Kenmore 153.336162, POWER MISER 6, 153.336262, 153.336362, 153.336466 Owner's Manual

...
Owner’s Manual
POWER MISER™ 6
GAS WATER HEATER
FOR POT ABLE WA TER HEA TING ONL Y.
NOT SUITABLE FOR SPACE HEA TING .
NOT FOR USE IN MOBILE HOMES.
MODEL NO.
153.336162 30 Gallon Short
153.336262 40 Gallon Short
153.336362 30 Gal lo n
153.336466 40 Gal lo n
153.336566 50 Gal lo n
153.336762 30 Gallon Propane (L.P.)
153.336862 40 Gallon Propane (L.P.)
153.336962 50 Gallon Propane (L.P.)
• Safety Instructions
• Installation
• Operation
• Care and Maintenance
• Troubleshooting
• Parts List
C3 Technology® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED T O THE GAS USED BY THIS W ATER HEA TER.
ADVERTENCIA
Si no puede leer o entender el inglés y necesita el manual instructivo y/o etiquetas en español puede obtenerlos llamando al 1-800-821-2017. NO TRATE DE INSTALAR O OPERAR ESTE CALENTADOR DE AGUA si no entiende la información en las etiquetas o en el manual instructivo. No hacer caso de esta advertencia podría resultar en la MUERTE O GRA VES LESIONES CORPORALES.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A
PRINTED IN THE U.S.A 0705 PART NO. 184231-001
1www.sears.com
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently
DANGER
W ARNING
CAUTION
hazardous situation which, if not avoided, could result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.
symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.
IMPORTANT DEFINITIONS
Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.
© Sears, Roebuck and Co.
2
SAFETY PRECAUTIONS
3
TABLE OF CONTENTS
SAFE INST ALLA TION, USE AND SERVICE ................................................................................................. 2
SAFETY PRECAUTIONS.............................................................................................................................. 3
TABLE OF CONTENTS ................................................................................................................................ 4
CUSTOMER RESPONSIBILITIES ................................................................................................................ 5
PRODUCT SPECIFICA TIONS...................................................................................................................... 5
MA TERIALS AND BASIC T OOLS NEEDED ................................................................................................. 6
Material Needed ...................................................................................................................................................... 6
Basic Tools ............................................................................................................................................................. 6
TYPICAL INST ALLA TION............................................................................................................................... 7
INST ALLA TION INSTRUCTIONS...............................................................................................................8-16
Removing the Old Water Heater .............................................................................................................................. 8
Facts to Consider About the Location ................................................................................................................ 9-10
Insulation Jackets ................................................................................................................................................. 10
Combustion Air and V entilation Appliances
in Unconfined Spaces............................................................................................................................................ 10
Combustion Air and V entilation Appliances
in Confined Spaces ...........................................................................................................................................11-12
Water Piping .................................................................................................................................................... 12-13
T emperature Pressure Relief V alve.................................................................................................................... 13-14
Filling the Water Heater......................................................................................................................................... 14
Venting............................................................................................................................................................. 14-15
Gas Piping ....................................................................................................................................................... 15-16
Sediment Trap.................................................................................................................................................. 16-17
OPERATING INSTRUCTIONS................................................................................................................18-19
Lighting & Operating Label .................................................................................................................................... 18
T emperature Regulation ......................................................................................................................................... 19
SERVICE AND ADJUSTMENT ............................................................................................................... 20-22
T ank (Sediment) Cleaning...................................................................................................................................... 20
Venting System Inspection.................................................................................................................................... 20
Burner Inspection .................................................................................................................................................. 20
Burner Cleaning..................................................................................................................................................... 20
Housekeeping .................................................................................................................................................. 20-21
Anode Rod Inspection ........................................................................................................................................... 21
T emperature-Pressure Relief V alve Operation ........................................................................................................ 21
Draining............................................................................................................................................................ 21-22
Drain V alve Washer Replacement.......................................................................................................................... 22
Service .................................................................................................................................................................. 22
TROUBLESHOOTING GUIDE ................................................................................................................23-26
Start Up Conditions .............................................................................................................................................................23-25
Thermal Expansion........................................................................................................................................... 23
Strange Sounds ............................................................................................................................................... 23
Draft Hood Operation................................................................................................................................... 23-24
Condensation ................................................................................................................................................... 24
Smoke/Odor..................................................................................................................................................... 24
Operational Conditions ..................................................................................................................................... 24-25
Smelly Odor ..................................................................................................................................................... 24
Air in Hot Water Faucets.................................................................................................................................. 25
High T emperature Shut-Off System .................................................................................................................. 24
Leakage Checkpoints....................................................................................................................................... 25
Troubleshooting Items ........................................................................................................................................... 26
NOTES....................................................................................................................................................27-28
PARTS ORDER LIST .............................................................................................................................29-31
WARRANTY ................................................................................................................................................ 32
4
CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Kenmore water heater. Properly
installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME®. They will arrange for prompt, quality installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual:
CSA - Canadian Standards Association
ANSI - American National Standards Institute
NFPA - National Fire Protection Association
ASME - American Society of Mechanical Engineers
GAMA - Gas Appliance Manufacturers Association
• This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).
• Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE A TTEMPTING
TO INSTALL OR OPERA TE THE WA TER HEA TER.
• The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:
In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
• If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.
• Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.
Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.
• For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
• Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.
• Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
PRODUCT SPECIFICATIONS
RECOVERYRECOVERY
RECOVERY
RECOVERYRECOVERY
TT
ANKANK
T
ANK
TT
MODELMODEL
MODEL
MODELMODEL
NUMBER NUMBER
NUMBER
NUMBER NUMBER
153.336162 30 (114) NA TURAL 32,000 30.6 3" (76) or 4" (102) 18 1/2" (470) 43 3/4" (1,1 1 1)
153.336262 40 (151) NATURAL 35,500 35.4 3" (76) or 4" (102) 20" (508) 47 1/4" (1,200)
153.336362 30 (114) NA TURAL 35,500 34.9 3” (76) 16” (406) 57 1/2” (1,461)
153.336466 40 (151) NATURAL 35,500 35.4 3" (76) 18 1/2" (470) 55 1/2" (1,410)
153.336566 50 (189) NATURAL 35,500 35.4 3" (76) 20" (508) 56 1/2” (1,435)
153.336762 30 (114) PROPANE 35,500 34.9 3" (76) 16" (406) 57 1/2” (1,461)
153.336862 40 (151) PROPANE 35,500 35.4 3" (76) 18 1/2" (470) 55 1/2” (1,410)
153.336962 50 (189) PROPANE 35,500 35.4 3" (76) 20" (508) 56 1/2” (1,435)
CAPCAP
CAP
CAPCAP
IN GIN G
IN G
IN GIN G
ALAL
AL
ALAL
ANKANK
AA
CITYCITY
A
CITY
AA
CITYCITY
S (LS (L
S (L
S (LS (L
TRS)TRS)
TRS)
TRS)TRS)
TYPETYPE
TYPE
TYPETYPE
OFOF
OF
OFOF
GASGAS
GAS
GASGAS
INPUTINPUT
INPUT
INPUTINPUT
RARA
TETE
RA
TE
RARA
TETE
(Btu/hr)(Btu/hr)
(Btu/hr)
(Btu/hr)(Btu/hr)
RARA
TE GTE G
ALAL
RA
TE G
RARA
TE GTE G
PER HOURPER HOUR
PER HOUR
PER HOURPER HOUR
@ 90°F RISE@ 90°F RISE
@ 90°F RISE
@ 90°F RISE@ 90°F RISE
5
AL
ALAL
SS
S
SS
..
VENT PIPEVENT PIPE
.
VENT PIPE
..
VENT PIPEVENT PIPE
MINIMUMMINIMUM
MINIMUM
MINIMUMMINIMUM
INCHESINCHES
INCHES
INCHESINCHES
(mm)(mm)
(mm)
(mm)(mm)
DIAMETERDIAMETER
DIAMETER
DIAMETERDIAMETER
INCHESINCHES
INCHES
INCHESINCHES
(mm)(mm)
(mm)
(mm)(mm)
DIMENSIONSDIMENSIONS
DIMENSIONS
DIMENSIONSDIMENSIONS
IN INCHES (mm) IN INCHES (mm)
IN INCHES (mm)
IN INCHES (mm) IN INCHES (mm)
HEIGHT TO HEIGHT TO
HEIGHT TO
HEIGHT TO HEIGHT TO
JACKET TOJACKET TO
JACKET TOP
JACKET TOJACKET TO
MATERIALS AND BASIC TOOLS NEEDED
Materials Needed
To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.
EXPANSION T ANKS FOR THERMAL EXPANSION CONDITIONS AV AILABLE IN 2 GALLONS (7.6 LITERS) AND 5 GALLONS (18.9 LITERS) CAPACITY HROUGH LOCAL SEARS STORE OR SERVICE CENTER.
WA TER HEA TER INST ALLATION KIT WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) OR 1/2” (12.7 mm) THREADED OR COPPER PLUMBING AND FLEXIBLE WATER HEATER GAS CONNECT OR WITH FITTINGS.
Basic Tools
You may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local Sears Store.
• Pipe Wrenches (2) 14” (356 mm)
• Screwdriver
• Tin Snips
• 6’ (1.82 m) Tape or Folding Ruler
• Garden Hose
• Drill
• Pipe Dope or Teflon Tape
SLOT-HEAD SCREWDRIVER
DRILL
DRAIN PANS A V AILABLE IN 20” (508 mm) DIAMETER FOR WA TER HEA TERS HA VING A DIAMETER 18” (457 mm) OR LESS, 24” (610mm) DIAMETER FOR WATER HEATERS HA VING A DIAMETER 22” (559 mm) OR LESS AND A V AILABLE IN 28” (711 mm) DIAMETER FOR WA TER HEA TERS HA VING A DIAMETER 26” (660 mm) OR LESS.
Additional Tools Needed When Sweat Soldering
• Tubing Cutters or Hacksaw
• Propane Tank
• Soft Solder
• Solder Flux
• Emery Cloth
• Wire Brushes
TUBING CUTTER
PROPAN E
TORCH
PHILLIPS SCREWDRIVER
ROLL OF TEFLON
TAPE (USE ONL Y ON
WATER CONNECTIONS)
GARDEN HOSE
6 FOOT TA PE
TIN SNIPS
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WA TER AND GAS
CONNECTIONS
PIPE WRENCH
3/4” (19 mm) WIRE BRUSH
1/2” (13 mm) WIRE BRUSH
6
HACKSAW
ROLL OF
EMERY CLOTH
ROLL OF LEAD-FREE
SOFT SOLDER
SOLDER
FLUX
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A V ent Pipe B Draft Hood C Anode D Hot Water Outlet E Outlet
F Flexible Water Connections G Gas Supply H Manual Gas Shut-off Valve
I Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT TERMINATION
ON ROOF
J Drip Leg (Sediment Trap)
K Inner Door
L Outer door
M Union
N Inlet Water Shut-off Valve
O Cold Water Inlet
P Inlet Dip Tube
Q Temperature-Pressure Relief Valve
R Rating Plate
S Flue Baffle
T Thermostat U Drain Valve V Pilot and Main Burner
W Flue
X Drain Pan
Y Thermostat Shield (optional)
Z Piezo Igniter
AA Air Intake Screen
(T) THERMOSTA T
* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
Y
THERMOSTAT
(OPTIONAL)
COVER
(V) PILOT & MAIN BURNER
FIGURE 1.
7
INSTALLATION INSTRUCTIONS
Removing the Old Water Heater
FIGURE 2.
4. Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining. The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person, see Figures 2 and 5.
5. Disconnect the vent pipe from the draft hood where it connects to the water heater. In most installations the vent pipe can be lifted off after any screw or other attached devices are removed. Dispose of the draft hood. The new water heater has a draft hood which must be used for proper operation.
6. If you have copper piping to the water heater, the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater, see Figure 6. This will avoid cutting off pipes too short. Additional cuts can be made later if necessary. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed.
FIGURE 5.
