Owner's Manuam
POWER MISERTM
ELECTRmC
WATER HEATER
FOR POTABLE WATER HEATING ONLY.
NOT SUITABLE FOR SPACE HEATING,
MODEL NO.
153.329262 38 Gallon Short
153.329263 38 Gallon Short
153.329360 30 Gallon
152.329361 30 Gallon
153.329460 40 Gallon
153.329461 40 Gallon
153.329560 55 Gallon
153.329561 55 Gallon
153.329660 66 Gallon
153.32966! 66 Gallon
153.329860 80 Gallon
153.329861 80 Gallon
9
USTED
GAMA certification applies to all residential electric water heaters
with capacities of 20 to 120 Gallons, Input rating of 12kW or
less at a voltage no greater than 250V.
o Safety _nstructions
o _nstaHation
o Operation
o Care and Maintenance
o Troubleshooting
o Parts List
Read and understand instruction
manual and safety messages
before installing, operating or
servicing this water heater.
Failure to follow instructions and
safety messages could result in
death or serious injury,
Instruction manual must remain
with water heater.
SAVE TNBS MANUAL FOR FUTURE REFERENCE,
Sears, Roebuck and Co., Hoffman Estates, _L 60179 U.S.A
PRINTED IN THE U.S.A 0205 _W_.Se_PS.CO[n PART NO. 184726-001

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safetyore[ated messages and instructions have been provided in this manual and on your own water heater to warn you
and others of a potential injury hazard. Read and obey aii safety messages and instructions throughout this manual it is very
important that the meaning of each safety message is understood by you and others who install, use or service this water
heater.
This is the safety alert symbol It is used to alert you
to potentiam personal injury hazards. Obey all safety
messages that folmow this symbom to avoid possible
injury or death.
DANGER indicates an imminentEy
hazardous situation which, if not avoided,
could resutt in death or injury.
WARNING indicates a potentially
hazardous situation which, if not avoided,
could result in death or injury.
CAUTtON indicates a potentially
hazardous situation which, if not avoided,
may result in minor or moderate injury.
CAUTION used without the safety alert
symbot indicates a potentially hazardous
situation which, if not avoided, could
result in property damage.
AH safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message
and how to avoid the risk of injury.
I_,_PORTANT DEFINITIONS
Sears Service Center: The Sears Service Center has the ability equivalent to a licensed tradesman in the fields of plumbing and
electrical work including a thorough understanding of the requirements of the National Electric Code as it relates to the installation
of electric water heaters. The Sears Service Center also has a thorough understanding of this instruction manual, and is able to
perform repairs strictly in accordance with the service guidelines provided by the manufacturer,

Readandunderstandinstruction
manualandsafetymessages
beforeinstalling,operatingor
servicingthiswaterheater.
Failuretofollowinstructionsand
safetymessagescouldresultin
deathorseriousinjury.
instructionmanualmustremain
withwaterheater.
Improper installation and use may result
in property damage.
Do not operate water heater if flood damaged.
Inspect and replace the anode as needed_
- Install in location with drainage.
- Fill tank with water before operation.
- Be alert for thermal expansion.
Refer to instruction manual for installation and service
Explosion Hazard
• Overheated water can cause
water tank explosion.
, Properly sized temperature
and pressure relief valve must
be installed in opening
provided
Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
Failure to do this court result in
death, serious bodily injury, or
propeRy damage.
\tVater temperature over 125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.
Children, the elderly, and the
physically or mentally disabled
are at highest risk for scald injury.
Feel water before bathing or
showering
Temperature limiting valves are
available.
Read instruction manual for safe
temperature setting
Fire Hazard / Electric Shock Hazard
Do not use this water heater with any
voltage other than shown on the model
• Failure to use the correct voltage shown
on the model rating plate could result in
death, serious bodily injury, or property

SAFE INSTALLATION, USEAND SERVICE ........................................................................................................................................ 2
GENERAL SAFETY ............................................................................................................................................................................. 3
TABLE OF CONTENTS ....................................................................................................................................................................... 4
PREPARING FOR THE NEW INSTALLATION .................................................................................................................................... 5
PRODUCT SPECIFICATIONS ............................................................................................................................................................ 5
MATERIALS AND BASIC TOOLS NEEDED ........................................................................................................................................ 6
Materials Needed ........................................................................................................................................................................ 6
Basic Tools .................................................................................................................................................................................. 6
Additional Tools Needed When Sweat Soldering ....................................................................................................................... 6
INSTALLATION INSTRUCTIONS ................................................................................................................................................... 7ol 6
Removing the Old Water Heater .............................................................................................................................................. 7,8
Facts to Consider About the Location ......................................................................................................................................... 8
Insulation Blankets ...................................................................................................................................................................... 8
Facts to Consider About the Convertible Lower Element ........................................................................................................ 8,9
Water Piping ........................................................................................................................................................................... 9,10
T & P Valve and Pipe Insulation ................................................................................................................................................. 10
TemperatureoPressure Relief Valve ..................................................................................................................................... 10,11
Filling the Water Heater ............................................................................................................................................................. 11
Converting the Lower Element ............................................................................................................................................. 11o14
Wiring .................................................................................................................................................................................... 14,15
Wiring Diagrams ....................................................................................................................................................................... 16
SERVICE AND MAINTENANCE .................................................................................................................................................. 17°22
Temperature Regulation ........................................................................................................................................................... 17
Thermostat ................................................................................................................................................................................ 17
Temperature Settings ................................................................................................................................................................ 17
Upper and Lower Thermostat Adjustments ......................................................................................................................... 17,18
Anode Rod Inspection ............................................................................................................................................................... 18
TemperatureoPressure Relief Valve Operation ......................................................................................................................... 18
Draining ................................................................................................................................................................................ 18,19
Thermostat Remova!/Replacement .......................................................................................................................................... 19
Element Cleaning/Replacement ......................................................................................................................................... 19°22
Drain Valve Washer Replacement ..............................................................................................................................................
Service .........................................................................................................................................................................................
TROUBLESHOOTING GUIDE .................................................................................................................................................... 23°25
Start Up Conditions ................................................................................................................................................................... 23
Thermal Expansion ............................................................................................................................................................ 23
Strange Sounds ................................................................................................................................................................. 23
Operational Conditions ....................................................................................................................................................... 23°25
Smelly Water .................................................................................................................................................................. 23,24
'Air" in Hot Water Faucets .................................................................................................................................................. 24
Rumbling Noise .................................................................................................................................................................. 24
High Temperature Shut Off System .................................................................................................................................... 24
Not Enough or No Hot Water ......................................................................................................................................... 24,25
Water Is Too Hot .................................................................................................................................................................. 25
Leakage Checkpoints .......................................................................................................................................................... 25,26
REPAIR PARTS MST .................................................................................................................................................................. 27°29
NOTES ......................................................................................................................................................................................... 30,31
WARRANTY ........................................................................................................................................................................................

ThankYouforpurchasinga Searswaterheater.Properly
instalbdandmaintained,it shouldgiveyouyearsoftrouble
freeservice.Itisstronglysuggestedthatthisnewwaterheater
beprofessionallyinstalled,contactthelocalSearsService
CenteroranySearsstore.Theywillarrangeforprompt,quality
installationbySearsauthorizedcontractors.
AbbreviationsFoundInThis{nstructionManual:
UL=UnderwritersLaboratoriesInc,
NEC= National Electrical Code
ANSI = American National Standards Institute
Read the "General Safety" section, page 3 of this manual
first and then the entire manual carefully. If you don't follow
the safety rules, the water heater wil! not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of this ebctric water heater. It
also contains warnings throughout the manual that you must
read and be aware of. Ai! warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING
TO INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the current edition of the
NEC o National Electrical Code, NFPA 70. This publication
is availabb from your local government or public library or
electric company or by writing Underwriters Laboratories
Inc., 333 Pfingsten Road, Northbrook, IL 60062.
If after reading this manual you have any questions or do
not understand any portion of the instructions, call Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock
and fires.
Examine the location to ensure the water heater complbs with
the "Facts to Consider About the Location" section.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.
Instructions may be obtained from the California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts 248oCMR 2.00; State
Plumbing Code and 248-CMR 5.00. In the Commonwealth of
Massachusetts, this product must be installed by a licensed
plumber or gasfitter.
TANK
MODEL
NUMBER
153.329262
153.329263
153.329360
153.329361
153.329460
153.329481
153.329560
153.329561
153.329660
153.329681
153.329880
153.329861
Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical
code.
CAPACITY
Gab Liters
38 144
30 114
40 151
55 208
66 250
80 303
DBMENSBONS
iN iNCHES (rnm)
DBA. HEIGHT
25 (635) 31.5 (800)
19 (483) 47 (1,194)
19 (483) 60 (1,524)
21.5 (546) 61 (1,549)
23 (584) 61 (1,549)
25 (635) 61.5 (1,562)
RECOVERY RATE WATTAGE
GALS.PER HOUR @240 VOLTS
@90°F Rise UPPER LOWER
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
17.3 3800 3800
25.0 3800 5500
173 3800 3800
25.0 3800 5500
ELEMENT
MINtMUM
WiRE SIZE*
{GAUGE)
12
10
12
10
12
10
12
10
12
10
12
10
MAXBMUM FUSE
OR qRCUr
BREAKER
SiZE (AMPS}
20
30
20
30
20
30
20
30
20
30
20
30

