Kenmore 11633921301, 11633920301, 11633920300, 11633921300 Owner’s Manual

Owner's Manual
Manual Del Propietario
Vacuum Cleaner
Aspiradora
Model, Modelo
CAUTION:
Read and follow all
use of this product.
116.33920
116.33921
CUIDADO: Lea y sigua todas las
instrucciones de operaci6n y seguridad antes del uso de
este producto.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
Impreso en Mexico
Part No. CO1ZBKH30UOO-8192437 Printed in Mexico
Before Using Your New Vacuum ...... 2 Kenmore Vacuum Cleaner Warranty... 2
Important Safety Instructions ......... 3
Parts and Features .................. 4
Assembly Instructions ............. 5-6
Operating Instructions ............... 7
Getting Started ...................... 7
Pile Height Selection and Setting ........ 7
Off/Floor/Carpet Switch ............... 8
Variable Speed Control ................ 8
Releasing the Handle ................. 8
Auto Reverse ....................... 9
Attachments .................... 10-12
Attachment Use Chart ............... 12
Vacuuming Tips .................... 12
Performance Features ............. 13-14
Please read this guide. It will help you assemble and operate your new Kenmore vacuum in the safest and most effective way.
For more information about vacuum cleaner care and operation, call your nearest Sears store. You will need the complete model and serial numbers when requesting information.
Your vacuum's model and serial numbers are located on the Model and Serial Number Plate.
Vacuum Cleaner Care ............... 15
Vacuum Storage ................... 15
Cleaning Exterior and Attachments ...... 15
Dust Bin Cleaning ................ 16-17
Secondary Screen Cleaning ........... 17
Filter Changing/Cleaning ............. 18
Clog Removal ..................... 19
Light Bulb Changing ................. 20
Agitator Cleaning ................... 21
Valve Cleaning ..................... 21
Troubleshooting .................... 22
Requesting service ....... (back page)
Use the space below, to record the model number and serial number of your new Kenmore
vacuum.
Model No.
Serial No.
Date of Purchase
Keep this book and your sales check (receipt) in a safe place for future reference.
LIMITED ONE YEAR WARRANTY ON KENMORE VACUUM CLEANER This warranty is for one year from the date of purchase, and includes only private household
vacuum cleaner use. During the warranty year, when this vacuum cleaner is operated and maintained according to the owner's manual instructions, Sears will repair any defects in material or workmanship free of charge.
This warranty excludes vacuum bags, belts, light bulbs, and filters, which are expendable parts and become worn during normal use.
For warranty service, return this vacuum cleaner to the nearest Sears Service Center in the United States.
This warranty applies only while this product is in use in the United States. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., D/817 WA, Hoffman Estates, IL 60179
Yoursafety is importantto us.Toreducetherisk of fire, electrical shock, injury
to persons or damage when using your vacuum cleaner, follow basic safety precautions including the following:
Read this manual before assembling or
using your vacuum cleaner.
Use your cleaner only as described in
this manual. Use only with Sears recom- mended attachments.
To reduce the risk of electrical shock -
Do not use outdoors or on wet surfaces. Disconnect electrical supply before any
servicing or cleaning. Failure to do so
could result in electrical shock or person- al injury.
Always turn cleaner off before unplug-
ging. Do not unplug by pulling on cord. To
unplug, grasp the plug, not the cord. Do not use with damaged cord or plug.
tf cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a
Sears Service Center. Do not pull or carry by cord, use cord as
a handle, close door on cord, or pull cord around sharp edges or corners. Do
not run cleaner over cord. Keep cord
away from heated surfaces. Do not leave cleaner when plugged in.
Unplug from outlet when not in use and before servicing.
Do not allow to be used as a toy. Close attention is necessary when used by or
near children. Do not handle plug or cleaner with wet
hands. Agitator Brush may suddenly restart,
disconnect from power supply before servicing.
Do not put any objects into openings. Do not use with any opening blocked;
keep free of dust, lint, hair and anything
that may reduce air flow.
Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
Do not use cleaner without dust bin and/or filters in place.
Always clean the dust bin after vacuum- ing carpet cleaners or freshener, pow-
ders and fine dust. These products clog the filters, reduce airflow and can cause
damage to the cleaner. Failure to clean the dust bin could cause permanent
damage to the cleaner. Do not use the cleaner to pick up sharp
hard objects, small toys, pins, paper clips, etc. They may damage the clean-
er or dust bin. Do not pick up anything that is burning
or smoking, such as cigarettes, matches, or hot ashes.
