Kenmore 153.336161, 153.336261, 153.336301 HA, 153.336361, 153.336401 HA Owner's Manual

...
Owner's Manual
POWER MISER TM6
GAS WATER HEATER
FOR POTABLE WATER HEATING ONLY.
NOT SUITABLE FOR SPACE HEATING.
NOT FOR USE IN MOBILE HOMES.
MODEL NO.
153.336301 HA
153.336401 HA
153.336501 HA
30 Gallon Short 40 Gallon Short
30 Gallon High Altitude 30 Gallon
40 Gallon High Altitude 40 Gallon
50 Gallon High Altitude 50 Gallon
30 Gallon Propane (LP.)
40 Gallon Propane (L.P.) High Altitude
40 Gallon Propane (LP.)
50 Gallon Propane (L.P.) High Altitude
50 Gallon Propane (L.P.)
Safety Instruction
Installation
Operation
Care and Maintenance
Troubleshooting
Parts List
For Your Safety
ANODORANT ISADDEDTOTH EGAS USEDBYTHISWATERHEATER.
C3 Technology TM Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals
with the accidental or unintended ignition of flammable vapors, such as those
emitted by gasoline.
Read and understand instruction manual and safety messages
before installing, operating or
servicing this water heater.
Failure to follow instructions and safety messages could result in
death or serious injury. Instruction manual must remain
with water heater.
Si no puede leer o entender el ingles y necesita el manual instructive y/o etiquetas ee espaSol puede obtenerlos IIamando aI
1-800-821-2017. NO TRATE DE INSTALAR O OPERAR ESTE CALENTADOR DE AGUA si no entiende la informacibnen las etiquetas
o en el manual instructivo. No hacer case de esta adver[eecia podria resultar en la MU ERTE O GRAVES LESION ES CORPORALES.
WARNING: If the information in these
instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
-- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this orany other appliance.
-- WHAT TO DO IF YOU SMELL GAS:
Do nottryto light anyappliance,
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
--Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A
PART NO. 184231-000
PRINTED IN THE U.S.A 0204 www.sears.com SUPERSEDES PART NO. 184482-000
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and
others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very
important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you
to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, could result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result
in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result
in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, could result
in property damage.
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.
IMPORTANT DEFINITIONS
Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also
offer service and inspection of appliances within the building.
© Sears, Roebuck and Co.
2
Readandunderstandinstruction manualandsafetymessages
beforeinstalling,operatingor
servicingthiswaterheater
Failuretofollowinstructionsand safetymessagescouldresultin
deathorseriousinjury. Instructionmanualmustremain
withwaterheater.
Watertemperatureover125°F (52°C)cancausesevereburns instantlyresultinginsevereinjury
ordeath.
Children,the elderly,andthe physicallyor mentallydisabled
areathighestriskforscaldinjury.
Feel water before bathing or showering.
Temperature limiting valves are available.
Read instruction manual for safe
temperature setting
Fire or Explosion Hazard
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
Avoid all ignition sources if you smell LP gas. Do not expose water heater control to excessive gas
pressure. Use only gas shown on rating plate.
Maintain required clearances to combustibles. Keep ignition sources away from faucets after
,, extended penod of non-use.
Read instruction manual before
installing, using or servicing
Fire Hazard
For continued protection against risk of fire:
Do not install water heater on carpeted floor.
Do not operate water heater if
, __ , flood damaged.
_x.,
Explosion Hazard
Overheated water can cause watertank explosion
Properly sized temperature
and pressure relief valve must be installed in opening provided.
Breathing Hazard - Carbon Monoxide Gas
Install vent system in accordance with codes
Do not operate water heater if flood damaged.
High altitude orifice mustbe installed for operation above 3,300 feet (1,006 m) (or above 5,500 (1,676 m) feet for high altitude models)
Do not operate if soot buildup.
Do not obstruct water heater air intake with insulating jacket.
Do not place chemical vapor emitting products near water heater.