Materials Needed
To simplify the installation Sears has available the installation parts shown below. You may or may not need al! of these materials,
depending on your type of installation.
,/ / j
EXPANSION TANKS FOR THERMAL
EXPANSION CONDmONS AVAmLABLE _N2
GALLONS _AND 5 GALLONS CAPACITY
THROUGH LOCAL SEARS STORE OR
WATER HEATER INSTALLATION Kr WRTH
FLEXmBLE CONNECTORS FOR 3/4" OR 112"
THREADED OR COPPER PLUMBING
SERVICE CENTER.
Basic Too_s
You may or may not need al! of these tools, depending on your
type of installation, These tools can be purchased at your local
Sears store,
Pipe Wrench (2)
Screwdriver
6 Foot'rape or Folding Rume
Garden Hose
DriH
Pipe Dope or Teflon .rape
DRILL
SLOT-HEADSCREWDRIVER
ROLL OF TEFLON TAPE (USE ON
WATER CONNECTIONS)
PHLLIPS SCREWDRIVER
DRARN PANS AVABLABLE IN 20"
DIAMETER FORWATER HEATERS
NAWNG A DIAM ETER 18" OR LESS,
24" DRAMETER FOR WATER
HEATERS HAWNG A DBAMETER 22"
OR LESS AND AVABLABLE IN 28"
DBAMETER FOR WATER HEATERS
HAVING A DBAMETER 20" OR LESS,
Additiona_ Too_s Needed When Sweat
So_dering
Tubing Cutters or Hacksaw
Propane Torch
Soft Solder
Solder Flux
Emery Cloth
Wire Brushes
TUBING CUTTER
HACKSAW
PIPE DOPE (SQUEEZE TUBE)
USE FOR WATER CONNECTIONS
GARDEN HOSE 6 FOOTTAPE
PIPE WRENCH
1
PROPANE
TORCH
ROLL OF
EMERYCLOTH
ROLL OF
LEAD-FREE
SOFT SOLDER
314" (19 ram}WIRE BRUSH
1/2" (13 ram) WiRE BRUSH
SOLDER
FLUX

Removing the O_d Water Heater
FIGURE 1.
Q Turn "OFF" electrical supply to the water heater.
Burn hazard
• Hotwater discharge.
Keep hands clear of drain
The water passing out of the drain valve may be extremely hot.
To avoid being scalded, make sure al! connections are tight
and that the water flow is directed away from any person.
(_j_ Check again to make sure the electrica! supply is turned
'OFF" to the water heater. Then unplug the water heater
(cord set) or disconnect the electrical supply connection
from the water heater junction box.
FIGURE 2.
Q Turn "OFF" the water to the water heater at the water
shut-off valve or water meter.
Q Attach a hose to the ,water heater drain valve and put the
other end in a floor drain or outdoors. Open the water heater
drain valve. Open a nearby hot water faucet which will relieve
pressure in the water heater and speed draining.
supply
FIGURE 3.
FIGURE 4.
Qa.
FIGURE 5.
If you have copper piping to the water heater, the two
copper water pipes can be cut with a hacksaw
approximately four inches away from where they connect
to the water heater. This will avoid cutting off the pipes
too short. Additional cuts can be made later if necessary.
Disconnect the temperature-pressure relief valve
drain line. When the water heater is drained, disconnect
the hose from the drain valve. Close the drain valve.
The water heater is now completely disconnected and
ready to be removed.
FIGURE 6.
If you have galvanized pipe to the water heater, loosen
the two galvanized pipes with a pipe wrench at the
union in each line. Also disconnect the piping
remaining to the water heater. These pieces should
be saved since they may be needed when
reconnecting the new water heater. Disconnect the
temperature-pressure relief valve drain line. When the
water heater is drained, disconnect the hose from the
drain valve. Close the drain valve. The water heater is
now completely disconnected and ready to be
removed.

_ineraiBuilduporSediment MayAccumuiate
• This causes the water heater to become
much heavier than normal.
,' IfspiNed, could cause staining.
Mineral buildup or sediment may have accumulated in the old
water heater. This causes the water heater to be much heavier
than normal and this residue, if spilled out, could cause staining.
Facts to Consider About the Location
You should carefully choose an indoor location for the new
water heater, because the placement is a very important
consideration for the safety of the occupants in the building
and for the most economical use of the appliance. This water
heater is not intended for outdoor installation.
Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed.
The location selected should be indoors as close to and as
centralized with the water piping system as possible. This
water heater, as well as all water heaters, will eventually
leak. Do not install without adequate drainage provisions
so water flow will not cause damage.
devices are available from your local Sears store, and detect
and react to leakage in various ways:
* Sensors mounted in the drain pan that trigger an alarm or
turn off the incoming water to the water heater when leakage
is detected.
* Sensors mounted in the drain pan that turn offthe water supply
to the entire home when water is detected in the drain pan.
* Water supply shut-off devices that activate based on the water
pressure differential between the cold water and hot water
pipes connected to the water heater.
Installations in Residentiam Garages
" Water heater must be located in a
protective area
iNSTALLATiON IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it is not subject to physical
damage by a moving vehicle.
* The location selection must provide adequate clearances
for servicing and proper operation of the water heater.
_nsu_ation B_ankets
Insulation blankets are available to the general public for
external use on electric water heaters but are not necessary
with this product. The purpose of an insulation blanket is to
reduce the standby heat loss encountered with storage tank
heaters. Your water heater meets or exceeds the National
Appliance Energy Conversation Act standards with respect to
insulation and standby loss requirements, making an insulation
blanket unnecessary.
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions below. Failure to follow
these instructions can result in fire, serious personal injury, or
death.
Property Damage Hazard
, All water heaters eventually leak
, Do not install without adequate drainage
WATER HEATERS EVENTUALLY LEAK: Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water wil! not cause
damage to the structure. When such locations cannot be
avoided, a suitable drain pan should be installed under the
water heater. Drain pans are available at your local Sears stores.
Such drain pans must be piped to an adequate drain.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed.
Water heaters are sometimes installed in locations where
leakage may result in property damage, even with the use of a
drain pan piped to a drain. However, unanticipated damage
can be reduced or prevented by a leak detector or water shut-
off device used in conjunction with a piped drain pan. These
Do not cover the temperature and pressure relief (T & P)
valve with an insulation blanket.
* Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
* Do obtain new warning and instruction labels from Sears
for placement on the blanket directly over the existing labels.
Facts to Consider About the
Convertible Lower E_ement
The Upper Element (if a double element model) is a
conventional 3800 watt element which only operates at its rated
wattage on 240 volts. (See rating plate on the water heater).
The Lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.
Read and follow water heater warnings and instructions. If
after reading these instructions in this manual, you do not
understand any portion, call Sears Service Center.

Fire Hazard / Electric Shock Hazard
Do not use this water heater with
any voltage other than shown on the
model rating plate.
®
Failure to use the correct voltage
shown on the model rating plate
could result in death, serious bodily
injury, or property damage
Before making the conversion to 5500 watts, check the (1)
power supply . . . must be 240 volts, (2) wiring . . . 10 gauge
AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers
or fusing . . .capable of 30 amp loading. Also, the installation
must conform with this manual, local codes and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE.
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing
needs can scald and permanently injure you upon contact.
Some people are more likely to be permanently injured by hot
water than others. These include the elderly, children, the infirm,
or physically/mentally handicapped. If anyone using hot water
in your home fits into one of these groups or if there is a local
code or state law requiring a certain temperature water at the
hot water tap, then you must take special precautions. In
addition to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a mixing
valve, shall be used at the hot water taps used by these people
or at the water heater. Mixing valves are available at plumbing
supply or hardware stores. Follow manufacturers instructions
for installation of the valves. Before changing the factory setting
on the thermostat, read the "Temperature Regulation" section
in this manual.
See Figure 8 for mixing valve usage.
f
HOT WATER[_ f _
OUTLET
INLET
WATER
WATE R H EATER 9s2N
ELECTRDC Q LUSTED
MODEL NUMBER US. GAL. SERIAL NUMBER
FACTORY EQUIPPED WITH
UPPER LOWER CHECK HERE WORKING
ELEMENT ELEMENT rVIAXIMUM VOLTS _F INSTALLEDAS PRESSURE
WATTS WATTS WATTS AC ONLY FACTORY EQUIPPED PSi
OPTIONAL WATTAGE
UPPER LOWER
ELEMENT ELEMENT MAXIMUM CHECK HERE
WATTS WATTS WATTS IF CONVERTED
NOTE: Whether or not the element conversion is made the
model rating plate must be marked. Using a hard point ink
pen, check the appropriate block within the model rating plate,
which is located adjacent to the lower access panel.
CAPACITY
MAXIMUM
WARNING
SEE CONVERSION
INSTRUCTION
Water Piping
Water temperature over 125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death,
Children, the elderly, and the
physically or mentally disabled
are at highest risk for scald injury.
Feel water before bathing or
showering,
Temperature limiting valves are
available,
Read instruction manual for safe
temperature setting.
O_ COLD
TEMPERE
WATER M F_ _- _
OUTL 0 TOOOLO',,ATE*
WATER HEATER
*MIXING OUTLET ON
FROMa WATER
VALVE WATER N_=ATER
FIGURE 8.
Figure 9 shows the attachment of the water piping to the water
heater. The water heater is equipped with 3/4" water
connections.
If a water heater is installed in a closed water supply system;
such as one having a back41ow preventer, check valve, water
meter with a check valve, etc.., in the cold water supply; means
must be provided to control thermal expansion. Contact the
local utility or Sears Service Center on how to control this
situation.
NOTE: If using copper tubing, solder tubing to an adapter
before attaching the adapter to the water inlet connection.
Do Rot solder the water supply Hnes directly to the cold water
inlet, mtwill harm the dip tube and damage the tank.
Property Damage Hazard
- Avoid water heater damage.
, Install thermal expansion tank if necessary.
, Do not apply heat to cold water inlet.
, Contact qualified installer or service agency.
÷,.o.o°