Do not use cleaner to pick up flammable or combustible liquids (gasoline, clean-
ing fluids, perfumes, etc.), or use in areas where they may be present. The
fumes from these substances can create a fire hazard or explosion.
Use extra care when cleaning on stairs. Do not put on chairs, tables, etc. Keep
on floor. You are responsible for making sure that
your vacuum cleaner is not used by any- one unable to operate it properly.
SAVE THESE INSTRUCTIONS
Proper assembly and safe use of your vacuum cleaner are your responsibilities. Your cleaner is
intended only for household use. Read this Owner's Manual carefully for important use and safety
information. This guide contains safety statements under warning and caution symbols. Please
pay spedal attention to these boxes and follow any instructions given. WARNING statements alert you to such dangers as fire, elec'cical shock, burns and personal injury. CAUTION statements alert
you to such dangers as personal injury and/or property damage.
3
Item Part No. Part No.
In U.S. In Canada
Exhaust Filter 20-86889 20-86889C Headlight Bulb 20-5248 20-5248C
Primary Filter 20-82720
It is important to know your vac- uum cleaner's parts and fea-
tures to assure its proper and safe use. Review these before
using your cleaner.
Auto-Reverse
Handle
Power
Lower
Hook
Combination Brush
Quick
Cord Hook
Hose
Handl,
On/Off Switch
Variable
Sp
Control
Nozzle Hose
Button
Handle
Handi-Mate Jr. ®
Exhaust Filter
Dus Latch
Dust Bin
Nozzle
_'_Handle Release
Pedal
Crevice Tool
Protector
Guard
Dirt
Nozzle Hose
Sensor Indicator
Pile Height Sensitivity Adjustment Switch
BONUS HOSE KITS
Bonus Hose
II(l[l[ll[ll[llltll[lll[l(tL
4
yT, WARNING I
Electrical Shock Hazard Do not plug into the electrical sup-
ply until the assembly is complete. Failure to do so could result in elec-
trical shock or injury.
Before assembling vacuum, check the
PACKING LIST on the cover of the separate Repair Parts List. Use this list to verify that
you have received all the components of your new Kenmore vacuum.
Remove tape from filter cover and dust bin
latch.
HANDLE ASSEMBLY
Remove the two (2) handle screws located
in the body.
Position the handle as shown in the illustra-
tion below.
When installing the handle, firmly press the
handle onto the body. Secure with handle screws provided.
Do not overtighten handle screws. Overtightening could strip the
screw holes. Do not operate the cleaner with-
out the screws in place.
CORD ASSEMBLY
Make sure the quick release upper cord
hook is in the upright position. Remove
the wire tie from the power cord.
Make sure the power cord is
placed into the lock- ing notch on the
body as shown. This helps keep the
power cord out from under the vacuum
cleaner agitator.
Power Cord
Handle
t
Electrical_ I
Connection _ _'1_ _ Tape
! _l_,:_Note: Do Not
Remove Tape
_ Body
Qu_kRe_ase UpperCord
Hook
H°°k!
Wrap the power cord around the upper and lower cord hooks and lock the power cord
plug onto the power cord.
5
EXTENSION HOSE ASSEMBLY
Connect extension hose to the valve assembly by aligning "J" slot with raised tab
on valve assembly. Push downward and
rotate clockwise to lock in place.
Place the crevice tool in rectangular slot on
back of wand holder.
Connect extension hose to telescopic wand by aligning "J" slot with raised tab on wand.
Push hose downward and rotate clockwise to lock in place.
Once extension hose is connected to the
telescopic wand, place the wand in the tele-
scopic location as shown.
For use of telescopic wand and extension hose see ATTACHMENTS section on
page 10
{
Raised Tab
Hose
Valve
Wand
Tool
Slot
Location
Remove the Handi-Mate Jr. ® from the plastic bag and insert Handi-Mate Jr. ® into
thevacuum cleaner as shown, then close the Handi-Mate Jr. ® storage cover.
Handi-Mate Jr.®
Handi-Mate Jr.® Storage Cover
6
OPERATING INSTRUCTIONS
Release Turn the quick
Upper Cord release upper
Hook cord hook to
either side and
down to release the
power cord.
Release the power cord plug from the power cord and pull the cord off the quick
release upper cord hook. Check to be sure the power cord is still locked into the lock in
the quick release upper cord hook. Note: To reduce the risk of electric shock,
this vacuum cleaner has a polarized plug, one blade is wider than the other.
This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit,
contact a qualified technician to install the proper outlet. Do not change the plug in any
way.
Plug the polarized power cord into a 120 Volt outlet located near the floor.