1. Turn “OFF” the gas supply to the water heater.
If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 2 and 3.
2. Turn “OFF” the water supply to the water heater at the water shut off valve or water meter. Some installations require that the water be turned off to the entire house, see Figures 2 and 4.
3. Check again to make sure the gas supply is “OFF” to the water heater. Then disconnect the gas supply connection from the gas control valve.
FIGURE 3.
FIGURE 4.
FIGURE 6.
If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each line. Also disconnect the piping remaining to the water heater , see Figure 7. These pieces should be saved since they may be needed when reconnecting the new water heater. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining.
FIGURE 7.
8
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for
use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed:
• Select a location indoors as close as practical to the gas vent or chimney to which the water heater vent is going to be connected, and as centralized with the water piping system as possible.
• Selected location must provide adequate clearances for servicing and proper operation of the water heater.
Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow will not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local Sears or hardware store. Such a drain pan must have a minimum length and width of at least 2 inches (51 mm) greater that the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow.
• Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.
INST ALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.] and other substances such as adhesives, etc.) emit flammable vapors which can be ignited by a gas water heater’s pilot light or main burner. The resulting flashback and fire can cause death or serious burns to anyone in the area. Even though this water heater is a flammable vapors ignition resistant water heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable substances should never be stored or used in the same vicinity or area containing a gas water heater or other open flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.
Water heater life depends upon water quality, water pressure and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut­off device used in conjunction with a piped drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:
• Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected.
• Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan.
• Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.
This water heater must not be installed directly on carpeting. Carpeting must be protected by metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2 mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.
9
Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater.
FIGURE 8.
FIGURE 9.
If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken directly from outdoors (direct vent).
Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.
Insulation Blankets
Insulation blankets available to the general public for external use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.
A gas water heater cannot operate properly without the correct amount of air for combustion, see Figure 9. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. If you have any doubt s or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.
WARNING
Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.
10
Do not apply insulation to the top of the water heater, as this
will interfere with safe operation of the draft hood.
Do not cover the outer door, thermostat or temperature &
pressure relief valve.
Do not allow insulation to come within 2” (50.8 mm) of the
floor to prevent blockage of combustion air flow to the burner.
Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
commence within 12 inches (30 cm) of the top and one commencing within 12 inches (30 cm) of the bottom of the enclosures.
Do obtain new warning and instruction labels from Sears
for placement on the blanket directly over the existing labels.
Do inspect the insulation blanket frequently to make certain
it does not sag, thereby obstructing combustion air flow.
Combustion Air and V entilation for Appliances Located in Unconfined Spaces
UNCONFINED SP ACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier , etc.), additional air may need to be provided using the methods described in Combustion Air and Ventilation for Appliances Located in Confined Spaces.
Combustion Air and V entilation for Appliances Located in Confined Spaces
FIGURE 10.
B. ALL AIR FROM OUTDOORS: (See Figures 9, 1 1,12 and 13)
The confined space shall be provided with two permanent
openings, one commencing within 12 inches (30 cm) of the top and one commencing within 12 inches (30 cm) from the bottom of the enclosure. The openings shall communicate directly , or by ducts, with the outdoors or sp aces (crawl or attic) that freely communicate with the outdoors.
CONFINED SPACE is a space whose volume is less than
3
50 cubic feet per 1,000 Btu per hour (4.8 m
per kW) of the
aggregate input rating of all appliances installed in that space.
A. ALL AIR FROM INSIDE BUILDINGS:
(See Figure 9 on page 9 and Figure 10 below)
The confined space shall be provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space. The total input of all gas utilization equipment installed in the combined space shall be considered in making this determination. Each opening shall have a minimum free area of one square inch
2
per 1,000 Btu per hour (22 cm gas utilization equipment in the confined space, but not less than 100 square inches (645 cm
/kW) of the total input rating of all
2
). One opening shall
FIGURE 11.
• When directly communicating with the outdoors, each opening shall have a minimum free area of 1 square inch per 4,000 Btu per hour (5.5 cm
2
/kW) of total input rating of all equipment in the
enclosure, see Figure 12.
• When communicating with the outdoors through vertical ducts, each opening shall have a minimum free area of 1 square inch per 4,000 BTU per hour (5.5 cm
2
/kW) of total input rating of all equipment in the enclosure, see Figure 12.
11
FIGURE 12.
• When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour (11 cm2/kW) of total input rating of all equipment in the enclosure, see Figure 13.
• When ducts are used, they shall be of the same cross­sectional area as the free area of the openings to which they connect. The minimum short side dimension of rectangular air ducts shall not be less than 3 inches (76.2 mm), see Figure 13.
Water Piping
HOTTER WA TER CAN SCALD: Water heaters are intended to produce hot water . Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly , children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a *mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores, see Figure 14 below. Valves for reducing point of use temperature by mixing cold and hot water are also available.
installation of the valves. Before changing the factory setting on the thermostat, read the T emperature Regulation section in this manual.
Follow manufacturer’s instructions for
FIGURE 13.
• Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be smaller than 1/4 inch (6.4 mm) mesh. If the free area through a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation.
• Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment.
FIGURE 14.
12
This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance.
All piping components connected to this unit for space heating applications shall be suitable for use with potable water.
• Look at the top of the water heater. The cold water inlet is marked “COLD”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4” NPT threaded nipple. Using flexible connectors, connect the cold water pipe to the cold water inlet of the water heater.
Toxic chemicals, such as those used for boiler treatment shall not be introduced into this system.
Water supply systems may, because of such events as high line pressure, frequent cut-offs or the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The
temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable
condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank to relieve the pressure built by thermal expansion in the water system. Refer to the Thermal Expansion section under Troubleshooting Guide or contact local plumbing authority or local Sears Service Center on how to control this situation.
NOTE: This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater.
INSTALLA TION COMPLETED USING
INSTALLA TION KIT
NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when connected to copper pipe.
Figure 15 shows the typical attachment of the water piping to the water heater. The water heater is equipped with 3/4” NPT water connections.
NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It will harm the dip tube and damage the tank.
FIGURE 15.