NOTE:Toprotectagainstuntimelycorrosionofhotandcored
waterfittings,it is stronglyrecommendedthatdioemectric
unionsorcouplingsbeinstalledor}thiswaterheaterwhen
connectedtocopperpipe.
FitT&Pvalveinsulationovervalve.Makesurethattheinsulation
doesnotinterferewiththeleveroftheT&Pvalve.
Secureallinsulationusingtape.
1.Lookatthetopcoverofthewaterheater.Thehotwateroutlet
ismarkedhot.Puttwoorthreeturnsofteflontapearound
thethreadedendofthethreaded-to-sweatcouplingand
aroundbothendsofthe3/4"threadednipple.Usingflexible
connectors,connectthehotwaterpipetothehotwateroutlet
ofthewaterheater.
2.Lookatthetopcoverofthewaterheater.Thecoldwaterinlet
ismarkedcold.Puttwoorthreeturnsofteflontapearound
thethreadedendofthethreaded-to-sweatcouplingand
aroundbothends of the 3/4" threaded nipple. Using flexible
connectors, connect the cold water pipe to the cold water
inlet of the water heater.
NOTE: Your water heater is insulated to minimize heat loss
from the tank. Further reduction in heat Boss can be
accomplished by insu[ating the hot water lines from the
water heater.
HOT FLEXIBLE SHUT-OFF
OUTLET WATER CONNECTORS VALVE
TO
HOUSE [_
l COLD
THREADED THREADED WATER
TO SWEAT TO SWEAT UNE
COUPLING COUPLING
REUEF VALVE
/"
INLET
PRESSURE
PiPE
iNSULATION
i
iNSULATION \i\_J
FIGURE gA.
Temperature-Pressure Relief Valve
Explosion Hazard
, Temperature-pressure relief valve
must comply with ANSI A21.22
and ASME code.
" Properly sized temperature-relief
valve must be installed in opening
provided.
, Can result in overheating and
excessive tank pressure
" Can cause serious iniury or death.
DISCHARGE
-- PIPE
(DO NOT CAP
OR PLUG}
FIGUREg.
T & P Valve and Pipe insulation
Remove insulation for T & P valve and pipe connections from
carton.
Fit pipe insulation over the incoming cold water line and the hot
water line. Make sure that the insulation is against the top
cover of the heater.
This heater is provided with a properly certified combination
temperature - pressure relief valve by the manufacturer.
The valve is certified by a nationally recognized testing
laboratory that maintains periodic inspection of production of
listed equipment of materials as meeting the requirements for
Relief Valves and Automatic Gas Shut-off Devices for Hot Water
Supply Systems, ANSI Z21.22 • CSA 4.4, and the code
requirements of ASME.
If replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure relief valve certified as indicated in the above
paragraph.
The valve must be marked with a maximum set pressure not to
exceed the marked hydrostatic working pressure of the water
heater (150 psi = 1,035 kPa) and a discharge capacity not less
than the water heater input rate as shown on the model rating
plate.
For safe operation of the water heater, the relief valve must not
be removed from its designated opening nor plugged.
The temperature-pressure relief valve must be installed directly
into the fitting of the water heater designed for the relief valve.
10

Positionthevalvedownwardandprovidetubingsothatany
dischargewillexitonlywithin6inches(153mm)above,orat
anydistancebelowthestructuralfloor.Becertainthatnocontact
ismadewithanyliveelectricalpart.Thedischargeopening
mustnot be blockedor reducedin size underany
circumstances.Excessivelength,over30feet(9.14m),oruse
ofmorethanfourelbowscancauserestrictionandreducethe
dischargecapacityofthevalve.
Ifaftermanuallyoperatingthevalve,itfailstocompletelyreset
andcontinuestoreleasewater,immediatelyclosethecold
waterinlettothewaterheater,followthedraininginstructions,
andreplacethetemperature-pressurereliefvalvewithanew
one.
COLD
Water Damage Hazard
, Temperature-pressure relief valve discharge
pipe must terminate at adequate drain.
No valve or other obstruction is to be placed between the relief
valve and the tank. Do not connect tubing directly to discharge
drain unless a 6 inch air gap is provide& To prevent bodily
injury, hazard to life, or property damage, the relief valve must
be allowed to discharge water in quantities should
circumstances demand. If the discharge pipe is not connected
to a drain or other suitable means, the water flow may cause
property damage.
The Discharge Pipe:
* Shall not be smaller in size than the outlet pipe size of the
valve, or have any reducing couplings or other restrictions.
Shall not be plugged or blocked.
* Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both
the temperature-pressure relief valve, and the discharge
pipe.
TEMPERATURE-
/, PRESSURE
, _/ REUEF VALVE
'_ D_SCHARGE PUPE
(DO NOT CAP OR PLUG)
O-
G" AiR GAP
FLOOR DRAIN
FIGURE 10.
Filling the Water Heater
* Shall terminate at an adequate drain.
* Shall not have any valve between the relief valve and tank.
Water temperature over 125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death,
Children, the elderly, and the
physically or mentally disabled
are at highest riskfor scald iniury.
Feel water before bathing or
showering,
Temperature limiting valves are
available
Read instruction manual for safe
temperature setting
The temperature-pressure relief valve must be manually
operated at least once a year. Caution should be taken to
ensure that (1) no one is in front of or around the outlet of the
temperature-pressure relief valve discharge line, and (2) the
water manually discharged will not cause any bodily injury or
property damage because the water may be extremely hot.
Property Damage Hazard
- Avoid water heater damage.
- Fill tank with water before operating.
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with waten Water must flow from the hot water
faucet before turning 'ON" power.
To fill the water heater with water:
1. Close the water heater drain valve by turning the handle to
the right (clockwise). The drain valve is located on the lower
front of the water heater.
2. Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when
the water heater is in use.
3. To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run until
a constant flow is obtained. This will let air out of the water
heater and the piping.
11

4.Checkallnewwaterpipingforleaks.Repairasneeded.
Converting the Lower E_ement
Necessary element conversion parts are located in a small
bag contained within the electrical junction box on top of the
water heater.
These instructions only cover the conversion of the convertible
element, read this entire manual before attempting to install or
operate the water heater. The water heater is factory set to
operate at 3800 watts. The lower element can be converted to
operate at 5500 watts. Refer to "Facts to Consider About the
Convertible Lower Element" section.
The Upper Element, (if double element model) is a
conventional 3800 watt element which only operates at its rated
wattage on 240 volts. (See rating plate on the water heater.
The lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.
If after reading these instructions and this manual, if you do not
understand any portion call Sears Service Center.
Fire Hazard t Electric Shock Hazard
%
Do not use this water heater with
any voltage other than shown on the
model rating plate.
Failure to use the correct voltage
shown on the model rating plate
could result in death, serious bodily
injury, or property damage.
CONVERSION PARTS
SCREW
BUSS BAR
FIGURE 12.
1. Before beginning the conversion turn "OFF" electric power
supply to the water heater.
FIGURE 13.
The convertible element is located behind the lower
access panel of the water heater. Remove the two screws
securing the access panel, and remove panel.
Before making the conversion to 5500 watts, check the (1)
power supply . . _ must be 240 volts, (2) wiring . . . 10 gauge
AWG @ Type TW, 60°C or equivalent, and (3) Circuit breakers
or fusing . . .capable of 30 amp Ioading. Also, the installation
must conform with this manual, local codes and electric utility
rules. Failure to comply can result in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE
NOTE: Whether or not the element conversion is made the
model rating plate must be marked. Using a hard point ink
pen, check the appropriate block within the model rating plate,
which is located adjacent to the lower access panel.
WATER HEATER _32N
ELECTRIC O USTED
MODEL NUMBER US GAL SERIAL NU_,_BER
FACTORY FQUmPPFD W_TH
_PPER LOWER CHECK HERE WORKING
ELEMENT ELEMENT MAXIMUM VOLTS IFENSTb, LLEDAS PRESSURE
WATTS WATTS WATTS AC ONLY FACTORY EQUIPPED PSI
OPTIONAL WATTAGE
UPPER LOWER
ELEMEN_ ELE]k_ENT _,IAXMUM CHECK HERE
WATTS WATTS WATTS IF CONVERTED
- I I
CAPACETY
FIGURE11.
WARNING
SEE CONVERSION
INSTRUCTEON
hIAX_1UM
FIGURE 14.
Remove the insulation cap with handle to expose the
terminal cover.
I-1
FIGURE1&
Lower Element: Lift out the tab as shown to unclip the
terminal cover from the thermostat, The terminal cover can
now be removed from the thermostat,
12