Personal Injury and Product Damage Hazard
DO NOT plug in if switch is in the
position. Personal injury or
Damage from cord to items in
To select a pile height setting:
Turn off cleaner. Select a pile height setting
by tilting the cleaner back until front wheels are lifted slightly off the floor.
Slide the adjustment lever to the correct setting.
SUGGESTED PILE HEIGHT SETTINGS You may need to raise the height to make
some jobs easier, such as scatter rugs and longer pile carpets. Suggested settings are:
HIGH: shag carpet, long pile, plush, scatter rugs.
MED: medium to long pile. LOW: short to medium pile.
EX LOW: very low pile and bare floors.
Note: When the pile height selection is set to EX LOW the pull forces will be stronger at the agitator. If the push/pull
forces are to aggressive or jerky a higher setting should be used.
!
'o WARNING
Personal Injury Hazard
To avoid personal injury, DO NOT
place hands or feet underneath
the unit when changing height setting.
HANDLE MOUNTED
To start the vacuum cleaner, slide the ON/OFF switch from the OFF position to the
FLOOR or CARPET position. To stop the
vacuum cleaner, slide the ON/OFF switch to the OFF position.
Note: Agitator will only turn when switch is
in CARPET mode.
CAUTION
CAUTION
Refer to your carpet manufacturers cleaning recommendations. Some more delicate carpets may require that
they be vacuumed with the agitator turned off, to prevent carpet damage.
OFF - turns both suction and brush motors off. FLOOR - turns on the suction motor only. In
this position the brush assembly does not revolve. Use this setting for cleaning hard-
wood and tile floors and when any attach- ments (tools) are used.
CARPET - turns on both the suction and the brush motors.
This vacuum cleaner is equipped with a variable power control which will allow you to select any cleaning power from low to high.
Do not allow vacuum cleaner to remain in one spot for any length of
time when the agitator is turning,
Damage to carpet may occur.
FLOOR Window
Low Suction Power
Set to LOW suction power for delicate fabrics such as draperies. Set to MAX or full power for more conventional carpet or
bare floor cleaning.
To set to MAX suction power, move the control knob fully to the right.
For deep cleaning set the power control to MAX.
Release the handle by pressing down on the handle release pedal with your foot and
pulling back and down on the handle with your hand.
Note: The agitator will not rotate if the vacu-
um cleaner is in the upright position.
Variable
Control Speed III
Note: When the varible power control is
set to LOW push/pull forces will increase.
8
The agitator Reverse
will rotate in the forward
direction
unless the Foward
handle is Auto Reverse
Handle
pulled in
reverse. Pulling the handle in reverse activates the
Auto-Reverse feature.
As the user tilts the handle to the use position the agitator rotates forward.
When the vacuum is pulled back, the Auto Reverse automatically reverses agitator
rotation, thus the agitator turns in reverse.
This feature ensures both sides of the carpet pile are effectively cleaned and
provides easier maneuverability.
As the vacuum is pushed forward, the agitator
rotates for- ward clean-
ing the car- pet fibers on
one side and helps to pro- /4.
pel the vacuum
",,r
]
forward. FORWARD
In certain applications it may be neces- sary to operate the vacuum cleaner with
the agitator rotating in the forward direc- tion only. To do this you will have to
depress and hold the handle locking but- ton located on top of the Auto Reverse
Handle.
To lock into
Auto Reverse
forward rotation
only, hold the button
Handle /
Button
/
until you
feel the
Foward
button lock into place.
It will be necessary to hold pressure on
the button to keep the Auto Reverse
Handle in the forward position. Simply release the handle locking button to return
to both forward and reverse motion.
Note: The agitator will not rotate if the vacu-
um cleaner is in the upright position.
When the vacuum is pulled back, the agitator switch-
es to a backward rota- ._ tion to clean
side of the
the other carpet fibers
and assists IIIIIIIIII IiitililLlltllllllllllllllll}llllJlllll_llllllllill the vacuum
in moving back- ward. REVERSE
TELESCOPING WAND WITH SUCTION CONTROL SLIDE
Handi-Mate Jr.®
Combination Extension Brush
Wand
Crevice
Identify each of the attachments shown above. Remove the upper encl of the hose that is
attached to the telescopic wand by grasping the hose collar, twisting and pulling straight
out. The attachments can now be added to the hose.
Note: The motor protector may open
when using attachments or when cleaning
new carpet, due to reduced airflow by the attachments themselves or by new carpet
fuzz filling the dust bin quickly. See the TROUBLESHOOTING section.
Remove
Telescopic Wand the tele-
scoping wand from
its storage position by
Crevice Tool twisting and
pulling out.