T & P V alve and Pipe Insulation
Remove insulation for T & P valve and pipe connections from carton.
• Look at the top cover of the water heater. The water outlet is marked “HOT”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4” NPT threaded nipple. Using flexible connectors, connect the hot water pipe to the hot water outlet on the water heater.
FIGURE 15A.
Fit pipe insulation over the incoming cold water line and the hot water line. Make sure that the insulation is against the top cover of the heater.
13
Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve.
Secure all insulation using tape.
T emperature-Pressure Relief Valve
This heater is provided with a properly certified combination temperature - pressure relief valve by the manufacturer.
The valve is certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment as meeting the requirements for Relief Valves and Automatic Gas Shut-off Devices for Hot Water Supply Systems, ANSI Z21.22 and the code requirements of ASME.
If replaced, the valve must meet the requirements of local codes, but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035kPa) and a discharge capacity not less than the water heater input rate as shown on the model rating plate.
For safe operation of the water heater, the relief valve must not be removed from its designated opening nor plugged.
The temperature-pressure relief valve must be installed directly into the fitting of the water heater designed for the relief valve. Position the valve downward and provide tubing so that any discharge will exit only within 6 inches (153 mm) above, or at any distance below the structural floor, see Figure 16. Be cert ain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve.
FIGURE 16.
The Discharge Pipe:
• Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.
• Shall not be plugged or blocked.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.
• Shall terminate at an adequate drain.
• Shall not have any valve between the relief valve and tank.
No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6 inch air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.
14
The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.
Filling the Water Heater
Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. W ater must flow from the hot water faucet before turning “ON” gas to the water heater.
To fill the water heater with water:
• Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.
and mechanically actuated vent dampers). Before installation of any vent damper, consult your local Sears Service Center or the local gas supplier for further information.
To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be utilized. Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater. Consult your gas supplier if any such changes are planned. For replacement heater installations where using pre­existing venting, venting must be inspected for obstructions and if deterioration is present, venting must be replaced.
• Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when the water heater is in use.
• To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.
• Check all water piping and connections for leaks. Repair as needed.
Venting
VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.
Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning.
Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically
For proper venting in certain installations, a larger diameter vent pipe may be necessary. Consult your local Sears Service Center or gas supplier to aid you in determining the proper venting for your water heater from the vent tables in the current edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.
Periodically check the venting system for signs of obstruction or deterioration and replace if needed.
The combustion and ventilation air flow must not be obstructed. The water heater with draft hood installed must be connected
to a chimney or listed vent pipe system, which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.
• For proper draft hood attachment, the draft hood legs may be angled slightly inward.
• Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit. Secure two legs to top with sheet metal screws.
• Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw, see Figure 17.
Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.
15
FIGURE 17.
The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter), see Figure 18.
Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
Gas Piping
FIGURE 18.
All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.
Vent pipes must be secured at each joint with sheet metal screws.
There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer’s clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the
vent pipe with mortar mix cement.
Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (3.5kPa) for natural and propane gas (L.P.). The minimum inlet gas pressure listed on the rating plate is for the purpose of input adjustment. valve is subjected to pressures exceeding 1/2 pound per square inch (3.5kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas.
If the main gas line shut-off serving all gas appliances is used, also turn “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is complete.
A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1/NFPA 54 and your gas supplier concerning pipe size.
There must be:
• A readily accessible manual shut off valve in the gas supply line serving the water heater, and
• A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.
If the gas control
Failure to have required clearances between vent piping and combustible material will result in a fire hazard.
• A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.
Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.
The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input.
16
Sediment Traps
Water heaters covered in this manual have been tested and approved for installation at elevations up to 7,700 feet (2,347m) above sea level. For installation above 7,700 feet (2,347 m), the water heater’s Btu input should be reduced at the rate of 4 percent for each 1,000 feet (305 m) above sea level which requires replacement of the burner orifice in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact your local gas supplier for further information.
Failure to replace the standard orifice with the proper high altitude orifice when installed at elevations above 7,700 feet (2,347 m) could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of the safe limits. This could result in serious injury or death. Contact your local gas supplier for any specific changes that may be required in your area.
Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the Gas Piping section. Refer to the current edition of th
e National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation, shown in Figures 19 and 20.
Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum (Propane [L.P.]) gases.
The appliance and its gas connection must be leak tested before placing the appliance in operation.
The appliance and its individual shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 pound per square inch (3.5 kPa).
Connecting the gas piping to the gas control valve of the water heater can be accomplished by either of the two methods shown in Figures 19 and 20.
FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.
FIGURE 20. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.
17
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH W ATER AND AIR PURGED FROM ALL LINES.
A. This appliance has a pilot which is lit by a piezo electric
gas ignition system. Do not open the inner door of the appliance and try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHA T TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
LIGHTING INSTRUCTIONS
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician . Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!
TOP KNOB
GAS CONTROL
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting (PILOT LIGHTING).
Turn thermostat dial fully clockwise
3. Push the gas control knob down slightly and turn clockwise
to “OFF”, SEE FIGURE “A”. NOTE: Knob CANNOT be turned from “PILOT” to “OFF” unless it is pushed down slightly . Do not force.
4. Remove the outer burner door located below the gas control.
5. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information
above on this label. If you don’t smell gas, go to next step.
6. This unit is equipped with a push button pilot igniter, which is used to light the pilot. Locate the igniter on the gas control.
7. Turn gas control knob counterclockwise SEE FIGURE “B”.
8. The pilot is located on the right side of the burner. It can be located by looking through the glass view port while pressing the piezo igniter button several times. Look for a spark at the pilot location, FIGURE “D”.
until it stops.
to “PILOT”,
TO TURN OFF GAS TO APPLIANCE
1. Set thermostat to the lowest setting (PILOT LIGHTING).
FIGURE “D”
9. Once the pilot has been found, push the gas knob all the way down. Immediately press the pilot igniter button rapidly (4) to (5) times. If the pilot will not light, repeat step (3) through (9).
10. Continue to hold the gas control knob down for about one (1) minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If it goes out, repeat step (3) through (9). It may take several minutes for air to clear the lines before the pilot will light.
• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob clockwise technician or gas supplier. SEE FIGURE “A”.
