at a desired time by pressing the Timer (4) key. When the unit
is powered ON, press the timer key once for 2- hour automatic shut-off. The 2 Hrs (7) timer indi-
cator will light up when the timer key is pressed.
Pressthe timer key once more for a 4-hour auto- matic shut-o_. The 4 Hrs (7) timer indicator will now light up. Press the timer key a third time to clear the timer setting. No timer indicators Will
light up when the timer setting is cleared.
FILTERRESET(12) The FILTERRESETindicator (12) will light up when
the filter needscleaning. Removethe filter and clean accordingly. Replace the filter when fin-
ishedand pressand hold the FILTER(6) key upto
5 secondsto reset the filter indicator.
IMPORTANT.
Once the set humidity level isreached, the compressorwill shutoff. The fan will contin- ueto runfor up to 3 minutes.
Anytime the compressorstopsrunning for any reason, it will not restart for a minimum of 3 minutes.Thisis a design feature to pro- tect the compressorfrom damage.
OPTION 1"EMPTYING MANUALLY
1. Pull out the bucket, grasping the side handles. (Fig. 1)
2. Carry the bucket by grasping the front corner of the bucket with one hand and the back of the bucket with the other hand( Fig. 2)
3. Empty the bucket and replace the bucket in the dehumidifier. (Fig. 3)
NOTE: Dehumidifier will not work and settingscan not be changed when the BUCKETFULL indicator light is flashing or without the bucket properly installed.
DO NOT REMOVE THE STYROFOAM IN THE BUCKET
This dehumidifier is equipped with a reliable Styrofoam float system. The Styrofoam
located inside the float in the bucket is essential to the bucket full system working properly. Do not remove the Styrofoam from the float.
(Fig. 1)
L
(Fig. 2)
(Fig. 3)
Step 2=Open the drain connector door. (Figl 6)
I
I
]
1 l
(FIG. 6)
Step 3= Install and secure the drainage joint onto the drain connector. (Fig. 7)
(FIG. 7)
Step 4= Place large hose clamp on the fiat end of the dehumidifier drain hose. (Fig.
s)
/
(FIG. 8)
Step 5- Insert the drain hose onto the drainage joint so that it is fully seated. (Fig. 9)
(FIG. 9)
Step 5; Secure hose by pushing large hose clamp towards the drainage joint. (Fig.
lo) !
r
_'__ (FIG. 101
Step 6. Place bucket in the dehumidifier for operation. (Fig. 11)
(FIG. 11)
9
OPTION 3: EXTERNALVERTICALPUMP
INSTALLING THE _RNAL PUMP
Step 1: To install Dehumidifier Drain Hose, refer to Gravity Drain Using Dehumidifier Hose instructions starting on page 9.
Step 2= For optimal operation, it is recommended that the pump is placed on a fiat and level location. Attach the water pump to a wall or other perpendicular fiat surface with the included screws for security. (Fig. 12)
Step :3. Remove red cap from drain hose connector on pump. Attach the small drain hose clamp onto the pump drain hose.
(Fig. 13)
(FIG. 13)
]0
Step 4= Insert pump drain hose onto pump connector until it is
fully seated. Secure hose by pushing small clamp forward
towards the pump. (Fig. 14)
\
\ ! /t
(FIG. 14)
Step 5. Secure hose by pushing small clamp forward towards
the pump. (Fig. 15}
fi
tt
(FIG. 15)
Step 6. Insert the angled end of the dehumidifier drain hose
into the water pump tank. (Fig. 16).
___
])
(FIG, 16)
NOTE- Make sure the drain hose is lower than the horizontal plane of the drain on the dehumidifier as seen in the illustration below. Drain hose should be as short as
possible and all kinks in the drain hose should be eliminated for proper pump opera-
tion.
i
3ft. Dehumidifier Drain Hose
NOTE- If you need to cut the dehumidifier drain hose, only cut on the fiat end of the hose. Do not cut the angled end as it is designed for insertion into the pump.
i
i
!
|
(FIG, t7)
4
CUT DO NOT CUT
J
X
1. Remove flat end of the hose by squeezing the large clamp and pulling it to- ward you.
2. Remove hose from drainage joint and cut hose to appropriate length.
3. Once cut is completed, refer to installing the Drain Hose to re-install dehumid-
ifier drain hose.
USING THE DRAIN PUMP
1. Plug into grounded electrical outlet.
2. Place the other end of the pump hose where you would like to empty the wa- ter (floor drain, water container or through a basement window). The pump will automatically start and begin pumping the water that drains into it. Check
hose for kinks or other obstructions.
3. Before and after each use, check hose connections to make sure they are
properly secured.
12