contents
WARRANTY ........................................... 2
BEFORE YOU START
Rules for Safe Installation
and Operation ................................... 2
Tools and Materials Needed .............. 2
UNDERSTANDING HUMIDITY .............. 3
SELECTINGA LOCATION .................... 4
INSTALLATION...................................... 4
DISASSEMBLY...................................... 4
WATER SUPPLY................................... 6
HUMIDISTAT.......................................... 7
OPERATION .......................................... 8
MAINTENANCE ..................................... 9
SERVICE HINTS .................................. 10
REPAIR PARTS .................................... 11
introduction
Please readthe instructionsbeforeyou installanduseyourhumidifier.Thiswillhelpyouobtainthe fullvaluefromthe humidifier.It will
also helpyou avoidanyneedless servicecost,ifthe problemissomethingwe cannotcontroland cannotcoverinourWarranty.
FULL ONE YEAR WARRANTY ON HUMIDIFIER
If, within oneyear fromthe date of pumhaee, this humidifier failsdue to a defect in material or workmanship, Seers will
repair it,free of charge.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS STORE OR SERVICE
CENTER INTHE UNITED STATES.
This warranty gives you specific legal rights,and you may also have other rights which vary from state to state.
This warranty DOES NOTcover the replacement media pad.
Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179
DO-IT-YOURSELF CHECK LIST
Ifyoufeelthefollowingoperationsare withinyourskills,youshould
haveno difficultyinstallingthishumidifier.
[] Cuttingand drillingsheet metal.
[] Usinghand tools:screwdriver,wrench,etc.
[] Rookingup lowvoltage electricalconnections.
SEARS INSTALLATION POLICY
AllinstallationlaborarrangedbySears willbeperformedina neat,
workmanlikemannerinaccordancewithgenerallyacceptedtrade
practices.Further,all installationswillcomplywithall local laws,
codes, regulations,and ordinances.The customerwillalso be
protected,duringinstallation,by insurancerelatingto property
damage,Work]nan'sCompensation,andpublicliability.
Youmustrealizethat thewrong use of any toolcanbe danger-
ous. Be sureyouknowhowto use the toolsand equipmentto
avoidany possiblehazards.If you haveany doubtwe askthat
youcontactyourSearssalesperson.They willarrangefor profes-
sionalinstallation.
SEARS INSTALLATION WARRANTY
In additionto anywarranty extendedto youon the Sears mar-
chandiseinvolved,whichwarranty becomes effectivethe date
themerchandise isinstalled,shouldtheworlonanshipofanySears
arrangedinstallationprovefaultywithinoneyear,Searswill,upon
noticefrom you, cause suchfaults to be correctedat no addi-
tionalcostto you.
before you start
RULES FOR SAFE INSTALLATION & OPERATION
1. Read theserules andtheinstructionscarefully.Failuretofol-
lowthe rules and instructionscouldcausebodilyinjuryand/
or propertydamage.
2. Check your local buildingcodes and utilitystandards.The
installationmustcomplywiththeir rules.
3. Alwaysshutoffthefurnaceblowerbeforeinstallingorservic-
ingthe humidifier.
4. Alwayswearsafetyglasseswhen installingor servicing.
5. HUMIDIFIER MUST NOTBE INSTALLEDINAREAWHERE
FREEZING IS POSSIBLE OR LEAKING WOULD CAUSE
WATER DAMAGE.
6. Followa regularservice and maintenanceschedule.
7. Alwaysshutoffelectricityandwatertothehumidifierbefore
servicing.
8. Whenthefurnacebloweris usedfor air-conditioning, thehu-
midifierdampershouldbe closed,andthe humidistatshould
beturnedto the minimumhumiditysetting.
g. NEVER OIL ANY PARTOFTHE HUMIDIFIER.
10. To preventoverhumidification,humidifiermust notbe oper-
ated above humidiatat high position or above the +20
position (whichever applies) except briefly to test op-
eration after installation or servicing.
TOOLS AND MATERIALS NEEDED
• SafetyGlasses
• Straightedge ruler
• Pencilor greasepencil
• Handdrillorgrounded
electricdrill
• Drillbits, 5/32",118"
• "r]nsnipsor metal
cuttingsaw
• Wire strippersor razorknife
• Screwdriver(flat point,and
Phillips,mediumsize)
• File
• Level
• Hammer
• Smelladjustablewrench
• Centerpunch
• Springhoseclamppliers
THANK YOU!
Thankyouforselectinga Sears Humidifier.Itwillprovideyearsof serviceif yougiveit a littlecare.
UNDERSTANDING HUMIDITY
Humiditycan be puzzling. It cannot be seen, heard, touched,
smelledortasted. Many peopledo notunderstandwhata humidi-
fierwillorwill notdo.
Probablythe bestway tojudgewhetherthe humidityistoo high,
toolowor aboutrightisto watchyourwindows.Ifthey areheavily
fogged you mostlikelyhave too much. Ifthere is nomoistureon
TYPICAL QUESTIONS ASKED
them at all, especiallyinthe corners,you have too little.(NOTE:
Moisturewill notnormallyformonthermopaneor whenstormwin.
dowsare used.) ff there issome moistureinthe windowcorners
andalongtheedges,thehumidityisjustabout right.Thisisa good
role of thumb, it you do not have an expensivepiece of testing
equipment.Yourcomfortis anothergoodcheck.