1 1. Once the pilot flame is established replace the outer burner
door.
12. At arms length away, turn gas control knob counterclockwise
13. Set thermostat to desired setting.
DANGER: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.
2. Push gas control knob down slightly and turn clockwise to “OFF”. Do not force. SEE FIGURE “A”.
to “OFF” and call your service
to “ON”. SEE FIGURE “C”.
18
Temperature Regulation
Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 30F° (16.7 C°) higher or lower at the point of use such as, bathtubs, showers, sink, etc.
Any water heater’s intended purpose is to heat water. Hot water is needed for cleansing, cleaning, and sanitizing (bodies, dishes, clothing). Untempered hot water can present a scald hazard. Depending on the time element, and the people involved (adults, children, elderly , infirm, etc.) scalding may occur at different temperatures.
THE WATER HEATER SHOULD BE LOCATED IN AN AREA WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS. IF A SUIT ABLE AREA IS NOT A VAILABLE, A COVER SHOULD BE INSTALLED OVER THE THERMOSTAT TO PREVENT TAMPERING. Suitable covers are available through the Sears Service Center.
Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or handicapped person unattended in a bathtub or shower.
NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended by most dishwasher manufacturers.
The thermostat of this water heater has been factory set at its lowest position (PILOT LIGHTING). It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury. The mark (
) indicative of approximately 120°F (49°C) is preferred starting point. Some states have a requirement for a lower setting.
Turn the water temperature dial clockwise ( ) to decrease the temperature, or counterclockwise ( ) to increase the temperature.
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.
HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these people or at the water heater . Mixing valves are available at plumbing supply or hardware stores. Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the Temperature Regulation section in this manual, see Figures 21 and 22.
FIGURE 21.
Temperature Time to Produce 2nd & 3rd
Settings Degree Burns on Adult Skin
VERY HOT= approx. 160°F (71°C)
C = approx. 150°F (66°C) About 1-1/2 seconds B = approx. 140°F (60°C) Less than 5 seconds A = approx. 130°F (54°C) About 30 seconds
= approx. 120°F (49°C) More than 5 minutes
LOW = approx. 80°F (27°C) - - - - - - - - - - - - - - - -
FIGURE 22.
About 1/2 second
19
SERVICE AND ADJUSTMENT
Tank (Sediment) Cleaning
Sediment build-up on the tank bottom may create varying amount of noise, and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag-Erad (part no. 23600) can be used to help remove the sediment deposits. This may be ordered from the Sears Service Center. For ordering, refer to the Parts Order List section.
Vent System Inspection
• Flue gases may escape if vent pipe is not connected.
• Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
• Do not store corrosive chemicals in vicinity of water heater.
Burner Inspection
Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions
can cause DEATH, SERIOUS BODIL Y INJURY , OR PROPERT Y DAMAGE. Contact a Sears Service Center to replace a flooded water heater. Do not attempt to
replaced! At least once a year a visual inspection should be made of the
main burner and pilot burner, see Figure 23. Y ou should check for sooting. Soot is not normal and will imp air
proper combustion. Soot build-up indicates a problem that requires correction
before further use. Turn “OFF” gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.
repair the unit! It must be
which
• Chemical corrosion of flue and vent system can cause serious injury or death
At least once a year a visual inspection should be made of the venting system. You should look for:
• Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.
• Damage or deterioration which could cause improper venting or leakage of combustion products.
• Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
If when inspecting the vent system you find sooting or deterioration, something is wrong. Call the local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.
FIGURE 23.
Burner Cleaning
In the event your burner needs cleaning, following these instructions:
If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is depressed slightly. DO NOT FORCE.
The burner needs to be removed for cleaning. Call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned.
20
) to the “OFF” position,
Housekeeping
T emperature-Pressure Relief Valve Operation
V acuum around base of water heater for dust, dirt, and lint on a regular basis.
AT LEAST ONCE EVERAT LEAST ONCE EVER
AT LEAST ONCE EVER
AT LEAST ONCE EVERAT LEAST ONCE EVER VISUAL INSPECTION SHOULD BE MADE OFVISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OF
VISUAL INSPECTION SHOULD BE MADE OFVISUAL INSPECTION SHOULD BE MADE OF THE THE
AIR INTAIR INT
THE
AIR INT
THE THE
AIR INTAIR INT
AA
CCUMULACCUMULA
A
CCUMULA
AA
CCUMULACCUMULA
AKE SCREENAKE SCREEN
AKE SCREEN
AKE SCREENAKE SCREEN
TIONS TIONS
TIONS
TIONS TIONS
ARE NOARE NO
ARE NO
ARE NOARE NO
Y SIX MONTHS Y SIX MONTHS
Y SIX MONTHS
Y SIX MONTHS Y SIX MONTHS
..
CLEAN IF LINT CLEAN IF LINT
.
CLEAN IF LINT
..
CLEAN IF LINT CLEAN IF LINT
TICEDTICED
TICED
TICEDTICED
..
.
..
AA
A
AA
The temperature-pressure relief valve must be manually operated at least once a year.
When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 24.
INSTALLED IN SUIT ABLE AREA: To insure sufficient ventilation and combustion air supply, proper clearances from the water heater must be maintained. See Facts to Consider About the Location section. Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater because they could catch on fire.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod deteriorates to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.
FIGURE 24.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.
If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult the Sears Service Center for further information. Do not plug the temperature-pressure relief valve.
Draining
Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/ or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by calling the Sears Service Center for an authorized contractor . At a minimum, the anode(s) should be checked annually after the warranty period.
The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
1. Turn the gas control knob to the “OFF” position.
21
2. CLOSE the cold water inlet valve to the water heater.
3. OPEN a nearby hot water faucet and leave open to allow for draining.
4. Connect a hose to the drain valve and terminate to an adequate drain.
5. OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.
5. Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.
