DRYER USE ................................................................................. 16
Starting Your Dryer.................................................................... 16
KENMORE APPLIANCE AND OPTIONAL PEDESTAL
WARRANTY
ONE YEAR LIMITED WARRANTY
When installed, operated and maintained according to all
instructions supplied with the product, if this appliance fails due
to a defect in material or workmanship within one year from the
date of purchase, call 1-800-4-MY-HOME
repair.
If this appliance is used for other than private family purposes,
this warranty applies for only 90 days from the date of purchase.
THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL
AND WORKMANSHIP. SEARS WILL NOT PAY FOR:
1. Expendable items that can wear out from normal use,
including but not limited to filters, belts, light bulbs, and bags.
2. A service technician to instruct the user in correct product
installation, operation or maintenance.
3. A service technician to clean or maintain this product.
4. Damage to or failure of this product if it is not installed,
operated or maintained according to all instructions supplied
with the product.
5. Damage to or failure of this product resulting from accident,
abuse, misuse or use for other than its intended purpose.
6. Damage to or failure of this product caused by the use of
detergents, cleaners, chemicals or utensils other than those
recommended in all instructions supplied with the product.
7. Damage to or failure of parts or systems resulting from
unauthorized modifications made to this product.
®
to arrange for free
Stopping or Restarting Your Dryer............................................ 17
SERVICE NUMBERS ...............................................BACK COVER
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF
REMEDIES
Customer’s sole and exclusive remedy under this limited
warranty shall be product repair as provided herein. Implied
warranties, including warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period
allowed by law. Sears shall not be liable for incidental or
consequential damages. Some states and provinces do not allow
the exclusion or limitation of incidental or consequential
damages, or limitations on the duration of implied warranties of
merchantability or fitness, so these exclusions or limitations may
not apply to you.
This warranty applies only while this appliance is used in the
United States and Canada.
This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
Sears, Roebuck and Co.
Dept. 817WA, Hoffman Estates, IL 60179
Sears Canada Inc.
Toronto, Ontario, Canada M5B 2B8
2
PRODUCT RECORD
In the space below, record your complete model number, serial
number, and purchase date. You can find this information on the
model and serial number label located on the product.
Have this information available to help you obtain assistance or
service more quickly whenever you contact Sears concerning
your appliance.
Model number __ __ __. __________________________________________
PEDESTAL PRODUCT RECORD
In the space below, record your complete model number, serial
number, and purchase date. You can find this information on the
model and serial number label located on the product.
Have this information available to help you obtain assistance or
service more quickly whenever you contact Sears concerning
your pedestal.
Model number __ __ __. __________________________________________
Serial number __________________________________________________
Purchase date __________________________________________________
Save these instructions and your sales receipt for future
reference.
Serial number___________________________________________________
Purchase date __________________________________________________
Save these instructions and your sales receipt for future
reference.
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
follow instructions.
can be killed or seriously injured if you don't
You
instructions.
follow
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Clear the room, building, or area of all occupants.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
•
instructions.
If you cannot reach your gas supplier, call the fire department.
•
– Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
3
In the State of Massachusetts, the following installation instructions apply:
■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
■ If using a ball valve, it shall be a T-handle type.
■ A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
including the following:
■
Read all instructions before using the dryer.
■
Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
■
Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, drycleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or
explode.
■
Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
■
Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
■
Do not reach into the dryer if the drum is moving.
■
Do not install or store the dryer where it will be exposed
to the weather.
■
Do not tamper with controls.
To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
■
Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user-repair
instructions that you understand and have the skills to
carry out.
■
Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
■
Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
■
Clean lint screen before or after each load.
■
Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
■
The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
■
See installation instructions for grounding requirements.
SAVE THESE INSTRUCTIONS
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70.
4
INSTALLATION INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
■ 8" or 10" pipe wrench
■ 8" or 10" adjustable
wrench (for gas
connections)
■ Flat-blade screwdriver
■ Adjustable wrench that
opens to 1" (2.54 cm) or
hex-head socket wrench
(for adjusting dryer feet)
■ ¹⁄₄" nut driver or socket
wrench (recommended)
Parts supplied
Remove parts package from dryer drum. Check that all parts
were included.
4 Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a
pedestal.
Parts needed
Check local codes and with gas supplier. Check existing gas
supply, electrical supply and venting. Read “Electrical
Requirements,” “Gas Supply Requirements” and “Venting
Requirements” before purchasing parts.