LIFT OUT TAB TO UNCUP
?ERMBNAL COVER FROM
THERr41OSTAT
FIGURE 16.
5,
Remove the screws from terminal 2 of the element, and
move the looped end of the wire aside.
8. Tighten terminals 2 and 3 to ensure proper electrical
connection.
Fire and Explosion Hazard
• Failure to tighten screws can
cause a fi re.
o Failure to do this could result in
death, serious bodily injury, or
property damage,
Failure to tighten terminal screws can cause a fire which can
result in DEATH, SERIOUS BODILY iNJURY, OR PROPERTY
DAMAGE.
9. Replace terminal cover on thermostat making sure that
the locking tabs on the terminal cover are in place.
FIGURE 17.
6,
The buss bar is labeled 5500 W. Place the buss bar over
terminals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.
FIGURE 18.
7,
The wire removed from terminal 2 has a looped end. It
must remain looped and now be placed (as shown) on
top of the buss bar, over the opening of terminal 2, and
secured using the remaining screw.
Fire and Explosion Hazard
o Thermostat must be flush
againstthe tank,
,, Make sure terminal cover is in
place and the insulation
replaced.
® Failure to do this could result in
death, serious bodily injury, or
property damage.
Make sure the thermostat is flush against the tank, the terminal
cover is in place, and the insulation is replaced. Failure to do
so can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.
10. Replace the insulation cap with handle back in place so
that it completely covers the thermostat and element.
FIGURE 19.
FIGURE 20.
13

11.Replacetheaccesspanel.
If you are not familiar with electric codes and practices, or if you
have any doubt, even the slightest doubt, in your ability to connect
the wiring to this water heater, obtain the service of a competent
electrician. Contact your Sears salesperson to arrange for a
professional electrician.
Fire Hazard I Electric Shock Hazard
FIGURE 21,
12. Complete wiring to the water heater, or if completed, turn
"ON" electric power to the water heater after filling the tank
with water.
FIGURE 22,
improper installation and use may result
in property damage,
• Fill tank with water before operation.
Do not use this water heater with
any voltage other than shown on the
i
model rating plate.
®
Failure to use the correct voJtage
shown on the model rating plate
could result in death, serious bodily
injury, or property damage.
WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This
water heater is equipped for one type voltage only. Check the
rating plate near the bottom access pane! for the correct voltage.
DO NOT use this water heater with any voltage other than the
one shown on the model rating plate. Failure to use the correct
voltage can cause problems which can result in DEATH,
SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you
have any questions or doubts consult your electric company.
If wiring from your fuse box or circuit breaker box was aluminum
for your old water heater, replace it with copper wire. If you wish
to reuse the existing aluminum wire, have the connection at
the water heater made by a competent electrician. Contact your
Sears salesperson to arrange for a professional electrician.
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. Water must flow from the hot water
faucet before turning 'ON" power.
Wiring
Improper installation and use may result
in property damage.
, FiJl tank with water before operation.
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. Water must flow from the hot water
faucet before turning on power.
You must provide all wiring of the proper size outside of the
water heater. You must obey !ocal codes and electric company
requirements when you install this wiring.
Provide a way to easily shut off the electric power when
working on the water heater. This could be with a circuit
breaker or fuse block in the entrance box or a separate
disconnect switch.
Install and connect a circuit directly from the main fuse or
circuit breaker box. This circuit must be the right size and
have its own fuse or circuit breaker. Refer to the chart in the
"Product Specifications" section for the correct size wire and
fuse or circuit breaker.
3. If metal conduit is used for the grounding conductor:
The grounding electrode conductor shall be of copper,
aluminum, or copperclad aluminum. The material
shall be of one continuous length without a splice or
joint.
a.
Rigid metal conduit, intermediate metal conduit, or
electrical metallic tubing may be used for the grounding
means if conduit or tubing is terminated in fittings
approved for grounding.
C. Flexible metal conduit or flexible metallic tubing shall
be permitted for grounding if all the following
conditions are met:
14

Thelengthinanygroundreturnpathdoesnotexceed
6feet,
Thecircuitconductorscontainedthereinareprotected
byovercurrentdevicesratedat20amperesorless,
NOTE: If you have purchased a three wire connection water
heater but you are not on a 'Time Clock" or 'Off Peak" meter
and have a standard two wire connection power supply,
simply follow the connection diagram in block 3 of the three
wire connection diagram,
Theconduitortubingisterminatedinfittingsapproved
forgrounding,
Forcompletegroundingdetailsandallallowableexceptions,
refertothecurrenteditionoftheNEC-NationalElectricalCode
NFPA70,
4,Astandard1/2"conduitopeninghasbeenmadeinthewater
heaterjunctionboxfortheconduitconnection,
5,WiringDiagrams,see"Wiring Diagrams" section have been
supplied showing the two most common types of
connections between the water heater and the power supply.
You can easily see which type connection you have by
removing the junction box cover on top of the water heater,
Two Wire Connection Diagrams: is the most common
requiring you to simply connect red to red, black to
black, and the ground wire to the green ground screw
in the junction box of the water heater.
Three Wire Connection Diagram: is used when you
are connecting the water heater to a power supply
that has a "Time Clock" or "Off Peak" meter, To make
these connections refer to block 1 or 2 in this wiring
diagram for the type of system you have,
6,
Use wire nuts and connect the power supply wiring to the
wires inside the water heater's junction box,
The water heater must be electrically "grounded" by the
installer. A green ground screw has been provided on the
water heater's unction box, Connect ground wire to this
location.
8,
Replace the wiring junction cover using the screw provided,
CONDU_T
GREEN
GROUND
SCREW
FIGURE 23.
15

Wiring Diagrams
STANDARD WIRING FOR 2W{RE LEAD WATER HEATERS
NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT
UPPERE.C.O. I& THERMOSTAT
TO ELECTRIC
POWER SUPPLY
RED
[
Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
Failure to do this could result in
death, serious bodily injury, or
property damage.
FOR 5500 WATTS
BUSS
UPPER
ELEMENT
LOWER
FIGURE 24.
WIR{NG FOR 3 WIRE LEAD WATER HEATERS NON-SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT
3. FOR TWO WiRE CONNECTION
TO ELECTRIC _¢===_
POWER SUPPLY L1 L2
HEATING ELEMENT
LOWER HEATING
ELEMENT
FIGURE 2&
16

Temperature Regulation
Water temperature over 125°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.
Children, the elderly, and the
physically or mentally disabled
are at highest risk for scald injury.
Feel water before bathing or
showering
Temperature limiting valves are
available.
Read instruction manual for safe
temperature setting
The lower thermostat is factory set at HOT a position which
approximates 120°F (49°C) and is adjustable if a different water
temperature is desired. Read all warnings in this manual and
on the water heating before proceeding.
ADJUSTABLELOWERTHERMOSTAT
WITH HIGH LIMIT
(3 W{RE LEAD MODELS)
ADJUSTABLE LOWER
THERMOSTAT
(2 WIRE LEAD MODELS)
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will
satisfy clothes washing, dish washing, and other sanitizing
needs can scald and permanently injure you upon contact
Some people are more likely to be permanently injured by hot
water than others. These include the elderly, children, the infirm,
or physically/mentally handicapped. If anyone using hot water
in your home fits into one of these groups or if there is a Ioca!
code or state law requiring a certain temperature water at the
hot water tap, then you must take special precautions. In
addition to using the lowest possible temperature setting that
satisfies your hot water needs, some type of tempering device,
such as a mixing valve, should be used at the hot water taps
used by these people or at the water heater. Mixing valves are
available at plumbing supply or hardware stores. Follow
manufacturers instructions for installation of the valves, Before
changing the factory setting of the thermostat, read the
"Temperature Regulation" section in this manual.
Never allow small children to use a hot water tap, or to draw
their own bath water. Never leave a child or handicapped person
unattended in a bathtub or shower.
Thermostat
The thermostats of this water heater have been factory set at
HOT a position which approximates 120°F (49°C). to reduce
the risk of scald injury.
FIGURE 27.
Temperature Settings
HOT -
VERY -
HOT
NOTE: Water temperature range of 120°--140°F (49°o60°C)
recommended by most dishwasher manufacturers.
VERY HOT =APPROX.160°F (71°C)
C =APPROX.150°F (65°C)
B =APPROX. I40'T (60'_C)
A = APPROX.130°F (54°C)
HOT = APPROX.120°F (49°C)
Is a thermostat setting of approximately 120°F
(49°C), which will supply hot water at the most
economical temperatures.
A -
Is a thermostat setting of approximately
130°F (54°C).
B-
Is the thermostat setting of approximately
140°F (6O°C).
C-
Is a thermostat setting of approximately
150°F (65°C).
Is a thermostat setting of approximately
160°F (71°C). It is recommended that the dial be
set lower whenever possible.
About 1/2 second
About 1-1/2 seconds
Less than 5 seconds
About 30 seconds
More than 5 minutes
The upper thermostat is factory set at HOT a position which
approximates 120°F (49°C) and is adjustable if a different water
temperature is desired. Read al! warnings in this manual and
on the water heating before proceeding.
ADJUSTABLE UPPER THERMOSTAT
FIGURE 26.
Upper and Lower Thermostat Adjustments
Refer to thermostat illustrations under "Thermostat" section
Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
Failure to do this could result in
death, serious bodily injury, or
property damage.
17