Gas and carbon monoxide detectors are available
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
Improper installation and use may result
in property damage.
Do not operate water heater if flood damaged.
Inspect and replace anode
Install in location with drainage.
Fill tank with water before operation.
Be alert for thermal expansion Refer to instruction manual for installation and service.
3
SAFE INSTALLATION, USE AND SERVICE ................................................................................................. 2
SAFETY PRECAUTIONS .............................................................................................................................. 3
TABLE OF CONTENTS ................................................................................................................................ 4
CUSTOMER RESPONSIBILITIES ................................................................................................................ 5
PRODUCT SPECIFICATIONS ...................................................................................................................... 5
MATERIALS AND BASIC TOOLS NEEDED ................................................................................................. 6
Material Needed ...................................................................................................................................................... 6
Basic Tools ............................................................................................................................................................. 6
TYPICAL INSTALLATION ............................................................................................................................... 7
INSTALLATION INSTRUCTIONS ............................................................................................................... 8-16
Removing the Old Water Heater .............................................................................................................................. 8
Facts to Consider About the Location ................................................................................................................ 9-10
Insulation Jackets ................................................................................................................................................. 10
Combustion Air and Ventilation Appliances
in Unconfined Spaces ............................................................................................................................................ 10
Combustion Air and Ventilation Appliances
in Confined Spaces ........................................................................................................................................... 11-12
Water Piping .................................................................................................................................................... 12-13
Temperature Pressure Relief Valve .................................................................................................................... 13-14
Filling the Water Heater ......................................................................................................................................... 14
Venting ............................................................................................................................................................. 14-15
Gas Piping ....................................................................................................................................................... 15-16
Sediment Trap .................................................................................................................................................. 16-17
OPERATING INSTRUCTIONS ................................................................................................................ 18-19
Lighting & Operating Label .................................................................................................................................... 18
Temperature Regulation ......................................................................................................................................... 19
SERVICE AND ADJUSTMENT ............................................................................................................... 20-22
Tank (Sediment) Cleaning ...................................................................................................................................... 20
Venting System Inspection .................................................................................................................................... 20
Burner Inspection .................................................................................................................................................. 20
Burner Cleaning ..................................................................................................................................................... 20
Housekeeping .................................................................................................................................................. 20-21
Anode Rod Inspection ........................................................................................................................................... 21
Temperature-Pressure Relief Valve Operation ........................................................................................................ 21
Draining ............................................................................................................................................................ 21-22
Drain Valve Washer Replacement .......................................................................................................................... 22
Service .................................................................................................................................................................. 22
TROUBLESHOOTING GUIDE ................................................................................................................ 23-26
Start Up Conditions .............................................................................................................................................................23-28
Thermal Expansion ........................................................................................................................................... 23
Strange Sounds ............................................................................................................................................... 23
Draft Hood Operation ................................................................................................................................... 23-24
Condensation ................................................................................................................................................... 24
Smoke/Odor ..................................................................................................................................................... 24
Operational Conditions ..................................................................................................................................... 24-25
Smelly Odor ..................................................................................................................................................... 24
Air in Hot Water Faucets .................................................................................................................................. 25
High Temperature Shut-Off System .................................................................................................................. 24
Leakage Checkpoints ....................................................................................................................................... 25
Troubleshooting Items ........................................................................................................................................... 26
NOTES .................................................................................................................................................... 27-28
PARTS ORDER LIST ............................................................................................................................. 29-31
WARRANTY ................................................................................................................................................ 32
Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble
free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®. They will arrange for prompt, quality installation by Sears
authorized contractors.
Abbreviations Found In This Instruction Manual:
CSA - Canadian Standards Association
ANSI - American National Standards Institute NFPA - National Fire Protection Association
ASME - American Society of Mechanical Engineers GAMA - Gas Appliance Manufacturers Association
This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 CSA 4.1
(current edition).
Read the"Safety Precautions" section, page 3 of this manual
first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE A'n'EMPTING
TO INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following: In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley
Rd, Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.
Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See
figure 1.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.
For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00.
Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
RECOVERY MINIMUM DIMENSIONS
TANK TYPE RATE GALS. VENT PIPE DIAMETER IN INCHES (mm)
MODEL CAPACITY OF BTU PER HOUR INCHES INCHES HEIGHT TO
NUMBER IN GALS (LTRS) GAS RATE @ 90°F RISE (mm) (mm) JACKETTOP
153336161 30 (114) NATURAL 32,000 32.8 3" (76) or 4" (102) 18 1/2" (470) 433/4" (1,111)
153.336261 40 (151) NATURAL 35,500 36.3 3" (76) or 4" (102) 20" (508) 47 1/4" (1,200)
153.336301 HA 30(114) NATURAL 35,500 36.3 3"(76) 16"(406) 571/2"(1,461)
153.336361 30 (114) NATURAL 35,500 36.3 3" (76) 16" (406) 57 1/2" (1,461)
153.336401 HA 40 (151) NATURAL 35,500 36.3 3" (76) 18 1/2" (470) 55 1/2" (1,410)
153.336465 40(151) NATURAL 35,500 36.3 3"(76) 181/2"(470) 551/2"(1,410)
153.336501 HA 50 (189) NATURAL 35,500 36.3 3" (76) 20" (508) 56 1/2" (1,435)
153.336565 50 (189) NATURAL 35,500 36.3 3" (76) 20" (508) 56 1/2" (1,435)
153.336761 30(114) PROPANE 35,500 36.3 3"(76) 16"(406) 571/2"(1,461)
153.336801 HA 40(151) PROPANE 35,500 36.3 3"(76) 181/2"(470) 551/2"(1,410)
153.336861 40(151) PROPANE 35,500 36.3 3"(76) 181/2"(470) 551/2"(1,410)
153.336901 HA 50 (189) PROPANE 35,500 36.3 3" (76) 20" (508) 56 1/2" (1,435)
153.336961 50 (189) PROPANE 35,500 36.3 3" (76) 20" (508) 56 1/2" (1,435)
Materials Needed
To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.
WATER HEATER _ _ '_
INSTALLATION ......
K,Tw,THPLEX,SLE
CONNECTORS
FOR 3/4" (19,05 mm)
OR t/2" (12.7 mm) THREADED OR
COPPER PLUMBING
FLEXIBLE WATER HEATER GAS CONNECTOR WITH FITTINGS
DRAIN PANS AVAILABLE IN 20" (508 ram) DIAMETER FOR WATER HEATERS
HAVING A DIAMETER 18" (457 ram) OR
LESS, 24" (610ram) DIAMETER FOR
WATER HEATERS HAVING A DIAMETER 22" (859 ram) OR LESS AND AVAILABLE
IN 28" (711 ram) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 26"
(660 mm) OR LESS
WATER HEATER HEAT TRAPSHELPREDUCE REATLOSSDUETO
THERMALSIPHONING
EXPANSION TAN KS FOR THERMAL EXPANSION
CON DITIONS AVAILABLE IN 2 GALLONS (7.6 LITERS) AND 5 GALLONS (18.9 LITERS)
CAPACITY THROUGH LOCAL SEARS STORE OR
SERVICE CENTER
Basic Tools
You may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local
Sears Store.