■ For close-clearance installations between 28.65" (72.77 cm)
and 34.15" (86.74 cm), see “Plan Vent System” section for
venting requirements.
■ Level
■ Vent clamps
■ Knife
■ Pipe-joint compound
resistant to LP gas
■ Caulking gun and
compound (for installing
new exhaust vent)
■ Pliers
■ Tape measure
Optional Pedestal
Are you placing the dryer on a pedestal? You can purchase a
pedestal separately for this dryer. This pedestal will add about
10" (25.4 cm) to the height of your unit for a total height of
approximately 46" (116.8 cm).
For a garage installation, you will need to place the dryer at least
18" (46 cm) above the floor.
Optional pedestal
The pedestal is available in:
White - Part Number 46822
To order, call your local Sears store. For further information,
please call 1-800-4-MY-HOME
®
(1-800-469-4663).
Stack Kit
Are you planning to stack your Kenmore washer and dryer? To do
so, find the stack kit in the dryer drum. Follow instructions
included with the kit. See “Location Requirements.”
Location Requirements
WARNING
34.15"
(86.74 cm)
Mobile home installations require special parts (listed following)
available for purchase from your local Sears store or Sears
Service Center. For further information, please call
1-800-4-MY-HOME
■ Mobile Home Installation Kit. Ask for Part Number 346764.
■ Metal exhaust system hardware.
®
(1-800-469-4663).
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
■ A location that allows for proper exhaust installation. A gas
dryer must be exhausted to the outdoors. See “Venting
Requirements.”
■ A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See “Electrical Requirements.”
■ A sturdy floor to support the total dryer weight of
127 lbs (57.6 kg). The combined weight of a companion
appliance should also be considered.
5
■ A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part No. 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
50"
(128.27 cm)
36"
(91.4 cm)
Custom undercounter installation - Dryer only
36" min
(91.4 cm)
1"*
(2.5 cm)
27"
(68.6 cm)
1"*
(2.5 cm)
*Required spacing
Closet installation - Dryer only
1"*
(2.5 cm)
14" max.*
(35.6 cm)
18" min.*
(45.72 cm)
5
28.65"
(72.77 cm)
"**
(12.7 cm)
A
A. Side view - closet or confined area
B. Closet door with vents
2
48 in.
(310 cm
2
24 in.
(155 cm
*
2
)
*
2
)
B
2"*
(5 cm)
3"*
(7.6 cm)
3"*
(7.6 cm)
*28.65"
(72.77 cm)
27"
(68.6 cm)
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0” (0 cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
■ Additional spacing should be considered for ease of
installation and servicing.
■ Additional clearances might be required for wall, door and
floor moldings.
■ Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
■ Companion appliance spacing should also be considered.
■ For cabinet installation, with a door, minimum ventilation
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
14" max.
(35.6 cm)
18" min.*
(45.72 cm)
1"
(2.5 cm)
27"
(68.6 cm)
A
1"
(2.5 cm)
(2.5 cm)
1"*
28.65"
(72.77 cm)
B
5"**
(12.7 cm)
A. Recessed area
B. Side view - closet or confined area
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for cabinet
installation
■ The dimensions shown are for the recommended spacing.
6
openings in the top of the cabinet are required.
7"* (17.8 cm)
7"* (17.8 cm)
9"*
(22.9 cm)
Mobile home - additional installation requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
■ Metal exhaust system hardware, which is available for
purchase from your local Sears store or Sears Service Center.
■ Mobile Home Installation Kit Part Number 346764. See “Tools
and Parts” section for information on ordering.
■ Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
28.65"
(72.77 cm)
1"*
(2.5 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
5"**
(12.7 cm)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for recessed or
closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
48 in.2 *
(310 cm2)
3"* (7.6 cm)
3"* (7.6 cm)
2
*
24 in.
(155 cm2)
*Required spacing
6"* (15.2 cm)
72"
(182.9 cm)
1"* (2.5 cm)
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
■ 120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
5¹⁄₂"**
(14 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
WARNING:Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE INSTRUCTIONS
7
Gas Supply Requirements
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
■ ³⁄₈" approved aluminum or copper tubing is acceptable for
lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.
■ If you are using Natural gas, do not use copper tubing.
