Kenmore 11087577700 Owner’s Manual

®
Gas Dryer
Secadora a Gas
Models/Modelos 110.9756", 9757", 9758"_
= color number/n0mero de color
W10035060 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com
TABLEOF CONTENTS
WARRANTY ..................................................................................... 2
Tools and Parts ............................................................................ 5
Optional Pedestal ......................................................................... 5
Location Requirements ............................................................... 5
Electrical Requirements ................................................................ 7
Gas Supply Requirements ........................................................... 8
Venting Requirements .................................................................. 9
Plan Vent System ...................................................................... 11
Install Vent System .................................................................... 12
Install Leveling Legs .................................................................. 12
Make Gas Connection ............................................................... 13
Connect Vent ............................................................................. 13
Level Dryer ................................................................................. 13
Reverse Door Swing .................................................................. 13
Complete Installation ................................................................. 15
DRYER USE ................................................................................. 16
Starting Your Dryer .................................................................... 16
KENMORE APPLIANCE AND OPTIONAL PEDESTAL
WARRANTY
ONE YEAR LIMITED WARRANTY
When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME _to arrange for free repair.
If this appliance is used for other than private family purposes, this warranty applies for only 90 days from the date of purchase.
THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. SEARS WILL NOT PAY FOR:
1. Expendable items that can wear out from normal use, including but not limited to filters, belts, light bulbs, and bags.
2. A service technician to instruct the user in correct product installation, operation or maintenance.
3. A service technician to clean or maintain this product.
4. Damage to or failure of this product if it is not installed, operated or maintained according to all instructions supplied with the product.
5. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended purpose.
6. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
7. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
Stopping or Restarting Your Dryer ............................................ 17
Lock Controls ............................................................................ 17
Drying and Cycle Tips ............................................................... 17
Status Lights .............................................................................. 18
Cycles ........................................................................................ 18
Modifiers .................................................................................... 19
Options ...................................................................................... 20
Changing Cycles, Options and Modifiers ................................. 20
TUMBLE FREF MNon-Heated Dryer Rack ............................... 20
DRYER CARE .............................................................................. 21
Cleaning the Dryer Location ...................................................... 21
Cleaning the Lint Screen ........................................................... 21
Cleaning the Dryer Interior ......................................................... 22
Removing Accumulated Lint ..................................................... 22
Vacation and Moving Care ........................................................ 22
TROUBLESHOOTING .................................................................. 23
PROTECTION AGREEMENTS .................................................... 24
SERVICE NUMBERS ............................................... BACK COVER
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies only while this appliance is used in the United States and Canada.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co.
Dept. 817WA, Hoffman Estates, IL 60179
Sears Canada Inc.
Toronto, Ontario, Canada M5B 2B8
PRODUCTRECORD
In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.
Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your appliance.
Model number
Serial number Serial number
Purchase date Purchase date
PEDESTAL PRODUCT RECORD
In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.
Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your pedestal.
Model number
Save these instructions and your sales receipt for future reference.
Save these instructions and your sales receipt for future reference.
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
I WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer. [] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry- cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving. [] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
SAVE THESE iNSTRUCTiONS
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber-like materials.
[] Clean lint screen before or after each load. [] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See installation instructions for grounding requirements.
In the State of Massachusetts, the following installation instructions apply: [] Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T-handle type. [] A flexible gas connector, when used, must not exceed 3 feet.
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70.
INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here,
8" or 10" pipe wrench 8" or 10" adjustable
wrench (for gas connections)
Flat-blade screwdriver Adjustable wrench that
opens to 1" (2.54 cm) or hex-head socket wrench
(for adjusting dryer feet) v4" nut driver or socket
wrench (recommended)
Parts supplied
Remove parts package from dryer drum, Check that all parts were included,
4Leveling legs
NOTE: Do not use leveling legs if installing the dryer on a pedestal,
Level
Vent clamps
Knife
Pipe-joint compound resistant to LP gas
Caulking gun and
compound (for installing
new exhaust vent)
Pliers
Tape measure
Are you placing the dryer on a pedestal? You can purchase a pedestal separately for this dryer. This pedestal will add about 10" (25.4 cm) to the height of your unit for a total height of approximately 46" (116.8 cm),
For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor.