Pipe Wrenches (2) 14" (356 mm) _FIFT======_
Screwdriver Tin Snips
6' (1.82 m) Tape or Folding Ruler Garden Hose
Drill Pipe Dope or Teflon Tape DRILL
SLOT-HEAD SCREWDRIVER
PHILLIPS SCREWDRIVER
ROLL OF TEFLON
TAPE (USE ONLY ON
WATER HEATER
CONNECTIONS)
TIN SNIPS
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WATER AND GAS
CONNECTIONS
GARDENHOSE 6 FOOTTAPE PIPE WRENCH
Additional Tools Needed When Sweat Soldering
Tubing Cutters or Hacksaw Propane Tank
Soft Solder Solder Flux
Emery Cloth Wire Brushes
TUBING CUTTER
PROPANE
TORCH
HACKSAW
ROLL OF
EMERY CLOTH
3/4" (19 ram) WIRE BRUSH
1/2" (13 mm) WIRE BRUSH
ROLL OF LEAD-FREE SOLDER
SOFT SOLDER FLUX
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe
B Draft Hood C Anode
D Hot Water Outlet E Outlet
F Flexible Water Connections
G Gas Supply H Manual Gas Shut-off Valve
I Ground Joint Union
J Drip Leg (Sediment Trap) K Inner Door
L Outer door
M Union
N Inlet Water Shut-off Valve
O Cold Water Inlet
P Inlet DipTube
Q Temperature-Pressure Relief Valve
R Rating Plate
S Flue Baffle
T Thermostat
U Drain Valve V Pilot and Main Burner
W Flue
X Drain Pan
Y Thermostat Shield (optional) Z Piezo Igniter
AA Air Intake Screen
* INSTALL INACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT TERMINATION
ON ROOF
INSTALL THERMAL EXPANSION
TANK OR DEVICE IF WATER
HEATER IS INSTALLED IN A
CLOSED WATER SYSTEM
B
S
W
V
VACUUM RELIEF
VALVE
=INSTALLPER
LOCALCODES
Q
jR YI THERMOSTAT
SHIELD
(OPTIONAL)
X
AA
* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
RGURE1,
7
(T) THERMOSTAT
GAS CONTROL KNOB
I
WATER TEMPERATURE
(ADJUSTING DIAL)
"OFF .... PILOT .... ON" I
POSITION POSITION POSITION
"TOPVIEW
(V) PILOT & MAIN BURNER
BURNER TUBE
/
THERMOCOUPLE
MAIN BURNER
PILOT TUBING
THERMOCOUPLB
TCO
-_- IGNITER ROD
\
\ PILOT BURNER
Removing the Old Water Heater
FIGURE2,
Q Turn "OFF" the gas supply to the
water heater.
If the main gas line Shut-off valve
serving all gas appliances is
used, also shut "OFF" the gas at
each appliance. Leave all gas appliances shut "OFF" until the water heater installation is
completed, see Figures 2 and 3.
RGURE3,
(_) Turn water supply to
LLOF Ell the the
water heater at the water shut off valve or water meter. Some
installations require that the water be turned off to the entire house,
see Figures 2 and 4.
RGURE4.
(_Check again to make sure the gas supply is "OFF" to the
water heater. Then disconnect the gas supply connection from the gas control valve.
Burn hazard
Hotwater discharge.
Keep hands clear of drain valve discharge.
(_ Attach hose to the water heater
a
drain valve and put the other end
in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will
relieve pressure in the water
heater and speed draining. The water passing out of the drain valve
may be extremely hot. To avoid
being scalded, make sure all connections are tight and that the water flow is directed away from
any person, see Figures 2 and 5.
RGURE5,
(_ Disconnect the vent from the draft hood where itconnects
pipe
to the water heater. In most installations the vent pipe can
be lifted off after any screw or other attached devices are
removed. Dispose of the draft hood. The new water heater
has a draft hood which must be used for proper operation.
Q Ifyou have copper piping to the water heater, the two copper
water pipes can be cut with a hacksaw approximately four
inches away from where they connect to the water heater, see Figure 6. This will avoid cutting off pipes too short. Additional cuts can be made later if necessary. Disconnect the temperature-pressure relief valve drain line. When the
water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now
completely disconnected and ready to be removed.
FIGURE&
If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each
line. Also disconnect the piping remaining to the water heater, see Figure 7. These pieces should be saved since they may
be needed when reconnecting the new water heater.
Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is
now completely disconnected and ready to be removed.
Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could cause staining.
FIGURE 7,
Facts to Consider About
the Location
Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for
the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation,
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed:
Select a location indoors as close as practical to the gas
vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system as possible.