6. Follow instructions in the Filling The Water Heater section.
7. Check for leaks.
8. Follow the lighting instructions in the Lighting section to restart the water heater.
6. CLOSE the drain valve.
7. Follow instructions in the Filling The Water heater section.
8. Follow the lighting instructions in the Lighting section to restart the water heater.
Drain Valve Washer Replacement
(See Figure 25)
1. Turn “OFF” gas supply to water heater.
2. Follow “Draining” instructions.
3. Turning counter clockwise ( the screw handle.
4. Remove the washer and put the new one in place.
), remove the hex cap below
FIGURE 25.
Service
Before calling for repair service, read the Start Up Conditions and Operational Conditions found in the T roubleshooting Guide of this manual.
If a condition persists or you are uncertain about the operation of the water heater, let the Sears Service Center check it out.
Contact Sears Service Center at:
®
1-800-4-MY-HOME
(1-800-469-4663).
22
TROUBLESHOOTING GUIDE
Start Up Conditions
Thermal Expansion
Water supply system may, because of such events as high line pressure, frequent cut-offs, and the effects of water hammer have installed devices such as pressure reducing valves, check valves, back flow preventers, etc., to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of water heater’s temperature-pressure relief valve is reached, the valve will relief the excess pressure. The
temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable
condition and must be corrected. It is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an expansion tank or device to relieve the pressure built by thermal expansion. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations, see Figure 26.
NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.
Thermal Expansion Tank Specifications
Tan k Dimensions Pipe
Model Capacity in Inches Fitting
Number In Gallons Diameter Length On Tank
153.331020 2 8 (203 mm) 12-3/4 (323 mm) 3/4” Male
153.331050 5 11 (279 mm) 14-3/4 (375 mm) 3/4” Male
Expansion Tank Sizing Chart
Inlet* Water Heater Capacity (Gallons)
Water
Pressure 30 40 50 66 80
Expansion 40psi 2 2 2 5 5
Tank 50psi 2 2 2 5 5
Capacity 60psi 2 2 5 5 5
Needed 70psi 2 2 5 5 5
80psi 2 5 5 5 5
*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.
FIGURE 26.
Strange Sounds
Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See Condensation section.
Draft Hood Operation
Check draft hood operation by performing a worst case depressurization of the building. With all doors and windows closed, and with all air handling equipment and exhaust fans operating such as furnaces, clothes dryers, range hoods and bathroom fans, a match flame should still be drawn into the draft hood of the water heater with its burner firing. If the flame
23
is not drawn toward the draft hood, shut off water heater and make necessary air supply changes to correct.
Condensation
from hydrogen sulfide gas dissolved in the water. The smell is the result of four factors which must all be present for the odor to develop:
• a concentration of sulfate in the supply water.
Whenever the water heater is filled with cold water, some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when:
• A new water heater is filled with cold water for the first time.
• Burning gas produces water vapor In water heaters, particularly high efficiency models where flue temperatures are lower.
• Large amounts of hot water are used in a short time and the refill water in the tank is very cold.
Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise.
Excessive condensation can cause pilot outage due to water running down the flue tube onto the main burner and putting out the pilot.
Because of the suddenness and amount of water, condensation water may be diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2 hours), the condition should disappear.
• little or no dissolved oxygen in the water.
• a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)
• an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active material, and then chlorinating the water heater tank and all hot water lines. Contact Sears Service for further information concerning an Anode Replacement Kit #9001453 and this Chlorination Treatment. Anode replacement and chlorination of the tank are not covered by the water heater’s limited warranty.
If the smelly water persists after the anode replacement and chlorination treatment, it may be necessary to chlorinate or aerate your water supply to eliminate the problem.
Do not remove the anode leaving the tank unprotected. By doing so, all warranty on the water heater tank is voided.
“AIR” In Hot Water Faucets
Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation. The water heater must be sized properly to meet the family’s demands for hot water including dishwashers, washing machines and shower heads.
Excessive condensation may be noticed during the winter and early spring months when incoming water temperatures are at their lowest.
Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor.
Smoke Odor
It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while.
Operational Conditions
Smelly Odor
In each water heater there is installed at least one anode rod
(see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell”. This odor is derived
HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these conditions, we recommend the hot water faucet, located farthest away, be opened for several minutes before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.
High T emperature Shut-Off System
This water heater is equipped with an automatic gas shutoff system. This system works when high water temperatures are present. Turn “OFF” the entire gas supply to the water heater. The high temperature shutof f is built into the gas control valve. It is non-resettable. If the high temperature shutoff activates, the gas control valve must be replaced. Contact your gas supplier.
24
Operational Conditions (Continued)
Leakage Checkpoints
Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater, see Figure 27.
A. Water at the draft hood is water vapor which has condensed
out of the combustion products. This is caused by a problem in the vent. Contact the gas utility.
B. *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
C. *The anode rod fitting may be leaking.
D. Small amounts of water from temperature-pressure relief
valve may be due to thermal expansion or high water pressure in your area.
E. *The temperature-pressure relief valve may be leaking at
the tank fitting.
FIGURE 27.
F. Water from a drain valve may be due to the valve being
slightly opened.
G. *The drain valve may be leaking at the tank fitting.
H. Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.
I. Water in the water heater bottom or on the floor may be from
condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken.
Leakage from other appliances, water lines, or ground seepage should also be checked.
* To check where threaded portion enters tank, insert cotton
swab between jacket opening and fitting. If cotton is wet, follow “Draining” instructions in the Periodic Maintenance section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow Filling the Water Heater instructions in the Installing the New Water Heater section.
25
TROUBLESHOOTING GUIDE (Continued)
These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME® (1-800-469-4663)
for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product.
Problem Cause Solution
Improperly sealed, hot or cold supply connection, Tighten threaded connections.
WA TER LEAKS
LEAKING T&P VALVE
SMELL Y ODORS
PILOT WILL NOT LIGHT of igniter wire.
relief valve, drain valve, or thermostat threads. Leakage from other appliances or water lines. Inspect other appliances near water heater. Condensation of flue products. Refer to CONDENSATION. Thermal expansion in closed water system. Install thermal expansion tank (DO NOT plug T&P valve). Improperly seated valve. Check relief valve for proper operation
(DO NOT plug T&P valve).
High sulfate or mineral content in water supply. Drain and flush heater thoroughly, then refill.