Optional pedestal
The pedestal is available in:
White - Part Number 46822
To order, call your local Sears store. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663).
Stack Kit
Are you planning to stack your Kenmore washer and dryer? To do so, find the stack kit in the dryer drum. Follow instructions included with the kit. See "Location Requirements,"
Parts needed
Check local codes and with gas supplier. Check existing gas supply, electrical supply and venting. Read "Electrical Requirements," "Gas Supply Requirements" and "Venting Requirements" before purchasing parts.
For close-clearance installations between 28,65" (72,77 cm) and 34.15" (86.74 cm), see "Plan Vent System" section for venting requirements.
I_- 34.15"--_1
(86.74 cm)
Mobile home installations require special parts (listed following) available for purchase from your local Sears store or Sears
Service Center. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663).
Mobile Home Installation Kit. Ask for Part Number 346764.
Metal exhaust system hardware.
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need
A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors, See "Venting Requirements."
A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements."
A sturdy floor to support the total dryer weight of 127 Ibs (57.6 kg). The combined weight of a companion appliance should also be considered.
Alevelfloorwithamaximumslopeof1"(2.5cm)underentire dryer.(Ifslopeisgreaterthan1"[2.5cm],installExtended DryerFeetKit,PartNo.279810.)Clothesmaynottumble properlyandautomaticsensorcyclesmaynotoperate correctlyifdryerisnotlevel.
Donotoperateyourdryerattemperaturesbelow45°F(7°C).At lowertemperatures,thedryermightnotshutoffattheendofan automaticcycle.Dryingtimescanbeextended.
Thedryermustnotbeinstalledorstoredinanareawhereitwill beexposedtowaterand/orweather.
Checkcoderequirements.Somecodeslimit,ordonotpermit, installationofthedryeringarages,closets,mobilehomes,or sleepingquarters.Contactyourlocalbuildinginspector.
NOTE:Nootherfuel-burningappliancecanbeinstalledinthe sameclosetasadryer.
Installation clearances
The location must be largeenough to allow the dryer door to open fully.
Dryer Dimensions
36"/
(61.4 crn)
Custom undercounter installation - Dryer only
.... 2"*
36"rnin {_"_
"'il I
1"* _ "_""-27"----_ _ 1"*
25crn 68.6crn 25crn
* Required spacing Closet installation - Dryer only
_i 8 in.z*
Oc2) -
4 irt.2 _
5crn2)
I1"'1<-20.66"_'1s"**l
{2.5cm) (72.77cm) (12.7cm)
A
A. Side view - closet or confined area B. Closet door with vents
-J3,
_3"*
(7.6 cm)
't
{7.6 crn)
7
* Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
I;I
OO
H
©
v
_l:_ 27" ---}_
(2.5crn)
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
(68.6 cm)
-<_1" h"*l* 28.65"91s"**l
(2.5cm) (2.5cm) (72.77cm) (12.7cm)
A
A. Recessed area B. Side view - closet or confined area
B
Mobile home - additional installation requirements
Installation spacing for cabinet installation This dryer is suitable for mobile home installations.
[] The dimensions shown are for the recommended spacing. Construction and Safety Standard, Title 24 CFR, Part 3280
[] For cabinet installation, with a door, minimum ventilation (formerly the Federal Standard for Mobile Home Construction
openings in the top of the cabinet are required, and Safety, Title 24, HUD Part 280).
._.<J-r..]"_(17.8cm) 7"*(17.8cm) Metal exhaust system hardware, which is available for
± !
The installation must conform to the Manufactured Home
Mobile home installations require:
purchase from your local Sears store or Sears Service Center. Mobile Home Installation Kit Part Number 346764. See "Tools
and Parts" section for ordering information. Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
11
* Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recommended installation spacing for recessed or closet installation, with stacked washer and dryer
The dimensions shown are for the recommended spacing.
48 in. 2 *
{310 cm 2)
±
5"** 28.65" 1"
(12.7 cm) (72.77 crn) (2.5 crn) (2.5 cm)(68.6 crn) (2.5 crn)
3"* (7.6 cm)
T
o
3"* (7.6 cm)
24 in.2*
(155crn2)
*Required spacing
_ _- 1"*(2.5 crn)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
GROUNDING iNSTRUCTiONS
[] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
72"
(182.9crn)
5"* _ ._- I"--}_ _,_-27"-_ _ -_--1"
{12.7 crn) (2.5 crn) 68.6 cm 2.5 crn
*For side or bottom venting, 0" (0 cm) spacing is allowed.