NOTE:It isnotnecessarytoadjusttheupperthermostat.
However,ifit isadjustedabovethefactorysetpointof 120°F
(49°C)HOTitisrecommendedthatitnotbesethigherthanthe
lowerthermostatsetting.
Theupperandlowerthermostatsareadjustableifa different
watertemperatureis desired.Readal!warningsin the
'Temperature-Regulation"sectionbeforeproceeding.
1.Turn"OFF"theelectricpowertothewaterheateratthe
junctionbox.
Temperature-Pressure Relief
Valve Operation
The temperature-pressure relief valve must be manually
operated at least once a year.
• Burn hazard
• Hotwater discharge.
i
, Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
', Failure to do tHs could result in
death, serious bodily injury, or
property damage.
2. Take off the upper and/or lower access panel, insulation
cap with handle.
3. The slotted adjustment (using a screwdriver) can be turned
clockwise ( f_ ) to increase the temperature setting or
counter clockwise ( _'_ ) to decrease the temperature setting.
4. Replace the insulation cap with handle and access panel.
5. Turn 'ON" the power supply.
Anode Rod inspection
• Keep clear of reHiefvalve
The temperature-pressure relief valve must be manually
operated at least once a year. Caution should be taken to ensure
that (1) no one is in front of or around the outlet of the
temperature-pressure relief valve discharge line, and (2) the
water manually discharged will not cause any property damage
or bodily injury. The water may be extremely hot.
TEMPERATURE=PRESSURE
RELIEF VALVE
DISCHARGE PiPE
FIGURE 28.
If after manually operating the valve, it fails to completely reset
and continues to release water, immediately close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure relief valve with a new
one,
Property Damage Hazard
, Avoid water heater damage.
• Inspection and replacement of anode as needed.
The anode rod is used to protect the tank from corrosion. Most
hot water tanks are equipped with an anode rod. The
submerged rod sacrifices itself to protect the tank. Instead of
corroding the tank, water ions attack and eat away the anode
rod. This does not affect the water's taste or color. The rod
must be maintained to keep the tank in operating condition.
Anode deterioration depends on the water conductivity, not
necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/
or replaced more often than an anode rod that appears to be
intact. Replacement of a depleted anode rod can extend the
life of your water heaten Inspection should be conducted by
calling Sears Service Center. At a minimum the anode(s)
should be checked annually after the warranty period.
Failure to install and maintain a new properly listed temperature°
pressure relief valve will release the manufacturer from any
claim which might result from excessive temperature or
pressure.
If the temperature-pressure relief valve on the appliance weeps
or discharges periodically, this may be due to thermal
expansion. Your water heater may have a check valve installed
in the water line or a water meter with a check valve. Consult
your local Sears Service Center for further information. Do not
plug the temperature-pressure relief valve.
Draining
Burn hazard
• Hotwater discharge,
o Keep hands clear of drain
18

Thewaterheatershouldbedrainedifbeingshutdownduring
freezingtemperatures.Also,periodicdrainingandcleaningof
sedimentfromthetankmaybenecessary.
i
Before removing any access
panels or servicing the water
heater, make sure the ebctrical
supply to the water heater is
turned "OFF",
t Failure to do this could result in
death, serious bodily injury, or
property damage,
1. Before beginning turn "OFF" the electric power supply to the
water heater.
2. CLOSE the cold water inlet valve to the water heater.
3. OPEN a nearby hot water faucet and leave open to allow for
draining.
4. Connect a hose to the drain valve and terminate to an
adequate drain or outdoors.
5. OPEN the water heater drain valve to allow for tank draining.
NOTE: Bf the water heater is going to be shut down and
drained for an extended period, the drain vaJve shouJd be left
open with hose connected allowing water to terminate to an
adequate drain.
1. Turn "OFF" the electrical power to the water heater at the
junction box.
2. Remove the access pane! and the insulation cap with
handle.
3. Lift out the tab as shown below to unclip the terminal cover
from the thermostat The terminal cover can now be removed
from the thermostat.
UFT OUT TAB TO UNCUP
TERMINAL COVER
FROM THERMOSTAT
LOWER THERMOSTAT
WITHOUT HIGH LIMIT
UPPER AND LOWER
THERMOSTAT WITH
H_GH L_MIT
FIGURE 2g.
6. Close the drain valve.
7. Follow "Fifling the Water Heater" instructions in the
'Installation Instructions" section.
8. Turn 'ON" power to the water heater.
improper installation and use may result
in property damage.
o Fill tank with water before operation
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. Water must flow from the hot water
faucet before turning "ON" power.
Thermostat Removal/Replacement
Before removing any access
panels or servicing the water
heater, make sure the electrical
suppJy to the water heater is
turned "OFF"
• Failure to do this could result in
death, serious bodily injury, or
property damage,
4. Remove the wires attached to the thermostat.
5. Remove the thermostat from behind the thermostat
bracket.
6. Disconnect wires from thermostat and slide out of the
bracket.
7. Place the new thermostat in the bracket making sure it fits
firmly against the tank.
8. Attach the wires to the new thermostat.
NOTE: Some of the terminals may require straightdn wiring
through an eye-opening. If wires are now looped, recut and
strip wire 3/8" to a straight Jength and insert.
9. Put plastic terminal cover back in place.
10. Replace the insulation cap with handle to cover the
thermostat.
11. Replace access panel, then turn the electric power on.
E_ement C_eaningiRepmacement
NOTE: These instructions are written for element cleaning and
element replacement for the lower element. If it is necessary to
clean or replace the upper element, then repeat these
instructions.
To remove the element from your tank in order to clean or
replace it:
19

{
Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
Failure to do this could result in
death, serious bodily injury, or
property damage.
1. Before beginning turn "OFF" the electric power supply to
the water heater.
FIGURE 30,
2. Turn off the water supply to the water heater at the water
Shut-off valve or water meter.
Remove the two screws securing the access panel, and
remove pane!.
FIGURE 33.
Remove the insulation block and pad.
Q_
FIGURE 31,
3.
Attach a hose to the water heater drain valve and put the
other end in a floor drain or outdoors. Open the water heater
drain valve. Open a nearby hot water faucet which will relieve
pressure in the water heater and speed draining.
FIGURE 32.
,, Burn hazard
o Hot water discharge.
- Keep hands clear of drain
valve discharge.
FIGURE 34.
Lift out the tab as shown to unclip the terminal cover from
the thermostat. The terminal cover can now be removed
from the thermostat.
UFT OUT TAB TO UNCLIP
TERMINAL COVER
FROM THERMOSTAT
LOWER THERMOSTAT
WITHOUT HiGH LIMIT
UPPERAND LOWER
THERMOSTAT W_TH
HIGH LIMIT
FIGURE 35.
Disconnect the two wires on the element and unscrew the
old element from the tank.
The water passing out of the drain valve may be extremely hot.
To avoid being scalded, make sure al! connections are tight
and that the water flow is directed away from any person.
FIGURE 36.
2O

8,
Clean the area around the element opening, Remove any
sediment from or around the element opening, inside the
tank,
g,
If you are cleaning the element you have removed, do so by
scraping or soaking in vinegar or a deoliming solution,
Fire Hazard and
Electric Shock Hazard
* Do not use replacement elements with
any voltage other than shown on the
model rating plate.
• Failureto use the correct voltageshown
on the model rating plate could result in
death, serious bodily injury, or property
damage.
Replacement elements must (1) be the same voltage and (2)
no greater wattage than listed on the model rating plate affixed
to the water heater,
10. A new gasket should be used in all cases to prevent a
possible water leak, (See Element Gasket in the 'Parts
Order List " Chart). Place the new element gasket on the
thread side of the cleaned or new element and screw into
tank, securing tightly using an element wrench,
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. Water must flow from the hot water
faucet before turning 'ON" power.
14, Check element for water leaks. If leakage occurs, tighten
element or repeat steps 2 and 3> remove element and
reposition gasket. Then repeat steps 10 through 14.
15, Reconnect the two wires to the element and then check to
make sure the thermostat remains firmly against the
surface of the tank.
FIGURE 38.
16, Replace terminal cover on thermostat making sure that
the locking tabs on the terminal cover are in place,
/
UFT OUT TAB TO UNCUP
TERMINAL COVER
FROM THERMOSTAT
FIGURE 37.
11, Close the water heater drain valve by turning the handle to
the right (c!ockwise). The drain valve id on the lower front of
the water heater.
12. Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when the
water heater is in use.
13. To insure complete filling of the tank, allow air to exit by
opening the nearest hot water faucet, Allow water to run
until a constant flow is obtained, This will let air out of the
water heater and the piping,
Improper installation and use may result
in property damage.
• Fill tank with water before operation,
LOWER THERMOSTAT
WITHOUT HIGH LIMIT
UPPER AND LOWER
THERMOSTAT WITH
HiGH LIP_,IlT
FIGURE 39.
17, Place the insulation cap with handle back in place so that
it completely covers the thermostat and element.
i-1
FIGURE 40.
21