On the telescopic wand tum the locking ring
Suction
Wand _ _. Control Slide
Wand
Upper Wand
clockwise to the UNLOCK position.
Extend the wand to its full length. Turn the locking ring counter-clockwise to the LOCK position. Attach the extension wand onto the open end of the hose.
Remove the crevice tool from its storage
position on the wand holder. Attach crevice tool to the extension wand.
Note: When using attachments make
sure the cleaner is in the upright position and the selector window indicates
FLOOR.
WARNING
Electrical Shock And Personal Injury
Hazard Disconnect electrical supply before
servicing or cleaning the unit. Failure
to do so could result in electrical
shock or personal injury from cleaner suddenly starting.
CAUTION
When using attachments, be careful
not to overextend the stretch hose
when reaching. Trying to reach
hose stretch capability
cause the cleaner to tip over.
10
Suction
Control
Tab
To achieve maximum reach with the attach- ments, add the crevice tool to the end of the
wand by inserting and twisting slightly.
Handi-Mate Jr.®
For operation of Handi-Mate Jr.®
manual.see separate owners
TO STORE ATTACHMENTS
Remove combination brush from wand, hose or crevice tool. Snap into appropri-
ate storage location.
Handi-Mate
Handi-Mate Jr.®
Storage Cover
Combination Brush
Extension
TO OPERATE SUCTION
CONTROL SLIDE
When using attachments for cleaning draperies, small rugs with low pile and other
delicate items, twist the suction control slide to the open position. This will reduce suction
for ease of cleaning. The slide is located on the telescoping wand,
close to the hose.
Note: Return suction control
slide to the closed position
for normal cleaning.
If cleaner has poor cleaning performance, check to make sure the suction control slide
is closed.
Suction
Wand
Crevice Tool
Remove crevice tool from the wand by
twisting. Place in wand holder.
Unlock the wand by turning the wand lock- ing ring to the UNLOCK position.
Slide the lower wand into the upper wand.
Turn the wand locking ring to the LOCK
position. Reinsert the extension hose and telescopic
wand firmly into wand holder. Reinsert Handi-
Handi-Mate Jr.®
Mate Jr.® into the vacuum cleaner as
shown then
close the Handi- Mate Jr.® stor-
age cover.
Handi-Mate Jr.® Storage Cover
11
BONUS HOSE
Insert the two tabs on the end of the bonus hose into the two "J" shaped sJots on the
unit hose and twist to connect.
Unit Hose t_ Extension Hose
All attachments and the telescoping wand
can be attached to the open end of the hose.
ATTACHMENT
CREVICE TOOL
COMBINATION BRUSH
Furniture*
X X
When using the bonus hose or with the extension hose attached, the
cleaner should be on a solid surface on the same level or below the level
of the user's feet, DO NOT use the hoses when the cleaner is above the level of the user's feet.
CLEANING AREA
Between
Cushions*
X
Drapes*
X
Stairs
X X
Walls
X
Handi-Mate Jr. _
*Always clean attachments before using on fabrics.
Carpet edges Guide either side or the front of the nozzle
along a baseboard. The full width agitator brushes help remove dirt at carpet edges.
Stairs Put handle in full upright position. Place
pile height adjustment to HIGH when using attachments to prevent possible floor dam-
age. Use the crevice tool or combo brush. Set the Off/Floor/Carpet switch to Floor.
X
WARNING
Personal Injury Hazard Do not place cleaner on stairs. If it
falls, personal injury or property dam- age could result.
X
For best cleaning results, keep the airflow passage clear.
Occasionally, check each of the areas indi- cated for clogs. (see page 19)
Fr . CAUTION
Unplug the cleaner from the outlet
before checking.
12
MOTOR PROTECTOR
This vacuum has a motor protector by- pass valve which automatically opens to
provide cooling air to the motor when a clog prevents the normal flow of air to the
motor. If the by-pass valve opens to
prevent motor overheating and possible
damage to the vacuum, you win notice a
change of sound as air rushes through the valve opening.
Note: Do not block motor
protector.
Motor Protector
To correct problem: See the TROUBLE- SHOOTING section (page 22).
Note: The motor protector may open when using attachments or when cleaning new
carpet, due to reduced airflow caused by the attachments themselves or by new
carpet fuzz filling the dust bin quickly.
PERFORMANCE INDICATOR
When the unit is
normal air flow,
the light on the
performance indicator is off. _ -_-i&\_
The light comes
running with __ _ on whenever the _ p
airflow becomes erformanclndicatore blocked. If that
occurs, check the dust bin, clean or
replace clogged filters, and check other
possible clog locations shown in CLOG
REMOVAL (see page 19).