WARNING: improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to de so can result in death, explosion, or fire.
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion.
Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your local Sears
store or Sears Service Center.
LP gas conversion: Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.
Gas supply line
Must include r/s"NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).
V2"IPS pipe is recommended.
%" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.
If you are using Natural gas, do not use copper tubing.
%" flare x %" NPT adapter fitting between dryer pipe and %" approved tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.
If your dryer has been converted to use LP gas, %" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON _ttape.
Must include a shutoff valve: An individual manual shutoff valve must be installed in
accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6)feet (1.8 m) of the dryer and the location be easy to reach for opening and closing.
A C E
B D
A.%" flexible gas connector B. _" pipe to flareadapter fitting C. _" NPTminimum plugged tapping D. _2"NPTgas supply line
E.Gas shutoff valve
Gas supply connection requirements
Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON_ tape.
This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, CSA 6.10.
Burner input requirements
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than _/_psi.
_®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer has a %" male pipe thread.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.
B
(15.9 cm)
A. Y2"NPT gas supply line
B. %" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (25.4 cm) from the floor. For a garage installation, the gas pipe height must be an additional
18" (46 cm) from the floor.
Fire Hazard
Use a heavy metal vent. Do not use a plastic vent.
Do not use a metal foil vent. Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFF Mventing products are recommended.
4" (lO.2 cm) heavymetal exhaust vent
DURASAFF Mvent products can be purchased from your dealer. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4863} or visit our website at
www.sears.com.
Rigid metal vent
For best drying performance, rigid metal vents are recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for cleaning.
Flexible metal vent must be fully extended and supported when the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.
Do not install flexible metal vent in enclosed walls, ceilings or floors.
Elbows
45° elbows provide better airflow than 90° elbows.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.
Good Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
_4 4 (1_-4"cm)
(10.2 cm)
A. Louvered hood style B. Box hood style
The angled hood style (shown here) is acceptable.
(6.4 crn)
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
10
Alternate installations for close clearances
Choose your exhaust installation type Venting systems come in many varieties. Select the type best for
Recommended exhaust installations
your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions.
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
B
i/
I II
A .....
................. F
...................................G
A B
A. Over-No-top installation (also availablewith one
offset elbow)
B.Periscope installation
A. Dryer
B. Elbow C. Wall D. Exhaust hood
E, Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows H. Exhaust outlet
NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663}.
Over-the-Top Installation: Part Number 26-49900
Periscope Installation (For use with dryer vent to wall vent mismatch):
Optional exhaust installations
Part Number 26-49901 - Less than 5" (12.7 cm) mismatch Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch
Fire Hazard
Cover unused exhaust holes with the following kit: 279818 (white)
Contact your local dealer. Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the
dryer converted.
A B
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation C. Bottom exhaust installation (not an option
with pedestal installations)
Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
When using elbows or making turns, allow as much room as possible.
Bend vent gradually to avoid kinking.
Use the fewest 90 °turns possible.
11
Determine vent length and elbows needed for best
drying performance
Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying performance.
Vent system chart
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart.
Number of Type of Box or Angled 90° turns vent Iouvered hoods
or elbows hoods
0 Rigid metal 64 ft (20 m) 58 ft (17.7 m)
Flexible metal 36 ft (11 m) 28 ft (8.5 m)
1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m)
Flexible metal 31 ft (9.4 m) 23 ft (7 m)
2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m)
Flexible metal 27 ft (8.2 m) 19 ft (5.8 m)
Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.
2. Firmly grasp the body of the dryer. Gently lay the dryer on the cardboard. See Illustration.
3. Examine the leveling legs. Find the diamond marking.
3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m)
Flexible metal 25 ft (7.6 m) 17 ft (5.2 m)
4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m)
Flexible metal 23 ft (7 m) 15 ft (4.6 m)
1.
Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2.
Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3.
Run vent to dryer location. Use the straightest path possible. See "Determine vent path" in "Plan Vent System." Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior
of the vent to secure vent.