18. Replace access panel,
Follow "Draining" instructions. See "Draining" section.
19. Turn "ON" electric power to water heater,
Drain Valve Washer Repmacement
[
Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
Failure to do this could result in
death, serious bodily injury, or
property damage.
* Turning counter clockwise, remove the hex cap below the
screw handle.
* Remove the washer and put the new one in place.
* Screw the handle and cap assembly back into the drain
valve and retighten using a wrench. DO NOT OVER
TIGHTEN.
Follow "Filling the Water Heater" instructions in the
"lnstaflation Instructions" section.
* Check for leaks.
Turn "ON" electric power to the water heater.
_"_ HANDLEAND
CAP ASSEMBLY
WASHER
FIGURE 42.
Service
NOTE: For replacement, use a 17/32" × 13164 °' × 1/8" thick
washer available at your nearest hardware store. For
ordering a replacement washer, refer to the "Parts Order
List" section.
Before beginning turn "OFF" the electrical power supply to
the water heater.
Before calling for repair service, read the "Start Up Conditions"
and "Operational Conditions" found in the Troubleshooting
section of this manual.
If a condition persists or you are uncertain about the operation
of the water heater, let a qualified person check it out.
Contact Sears Repair Services at l oS00o4oMyoHOME
(1 o800o469o4663).
22

Start Up Conditions
TNERMAL EXPANSmON
Property Damage Hazard
° Avoid water heater damage.
o Install thermal expansion tank or device if necessary.
oContact qualified installer or service agency.
NOTE: Expansion tanks are preocharged with a 40 psi air
charge. Bfthe inlet water pressure is higher than 40 psi, the
expansion tank's air pressure must be adjusted to match
that pressure, but must not be higher than 80 psi.
WATER HEATER (3)
COLD WATER PRESSURE
0NLET FITTING REDUCING
VALVE WITH
BY-PASS
Water supply systems may, because of such events as high
line pressure, frequent cut-offs, the effects of water hammer
among others, have installed devices such as pressure
reducing valves, check valves, back flow preventers, etc._to
control these types of problems. When these devices are not
equipped with an internal by-pass, and no other measures are
taken, the devices cause the water system to be close& As
water is heated, it expands (thermal expansion) and closed
systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated
and increases the pressure of the water system. If the relieving
point of the water heater's temperature-pressure relief valve is
reached, the valve wil! relieve the excess pressure. The
temperatureopressure relief valve is not intended for the
constant relief of thermal expansion. This is an unacceptable
condition and must be corrected.
It is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an
expansion tank to relieve the pressure built by thermal
expansion in the water system. Thermal expansion tanks are
available from Sears stores and through the Sears Service
Centers. Contact the local plumbing inspector, water supplier
and/or the Sears Service Center for assistance in controlling
these situations.
Therma! Expansion Tank Specifications
Model
Number
153.331020
153.331050
Tank Dimensions
Capacity in inches
in Gallons _m Length
2 8 (203 ram) 12-3/4 (323 ram)
5 11(279 mm) 14-3/4 (375 mm)
Pipe
Fitting
On Tank
3/4" Mate
3/4" Mate
{2)
PRESSURE GAUGE
RECOMMENDED mNSTALLATION
IVERTICAL MOUNTING)
WATER HEATER
COLD WATER
INLET FITTING
PRESSUREGAUGE #1LETCOLD
ALTERNATE RECOMMENDED INSTALLATION
FIGURE 43.
STRANGE SOUNDS
Possible noises due to expansion and contraction of some
metal parts during periods of heat-up and cool-down do not
represent harmful or dangerous conditions.
FLOOR, CEILING JOIST, ETC.
_ STRAPPING (3)
_%"(1) VALVEWITHBY=PASS
EXPANSmON /
TANK
!2) / f
{HORIZONTAL MOUNTING)
ruNLET COLD
WATER SHUT-OFF
PRESSURE
REDUCING
WATER SHUT-OFF
Operationa_ Conditions
SMELLY WATER
Expansion Tank Sizing Chart
h[et*
Water
Pressure
Expansion
Tank
Capacity
Needed
40psi
50psi
60psi
70psi
80psi
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
Water Heater Capacity (Gallons)
30 40 50 66 82
2 2 2 5 5
2 2 2 5 5
2 2 5 5 5
2 2 5 5 5
2 5 5 5 5
E
In each glass-lined water heater there is installed one anode
rod (see parts section) for corrosion protection of the tank.
Certain water conditions will cause a reaction between this
rod and the water. The most common complaint associated
with the anode rod is one of a "rotten egg smell'L This odor is
derived from hydrogen sulfide gas dissolved in the wateE The
smell is the result of four factors which must all be present for
the odor to develop:
A A concentration of sulfate in the supply water.
B. Little or no dissolved oxygen in the water.
C. A sulfate reducing bacteria within the water heater. (This
harmless bacteria is nomtoxic to humans.)
23

D.Anexcessofactivehydrogeninthetank.Thisiscausedby
corrosionprotectiveactionoftheanode.
Smellywatermaybeeliminatedorreducedinsomewater
heatermodelsbyreplacingtheanoderod(s)withoneofless
activematerial,andthenchlorinatingthewaterheatertankand
al!hotwaterlines.ContactthelocalSearsServiceCenterfor
furtherinformationconcerninganAnodeReplacementKit
#9001453andthisChlorinationTreatment.
If smellywaterpersists,afteranodereplacementand
chlorinationtreatment,wecanonlysuggestthatcontinuous
chlorinationandfilteringconditioningequipmentbeconsidered
toeliminatethewaterproblem.
DonotremovetheanodeJeavingthetankunprotected.By
doingso,aHwarrantyonthewaterheatertankisvoided.
"AIR"mNHOTWATERFAUCETS
Explosion Hazard
Before removing any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
_, Failure to do this could result in
death, serious bodily injury, or
property damage
1. Before beginning, turn "OFF" electrical power supply to the
water heater.
1
- Flammable hydrogen
gases may be present.
- Keep all ignition sources
away from faucet when
turning on hot water.
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely
flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened for several minutes at the kitchen sink before any
electrica! appliances which are connected to the hot water
system are used (such as a dishwasher or washing machine).
If hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open flame
near the faucet at the time it is open.
RUMBUNG NO{SE
In some water areas, scale or mineral deposits will build up
on your heating elements. This buildup will cause a rumbling
noise. Follow "Element Cleaning/Replacement" instructions
to clean and replace the elements.
HIGH TEMPERATURE SHUT OFF SYSTEM
The water heater has a high limit shut off system with a reset
button located on the thermostat.
Follow the resetting instructions which refer to the high limit
behind the access panel.
NOTE: If your water heater is connected to an "Off Peak" Clock,
and uses the "3 wire lead" wiring diagram in the "Wiring
Diagram" section, then the water heater will have a high limit
on both the upper and lower thermostats. Follow the instructions
to reset the high-limit behind the upper and lower access panels.
FIGURE 44.
2. Remove the two screws securing the access panel and
remove panel.
3. Remove the insulation block and pad.
4. Reset the high limit by pushing in the red button marked
"RESET".
RESET
FIGURE 45.
5. Replace the insulation block and pad so that it completely
covers the thermostat and element.
6. Replace the access panel.
7. Turn "ON" electric power to the water heater.
If the high limit must be reset again, cal! Sears Service
Department to find out why the high limit turned "OFF" the electric
power
NOT ENOUGH OR NO HOT WATER
In a new installation, the water heater may not be properly
connected. Make sure the cold water supply valve is open.
Review and check piping installation. Make sure that the
cold water line is connected to the cold water inlet to the
water heater and the hot water line to the hot water outlet
on the water heater.
24