Bacteria in water supply. Chlorinate or aerate water supply. Gas control knob not positioned correctly. Refer to LIGHTING INSTRUCTIONS. Main gas supply off. Turn on main gas shutoff valve. Igniter tip more than 1/8" from pilot hood. Adjust igniter tip. Thermocouple malfunction. Replace pilot assembly. Thermocouple TCO malfunction. Replace pilot assembly . Melted insulation on igniter wire or shorting Contact Sears Service to determine cause.
High ambient room temperature. Contact Sears Service to determine cause.
Wire disconnected from spark igniter. Reconnect wire connector to spark igniter. Broken electrode or electrical wire. Replace pilot assembly. Piezo Igniter generator fails to operate or Replace Piezo Igniter generator. malfunctions. Thermocouple TCO malfunction. Replace pilot assembly . High ambient room temperature. Contact a service agency to
determine cause.
BURNER WILL NOT Dirty or clogged air intake screen. Clean and reinstall air intake screen.
STAY LIT Flame arrestor openings blocked. Contact Sears Service to
determine cause. Defective Gas Control. Replace Gas Control. Dirty pilot burner. Clean pilot assembly. Dirty or clogged air intake screen. Clean and reinstall air intake screen.
PILOT OUTAGE
NOT ENOUGH Low gas pressure. Contact your gas supplier.
HOT WA TER Incoming water is unusually cold. Allow more time for heater to re-heat.
WA TER T OO HOT Thermostat set too high. Refer to TEMPERA TURE REGULATION.
WA TER HEA TER SOUNDS Condensation dripping on burner. Refer to CONDENSATION.
SIZZLING - RUMBLING
SOOTING
VENT GAS ODORS
Thermocouple tip is not in contact with pilot flame. Insert thermocouple correctly. Thermocouple malfunction. Replace pilot assembly. Thermocouple TCO malfunction. Replace pilot assembly . Defective Gas Control. Replace Gas Control. Heater not lit or thermostat not on. Refer to LIGHTING INSTRUCTIONS. Thermostat set too low. Refer to TEMPERA TURE REGULATION. Heater undersized. Reduce hot water use.
Leaking hot water pipes or fixtures. Have plumber check and repair leaks. High temperature limit switch activated. Contact Sears Service to
determine cause.
Sediment or calcium in bottom of heater tank. Clean sediment from tank. Refer to DRAINING
instructions in Maintenance section of manual. Improper combustion. No adjustment available. Contact Sears Service
to determine cause. Lack of supply air. Improperly installed vent piping. Contact Sears Service to determine cause. Downdraft. Poor combustion.
26
NOTES:
27
NOTES:
28
P ARTS ORDER LIST
POWER MISER™ 6 GAS WATER HEATER
MODEL NO’S
153.336162 30 Gallon Short
153.336262 40 Gallon Short
153.336362 30 Gallon
BURNER ASSEMBL Y3
Model Numbers
Key No. Part Description 153.336162 153.336262 153.336362
1 Air Intake Screen 9003406 9003406 9003406 2 Anode Rod 9003888 9003889 9003889 3 Burner Assembly 9003477 9003485 9003442 4 Burner Head** 9003385 9003385 9003385 5 Burner Orifice** 9003478 (#38) 9003457 (#37) 9003443 (#36) 6 Burner Tube w/Rubber Boot** 9003391 9003391 9003390 7 Draft Hood 9003405 9003405 9003405 8 Drain Valve 9000058 9000058 9002402
9 Drain Valve Washer 9001584 9001584 9001584 10 Flue Baffle 9003999 9003480 9003969 1 1 Flue Restrictor 9003445 9003445 9000275 12 Gas Control Valve F145-1278 F145-1278 F145-1278 13 Inlet Tube 9003500 9003500 9003463
*14 Inlet Tube Gasket 9003981 9003981 9003981
15 Inner Door** 9003400 9003398 9003399
16 Inner Door Gasket 9003401 9003401 9003401
*17 Instruction Manual 184231-001 184231-001 184231-001
*18 Mag-Erad 23600 23600 23600
19 Nipple w/Heat Trap 9003719 9003719 9003719 20 Outer Door 9003545 9003545 9003545 21 Piezo Igniter w/Bracket 9003410 9003410 9003410 22 Pilot Assembly w/Grommet** 9003542 9003488 9003542 23 T & P Relief V alve 9000071 9000071 9000071 24 Temperature Adjustment Knob F145-1280 F145-1280 F145-1280 25 Viewport Assembly 9003414 9003414 9003414
* Not Shown. ** Includes Inner Door Gasket
Now that you have purchased your gas water heater, should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME all pertinent facts when you call or visit.
WHEN ORDERING REP AIR PAR TS, ALWA YS GIVE THE FOLLOWING INFORMA TION:
®
(1-800-469-4663). Be sure to provide
MODEL NUMBER
SERIAL NUMBER
TYPE GAS - NA TURAL OR PROP ANE (L.P .)
PART DESCRIPTION
THIS IS A REP AIR P ARTS LIST, NOT A P ACKING LIST.
29
P ARTS ORDER LIST
POWER MISER™ 6 GAS WATER HEATER
MODEL NO’S
153.336466 40 Gallon
153.336566 50 Gallon
BURNER ASSEMBL Y3
Model Numbers
Key No. Part Description 153.336466 153.336566
1 Air Intake Screen 9003406 9003406 2 Anode Rod 9003972 9003891 3 Burner Assembly 9003458 9003467 4 Burner Head** 9003385 9003385 5 Burner Orifice** 9003443 (#36) 9003443 (#36) 6 Burner Tube w/Rubber Boot** 9003391 9003389 7 Draft Hood 9003405 9003405 8 Drain Valve 9002402 9003482 9 Drain Valve W asher 9001584 9001584
10 Flue Baffle 9003970 9003989
1 1 Flue Restrictor 9000275 9000275 12 Gas Control Valve F145-1278 F145-1278 13 Inlet Tube 9003463 9003473
*14 Inlet Tube gasket 9003981 9003981
15 Inner Door** 9003400 9003398 16 Inner Door Gasket 9003401 9003401
*17 Instruction Manual 184231-001 184231-001 *18 Mag-Erad 23600 23600
19 Nipple w/Heat trap 9003719 9003719 20 Outer Door 9003545 9003545 21 Piezo Igniter w/Bracket 9003410 9003410 22 Pilot Assembly w/Grommet** 9003531 9003488 23 T & P Relief V alve 9000071 9000071 24 T emperature Adjustment Knob F145-1280 F145-1280 25 Viewport Assembly 9003414 9003414
* Not Shown. ** Includes Inner Door Gasket
Now that you have purchased your gas water heater, should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME all pertinent facts when you call or visit.