4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor at the time of installation.
Mobile home installations require a Mobile Home Installation Kit. For more information, please call 1-800-4-MY-HOME ®
(1-800-469-4663).
12
1=
Remove the red cap from the gas pipe.
2.
Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on the threads of all non- flared male fittings. If flexible metal tubing is used, be sure
there are no kinks.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
Check the levelness of the dryer. Check levelness first side to side, then front to back.
A. Flared male fitting B. Non-flared male fitting
NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action of LP gas. Do not use TEFLON _t tape.
A combination of pipe fittings must be used to connect the dryer to the existing gas line. Shown is a recommended connection. Your connection may be different, according to the supply line type, size and location.
!
A
A. _" flexible gas connector
B. @" dryerpipe C. _" to _" pipe elbow D. @"pipe-to-flare adapter fitting
3=
Open the shutoff valve in the supply line. The valve is open when the handle is parallel to the gas pipe.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for
levelness.
C_OO @W C_
You can change your door swing from a right-side opening to a left-side opening, if desired.
1. Place a towel or soft cloth on top of the dryer or work space to protect the surface.
Remove the door assembly
1. Remove the 4 screws that hold the door hinge on the front panel of the dryer.
A. Dryer front panel B. Door assembly
A.Closed valve B.Open valve
4.
Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Make sure that there are no kinks in the flexible gas line.
1-®TEFLON is a registered trademark of E.L Du Pont De Nemours and Company.
2.
Lay the door assembly on a flat, protected surface with the inside (inner door assembly) facing up.
3.
Remove the 6 Phillips head screws to release the outer door assembly from the inner door assembly, as indicated below.
See illustration. It is important that you remove only the 6 indicated screws.
o _
4=
Lift the inner door assembly off the outer door assembly.
13
5. Rotate outer door 180°.
180 °
Reverse hinge
1. Use a small flat-blade screwdriver to remove 2 plug strips from the inner door. Slide the head of the screwdriver under
the plugs, being certain not to scratch the inner door surface. Lift up.
6. Reassemble the inner and outer door assemblies with the 6 screws.
Reverse the strike
1. Use a small flat-blade screwdriver to remove plug strip from the dryer door opening. Slide the head of the screwdriver under the plugs, being certain not to scratch the dryer surface. Lift up.
2. Remove the strike
3. Insert strike on the opposite side.
®
2=
Remove the 4 screws that attach to the inner door hinge and move the hinge to the other side. Reinstall the 4 screws.
®
A. Door hinge
3. Reinstall plug strips on opposite side of the inner door.
4. Check for fingerprints on the glass. Clean glass if necessary.
5. Place the inner door assembly inside the outer door assembly. To fit correctly, the inner door assembly edge fits completely inside the outer door assembly edge.
A. Plug strip (cannotbe seen from thisangle)
B. Door strike
Reinstall the door
1. Reattach door to dryer front panel with the 4 screws.
14
A. Dryer front panel B. Door assembly
2. Check for fingerprints on the glass. Clean glass if necessary.
3. Close door and check that it latches securely.
1. Check that all parts are now installed. If there is an extra part, 7. go back through the steps to see which step was skipped. 8.
2. Check that you have all of your tools. 9.
3. Dispose of/recycle all packaging materials.
4. Check the dryer's final location. Be sure the vent is not 10. crushed or kinked.
5. Check that the dryer is level. See "Level Dryer."
11.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter.
Do not use an extension cord, Failure to follow these instructions can result in death,
fire, or electrical shock.
Remove any protective film or tape remaining on the dryer. Read "Dryer Use." Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust. Select a Timed Dry heated cycle, and start the dryer. Do not
select the Air Only modifier. If the dryer will not start, check the following:
Dryer is plugged into a grounded 3 prong outlet.
Electrical supply is connected.
Household fuse is intact and tight, or circuit breaker has not tripped.
Dryer door is closed.
When the dryer has been running for 5 minutes, open the dryer door and feel for heat. Ifyou feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check that the gas supply line shutoff valve is open.
If the gas supply line shutoff valve is closed, open it, then repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, contact a qualified technician.
6. Plug into a grounded 3 prong outlet. Turn on power.