Kenmore 303.147012 Owner's Manual

Kenmore 2700
17 GALLON
CENTRAL HUMIDIFIER
Installation
Maintenance Repair Parts
Troubleshooting
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
THANK YOU!
Thankyouforselectinga Sears Humidifier.Itwillprovideyearsof serviceif yougiveit a littlecare.
UNDERSTANDING HUMIDITY Humiditycan be puzzling. It cannot be seen, heard, touched,
smelledortasted. Many peopledo notunderstandwhata humidi- fierwillorwill notdo.
Probablythe bestway tojudgewhetherthe humidityistoo high,
toolowor aboutrightisto watchyourwindows.Ifthey areheavily fogged you mostlikelyhave too much. Ifthere is nomoistureon
TYPICAL QUESTIONS ASKED
them at all, especiallyinthe corners,you have too little.(NOTE:
Moisturewill notnormallyformonthermopaneor whenstormwin.
dowsare used.) ff there issome moistureinthe windowcorners
andalongtheedges,thehumidityisjustabout right.Thisisa good role of thumb, it you do not have an expensivepiece of testing equipment.Yourcomfortis anothergoodcheck.
1. Why do moisture requirements vary from home to home? Requirementsdepend onthe amount anddrynessof airto be
humidified.The largerand morelooselyconstructedthe home,
the greaterthe quantityof moisture required.
2. How can I best check my home's relative humidity? Firstgive your humidifiertime to buildup the humidityto an
acceptablelevel.Instrumentsare availabletomeasurerelative humidity,but from a practicalstandpoint,yourcomfortis the bestguide.Youcannotdepend ontable top or wall hungdial gauges.
3. How long will It take my humidifier to build up the humidity In my home?
Muchdependsonthe outsidetemperature,timeofyear,home construction,and howdriedoutthe homehasbecome.Insoma cases,it may take aweekor mare.
4. What are some of the common things that cause higher
then average sir leakage In the home, therefore causing
low humidity? A. Jalousiewindows
B. Openfireplacedampers C. Cracksaroundwindows end doors
D. Opendoorsendwindows
E. Unusuallylarge atticorfoundationvents F. Rangehoodsand bathfans
5. Whet else causes static shock besides low humidity? Some typesofcarpetstend to create morestaticthan others.
While the properhumiditylevel willreducethe staticlevel, it
may noteliminatestaticentirely.
6. What Is the safe humidity level for my home?
In ordertodeterminethe safe relativehumidityforhomesex-
posedtovariouslowoutsidetemperatures,NESCA*conducted tests and publishedrecommendedhumiditylevelsfor various
outdoortemperatures.These are shown in the chart. These levelshelppreventdamage to your homesuch as water run- ningdownthewallsor evenbuildingupinsidethe walls.
The safeindoorrelativehumiditypementageisnota fixednum-
ber butwill increaseor decreaseas theoutdoortemperatures riseorfall.
Outside Temperatures
-10° F 0° F
10° F
20° F 30° F
*NESCA- Ndonal EnvironmentalSystemsContractorsAuociation.
MaximumSafe Recommended
Indoor RelativeHumidity
20% 25% 30% 35%
35%
3
selecting a location
Consider these points as you choose the location for your humidifier.
Locate humidifieronsupplyair plenum(Fig. 1) or returnair ple- num.Ifthehumidifierisinstalledonthe rstumairplenum,the flex- iblehose, roundopening, isconnected to the supplyairplenum.
If furnace is equipped with air conditioning, humidifier should be
mounted above or at slope side of "A" coil to avoid possible splash- ing (Fig. 2) of water.
Humidifiershouldbe installedsothat ifthe humidifieroranyother connectionsshouldleak,the resulting flowofwaterwillnotcause damage.Undernocondition isSears and the manufacturertobe heldliablefor any waterdamage in connection withthishumidi- fier.Never installhumidifierinattic orcrawlspacewherefreezing
may occuror leaking will causewater damage.
If holes between supplyair plenum and return air plenum must
be locatedmore than 40 inchesapart (Fig. 1), standard6 inch roundpipe and fittings(not supplied)may be used, or an 8 foot
sectionofflexibletube No. 28115205 maybe pumhasedthrough
the SearspartsdepartmenLMaterialsneededforthistypeinstal-
lationare availableat Seam.
installation
The humidifierisshippedwiththe block-offpanel on the rightside(Fig.3).This issuitableforinstallationasshown
in Fig. 1, above. If thisis suitablefor yourinstallation, removepartsas shownunderDISASSEMBLY.
If you require the block-off panel on the left side (Fig. 4),
start with DISASSEMBLY then remove block-offpanetfrom
dghtflange and installwith the same screws on leftflange.
16 inch minimum
40 inch maximum using flex
hose provided*
Purchaseadditional
hosefo_greaterspans.
ReturnAir Plenum
PlaceHumidifier
SupplyAi
Plenum
Air ConditionerCoil
AS SHIPPED LeftHand Flange
Block-Off
Panel
Fumac_
Duct
AS CONVI=HTI=U
RightHandFlange
Block-Off
Panel
FIBER PLENUM DUCTS
NOTE: The mountingscrewssuppliedere forstan-
dard installationonsh_t metalplenumducts.
If you have fiber plenum ducts, install the hu- midifierand components withthru-belts,nuts,and washers (not supplied).(This fiber duct installa- tion hardware is not supplied and must be pur- chased from youlocal hardware store.)
venteye injurywheninstallinghumidifier.
CAUTION: Safetyglassesshouldbe wornto pre-
disassembly
1.Takeofffront panel by slidingpanelup and pullingoutat
the bottom.
2. Removecorrugated spacer and by.peesbootwhich con- talnsdamper,collar &flextubeandtubedamp.
3. Remove mediapad by liftingbottom edgeup slightlyand pullingout.
BypassFlange
BypassFlange
Cese/umemUy
Loading...