WHEN ORDERING REP AIR PAR TS, ALWA YS GIVE THE FOLLOWING INFORMATION:
®
(1-800-469-4663). Be sure to provide
MODEL NUMBER
SERIAL NUMBER
TYPE GAS - NA TURAL OR PROP ANE (L.P .)
PART DESCRIPTION
THIS IS A REP AIR P ARTS LIST, NOT A P ACKING LIST.
30
P ARTS ORDER LIST
POWER MISER™ 6 GAS WATER HEATER
MODEL NO’S
153.336762 30 Gallon Propane (L.P.)
153.336862 40 Gallon Propane (L.P.)
153.336962 50 Gallon Propane (L.P.)
BURNER ASSEMBL Y3
Model Numbers
Key No. Part Description 153.336762 153.336862 153.336962
1 Air Intake Screen 9003406 9003406 9003406 2 Anode Rod 9003889 9003972 9003891 3 Burner Assembly 9003451 9003460 9003565 4 Burner Head** 9003422 9003422 9003385
5 Burner Orifice** 9003453 (#51) 9003453 (#51) 9003453 (#51)
6 Burner Tube w/Rubber Boot** 9003454 9003392 9003389 7 Draft Hood 9003405 9003405 9003405 8 Drain Valve 9002402 9002402 9003482 9 Drain Valve Washer 9001584 9001584 9001584
10 Flue Baffle 9003969 9003970 9003989
1 1 Flue Restrictor 9000275 9000275 9000275 12 Gas Control Valve F145-1 279 F145-127 9 F145-1279 13 Inlet Tube 9003463 9003463 9003473
*14 Inlet Tube Gasket 9003981 9003981 9003981
15 Inner Door** 9003399 9003400 9003398
16 Inner Door Gasket 9003401 9003401 9003401
*17 Instruction Manual 184231-001 184231-001 184231-001 *18 Mag-Erad 23600 23600 23600
19 Nipple w/Heat Trap 9003719 9003719 9003719 20 Outer Door 9003545 9003545 9003545 21 Piezo Igniter w/Bracket 9003410 9003410 9003410 22 Pilot Assembly w/Grommet** 9003455 9003455 9004021 23 T & P Relief Valve 9000071 9000071 9000071 24 Temperature Adjustment Knob F145-1280 F145-1280 F145-1280 25 Viewport Assembly 9003414 9003414 9003414
* Not Shown. ** Includes Inner Door Gasket
Now that you have purchased your gas water heater, should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME all pertinent facts when you call or visit.
WHEN ORDERING REP AIR PA RTS, ALW AYS GIVE THE FOLLOWING INFORMA TION:
®
(1-800-469-4663). Be sure to provide
MODEL NUMBER
SERIAL NUMBER
TYPE GAS - NATURAL OR PROP ANE (L.P .)
PART DESCRIPTION
THIS IS A REP AIR P ARTS LIST, NOT A P ACKING LIST .
31
6 - YEAR LIMITED W ARRANTY ON WA TER HEATER
For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner’s manual instructions and all local applicable plumbing codes, Sears will:
1. Supply free water heater parts for those that are defective in material or workmanship.
2. Supply a free water heater for one that develops a leak. For the second through sixth year from the purchase date, you must pay the labor cost for installation of parts or water heater . For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for two years.
During the second year you must pay the labor cost for parts or water heater installation.
1 - YEAR EXCLUSIVE KENMORE LABOR WARRANTY
For the first year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for defective ones or a new water heater for one that develops a leak.
WARRANTY SER VICE
T o obtain warranty service, call 1-800-4-MY -HOME® (1-800-469-4663). This warranty applies only while this product is in use in the United States. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
SEARS, ROEBUCK AND CO., Dept.817WA, Hoffman Estates, IL 60179
The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Sears
warrants the installation. A charge will be made on service calls due to poor or incomplete installation. These include:
a. Adjusting thermostat c. Condensation b. Leaks in pipes or fittings
MASTER PROTECTION AGREEMENTS
Congratulations on making a smart purchase. Your new Kenmore product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That’s when having a Master Protection Agreement can save you money and aggravation.
Purchase a Master Protection Agreement now and protect yourself from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of your new product. Here’s what’s included in the Agreement:
Expert Service by our 12,000 professional repair specialist.
Unlimited service and no charge for parts and labor on all covered repairs.
“No-lemon” guarantee - replacement of your covered product if four or more product failures occur within twelve months.
Product replacement if your covered product can’t be fixed.
Annual Preventive Maintenance Check at your request - no extra charge.
Fast help by phone - phone support from a Sears technician on products requiring in-home repair , plus convenient repair scheduling.
Call 24 hours a day, 7 days a week (U.S.A. and Canada)
The model number of your water heater is found on the model rating plate on the front of the water heater.
Power surge protection against electrical damage due to power fluctuations.
®
Rental reimbursement if repair of your covered product takes longer than promised.
Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment on-line.
Sears has over 12,000 professional repair specialists, who have access to over 4.5 million quality parts and accessories. That’s the kind of professionalism you can count on to help prolong the life of your new purchase for years to come. Purchase your Master Protection Agreement today!
Some limitations and exclusions apply . For prices and additional information call 1-800-827-6655.
SEARS INST ALLATION SER VICE
For Sears professional Installation of home appliances, garage door openers, water heaters, and other major home items, in the U.S.A., call
1-800-4-MY-HOME
For in-home major brand repair service
1-800-4-MY-HOME
(1-800-469-4663)
www.sears.com
®
.
®
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A