Selected location must provide adequate clearances for
servicing and proper operation of the water heater.
Property Damage Hazard
Allwaterheaterseventuallyleak
Denotinstallwithoutadequatedrainage
Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan
should be installed under the water heater. Drain pans are available at your local Sears or hardware store. Such a drain pan must have a minimum length and width of at least 2 inches
(51 mm) greater that the water heater dimensions and must be piped to an adequate drain. The pan must not restrict
combustion air flow.
Fire or Explosion Hazard
heater's pilot light or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area.
Even though this water heater is a flammable vapors ignition
resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the
same vicinity or area containing a gas water heater or other open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.
I i_ Fire Hazard
For continued protection against risk of fire:
Do not install water heater on carpeted floor,
Do not operate water heater if
flood damaged.
This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2 mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may
result in a fire hazard.
Fire or Explosion Hazard
using or servicing water heater.
Improper use may result in fire or
explosion.
Maintain required clearances to combustibles.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance,
Avoid all ignition sources if you smell LP gas.
Do not expose water heater control to excessive gas pressure
Use only gas shown on rating plate.
Maintain required clearances to combustibles,
Keep ignition sources away from faucets after
,, extended period of non-use.
Read instruction manual before
installing, using or servicing
water heater.
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.):
Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and other substances such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water
Minimum clearances between the water heater and combustible
construction are 0 inch at the sides and rear, 4 inches
(102 mm) at the front, and 6 inches (153 mm) from the vent
pipe, see Figure 8. Clearance from the top of the jacket is 12
inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater.
TOP VIEW TOP VIEW
OF CLOSET OF CLOSET
WITHOUT DOOR WITH DOOR
I I 0" MIN. 4" MIN.
4 mm)
0" MIN.
RGURE&
9
Breathing Hazard - Carbon Monoxide Gas
Install water heater in accordance with the instruction manual and NFPA 54.
To avoid injury, combustion and ventilation air must be taken from
outdoors.
Do not place chemical vapor emitting products near water
heater.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
A gas water heater cannot operate properly without the correct amount of air for combustion, see Figure 9. Do not install in a confined area such as a closet, unless you provide air as shown
in the Locating The New Water Heatersectien. Never obstruct
the flew of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.
12" MAX. (30 cm)
4
VENTILATION
AIR
OPENING O
FRONT VIEW
OF DOOR
AIR DUCT
JL 12- MAX.
1' (s0cm)
FIGURE9.
If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation air be taken from outside these areas.
Propellants of aerosol sprays and volatile compounds,
(cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.
Insulation Blankets
Insulation blankets available to the general public for external
use on gas water heaters are net necessary with Kenmere products. The purpose of an insulation blanket is to reduce the standby heat less encountered with storage tank heaters. Your
Kenmere water heater meets or exceeds the National Appliance
Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket
unnecessary.
Breathing Hazard - Carbon Monoxide Gas
":_'-_ o(__:;'_;._, Do not obstruct water heater air ,,. ,,,.,. intake with insulating blanket.
_"ii_i _i_: ° Gas and carbon monoxide
"*',_;'--;.._I._,_ _ detectors are available.
" Install water heater in accordance
_Z_.:_l with the instruction manual.
Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual
_' WARNING
Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to fellow these instructions can restrict the air flew required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.
Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.
Do not cover the outer door, thermostat or temperature & pressure relief valve.
Do not allow insulation to come within 2" (50.8 mm) of the fleer to prevent blockage of combustion air flow to the burner.
Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.
Do obtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels.
Do inspect the insulation blanket frequently to make certain it does net sag, thereby obstructing combustion air flow.
10
Combustion Air and Ventilation for
Appliances Located in Unconfined Spaces
UNCONFINED SPACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 ms per kW) of the aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the appliances are installed, through openings net furnished with doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier, etc.), additional air may need to be provided using the methods
described in Combustion Air and Ventilation for Appliances
Located in Confined Spaces.