■ ³⁄₈" flare x ³⁄₈" NPT adapter fitting between dryer pipe and ³⁄₈"
approved tubing.
■ Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
■ If your dryer has been converted to use LP gas, ³⁄₈" LP
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
■ Must include a shutoff valve:
®†
tape.
An individual manual shutoff valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1. The location should be easy to
reach for opening and closing.
A
C
E
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is designcertified by CSA International for LP (propane or butane) gases
with appropriate conversion.
■ Your dryer must have the correct burner for the type of gas in
your home. Burner information is located on the rating plate
in the door well of your dryer. If this information does not
agree with the type of gas available, contact your local Sears
store or Sears Service Center.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
Gas supply line
■ Must include ¹⁄₈" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
■ ¹⁄₂" IPS pipe is recommended.
B
A. ³⁄₈" flexible gas connector
³⁄₈
" pipe to flare adapter fitting
B.
¹⁄₈
" NPT minimum plugged tapping
C.
D. ½" NPT gas supply line
E. Gas shutoff valve
D
Gas supply connection requirements
■ Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
■ Use only pipe-joint compound. Do not use TEFLON
■ This dryer must be connected to the gas supply line with a
®†
tape.
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24.
Burner input requirements
Elevations above 10,000 ft (3,048 m):
■ When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
■ The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
½psi.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
8
Dryer gas pipe
■ The gas pipe that comes out through the rear of your dryer
has a ³⁄₈" male pipe thread.
■ Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
■ Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
1½"
(3.8 cm)
B
*6¼"
(15.9 cm)
A
A. ½" NPT gas supply line
B.
³⁄₈
" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (25.4 cm) from the floor. For a garage
installation, the gas pipe height must be an additional
18" (46 cm) from the floor.
Venting Requirements
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If this is a new vent system
Vent material
■ Use a heavy metal vent. Do not use plastic or metal foil vent.
■ 4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
4"
10.2 cm
4" (10.2 cm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your
dealer. For further information, please call
1-800-4-MY-HOME
www.sears.com or www.sears.ca.
Rigid metal vent
■ For best drying performance, rigid metal vents are
recommended.
■ Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
■ Flexible metal vents are acceptable only if accessible for
cleaning.
■ Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
■ Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
■ Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
®
(1-800-469-4663) or visit our website at
If using an existing vent system
■ Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
GoodBetter
9
Clamps
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
Clamp
Exhaust
Recommended hood styles are shown here.
B
A
4"
(10.2 cm)
4"
(10.2 cm)
A. Louvered hood style
B. Box hood style
The angled hood style (shown here) is acceptable.
4"
(10.2 cm)
2½"
(6.4 cm)
■ An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
■ Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
■ Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.
C
D
A
E
F
G
H
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.
WARNING
Fire Hazard
Cover unused exhaust holes with the following kit:
279818 (white)
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
10
A
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation (not an option
with pedestal installations)
B
C
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
AB
A. Over-the-top installation (also available with one
offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please call 1-800-4-MY-HOME
■ Over-the-Top Installation:
®
(1-800-469-4663).
Part Number 26-49900
■ Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch
Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch
Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
■ When using elbows or making turns, allow as much room as
possible.
■ Bend vent gradually to avoid kinking.
■ Use the fewest 90° turns possible.
Determine vent length and elbows needed for best
drying performance
■ Use the following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
■ NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
■ Shorten the life of the dryer.
■ Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.
Number of
90º turns
or elbows
0Rigid metal
1Rigid metal
2Rigid metal
3Rigid metal
4Rigid metal
Type of
vent
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Box or
louvered
hoods
64 ft (20 m)
36 ft (11 m)
54 ft (16.5 m)
31 ft (9.4 m)
44 ft (13.4 m)
27 ft (8.2 m)
35 ft (10.7 m)
25 ft (7.6 m)
27 ft (8.2 m)
23 ft (7 m)
Angled
hoods
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
29 ft (8.8 m)
17 ft (5.2 m)
21 ft (6.4 m)
15 ft (4.6 m)
Determine vent path
■ Select the route that will provide the straightest and most
direct path outdoors.
■ Plan the installation to use the fewest number of elbows and
turns.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See “Determine vent path” in “Plan Vent System.” Avoid 90º
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
11
Install Leveling Legs
B
D
WARNING
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer. Gently lay the dryer on the
cardboard. See Illustration.
