FULL ONE YEAR WARRANTY ON HUMIDIFIER
If within one (1) year from the date of purchase, this humidifier fails due to
a defect in material or wQrkmanship, Sears will repair it, free of charge. If
within two (2) years from the date of purchase, the motor fails due to
defect in material or workmanship, Sears will repair it free of charge.
This warranty service is available by simply returning the humidifier to the
nearest Sears Service Center/Department throughout the United States.
This warranty applies only while this product is used in the United States.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
Sears, Roebuck and Co., 13/8t7 WA, Hoffman Estates, IL 60179 _1
GENERAL SAFETY INSTRUCTIONS
Safety Signal Words
DANGER: means if the safety information
is not followed someone will be seriously
injured or killed.
WARNING: means if the safety informa-
tion is not followed someone could be
seriously injured or killed.
CAUTION: means if the safety informa-
tion is not followed someone may be seri- or tip humidifier while unit is running,i, i
ously injured. _ _-8:'To"reduce'the'risk" of'datl"Pa_'tO
1. To reducethe risk offire or shock hazard, humidifier,unpluQ humidifier, wher_',:f
plug humidifier directly into a 120V, A.C. "........ w'_a'fE_se"-"_olrsar"_"_"_=_.my_,_'r,"when "
electrical outlet. Do not use extension the humidif._,L_J_t,i_'il_v_. _-_] -,,-.-..,_-.
cords.
2. Keep the electric cord out of traffic
areas. To reduce the risk of fire haz-
ard, never put the electric cord under
rugs, near heat registers, radiators,
stoves or heaters.
3. Always unplug the humidifier before
moving it, removing the housing sec-
tion, before cleaning, or whenever the
humidifier is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the
humidifier.
6. Never use your humidifier while any pa_
is missing or damaged in any rnanne_,_
7. To reduce the risk of electrical h_zard
....... 0_:damage,.t_.humidiSer._._ot.t_, ij_l_:?
9. To reduce the risk of accidental el_ctri,
...... -cal_shock';,'do'notloucITt_d or '
controls with wet hands. _ ,_ ,"_
10. Note the warning label shown below •
..---and on-the humidifier: .............
WARNING: To reduce the risk of firs, I
electric shock, or injury always unplug
before filling, servicing or cleaning.
Table'of Contents
I
Warranty Information ............................. 2
General Safety Instructions ................... 2
To Save a Service Call ........................... 2
Know Your Humidifier ............................ 3
Humidifier Operations ............................ 4
Assembly ............................................... 4
Location Instructions ........................... 4-5
Electrical Hook-Up ................................. 5
To Save a Service Call
Check following if your humidifier will not
operate_
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
Water Fill ............................................ 5-6
Operating Humidifier Controls ............... 7
Using Your Humidifier ............................ 8
Operating Tips for Best Performance.... 8
Replacement and Care of Filters ...... 9-10
Cleaning of Humidifier ................... 11-12
Trouble Shooting .................................. 13
Repair Parts ................................... 14-15
3. Is airflow control in operating position?
4. Is humidity control set high enough?
5. Is the cabinet setting on a level surface?

Humidifier Operations
Your new Sears humidifier is designed to
satisfy home humidity requirements
through the principle of evaporation of
water into the air.
After water is added to the bottles, the fil-
ters begin to soak up the water and
become totally saturated in approxi-
mately 30 minutes. Air is drawn in from
the rear of the humidifier, then passes
through the filters by means of two circu-
lation fans. As air passes through the fil-
ters, moisture is absorbed into the air and
then released through the top of the
humidifier. This moist air is released in the
form of vapor. No water droplets will enter
the home. All evaporation into the air
takes place in the humidifier, which
means that the residue left by evaporating
water is not passed into the home, but
remains in the filter.
CAUTION: Use only 42-14900 EPA
Registered Bacteriostat available
from SEARS Retail store. Under no
circumstances should you use water
treatment products designed for
Roto belt or Ultrasonic humidifiers.
Humidified Air is
Then Released
Through the Top
Dry Air Enters ..:_-;_ --:..".
Through the
Rear
CAUTION: .Keep your humidifier
clean. While humidifiers do not cause
colds, some studies suggest that
dirty humidifiers can cause cold-like
symptoms in some people. To reduce
the risk of this, we recommend you
clean your humidifier weekly with
Humidifier Cleaner 42-14713 and use
Bacteriostat 42-14900. These are
available at your local Sears store.
Assembly
Your new Sears Kenmore humidifier is
completely assembled for you to use.
Remove the packaging material from
inside your humidifier and follow the
Location Instructions
WARNING: For your own safety, do
not use humidifier if any parts are
damaged or missing.
Step I
Place humidifier on a fiat level _urface in
area of house where most humidity is
needed, or one which would likely result in
moist air being circulated throughout the
house such as near a cold air return.
P.lacing the unit level is very important if
the humidifier is located on carpeting.
NOTE: The 13 gallon humidifier contains
water bottles, the weight of the bottles in
the front of the cabinet may sink the cast-
ers deeper in the carpet. This will keep
the wate_evel forward in the cabinet. The
water level float (located at the rear of the
instructions of this owner's manual for
proper usage. The packaging material is
located under the fan assembly. Remove
the packaging material and discard.
cabinet) may not sense the water and the
fill light will be on and the unit will not
I
energize, if this happens, the unit will
need to be leveled in order for the humidi-
fier to be energized.
NOTE: It may be necessary to purchase
leveling coasters from your local hardware
store. The coasters should be positioned
under the front two casters of the humidifier.
Moist air (humidity) produced will disperse
into the whole house, but area closest to
unit will have the highest humidity. If the
unit is positioned close to a window, con-
densation may form on the window pane.
If this is not appropriate the unit should be
repositioned in another location.
4

Location Instructions (continued)
NOTE: Due to release of cool, moist air
from humidifier, it is best to direct air away
from home thermostat and hot air regis-
ters. It is best to position humidifier next to
an inside wall. Hot air registers and cold
air from outside walls can affect the effi-
ciencies of the controls. Unit should not
be placed where warm air from a hot air
register blows directly on unit.
Step 2
The humidifier should be positioned with
the back (cord exit side), at least 2 inches
away from the wall. Air needs to enter
through louvers in the rear panel in order
for the humidifier to operate at peak effi-
ciency.
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in
the location desired, preferably on inside
wall. Plug in the electrical cord.
At Least
2" From Wall
or shock hazard, humidifier should
be plugged into a 120V A.C. outlet.
I ARNING: To reduce the risk of fire
Do not use extension cords.
Water Fill
WARNING: To reduce the risk Of
shock, always unplug humidifier
before filling, cleaning, or servicing.
W'A]_I_ING: To reduce the risk of fire
or shock hazard, do not_pour or spill
water into control or motor area.
Close the control cover. If controls
get wet, let them dry completely and
have unit checked by authorized
service personnel before plugging
in.
This humidifier is designed to be used
with the two water bottles that are located
under the pivoting lid.
Op_the pivoting lid of the humidifier.
Remove the water bottles, lift them
straight up and out of the cabinet.
Pivoting Lid Removed for Clarity
5