2_
Make sure the electrica! supply to your water heater is
"ON"_
3.
Check for loose or blown fuses in your water heater circuit.
Circuit breakers weaken with age and may not handle
their rated load and should be replaced.
4,
Make certain the disconnect switch, if used, is in the 'ON"
position.
5.
Check to see the electric service to your house has not
been interrupted. If this is the case, contact the electric
company.
6,
Is the thermostat set to the desired temperature? See
"Temperature Regulation" section.
7,
If you had experienced very hot water and now no hot
water, the problem may be due to the high temperature
Leakage Checkpoints
Read and understand instruction
manual and safety messages
before installing, operating or
servicing this water heater
Fai0ure to follow instructions and
safety messages could result in
death or sedous injury.
Hnstruction manual must remain
with water heater.
Read this manual first. Then before checking the water heater
make sure the electric supply has been turned 'OFF", and never
turn the electric supply "on" before the tank is completely full of
water.
Use this guide to check a "Leaking" water heater. Many
suspected ' Leakers" are not leaking tanks. Often the source of
the water can be found and corrected.
shut off system. See "High Temperature Shut Off System"
in the 'Troubleshooting" section.
8. During very cold weather, the incoming water will also be
colder and it will require a longer time to become heated.
g,
The hot water usage may exceed the capacity of the water
heater. If so, wait for water heater to recover after abnormal
demand. Also examine pipes and faucets for possible
water leaks.
10. If you can not determine the problem, then call the Sears
Service Department.
WATER JSTOO HOT
Adjust the thermostat to a lower setting. See the 'Temperature
Regulation" section.
Small amounts of water from the temperature-pressure
relief valve may be due to thermal expansion or high water
pressure in your area.
*The temperature-pressure relief valve may be leaking at
the tank fitting.
The element may be leaking at the tank fitting.
Before removing any access
panels or servicing the water
heater, make sure the dectrical
supply to the water heater is
turned "OFF"
_' Failure to do this could result in
death, serious bodily injury, or
property damage
If you are not thoroughly familiar with electric codes, the water
heater, and safety practices, contact your local Sears Service
Center to check the water heater.
mmproper installation and use may result
in property damage.
Fill tank with water before operation
Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with water. The water must flow from the hot
water faucet before turning "ON" power.
*Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
Turn electrical power "OFF", remove access panel and
insulation cap with handle. If leaking around element, follow
proper draining instructions and remove element. Reposition
or replace gasket on element. Place element into opening and
tighten securely. Then follow 'Filling the Water Heater"
instructions in the 'Installation Instructions" section.
Water from drain valve may be due to the valve being opened
slightly
*The drain valve may be leaking at the tank fitting.
Water in the heater bottom the floor be from
water
or on
may
condensation, loose connections or the temperature-
pressure relief valve. DO NOT replace the water heater until
a full inspection of al! possible water sources is made and
necessary corrective steps taken.
Leakage from other appliances, water lines, or ground seepage
should also be checked.
25

Note:Tocheckwherethreadedportionenterstank,insert
cottonswabbetweenjacketopeningandfitting.Ifcottonis
wet,follow"Draining"instructionsinthe"Serviceand
Maintenance'section and then remove fitting. Put pipe dope
or teflon tape on the threads and replace. Then follow "Filling
the Water Heater" instructions in the "Installation
Instructions" section.
FIGURE 46.
26

KENMORE POWER MISER TM 9
ELECTRIC WATER HEATERS
153.329262 38 Gallon Short
153.329263 38 Gallon Short
NOTE:A
UPPER ELEMENT: These water heaters are equipped with 3800 watt
elements
LOWER ELEMENT: These water heaters are equipped with factory installed
convertible elements, which can be operated at 3800 watts or 5500
watts. Convertible elements are not offered as replacement parts.
ELEMENT ORDERING }NFORMATiON: If a replacement 3800 watt, 240
volt element is needed, order part no 42 31906 replacement element.
If, at the time of installation, the water heater was converted to operate at
5500 watts, order part no 42 31908 replacement element. (See model
rating plate" If Converted" box).
NOTE:B
These water heaters are equipped with a Rote-Swirl TM dip tube to
retard a build-up of dissolved solids
Key
No. Part Description
1 Buss Bar Kit
2 Drain Valve
3 Drain Valve Washer (! 7/32"xl 3/64"xl/8" thick)**
4 Element Gasket
5 Element Gasket
6 LowerAccess Panel
7 Lower Element* (See NOTE "A" above) 3800 Watt
5500 Watt
8 Lower Thermostat w/Hi-Limit* (3 wire lead models) 11
#9 Manual
10 Model Rating Plate 1.
11 Nipple (Cold Inlet! w/Heat Traps
12 Nipple (Hot Outlet) w/Heat Traps***
13 Primaq!Anode Rod
14 Roto-Swirl TM Dip Tube (See NOTE "B" above)
15 SecondaryAnode Rod w/Nipple (Hot Outlet) w/HT
16 Temperature Pressure Relief Valve*
17 Terminal Cover
18 Terminal Cover
19 Terminal Cover
20 Thermostat Bracket
21 Thermostat Bracket
22 U}2#er Access Panel
23 Upper Element* (See NOTE "A" above)
24 Upper Thermostat w/Hi Limit*
25 2 Pole Thermostat* (Two wire lead models) 1"1"
153.329262 153,329263
184726o001 184726-001
Model No,
9001591 9001591
9003464 9003464
9001584 9001584
9000308 9000308
9000308 9000308
9002671 9002671
4231906 4231906
4231908 4231908
42 31918
0270182 0270182
9003909 9003909
9003909
9003487 9003968
9001986 9001986
9004268
4233086 4233086
9002303
9002303 9002303
9002276
9000309 9000309
9000309 9000309
9002671 9002671
4231906 4_231906
4231917 4231917
4231919
* These parts are also available at most Sears retail stores. ** Also available at most hardware stores. *** When secondary anode w/nipple
not provided. 1" Replaced only on return of damaged plate. 1"1"Refer to Wiring Diagram section for verification. #Not illustrated.
Now that you have purchased this water heater, should a need ever
exist for repair parts or service, simply contact any Sears Service
The model number of the water heater will be found on the model rating
plate located near the access panel.
Center or call I=800-4=M%HOME (! =800o469=4663). Be sure to provide
all pertinent facts when you call or visit.
WHENORDERmNGREPAIRPARTS,ALWAYSGIVETHEFOLLOWING
INFORMATION:
All Parts listed may be ordered from any Sears stores and by calling
1=800-366-PART (1=800-366-7278).
If the parts you need are not stocked locally, your order will be
electronically transmitted to a Sears Repair Parts Distribution Center
for handling.
Model Number • Part Number
Serial Number
Part Description
THIS _SA REPAIR PARTS UST, NOT A PACKAGmNG LIST,
27

KEN_tvIOREPOWER MISER TM 9
ELECTRIC WATER HEATERS
153.329360 30 Gallon
153.32936! 30 Gallon
153.329460 40 Gallon
153.32946! 40 Gallon
153.329560 55 Gallon
NOTE:A
UPPER ELEMENT: These water heaters are equipped with 3800 watt
elements
LOWER ELEMENT: These water heaters are equipped with factory
installed convertible elements, which can be operated at 3809 watts or
5500 watts Convertible elements are not offered as replacement parts.
ELE_,,'_ENT ORDERING }NFORMATION: if a replacement 3800 watt, 249
volt element is needed, order part no. 42 31906 replacement element.
If, at the time of installation, the water heater was converted to operate
at 5500 watts, order part no 42 31908 replacement element. (See model
rating plate" if Converted" box)
NOTE:B
These water heaters are equipped with a Roto-Swirl TM dip tube to
retard a build-up of dissolved solids.
Key
No. Part Description 153.329360
1 Buss Bar Kit 900!591
2 Drain Valve 9003911
3 Drain Valve Washer (17/32"x! 3/64"x!/8" thick) 900! 584
4 Element Gasket 9000308
5 Element Gasket 9000308
6 Lower Access Panel 9002671
7 Lower Element* (See NOTE "A" above) 3800 Watt 42 31906
5500 Watt 42 31908
8 Lower Thermostat w/Hi-Limit* (3 wire lead models) 1-1-
#9 Manual 184726°001
10 Model Ratin_ Plate 1- 0270182
11 Nipple (Cold Inlet) w/Heat Traps 9003931
12 Nipple (Hot Outlet) w/Heat Traps*** 9003931
13 Primar},Anode Rod 9003927
14 RotooSwirl TM Dip Tube (See NOTE "B" above) 9003501
15 Secondar)/Anode Rod w/Nipple (Hot Outlet)w/HT
16 Temperature Pressure Relief Valve* 42 33086
17 Terminal Cover 9002276
18 Terminal Cover 9002303
19 Terminal Cover& Barrier
20 Thermostat Bracket 9000309
21 Thermostat Bracket 9000309
22 Upper Access Panel 9002671
23 Upper Element* (See NOTE "A" above) 42 31906
24 Upper Thermostat w/Hi Limit* 42 31917
25 2 Pole Thermostat* (Two wire lead models) 1,1 42 319!9
153.329361
9001591
9003911
9001584
9000308
9000308
9002671
4231906
4231908
4231918
184726°00!
0270182
9003931
9003927
9003501
9003937
4233086
9002303
9002303
9000309
9000309
9002671
4231906
4231917
Model No.
153.329460
9001591
9003911
9001584
9000308
9000308
9002671
4231906
4231908
184726o001
0270182
9003931
9003909
9003928
9003929
4233086
9002276
9002303
9000309
9000309
9002671
4231906
4231917
4231919
153,329461
9001591
9003911
9001584
9000308
9000308
9002671
4231906
4231908
4231918
184726-00!
0270182
9003931
9003928
9003929
9003930
4233086
9002303
9002303
9000309
9000309
9002671
4231906
4231917
153329560
9001591
9003911
9001584
9000308
9000308
9002671
4231906
4231908
184726-001
0270182
9003931
9003931
9003928
9003919
4233086
9002276
9002303
9000309
9000309
9002671
4231906
4231917
4231919
* These parts are also available at most Sears retail stores. ** Also available at most hardware stores. *** When secondary anode w/nipple
not provided. 1" Replaced only on return of damaged plate. 1-1-Refer to Wiring Diagram section for verification. #Not illustrated.
Now that you have purchased this water heater, should a need ever The model number of the water heater will be found on the model rating
exist for repair parts or service, simply contact any Sears Service
plate located near the access panel.
Center or call 1-8O0o4-MY-HOME (1°800-46%4663). Be sure to provide
all pertinent facts when you call or visit.
WHEN ORDERING REPAmRPARTS, ALWAYS GroVETHE FOLLOWING
INFORMATION:
All Parts listed may be ordered from any Sears stores and by calling
1°800°366°PART (1°800°366°7278).
ModeINumber • Part Number
Serial Number
If the parts you need are not stocked locally, your order will be
Part Description
electronically transmitted to a Sears Repair Parts Distribution Center
for handling.
THINSmSA REPAIR PARTS LIST, NOT A PACKAGING UST.
28