3. Examine the leveling legs. Find the diamond marking.
Make Gas Connection
1. Remove the red cap from the gas pipe.
2. Using a wrench to tighten, connect the gas supply to the
dryer. Use pipe-joint compound on the threads of all nonflared male fittings. If flexible metal tubing is used, be sure
there are no kinks.
A
A. Flared male fitting
B. Non-flared male fitting
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to the action of LP gas. Do not use
TEFLON
A combination of pipe fittings must be used to connect the
dryer to the existing gas line. Shown is a recommended
connection. Your connection may be different, according to
the supply line type, size and location.
®†
tape.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor at the time of
installation.
Mobile home installations require a Mobile Home Installation Kit.
For more information, please call 1-800-4-MY-HOME
(1-800-469-4663).
®
A
B
³⁄₈
" flexible gas connector
A.
B.
³⁄₈
" dryer pipe
C.
³⁄₈
" to
³⁄₈
" pipe elbow
D.
³⁄₈
" pipe-to-flare adapter fitting
C
3. Open the shutoff valve in the supply line. The valve is open
when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
12
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Check that the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible
gas line.
4. Once the exhaust vent connection is made, remove the
corner posts and cardboard.
Level Dryer
Check the levelness of the dryer. Check levelness first side to
side, then front to back.
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again for
levelness.
2. Lay the door assembly on a flat, protected surface with the
inside (inner door assembly) facing up.
3. Remove the 6 Phillips head screws to release the outer door
assembly from the inner door assembly, as indicated below.
See illustration. It is important that you remove only the
6 indicated screws.
4. Lift the inner door assembly off the outer door assembly.
5. Rotate outer door 180°.
180˚
Reverse Door Swing
You can change your door swing from a right-side opening to a
left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space
to protect the surface.
Remove the door assembly
1. Remove the 4 screws that hold the door hinge on the front
panel of the dryer.
A
B
A. Dryer front panel
B. Door assembly
Reverse hinge
1. Use a small flat-blade screwdriver to remove 2 plug strips
from the inner door. Slide the head of the screwdriver under
the plugs, being certain not to scratch the inner door surface.
Lift up.
13
2. Remove the 4 screws that attach to the inner door hinge and
B
move the hinge to the other side. Reinstall the 4 screws.
A
A. Door hinge
3. Reinstall plug strips on opposite side of the inner door.
4. Check for fingerprints on the glass. Clean glass if necessary.
5. Place the inner door assembly inside the outer door
assembly. To fit correctly, the inner door assembly edge fits
completely inside the outer door assembly edge.
6. Reassemble the inner and outer door assemblies with the
6screws.
Reverse the strike
1. Use a small flat-blade screwdriver to remove plug strip from
the dryer door opening. Slide the head of the screwdriver
under the plugs, being certain not to scratch the dryer
surface. Lift up.
2. Remove the strike
3. Insert strike on the opposite side.
A
A. Plug strip (cannot be seen from this angle)
B. Door strike
Reinstall the door
1. Reattach door to dryer front panel with the 4 screws.
A
B
A. Dryer front panel
B. Door assembly
2. Check for fingerprints on the glass. Clean glass if necessary.
3. Close door and check that it latches securely.
14
Complete Installation
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Check the dryer’s final location. Be sure the vent is not
crushed or kinked.
4. Check that the dryer is level. See “Level Dryer.”
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
5. Plug into a grounded 3 prong outlet. Turn on power.
6. Remove any protective film or tape remaining on the dryer.
7. Dispose of/recycle all packaging materials.
8. Read “Dryer Use.”
9. Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
10. Select a Timed Dry heated cycle, and start the dryer. Do not
select the Air Only Temperature setting.
If the dryer will not start, check the following:
■ Controls are set in a running or “On” position.
■ Start button has been pushed firmly.
■ Dryer is plugged into a grounded 3 prong outlet.
■ Electrical supply is connected.
■ Household fuse is intact and tight, or circuit breaker has
not tripped.
■ Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the
dryer door and feel for heat. If you feel heat, cancel cycle and
close door. If you do not feel heat, turn off the dryer and
check that the gas supply line shutoff valve is open.
■ If the gas supply line shutoff valve is closed, open it, then
repeat the 5-minute test as outlined above.
■ If the gas supply line shutoff valve is open, contact a
qualified technician.
15
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.