1. Why do moisture requirements vary from home to home?
Requirementsdepend onthe amount anddrynessof airto be
humidified.The largerand morelooselyconstructedthe home,
the greaterthe quantityof moisture required.
2. How can I best check my home's relative humidity?
Firstgive your humidifiertime to buildup the humidityto an
acceptablelevel.Instrumentsare availabletomeasurerelative
humidity,but from a practicalstandpoint,yourcomfortis the
bestguide.Youcannotdepend ontable top or wall hungdial
gauges.
3. How long will It take my humidifier to build up the
humidity In my home?
Muchdependsonthe outsidetemperature,timeofyear,home
construction,and howdriedoutthe homehasbecome.Insoma
cases,it may take aweekor mare.
4. What are some of the common things that cause higher
then average sir leakage In the home, therefore causing
low humidity?
A. Jalousiewindows
B. Openfireplacedampers
C. Cracksaroundwindows end doors
D. Opendoorsendwindows
E. Unusuallylarge atticorfoundationvents
F. Rangehoodsand bathfans
5. Whet else causes static shock besides low humidity?
Some typesofcarpetstend to create morestaticthan others.
While the properhumiditylevel willreducethe staticlevel, it
may noteliminatestaticentirely.
6. What Is the safe humidity level for my home?
In ordertodeterminethe safe relativehumidityforhomesex-
posedtovariouslowoutsidetemperatures,NESCA*conducted
tests and publishedrecommendedhumiditylevelsfor various
outdoortemperatures.These are shown in the chart. These
levelshelppreventdamage to your homesuch as water run-
ningdownthewallsor evenbuildingupinsidethe walls.
The safeindoorrelativehumiditypementageisnota fixednum-
ber butwill increaseor decreaseas theoutdoortemperatures
riseorfall.
Outside Temperatures
-10° F
0° F
10° F
20° F
30° F
*NESCA- Ndonal EnvironmentalSystemsContractorsAuociation.
MaximumSafe Recommended
Indoor RelativeHumidity
20%
25%
30%
35%
35%
3
selecting a location
Consider these points as you choose the location for your
humidifier.
Locate humidifieronsupplyair plenum(Fig. 1) or returnair ple-
num.Ifthehumidifierisinstalledonthe rstumairplenum,the flex-
iblehose, roundopening, isconnected to the supplyairplenum.
If furnace is equipped with air conditioning, humidifier should be
mounted above or at slope side of "A" coil to avoid possible splash-
ing (Fig. 2) of water.
Humidifiershouldbe installedsothat ifthe humidifieroranyother
connectionsshouldleak,the resulting flowofwaterwillnotcause
damage.Undernocondition isSears and the manufacturertobe
heldliablefor any waterdamage in connection withthishumidi-
fier.Never installhumidifierinattic orcrawlspacewherefreezing
may occuror leaking will causewater damage.
If holes between supplyair plenum and return air plenum must
be locatedmore than 40 inchesapart (Fig. 1), standard6 inch
roundpipe and fittings(not supplied)may be used, or an 8 foot
sectionofflexibletube No. 28115205 maybe pumhasedthrough
the SearspartsdepartmenLMaterialsneededforthistypeinstal-
lationare availableat Seam.
installation
The humidifierisshippedwiththe block-offpanel on the
rightside(Fig.3).This issuitableforinstallationasshown
in Fig. 1, above. If thisis suitablefor yourinstallation,
removepartsas shownunderDISASSEMBLY.
If you require the block-off panel on the left side (Fig. 4),
start with DISASSEMBLY then remove block-offpanetfrom
dghtflange and installwith the same screws on leftflange.
16 inch minimum
40 inch maximum using flex
hose provided*
• Purchaseadditional
hosefo_greaterspans.
ReturnAir
Plenum
PlaceHumidifier
SupplyAi
Plenum
Air ConditionerCoil
AS SHIPPED
LeftHand Flange
Block-Off
Panel
Fumac_
Duct
AS CONVI=HTI=U
RightHandFlange
Block-Off
Panel
FIBER PLENUM DUCTS
NOTE: The mountingscrewssuppliedere forstan-
dard installationonsh_t metalplenumducts.
If you have fiber plenum ducts, install the hu-
midifierand components withthru-belts,nuts,and
washers (not supplied).(This fiber duct installa-
tion hardware is not supplied and must be pur-
chased from youlocal hardware store.)
venteye injurywheninstallinghumidifier.
CAUTION: Safetyglassesshouldbe wornto pre-
disassembly
1.Takeofffront panel by slidingpanelup and pullingoutat
the bottom.
2. Removecorrugated spacer and by.peesbootwhich con-
talnsdamper,collar &flextubeandtubedamp.
3. Remove mediapad by liftingbottom edgeup slightlyand
pullingout.
BypassFlange
BypassFlange
Cese/umemUy