KENMORE POWER MISER TM 9
ELECTRIC WATER HEATERS
153.329561 55 Gallon
153.329660 66 Gallon
153.329661 66 Gallon
153.329860 80 Gallon
153.329861 80 Gallon
NOTE:A
UPPER ELEMENT: These water heaters are equipped with 3808 watt
elements.
LOWER ELEMENT: These water heaters are equipped with factory installed
convertible elements, which can be operated at 3800 watts or 5500 watts
Convertible elements are not offered as replacement parts
ELEMENT ORDERING BNFORMATION: if a replacement 3800 watt, 240 volt
element is needed, order part no. 42 31906 replacement element. If, at the
time of installation, the water heater was converted to operate at 5500 watts,
order part no 42 31908 replacement element. (See model rating plate" If
Converted" box)
NOTE:B
These water heaters are equipped with a Roto-Swirl TM dip tube to retard a
build-up of dissolved solids
Key
No. Pals Description 153.329561
1 Buss Bar Kit 900159!
2 Drain Valve 9003911
3 Drain Valve Washer (17/32"x13/64"xl/8" thick) 9001584
4 Element Gasket 9000308
5 Element Gasket 9000308
6 Lower Access Panel 9002671
7 Lower Element* (See NOTE "A" above) 3800 Watt 48231906
5500 Watt 42 31908
8 Lower Thermostat w/Hi-Limit* (3 wire lead models) lt 48231918
#9 Manual 184726-001
10 Model Rating Plate 1. 0270182
11 Nipple {Cold Inlet) w/Heat Traps 9003931
12 Nipple (Hot Outlet) w/Heat Traps***
13 PrimaryAnode Rod 9003729
14 Roto-Swirl Dip Tube (See NOTE"B" above) 9003919
TM
15 Secondary Anode Rod w/Nipple (Hot Outlet) w/HT 9003937
16 Temperature Pressure Relief Valve* 48233086
17 Terminal Cover
18 Terminal Cover 9002303
19 Terminal Cover & Barrier 9002303
20 Thermostat Bracket 9000309
21 Thermostat Bracket 9000309
22 UpperAccess Panel 9002671
23 Upper Element* {See NOTE "A" above) 42 31906
24 Upper Thermostat w/Hi Limit* 4231917
25 2 Pole Thermostat* (Two wire lead models) 1!
153.329650
9001591
9003911
9001584
9000308
9000308
9002671
4.8231906
4231908
184726-001
0270182
9003915
9003915
9003729
9003933
4.8233086
9002276
9002303
9000309
9000309
9002671
4_£231906
4.8231917
4231919
Model No.
153.329661
9001591
9003911
9001584
9000308
9000308
9002671
4231906
4231908
4231918
184726-001
0270182
9003915
9003729
9003933
9003934
4233086
9002303
9002303
9000309
9000309
9002671
4231906
4231917
153.329860
9001591
9003911
9001584
9000308
9000308
9002671
4.8231906
4231908
184726o001
0270182
9003936
9003936
9003932
9003933
4.8233086
9002276
9002303
9000309
9000309
9002671
4_£231906
4.8231917
4231919
153329861
9001591
9003911
9001584
9000308
9000308
9002671
4231906
4231908
4.8231918
184726=001
0270182
9003936
9003932
9003933
9003935
4233086
9002303
9002303
9000309
9000309
9002671
4_£231906
4231917
* These parts are also available at most Sears retail stores. ** Also available at most hardware stores. *** When secondary anode w/nipple
not provided. 1" Replaced only on return of damaged plate. 1"1" Refer to Wiring Diagram section for verification. #Not illustrated.
Now that you have purchased this water heater, should a need ever
exist for repair parts or service, simply contact any Sears Service
The model number of the water heater will be found on the model rating
plate located near the access panel.
Center or call 1-800-4-MY-HOME (! -800o469-4663). Be sure to provide
all pertinent facts when you call or visit.
WHENORDERmNGREPAIRPARTS,ALWAYSGIVETHEFOLLOWING
INFORMATION:
All Parts listed may be ordered from any Sears stores and by calling
1-800-366-PART (1-800-366-7278).
If the parts you need are not stocked locally, your order will be
electronically transmitted to a Sears Repair Parts Distribution Center
for handling.
Model Number , Part Number
Serial Number
Part Description
THiS IS A REPAmRPARTS UST, NOTA PACKAGmNG L_ST.
29

30

31

9 oYEAR LmMITEBWARRANTY ON WATER HEATER
For nine years from the date of purchase, if this water heater is installed and operated in a single-family home in
accordance with the owner's manual instructions and al! Ioca! applicable plumbing codes, Sears will:
1. Supply free water heater parts for those that are defective in material or workmanship.
2. Supply a free water heater for one that develops a leak.
For the second through ninth year from the purchase date, you must pay the labor cost for installation of parts or water
heater.
For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for
two years. During the second year you must pay the labor cost for parts or water heater installation.
loYEAR EXCLUSmVE KENMORE LABOR WARRANTY
For the first year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for
defective ones or a new water heater for one that develops a leak.
WARRANTY SERVICE
To obtain warranty service, call 1-800-4-MYoHOME ® (1-800-469-4663).
This warranty applies only while this product is in use in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
SEARS, ROEBUCK AND CO., Dept.817WA, Hoffman Estates, _L 80179
The price of your water heater does not include a free checkup service ca[[. On water heater installations arranged by Sears,
Sears warrants the installation.
A charge will be made on service calls due to poor or incomplete installation. These include:
a. Adjusting thermostat b. Leaks in pipes or fittings c. Condensation
MASTER PROTECTION AGREEMENTS
Congratuiations on making a smart purchase. "four new
Kenmore ® product is designed and manufactured for years of
dependable operation. But like al! products, it may require
preventive maintenance or repair from time to time. That's when
having a Master Protection Agreement can save you money and
aggravation.
Purchase a Master Protection Agreement now and protect yourself
from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of
your new product. Here's what's included in the Agreement:
Expert Service by our 12,000 professional repair specialist.
Unlimited service and no charge for parts and labor on all
covered repairs.
"Noolemon" guarantee - replacement of your covered product
if four or more product failures occur within twelve months.
Product replacement if your covered product can't be fixed.
• Annual Preventive Maintenance Check at your request - no
extra charge.
Call 24 hours a day, 7 days a week (U.S.A. and Canada)
The model number of your water heater is found on the model rating plate on the front of the water heater.
Fast heJp by phone =phone support from a Sears technician
on products requiring in-home repair, plus convenient repair
scheduling.
Power surge protection against electrical damage due to
power fluctuations.
Rental reimbursement if repair of your covered product takes
longer than promised.
Once you purchase the Agreement, a simple phone cal! is all
that it takes for you to schedule service. You can call anytime day
or night, or schedule a service appointment omline.
Sears has over 12,000 professional repair specialists, who have
access to over 4.5 million quality parts and accessories. That's
the kind of professionalism you can count on to help prolong the
life of your new purchase for years to come. Purchase your Master
Protection Agreement today!
Some [imitations and exclusions apply. For prices and
additional information call 1o800o827o6655.
SEARS mNSTALLATION SERWCE
For Sears professionai Instah'ation of home appliances, garage
door openers, water heaters, and other major home items, in
the U.S.A. call 1oS00o4oMYoHOME ®,
For in-home major brand repair service
1-800-4-MY-HOM
(1°800=489=4883}
www,eeare,eom