To correct problem: See the TROUBLE-
SHOOTING section (page 22).
Note: The light may also come on when
using attachments, due to reduced airflow
through the attachment. Note: In some cases, the performance
indicator light may not come on if the motor protector has opened.
AGITATOR THERMAL PROTECTOR This agitator has a thermal protector which
automatically trips to protect the agitator motor from overheating. If a clog prevents
the normal flow of air to the motor, the thermal protector turns the motor off
automatically to allow the motor to cool in order to prevent possible damage to the
vacuum. During this time the headlight and suction motor will remain on.
To correct problem: If this occurs, turn the vacuum off and unplug the power cord
from the outlet to allow the agitator to cool and the thermal protector to reset. Check
for and remove clogs, If necessary. Also check and replace any clogged filters. Wait approximately thirty (30) minutes and plug
the vacuum in and turn back on to see if the
motor protector has reset. "l_e motor protector will not reset if the vacuum is not
turned off even if the vacuum has cooled down. AGITATOR OVERLOAD PROTECTOR
The agitator has built-in protection against motor damage under severe jam conditions. If the agitator slows down or stops, the
agitator overload protector shuts off the agitator. The suction motor will continue to run.
To correct problem: Turn off and unplug vacuum, remove obstruction, then press
reset button. .IJ_
To reset: Push in the agitator "7"-_- ._-_/'f "N
overload protector _'/,,..._ _ /_
button. _/(_,,,_tI_,_ "_"
Agitator Reset
MOTOR THERMAL PROTECTOR
This vacuum has a thermal protector which
automatically trips to protect the vacuum from overheating. The thermal protector
turns the motor off automatically to allow the motor to cool in order to prevent possible
damage to the vacuum.
To reset:Turn off and unplug the vacuum
from the outlet to allow the vacuum to cool.
Check for andremove any clogs. Also
check and replace any cloggedfilters. Wait approximately50 minutesand plugthe
vacuum in and turn back on to see ifthe
thermal protectorhas reset. In some cases, the unitmay suddenlyrestart. DO NOT
leave unattended.
13
/
/
DIRT SENSOR
WARNING
The electronic dirt sensor is a feature which will detect particles as they pass through the
vacuum cleaner. The dirt sensor indicators and sensor
sensitivity switch are located on the front of the switch cover.
A red light Dirt
indicates dirt is Sensor being picked up by
the cleaner. A green light
indicates most of the dirt has
been picked up by the cleaner.
OPERATION
As you vacuum, the red indicator light will
come on and stay on as long as the sensor detects a high concentration of particles
passing through the cleaner. The green light indicates that most of the
cleaning is complete.
Electrical Shock And Personal Injury Hazard
Disconnect electrical supply before
servicing or cleaning the unit. Failure to do so could result in electrical
shock or personal injury from cleaner suddenly starting.
TO CLEANDIRT SENSOROPTICS
The dirt sensor optics consist of two optic cells located inside the valve assembly. Occasionally, it may become necessary to
clean the two optic cells to assure maximum performance. Clean optic sensors:
When the red light stays on continuously.
When the green light stays on continuously.
When dirt or dust adheres to the optic cells.
Whenever the dust cup is cleaned.
Extension\ \
Hose
Deep Cleaning )_ \ II_'_J_
Nozzle.ose
_.-._._ _v___ Valve
__l Assembly
The sensor switch al_ws you to select the sensitivity of the dirt sensor. The switch can
be set to HI (+) or LO (-) sensitivity.
Set the sensor switch to the HI (+) position when:
Cleaning bare floors.
Cleaning carpet with low pile height.
Set the sensor switch to the LO (-) position when:
Cleaning heavily soiled areas.
Cleaning carpet with deep pile.
Cleaning new carpets.
Even with the _------------------_---_1 sensor switch in Sensitivity
the LO (-) Switch_,
position, the dirt sensor will detect
carpet fuzz, especially on new carpet, which
may cause the red light to remain on longer than expected.
Sensor
To clean the sensor, remove deep cleaning nozzle hose at valve assembly by lifting
hose straight up. Remove extension hose
from the valve assembly by grasping hose
collar, twisting, and pulling straight off. Lay cleaner back by pressing the handle
release pedal (see Releasing the Handle page 8).
With the hoses removed you can
insert a cloth into the valve opening.
Wipe the optic
sensors with a soft, dry cloth.
Never use cleaners or liquids as they can help speed the recoating of the optic cells and make it necessary to clean them much
sooner than normal.
Valve
Return cleaner to the upright position. Re-
14 attach nozzle hose and extension hose.
Loading...
+ 30 hidden pages